Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Acta Academiae Medicinae Sinicae ; (6): 359-363, 2020.
Article in Chinese | WPRIM | ID: wpr-826356

ABSTRACT

To evaluate the effect of monochromatic energy image on inferior vena cava imaging quality on dual-layer detector spectral CT. Totally 39 patients who were clinically suspected of abdominal disease and referred to perform contrast-enhanced computed tomography(CT)were prospectively enrolled and underwent abdominal examination using a single-source,dual-detector spectral CT.The delayed phase scan was performed 3 minutes after injection of 60 ml of iopamidol(320 mg/ml)at a rate of 3 ml/s.The raw images were reconstructed to obtain conventional mixed energy images and spectral based images(SBI).The 40,50,60,and 70 keV single energy images were obtained.The CT value,noise,and signal-to-noise(SNR)of inferior vena cava and the contrast-to-noise(CNR)of inferior vena cava relative to psoas major on conventional mixed energy images and the 40,50,60,70 keV single energy images were measured.The SNRs and CNRs on monoenergetic 40-70 keV images were compared with polychromatic 120 kVp images.ANOVA was used to compare the CT value,noise,SNR,and CNR among these five groups.The optimal monoenergetic image set was chosen. The differences in CT value,noise,SNR,CNR of inferior vena cava were statistically significant among five groups(all <0.05).The SNR and CNR in 40 keV group and 50 keV group were significantly higher than those in other groups(all <0.05).The SNR of 40 keV group was significantly higher than that of 50 keV group(=0.002).The CNR of 40 keV group was not statistical different compared with that of 50 keV group(=0.630). 40 keV is the optimal monoenergetic energy level for the inferior vena cava on dual-layer detector spectral CT and may be valuable for the diagnosis of inferior vena cava disease.


Subject(s)
Humans , Abdomen , Radiographic Image Interpretation, Computer-Assisted , Signal-To-Noise Ratio , Tomography, X-Ray Computed , Vena Cava, Inferior
2.
Journal of Practical Radiology ; (12): 750-753, 2017.
Article in Chinese | WPRIM | ID: wpr-614023

ABSTRACT

Objective To explore the value of CT spectral imaging in the demonstration of pancreatic ductal adenocarcinoma (PDAC).Methods 113 patients were scanned by CT spectral,and gemstone spectral imaging (GSI) was performed in late arterial phase (AP) and portal venous phase (PP).All diagnosis were pathologically confirmed.The ROIs were placed on the lesion and on the pancreatic parenchyma.The ROI files including the CTmono values and the normalized CTmono values (normalized to pancreatic parenchyma) were saved.The works were performed three times repeatedly.CNR values ranged from 40 keV to 140 keV and the optimal keV in AP and PP were calculated.The differences of CTmono values, normalized CTmono values,and CNR were compared between the optimal keV and 70 keV(equivalent to conventional 120 kVp energy level).Paired t-test and Wilcoxon signed rank test were performed.P<0.05 was considered statistically significant.Results The optimal monochromatic energy of PDAC were 40 keV in both AP and PP.The optimal CNR values(mean±standard) were 2.31±1.02 and 2.38±1.02 in AP and PP,while the corresponding values of 70 keV were 2.08±0.98 and 2.12±0.96.The CNR of 40 keV was higher than that of 70 keV in both AP and PP.The CTmono values of PDAC were (58±13) HU and (71±19) HU at 70 keV and were (111±44) HU and (155±57) HU at 40 keV in AP and PP.The CTmono value in PP was higher than in AP.The median of normalized CTmono values of PDAC at 40 keV were 47.0% and 53.9% in AP and PP, and were lower than those of 70 keV,which were 57.7% and 61.8%.The differences of normalized CTmono values between 40 keV and 70 keV were significant.Conclusion CT spectral imaging manifests that PDAC is hypovascular both in AP and PP and is progressively enhanced form AP to PP.There is maximal conspicuity of tumor in AP, and the optimal monochromatic imaging can improve the conspicuity of PDAC lesion.

SELECTION OF CITATIONS
SEARCH DETAIL