Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Article in Japanese | WPRIM | ID: wpr-377168

ABSTRACT

Endovascular aneurysm repair (EVAR) of pararenal abdominal aortic aneurysm (pararenal AAA) includes fenestrated or branched endografts, and the chimney technique. However, fenestrated and branched endografts are not currently available. An 82-year-old man, who underwent EVAR two years previously, was admitted to our hospital because of pararenal AAA measuring 56 mm. He underwent endovascular treatment with the chimney technique for bilateral renal arteries. We used a self-expanding and balloon-expandable uncovered-stent in renal arteries. Postoperatively he had slight renal dysfunction and acute pancreatitis, but was discharged 14 days after surgery. EVAR with the chimney technique for bilateral renal arteries was thought to be useful in high risk patients with pararenal AAA.

2.
Article in Japanese | WPRIM | ID: wpr-362979

ABSTRACT

Endovascular repair for abdominal aortic aneurysm (EVAR) has become widespread in Japan because of its low invasiveness. However adequate proximal neck length is required for EVAR. Unfortunately the surgical mortality of para-renal aortic aneurysm cases has been higher than that of infrarenal aortic aneurysm cases, especially in high-risk patients. A manufacture-modified fenestrated Zenith stent graft system has already been developed, however this new device is not yet available in Japan. Furthermore this device could not be used in an emergency situation because it takes 2-3 weeks for preparation. Therefore we introduced a surgeon-modified fenestrated Zenith stent graft (fenestrated Zenith) system in December 2010 for patients with a proximal neck length of 5-10 mm. The fenestrated Zenith was not indicated if the supra-renal angle and proximal neck angle exceeded 35°. From May 2007 to February 2012, abdominal aortic aneurysms (AAA) with a short neck were repaired with fenestrated Zenith in 11 high-risk patients (group Fene), and AAAs with a proximal neck length of more than 15 mm were repaired with a standard Zenith in 43 patients (group IFU). There were two ruptured AAA in the Fene group. Proximal neck length was significantly shorter in the Fene group (5.5±1.4 mm in the Fene group, 26.4±9.5 mm in the IFU group, <i>p</i><0.0001) and proximal neck angle was significantly less in the Fene group (20±13° in the Fene group, 36±18° in the IFU group, <i>p</i>=0.008). The Zenith stentgraft system was deployed successfully in all patients. The frequency of type Ia endoleak detected by angiography after stent graft deployment and balloon attachment did not differ significantly (36% in the Fene group 26% in the IFU group, <i>p</i>=0.475) and the frequency of Palmaz stent requirement for type Ia endoleak which persisted after 10 min of additional balloon attachment also did not differ significantly (27% in Fene group, 9% in IFU group). All fenestrated renal arteries were shown to be patent by angiography. There was no hospital death despite 2 cases of ruptured AAA, nor were these major complications in either group. Serum creatinine levels at 1, 3, 6 and 30 days after EVAR did not differ significantly between the 2 groups. In 9 out of 11 patients, only type II endoleaks were detected and aneurysm shrinkage tended to be more in Fene group (9.9±5.7 mm in Fene group, 5.4±6.1 mm in IFU group, <i>p</i>=0.062) on enhanced CT 6 months after EVAR. Also all fenestrated renal arteries were patent in these 9 patients. The surgeon-modified fenestrated Zenith system seemed to be effective for AAA patients with short proximal necks, but long term follow up is mandatory.

SELECTION OF CITATIONS
SEARCH DETAIL