1.
Journal of Applied Clinical Pediatrics ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-640092

ABSTRACT

Objective To evaluate the clinical value of 6 h 99mTc-diethyl iminodiacetic acid (99mTc-EHIDA) planar hepatobiliary scintigraphy (HBS),6 h tomographic HBS and 24 h planar HBS in diagnosis on biliary atresia(BA).Methods Seventy cases(32 male,38 female) with continuous jaundice received planar and tomographic HBS in Beijing Friendship Hospital from Jan.2005 to Dec.2007.The mean age was 48.7 d (29 d-4 months).According to final diagnosis,all cases were divided into BA group (45 cases) and non-BA group (25 cases).All cases fasted at least 4 hours before HBS.The equipment was 3 head IRIX from Philips company with low energy high resolution collimator.The tracer was 99mTc-EHIDA and the radiochemistry purity was more than 95 percent.The dosage was 7.4 MBq/kg.All diagnosis demonstrated by operation pathology and clinical follow-up.All cases received HBS at 5,10,15,20,30 min and 1,6 h after tracer injection.HBS would ended if radioactivity appeared in gallbladder or intestine.These cases would received tomographic HBS and 24 h HBS if radioactivity did not appear in gallbladder or intestine at 6 h post injection.All these images were analyzed by 2 or more nuclear medicine physicians.Results There were not radioactivity appearing in gallbladder and intestine on planar and tomographic HBS of 27 cases,which suggested the BA.There were radioactivity appearing in gallbladder and intestine on planar and tomographic HBS of 30 cases,which suggested the non-BA.Positive rate of 6 h tomographic HBS was significantly higher than that of 6 h planar HBS and there was significantly difference between the 2 methods.Positive rate of 6 h tomographic HBS was significantly higher than that of 24 h planar HBS and there was significant difference between the 2 methods.Conclusions 99mTc-EHIDA HBS is a noninvasive,safety,valuable examing method and has definitely clinical value in the diagnosis on BA.The clinical value of 6 h tomographic HBS is significantly higher than that of 6 h planar HBS and 24 h planar HBS.

2.
Korean Journal of Nuclear Medicine ; : 475-483, 1999.
Article in Korean | WPRIM | ID: wpr-40168

ABSTRACT

PURPOSE: Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. MATERIALS AND METHODS: Seventeen patients (M:F=12:5, mean age: 50.4+/-17.5 years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: 197+/-81 days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. RESULTS: All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern was 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake. The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization (1.96+/-0.87 vs 1.17+/-0.08, p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization (8.44+/-5.45 vs 2.20+/-0.87, p<0.05). CONCLUSION: In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy.


Subject(s)
Humans , Durapatite , Eye, Artificial , Gamma Cameras , Head , Orbit , Radionuclide Imaging , Technetium Tc 99m Medronate , Tomography, Emission-Computed, Single-Photon
SELECTION OF CITATIONS
SEARCH DETAIL