Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Organ Transplantation ; (6): 82-89, 2024.
Article in Chinese | WPRIM | ID: wpr-1005237

ABSTRACT

Objective To analyze three-dimensional imaging characteristics and advantages for severe portal vein stenosis after liver transplantation, and to evaluate clinical efficacy of portal vein stent implantation. Methods Clinical data of 10 patients who received portal vein stent implantation for severe portal vein stenosis after liver transplantation were retrospectively analyzed. Imaging characteristics of severe portal vein stenosis, and advantages of three-dimensional reconstruction imaging and interventional treatment efficacy for severe portal vein stenosis were analyzed. Results Among 10 patients, 3 cases were diagnosed with centripetal stenosis, tortuosity angulation-induced stenosis in 2 cases, compression-induced stenosis in 2 cases, long-segment stenosis and/or vascular occlusion in 3 cases. Three-dimensional reconstruction images possessed advantages in accurate identification of stenosis, identification of stenosis types and measurement of stenosis length. All patients were successfully implanted with portal vein stents. After stent implantation, the diameter of the minimum diameter of portal vein was increased [(6.2±0.9) mm vs. (2.6±1.7) mm, P<0.05], the flow velocity at anastomotic site was decreased [(57±19) cm/s vs. (128±27) cm/s, P<0.05], and the flow velocity at the portal vein adjacent to the liver was increased [(41±6) cm/s vs. (18±6) cm/s, P<0.05]. One patient suffered from intrahepatic hematoma caused by interventional puncture, which was mitigated after conservative observation and treatment. The remaining patients did not experience relevant complications. Conclusions Three-dimensional visualization technique may visually display the location, characteristics and severity of stenosis, which is beneficial for clinicians to make treatment decisions and assist interventional procedures. Timely implantation of portal vein stent may effectively reverse pathological process and improve portal vein blood flow.

2.
Chinese Journal of Clinical Oncology ; (24): 288-292, 2019.
Article in Chinese | WPRIM | ID: wpr-754412

ABSTRACT

Objective: To evaluate the efficacy and safety of portal vein stenting combined with 125I particle strand implantation followed by drug-eluting beads transarterial chemoembolization (DEB-TACE) and molecular-targeted therapy for the treatment of stageⅢa liv-er cancer lacking a blood supply. Methods: A retrospective analysis of 11 patients who had stageⅢa liver cancer lacking a blood sup-ply combined with portal vein tumor thrombosis (PVTT) was conducted from October 2016 to October 2018. All the patients under-went portal vein stenting combined with 125I particle strand implantation, DEB-TACE, and comprehensive treatment containing molecu-lar-targeted drugs. During the follow-up period, all patients were evaluated for stent patency after the implantation and tumor re-sponse after DEB-TACE treatment. The liver function and blood routine changes before and 1 month after the surgery were completed, and the complications were summarized. Results: All 11 patients were judged as stageⅢa liver cancer based on the Chinese staging criteria (2017), Child-Pugh classification grade A and B. The imaging findings indicated that these tumors were hypovascular. The maxi-mum diameter of these lesions was (8.4±4.1) (2.8-14.1) cm, and all patients had PVTT. Among them, there were 4 cases of Cheng's typeⅡand 7 cases of typeⅢ: 6 cases of main PVTT≥50% and 1 case of PVTT<50%. All patients underwent portal vein stenting com-bined with 125I particle strand implantation, DEB-TACE, and comprehensive treatment containing molecular-targeted drugs. Three and 6 months after stent implantation, the patency rate was 100%; 3 months after DEB-TACE treatment, complete response was achieved in 4 (36.4%) patients, partial response was achieved in 5 (45.5%) patients, and stable disease was achieved in 2 (18.2%) patients. No patients exhibited progressive disease. Therefore, the objective response rate was 81.8% and disease control rate was 100%. As for the liver and kidney function and blood routine tests, there were no significant differences between baseline and 1 month after the sur- gery. In addition, no patient had any serious complication during the perioperative period. Conclusions: For patients with stageⅢa liv-er cancer lacking a blood supply and PVTT, a comprehensive treatment strategy including portal vein stenting combined with 125I parti-cle strand implantation, DEB-TACE, and molecular-targeted therapy can restore portal vein blood flow and maintain mid-and long-term stent patency, while effectively killing tumors and controlling tumor growth, which is a safe and effective treatment strategy.

3.
Journal of Interventional Radiology ; (12): 161-165, 2017.
Article in Chinese | WPRIM | ID: wpr-513491

ABSTRACT

Objective To investigate the feasibility and safety of portal 125I seed stent implantation combined with doxorubicin-eluting beads transcatheter arterial chemoembolization (DEB-TACE) for the treatment of hepatocellular carcinoma (HCC) associated with main portal vein tumor thrombus (MPVTF).Methods Prospective single-arm study was designed.Seven HCC patients with MPVTT were sequentially enrolled in this study to receive treatment.Portal pressure before and after portal vein stent implantation were determined,the liver function were tested before and 1-3 days,4 days,5-7 days after portal vein stent implantation,the results and the postoperative complications were analyzed.Results All 7 patients were in BCLC-C stage,with Child-Pugh classification being A-B level.All patients were diagnosed as massive type HCC complicated by portal vein tumor thrombus.The lesions were located in hepatic left lobe (n=l) and hepatic right lobe (n=6),tumor thrombus in left branch of portal vein was seen in one patient and tumor thrombus in right branch of portal vein was found in 6 patients,MPVTT was observed in all 7 patients.Portal 125I seed stent implantation plus DEB-TACE was successfully accomplished in all 7 patients.The portal pressure before and after stent implantation was 15.3 cmH2O and 10.2 cmH2O respectively,the postoperative pressure showed an obvious reduction.After stent implantation,a transient elevation of the serum total bilirubin (TB),alanine aminotransferase (ALT) and aspartate aminotransferase (AST) could be observed,which gradually decreased in 3-4 days;the recovery of TB level was slower than that of ALT and AST levels.Two patients had concomitant myocardial damage,which was gradually recovered in 2-3 days.Conclusion For the treatment of HCC associated with MPVTT,portal 125I seed stent implantation plus DEB-TACE is safe and feasible,although its long-term curative effect needs to be further clarified.

4.
Journal of Practical Radiology ; (12): 270-273, 2016.
Article in Chinese | WPRIM | ID: wpr-485834

ABSTRACT

Objective To explore the efficacy and safety of percutaneous transhepatic portal vein or transjugular intrahepatic portosystemie shunt (TIPS)to implant the portal vein metallic stent in treatment of cavernous transformation of portal vein (CTPV).Methods Clinical and imaging data of 8 patients with CTPV were retrospectively analyzed who were treated in our hospital.All patients were treated with metallic stent implantation in portal vein including 3 patients by TIPS and 5 by percutaneous transhepatic portal vein.Results All patients were successful in the stent implantation without any occurrence of serious complications such as intra-abdominal hemorrhage and so on.Intraoperative angiography showed blood circulated freely in these stents.1 day-2 weeks later,the patients symptoms of abdominal pain and gastrointestinal bleeding were obviously relieved or disappeared.Follow up 1 month-3 years,1 patient with stent occlusion after one year of operation,the blood flow recovery after stent reimplantation,and the remaining patients,color doppler ultrasound reflected patency of blood flows in their stents.No one suffered from gastrointestinal bleeding or abdominal pain again.Conclusion Implantation of portal vein metallic stent via percutaneous transhepatic portal vein or via TIPS in treatment of cavernous transformation of portal vein is safe and effective.

SELECTION OF CITATIONS
SEARCH DETAIL