1.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-589836

ABSTRACT

The operating principle of magnetron lamp-wire power of accelerator is introduced,and the operating states are analyzed including tripolar circuit,lamp-wire current protection circuit,preheating time delay circuit and power circuit.Common failures and corresponding disposals are also introduced.

2.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-590640

ABSTRACT

Objective To develop infant thermal container with forced protection circuit so as to ensure its security. Methods Temperature database was set in thermal container and Cygnal F005 was used as intelligent controller. The state of the sensor was judged by comparison precisely. Double temperature controller was adopted to ensure normal working temperature. When the container went wrong, it could automatically switch to protection circuit to keep the temperature for infant. Results With precise temperature control and steady working station, the new type thermal container for infant could provide a safe and comfortable condition with clean air and fitting temperature and humidity. Conclusion The container is steady, accurate, safe and convenient.

3.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-586283

ABSTRACT

Although the type of XHD150B-IO 800mA X-ray machine possesses a damage protection electric circuit for the main thyristors, with the first switch of photographic hand valve pressed, abnormal instant exposure still appears when double (in different phase) or more than three main thyristors are broken through, short-circuited or mis-energized, and consequently the high voltage element or X-ray machine will break down. Therefore the original electric circuit must be improved. Material: A few of leads. Method: We exchange the conjunction sequence of three NO (normal open) contacting points of radiograph high voltage preparing work relay--MAG SW- R with three reverse parallel connection of main thyristors. Conclusion: The normal procedure of radiographic exposure won't be disturbed after the improvement. When whichever one or more than two main thyristors is broken through, short-circuited or mis-energized, the spoilage can be detected instantly and the protection circuit works correspondingly, which guarantees the safety of X-ray machine.