1.
Indian J Ophthalmol ; 2010 Jan; 58(1): 59-60
Article in English | IMSEAR | ID: sea-136014

ABSTRACT

Gonioscopy is an important component of evaluation of any glaucoma patient. Goldmann two-mirror and Sussman or Zeiss four-mirror are the commonly used gonioscopes. Presence of synechia in the angle is diagnostic of angle closure disease in an occludable angle. A patient with pseudo-goniosynechia that disappeared on indentation gonioscopy with Sussman lens but persisted with manipulation gonioscopy with a Goldmann lens is reported.


Subject(s)
Artifacts , Cornea/pathology , Diagnostic Errors , Female , Glaucoma, Angle-Closure/diagnosis , Gonioscopy/instrumentation , Humans , Middle Aged , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL