1.
China Medical Equipment ; (12): 7-11, 2018.
Article in Chinese | WPRIM | ID: wpr-706532

ABSTRACT

Objective: To design an ambulatory blood pressure measuring system based on control of single chip microcomputer AT89C51 so as to accurately measure the blood pressure of human body. Methods: In the design, single chip computer AT89C51 was used as main controller, and pressure transducer MPX5050GP was used to collect signal of blood pressure of human body, and then through calculated and processed of single chip microcomputer to measure the blood pressure value. The peripheral design adopted on-off circuit and liquid crystal display (LCD) to monitor the start control and blood pressure value of system. Results: This system could convert the blood pressure signal of human body into electrical signal through pressure transducer. And after these weak electrical signals were amplified and filtrated, they were further convert into digital signal so as to be inputed in single chip microcomputer. And then, these measurement value were finally displayed on LCD through calculating and processing of main program for these signals. The results of this system has well stability, and its largest indication error was 3 mmHg, which was in the permissible error range, and the detection was qualified. Conclusion: The system can accurately measure the blood pressure of human body, and it has the advantages of small size, convenient using, clear display and so on.

2.
China Medical Equipment ; (12): 1-4, 2018.
Article in Chinese | WPRIM | ID: wpr-706511

ABSTRACT

Objective: To design a disinfection system for pipeline of dialysis water that can be automatically controlled so as to improve the disinfection effect, and ensure the health and safety of the operators and patients with hemodialysis. Methods: In the new disinfection system, the manual control was changed to single chip, and the disinfection method was ozone disinfection. In the actual ozone disinfection instrument for the pipeline of dialysis water, through the relationship among solubility, half-life period and temperature of underwater ozone to obtain a simulate relational expression between disinfection time and temperature, and then through single chip to achieve automatic control of disinfection process. Results: Through experimental verification, the system was able to coordinately complete automatic disinfection, emptying and swashing, and the concentration of ozone could meet the requirements of setting. Conclusion: The design can effectively disinfect the pipeline of dialysis water and avoid harm for human body in operation. And the added functions, automatic emptying and swashing, can ensure the pipeline of dialysis water is applied in dialysis cure as soon as possible after the disinfection was completed, and it guarantee the safety of hemodialysis.

3.
Chinese Journal of Analytical Chemistry ; (12): 611-619, 2017.
Article in Chinese | WPRIM | ID: wpr-512627

ABSTRACT

A 8-channel neural signal′s simultaneous transducer detection micro system was developed to research the neural loop located at the brain hippocampus zone. The components of the system contained the neural probe manufactured with the Micro-electro-mechanical-systems (MEMS) technique based on silicon-on-insulator (SOI) substrate, biological low noise chopper-stabilization amplifier, low noise and intermediate speed SAR-ADC converter, reduced and low power ASK/FSK modulation radio transmitter. The micro system was applicable with the characters of small volume, interferences free, neural electrophysiology and neurotransmitter simultaneous detection, high sensitivity, high linearity, etc. The electrode resistance was optimized to 35.0 kΩ after depositing nanometer platinum black on the 4 electrophysiological sites on the Pt electrode. With the modification enzyme technique, nanomaterial enzyme membrane (Pt-mPD-GluOx) was directly fixed on the glutamate detection locus for selectively detecting special neural neurotransmitter matter. In addition, the electrochemistry measurement results indicated that the linear range of glutamate was 6-35 μmol/L with correlation coefficient of 0.97, the sensitivity was 0.0069 pA/(μmol/L). The current response error was less than 3.0 pA, which showed that the neural needle satisfied differential selection. Also, the logic/analog mixed signal 180-nm Application specific integrated circuit (ASIC ) technique (SmicRF180 nm 1Poly6M) was used to manufacture the transducer back-end disposing IC chip, and the test results provided some key parameters such as chopper-stabilization amplifier (equivalent in putting noise voltage ≤0.7 μV rms@1 kHz, gain of 71-82 dB, CMRR/PSRR>100 dB), SAR-ADC (ENOB is 12 bits, power consumption is 1.2 mW when maxmium conversion speed is 1 Msps, signal-noise-ratio is 60.9 dB, etc), and ASK/FSK modulation radio transmitter (the PA′s outputting power of 4-5 dBm, the radiation range of 10 meters). The micro neural transducer integrated system was convenient and wireless wearable for the research of brain hippocampus region.

4.
China Medical Equipment ; (12): 14-16, 2016.
Article in Chinese | WPRIM | ID: wpr-493891

ABSTRACT

Objective:Some medical liquid needs to be heated to the human body temperature, so the constant temperature case is a necessary equipment. But the common constant temperature case is often bulky, inconvenient application and the price is very high, so this paper is mainly to develop a convenient and cheap thermostat device for medical liquid heating.Methods:The system used single-chip microcomputer for temperature control. The temperature sensor collected and displayed the temperature of the box when the temperature was set up. Then the heating module started when the temperature was lower than the set point, and stopped heating when reaching to the set point.Results: The temperature control effect of constant temperature case tested by calibrated mercury thermometer, the temperature of constant temperature case was not significantly different from that of mercury thermometer.Conclusion: The portable constant temperature case for medical liquid have the characteristics of precise temperature control, high temperature resolution, and small temperature fluctuations. It can meet the clinical needs and be worth to popularizing in clinical applications.

5.
China Medical Equipment ; (12): 7-10,11, 2016.
Article in Chinese | WPRIM | ID: wpr-603555

ABSTRACT

Objective:To analyze the relationship between the concentration of glucose and the impedance of human blood, and study the relationship between human blood glucose detection and human blood impedance.Methods:The system adopts the AD5933 digital frequency synthesizer (DDS) in the excitation signal is produced, imposed on the impedance under test, the ADC acquisition signal and sent to the corresponding chip DFT digital processing module, measurement results through the I2C sent to the microcontroller, again by the single-chip microcomputer and PC computer communication, the computer shows that the impedance values. Results:The instrument can realize the resistor, capacitor, inductance, glucose solution impedance measuring rapidly and accurately, through experimental verify that resistive impedance deviation from the mean is 0.04, phase deviation from the mean is 0.15°.Conclusion:The glucose concentration of aqueous solution was linearly correlated with the impedance, the correlation coefficient greater than 0.99.

6.
China Medical Equipment ; (12): 13-15, 2014.
Article in Chinese | WPRIM | ID: wpr-459483

ABSTRACT

Objective:The platelet thermostatic storage box is widely used in hospital, laboratory, and blood station. It is very necessary to develop a calibration device to ensure the accuracy of the technical parameters.Methods: Using Infrared emitter, digital temperature sensor, ARM microcontroller etc to form a calibration device, the parameters of temperature, amplitude and frequency are processed. Data is transferred by Bluetooth communication, final; the test report is printed out for clinical.Results: The calibration device is developed, it can detect the important performance parameters of preservation box, it can ensure the safety of patient's blood transfusion. Conclusion: This calibration device is simple operation, strong practicability, stable performance; it can detect the technical parameters of platelet thermostatic storage box through experiment to ensure the safety and quality.

7.
China Medical Equipment ; (12): 29-30,31, 2013.
Article in Chinese | WPRIM | ID: wpr-582965

ABSTRACT

Objective: To design one kind of medical infusion pump. Methods: Based on single-chip microcomputer, 89C52, use the stepper motor to drive the semi extrusion micro flow pump. Results:During the infusion it can real-time monitor the block and bubble in the pipeline and alarm. It can accurately control the transfusion speed and infusion volume. With friendly man-machine interface it can display real-time infusion parameters and alarm signals. Conclusion: The infusion pump system has high precision and reliability, perfect function, and it is easy to use. Clinical practices show that it can effectively reduce the workload of the clinical nursing staff and improve work efficiency. It has high application value.

8.
China Medical Equipment ; (12): 35-36, 2013.
Article in Chinese | WPRIM | ID: wpr-440972

ABSTRACT

Objective: To cool down the implementation of field training injury cold and heat function of electric control part. Methods:To design of peripheral control circuit, the use of STM32 microcontroller software compiled program, temperature control function of the whole device. Results: Though the program running, it realized the function of temperature control device. Conclusion:STM32 MCU has powerful functions, low price, simple use, convenient development advantages, suitable for use in other medical equipment electrical control part.

9.
Chinese Journal of Medical Physics ; (6): 1773-1776, 2010.
Article in Chinese | WPRIM | ID: wpr-500248

ABSTRACT

Objective: This item presents a feasible scheme of home monitoring device which is a low power and miniaturization equipment for human signal detection, based on single-chip technology. Methods: Taking MSP430F149 as core, the realized functions of system contain real time data acquisition, data processing, data storage, LCD and alarming, keyboard as well as com-munication, replay and reproeessing by host computer. Results: The physiological and biochemical parameters are acquired by system and transmitted to host computer. Conclusions: This design provides a platform for multi-parameters portable detection just as dynamic ecg, ambulatory blood pressure, and so on. It has a good future for application.

10.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-595863

ABSTRACT

Objective To develop a facility to sterilize the heat-sensitive precise medical surgical instruments which can not resist high temperature and high pressure. Methods We used electromagnetic field of high frequency as excitation source for plasma,vacuumized the instrument,pumped in the peroxide,maintained the pressure in the instrument within a certain range,and then applied magnetic RF electric field,causing glow discharge and generating ambiplasma. The microorganism could be quickly destroyed under the synergistic effect of peroxide and low -temperature ambiplasma. Results The facility can sterilize the medical instruments within 45 minutes,enhance the surgical security and reduce the cost. Conclusion By controlling the primary parameters such as temperature,vacuity and time,the sterilization process can be finished in a low temperature safely,easily and quickly,so it is gradually accepted by the medical department.

11.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-595538

ABSTRACT

Objective To develop a more reliable blinking emergency location transmitter with longer time for aircrew in distress. Methods The new LED and new type of explosion-proof casing material (Polycarbonate) with new technologies are adopted. Results Environmental tests and performance tests were done on the new emergency location transmitter according to the environmental requirements of aeronautic products. Conclusion The new emergency location transmitter can meet the operation requirements for aircrew in distress.

12.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-595515

ABSTRACT

Objective To design a system that is many X-ray machines automatic operation,timely exposure to realize the sharing of power supply. Methods A circuit is designed based on the normal hospital conditions and go with proper control algorithm. The fifty-one series SCM were made use of in the hardware circuits,and validated by X-ray machine simulation tests which simplify the X-ray exposure to the process of relay controlling,which software is based on interrupt mechanism. Results The program could effectively control the exposal of many X-ray machines and the priority was indicated by the experiments. Conclusion Under the prerequisite of the system does not affect the exposure parameters of X-ray machine accuracy,the system can realize a number of X-ray machine's power-sharing,at the same time allow only a single X-ray exposure and use of the interrupted source. And it can make exposure many original X-ray machines can become closely related with high security,proper order and high performance,which has prominent benefits on areas with bad power and equipment conditions.

13.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-589635

ABSTRACT

Recognition of acupuncture points is a key step for acupuncture therapy and other corresponding physical treatment.Based on the electrical impedance property of acupuncture points,a bio-impedance detection circuit is designed to measure acupuncture points.The system consists of impedance detection circuit,A/D convertor,impedance computation and LED display.Experiment results suggests that the proposed system can be used for acupuncture points detection.

14.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-585183

ABSTRACT

The military portable ECG for triage is a kind of minitype monitoring equipment for life information for the purpose that the ambulanceman carry through first aids in frontline. Life information of the wounded will be acquired exactly and quickly applying with this equipment, then quickening the triage and reducing the casualties. The system is based on C8051F310 single chip microcomputer, applying with high accuracy, low offset drift instrumentation amplifier AD620 and ultra low power LCM LMS019 to display real-time and accurate ECG signal sampled. The equipment is easy to use and inexpensive, suitable for mass requirement of our field army.

15.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-584076

ABSTRACT

Exercise quantity is one of the important indexes used to evaluate physical consumption during training, so it is necessary to design a kind of instrument to accurately measure physical consuption. It must be practical, portable and with a low power consumption. This article introduces the mechanism of measuring exercise quantity. The methods of traditional and acceleration compared, the latter is selected. The design is described from the two aspects of general design and component choosing.

16.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-583997

ABSTRACT

In this paper, a novel portable low-frequency electronic pulse analgesia apparatus is introduced, which is based on a novel single-chip microprocessor, switching power supply without transformer and OTL power output amplifier. Through this apparatus, multi-group low-frequency electronic pulses can be produced to simulate the same effects as acupuncture. This apparatus has an observably curative effect for dysmenorrhea.

17.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-593107

ABSTRACT

Objective To solve the problem that the timely salvation can not be provided to the critical sick when nurses are not in nurse station and can not hear the sound of buzzer. Methods By utilizing SCM and wireless numerical transmission module, the former sick area treatment station calling system was developed. The special information was coded through SCM. The dada were sent and received with wireless numerical transmission module. In this way, a portable calling information receiving machine was designed. Results The reliable receiving distance of receiving machine is in the bound of 800 meters, and it provides 16 channels to use for different floors, having data transmission check function, little power loss, performance steady and credibility. Conclusion With sickroom calling message receiving machine, the nurse on duty can receive the calling message of the sick at any time and in any room, so rapid treatment can be provided on time, improving the satisfaction degree of sick. Besides, the sound of the calling system in the sick area treatment station can be shut down at noon and night, thus providing better circumstance for the sick to rest. The design is suitable for the calling system in any type and makes up the original shortages of the calling system in hospital.

18.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-585302

ABSTRACT

A kind of skin cell segregating unit based on 80C196 microcomputer is presented in this paper. The front-end controller is a single-chip microcomputer. The unit enables manipulation for 6 patients simultaneously which provides a great convenience for clinical manipulation of vitiligo. With use of serial port communication technology it's possible to monitor and control the front-end controller in a PC terminal. The involvement of computer image acquisition technology realizes synchronous acquisition of pathologic skin cell before/after the manipulation. Clinical test of the unit proves its conformity with national standards and fulfillment of designed technology goal.

19.
Journal of Chongqing Medical University ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-561542

ABSTRACT

Objective:In Order to study on biological effects of rotary magnetic field (RMF) conveniently and precisely,a digital-controlled instrument for generating RMF,which is based on a single-chip microcomputer,is developed.Methods:The precise frequency of RMF is controlled by using microcomputer to drive step motor,and intensity of magnetic field is measured by using 10-bit Analog-to-Digital(A/D) Converter module which is integrated in microcomputer.According,the technique of LCD screen to display relative information,such as,frequency,intensity of magnetic field,time of timer,is applied.Additionally, touching buttons,which is simple and convenience to use,is selected.Results:This instrument works very well with high precise frequency,and its operation is simple.As a example for this instrument,that biological effect of RMF on the the prostate about SD rat is significantly is found.Conclusion:This instrument may be used to research and study on biological effects of RMF widely.

20.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-686051

ABSTRACT

Objective In order to eliminate the influences caused by temperature and electrode-polarization, a new circuit of measuring electrical conductivity of water is designed by AT89S52 single-chip. Methods The system adopts the bi-directional pulsed voltage as its exciting source and the DS18B20 sensor as temperature compensation circuit component. Results Three functions which include auto-control, signal-collecting and display are realized by using C51 high-level language to write the modularization program. The precision of system is improved by an auto-temperature compensation way to avoid the blindness of temperature coefficient. Conclusion The system has such advantages as high accuracy and simple operation. Through further fulfilling, it can accord with user applying.

SELECTION OF CITATIONS
SEARCH DETAIL