Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.560
Filter
2.
Braz. j. biol ; 842024.
Article in English | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469374

ABSTRACT

Abstract The present study aimed to investigate the beneficial of prepared black rice anthocyanins nano-composite (An-AgNps) against hepatotoxicity induced by methotrexate (MTX) in rats. Anthocyanins nano-composite was prepared by silver as the metallic ion reduction and were characterized by IR and SEM. The rats in our experiment were divided into five groups. Serum lipid profile, serum transaminases (ALT and AST), ALP, LDH, TBA, GSH and SOD were examined. The results show that SEM of An-AgNps has average particle size from 70 to 130nm. In the group treated with MTX; TC, TG, LDL-c, ALT, AST, ALP, LDH and TBA levels were significantly (P0.05) increased than NC, while, HDL-c, SOD and GSH levels were significantly (P0.05) decreased. On the other hand, An-AgNps + MTX treated groups were reversed the levels of all biomarkers similar to NC. In conclusion, the results show that An-AgNps has a protective effect on MTX-induced hepatotoxicity and oxidative stress.


Resumo O presente estudo teve como objetivo investigar o benefício de nanocompósito de antocianinas de arroz preto preparado (An-AgNps) contra a hepatotoxicidade induzida por metotrexato (MTX) em ratos. O nanocompósito de antocianinas foi preparado a partir da prata por meio da redução do íon metálico e caracterizado por IR e SEM. Os ratos em nosso experimento foram divididos em cinco grupos, e foram examinados o perfil lipídico sérico, as transaminases séricas (ALT e AST), ALP, LDH, TBA, GSH e SOD. Os resultados mostram que SEM de An-AgNps tem tamanho médio de partícula de 70 a 130 nm. No grupo tratado com MTX, os níveis de TC, TG, LDL-c, ALT, AST, ALP, LDH e TBA aumentaram significativamente (P 0,05) do que NC, enquanto os níveis de HDL-c, SOD e GSH diminuíram significativamente (P 0,05). Por outro lado, nos grupos tratados com An-AgNps + MTX, foram revertidos os níveis de todos os biomarcadores semelhantes ao NC. Em conclusão, os resultados mostram que o An-AgNps tem um efeito protetor contra a hepatotoxicidade induzida pelo MTX e o estresse oxidativo.

3.
Article in English | LILACS, BBO | ID: biblio-1535004

ABSTRACT

ABSTRACT Objective: To identify the salivary metabolites profile of Mucopolysaccharidosis (MPS) types I, II, IV, and VI patients. Material and Methods: The participants were asked to refrain from eating and drinking for one hour before sampling, performed between 7:30 and 9:00 a.m. Samples were centrifuged at 10.000 × g for 60 min at 4°C, and the supernatants (500µl) were stored at −80°C until NMR analysis. The salivary proton nuclear magnetic resonance (1H-NMR) spectra were acquired in a 500 MHz spectrometer, and TOCSY experiments were used to confirm and assign metabolites. Data were analyzed descriptively. Results: Differences in salivary metabolites were found among MPS types and the control, such as lactate, propionate, alanine, and N-acetyl sugar. Understanding these metabolite changes may contribute to precision medicine and early detection of mucopolysaccharidosis and its monitoring. Conclusion: The composition of low molecular weight salivary metabolites of mucopolysaccharidosis subjects may present specific features compared to healthy controls.


Subject(s)
Humans , Male , Female , Saliva , Magnetic Resonance Spectroscopy/instrumentation , Mucopolysaccharidoses/pathology , Metabolomics , Proton Magnetic Resonance Spectroscopy/instrumentation , Cross-Sectional Studies/methods
4.
Braz. J. Pharm. Sci. (Online) ; 60: e23126, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1533981

ABSTRACT

Abstract A simple, rapid, precise, accurate and sustainable spectrofluorimetric method (SFM) was developed, validated and applied for the determination of 4-aminobenzoic acid and aromatic amino acids (phenylalanine, tryptophan and tyrosine). These compounds are used in biopharmaceutical formulations and therefore must be analyzed by quality control laboratories to meet the criteria established in pharmacopoeias. In general, potentiometric titration (PT) is described in the compendia as the official analytical technique. However, this method showed low sensitivity and selectivity, and moreover was performed with a non-aqueous solvent (acetic acid), which led to higher consumption of reagents and consequently to the formation of residues. Therefore, the SFM was developed in aqueous medium at pH 7.2 using phosphate buffer. It was successfully validated according to the ICH guidelines and showed good linearity range (r>0.999), specificity, accuracy and precision (within and between days) and robustness. The test results were compared between the SFM and PT using raw material samples, while according to the F- and t-tests at 95% confidence level, no statistical difference was found between the methods.

5.
Afr J Pharm Res Dev (AJOPRED) ; 16(1): 33-38, 2024. figures, tables
Article in English | AIM | ID: biblio-1553332

ABSTRACT

Quantitative analysis of heavy metals and nutrients in food helps indicate the safety and quality of food for final consumers. The present study was conducted to assess the presence of heavy metals (arsenic, copper, mercury, chromium, and lead) and the nutritional value of calcium in branded milk and yogurt to evaluate health risks for consumers. Ten (10) samples of branded milk and dairy products manufactured in Nigeria were purchased. The metal contents of the samples were determined using atomic absorption spectroscopy. The concentrations of calcium in the milk samples were between 9.33 ± 0.0023 and 18 ± 0.0071 ppm and were detected in all samples. Arsenic concentrations ranged from 0.45 ± 0.00042 to 2.48 ± 0.00064 ppm in eight branded samples but were undetected in two samples. Chromium levels were undetected in most samples, except for two with concentrations of 0.12±0.00049 ppm and 0.23±0.00021 ppm, respectively. Copper ranged from 0.032±0.00021 ppm to 0.129±0.00021 ppm in six samples. Mercury levels were detected in six samples at a concentration of 1.0±1.0 ppm. Lead concentrations ranged from 0.15±0.00064 to 0.29±0.00028 ppm in three samples. The study found heavy metals above the ideal concentration in branded milk and dairy products in Nigeria, highlighting the need for quality control measures during production to prevent contamination.

6.
Braz. dent. j ; 34(4): 54-61, July-Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1520342

ABSTRACT

Abstract This study compared the pH and calcium ion release of calcium silicate- (Bio-C Temp) and calcium hydroxide-based (Ultracal XS) medications. Intracanal remnants of both medications were also evaluated using SEM-EDS after the removal protocol. Thirty-five bovine teeth were prepared. Fifteen were filled with Bio-C Temp and 15 with Ultracal XS. Five remained without intracanal medication (control group). Five samples from each experimental time (i.e.. 24, 72, and 168 hours) were used to measure pH and calcium ions release using a digital pH meter and microplate reader, respectively. Afterward, the peaks of the chemical elements composing both medications were analyzed in SEM-EDS. One-way ANOVA and Tukey's post hoc test analyzed the pH and calcium ion release data. Student's t-test compared the medications in each experimental time. SEM-EDS described the percentage of chemical elements in the samples. Bio-C Temp and Ultracal XS showed a significant pH increase from 24 to 168 hours (p<0.05). Ultracal XS showed a higher pH value at 24 hours than Bio-C Temp (p<0.05) but were similar at 72 and 168h (p > 0.05). Calcium ion release did not depend on the experimental period (p > 0.05). Bio-C Temp showed lower calcium ions release than Ultracal XS at 24 hours (p<0.05). SEM-EDS analyses showed the remains of both medications, but the concentration of Si, Al, and W ions was present only in the calcium silicate-based medication. Bio-C Temp presented alkaline pH and a satisfactory calcium ion release over the time. The remaining of both medications were present after the protocols for paste removal.


Resumo Este estudo comparou o pH e a liberação de íons cálcio de medicações intracanais a à base de silicato de cálcio (Bio-C Temp) e à base de hidróxido de cálcio (Ultracal XS). Remanescentes de ambas as medicações também foram avaliados usando microscopia eletrônica de varredura e espectroscopia de dispersão de energia após o protocolo de remoção. Trinta e cinco dentes bovinos foram preparados. Quinze dentes foram preenchidos com Bio-C Temp e 15 com Ultracal XS. Cinco permaneceram sem medicação intracanal (grupo controle). Cinco amostras de cada tempo experimental (ou seja, 24, 72 e 168 horas) foram usadas para medir o pH e a liberação de íons de cálcio usando um medidor de pH digital e um leitor de microplacas, respectivamente. Em seguida, os picos dos elementos químicos que compõem os dois medicamentos foram analisados ​​em microscopia eletrônica de varredura e por espectroscopia de dispersão de energia. Os testes One-way ANOVA e post hoc de Tukey analisaram os dados de pH e liberação de íons cálcio. O teste t de Student comparou as medicações em cada tempo experimental. A microscopia eletrônica de varredura e a espectroscopia de dispersão de energia descreveu a porcentagem de elementos químicos nas amostras. O Bio-C Temp e o Ultracal XS mostraram um aumento significativo de pH de 24 a 168 horas (p<0,05). O Ultracal XS apresentou um valor de pH mais alto em 24 horas do que o Bio-C Temp (p<0,05), mas foi semelhante em 72 e 168h (p > 0,05). A liberação de íons cálcio não dependeu do período experimental (p> 0,05). O Bio-C Temp apresentou menor liberação de íons de cálcio do que Ultracal XS em 24 horas (p<0,05). As análises de microscopia eletrônica de varredura e espectroscopia de dispersão de energia mostraram remanescentes de ambas as medicações, mas a concentração de íons Si, Al e W estavam presentes apenas na medicação à base de silicato de cálcio. O Bio-C Temp apresentou pH alcalino e maior liberação de íons cálcio. Remanescentes de ambas as medicações estiveram presentes após os protocolos de remoção da pasta.

7.
Acta odontol. latinoam ; 36(2): 106-111, Aug. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1513553

ABSTRACT

ABSTRACT Fiber-reinforced prefabricated intraarticular posts have gained popularity due to several favorable characteristics for clinical use compared to metallic intraradicular posts. Aim: To evaluate the light transmission capacity of two types of fiber posts, using two different methods. Materials and Method: The posts were divided into two groups: experimental group - quartz-glass fiber posts (n=10) and control group - glass fiber posts (n=10). The light transmittance of the samples was compared by means of light intensity test by photographs and ultraviolet-visible spectrophotometer. This test was analyzed by thirds: coronal, middle, and apical. The spectophotometer tested the luminous transmittance along the length of the post. The statistical analysis was conducted with a significance level of 0.05. Results: Light transmission was 97% on the coronal third, 68% in the middle third, and 27.66% in the apical third in the posts of the experimental group. In the posts of the control group, the light transmission was 95.33% in the coronal third, 80.66% in the middle third, and 41.33% in the apical third. Light transmission was significantly higher in the middle third of the posts of the experimental group when compared to the control group (p<0.05). The luminous transmittance of the posts of the experimental group was 97.4% with wavelengths of 400 nm, 97% at 450 and 500 nm, and 96.9% at 550 nm. In the posts of the control group, the luminous transmittance was 72.3% with wavelengths of 400 nm, 68.6% at 450 nm; 64.6% at 500 nm and 61.5% at 550 nm. The posts of the experimental group demonstrated significantly higher light transmittance than the control group (p<0.001). Conclusion: the luminous transmittance of quartz-glass fiber posts is higher than glass fiber posts.


RESUMO Os pinos intra-articulares pré-fabricados reforçados com fibras têm ganhado popularidade devido a várias características favoráveis ao uso clínico em comparação com os pinos intra-radiculares metálicos). Objetivo: Avaliar a capacidade de transmissão de luz de dois tipos de pinos de fibra, usando dois métodos diferentes. Materiais e Método: Os pinos foram divididos em dois grupos: grupo experimental - pinos de fibra de vidro de quartzo e grupo controle - pinos de fibra de vidro. A transmitância de luz das amostras foi comparada por meio de teste de intensidade de luz por fotografias e espectrofotômetro ultravioleta-visível. Este teste foi analisado por terços: coronal, médio e apical. O espectrofotômetro testou a transmitância luminosa ao longo do comprimento do pino. A análise estatística foi realizada com nível de significância de 0,05. Resultados: A transmissão luminosa foi de 97% no terço coronal, 68% no terço médio e 27,66% no terço apical nos pinos do grupo experimental. Nos pinos do grupo controle, a transmissão de luz foi de 95,33% no terço coronal, 80,66% no terço médio e 41,33% no terço apical. A transmissão luminosa foi significativamente maior no terço médio dos pinos do grupo experimental quando comparado ao grupo controle (p<0,05). A transmitância luminosa dos pinos do grupo experimental foi de 97,4% com comprimento de onda de 400 nm, 97% em 450 e 500 nm e 96,9% em 550 nm. Nos postes do grupo controle, a transmitância luminosa foi de 72,3% com comprimento de onda de 400 nm, 68,6% em 450 nm; 64,6% a 500 nm e 61,5% a 550 nm. Os pinos do grupo experimental demonstraram transmitância de luz significativamente maior do que o grupo controle (p<0,001). Conclusão: a transmitância luminosa dos pinos de fibra de vidro de quartzo é maior do que pinos de fibra de vidro.

8.
CienciaUAT ; 17(2): 6-23, ene.-jun. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1447820

ABSTRACT

RESUMEN Los pozos cuánticos representan la base de una gran variedad de dispositivos electrónicos, entre ellos los ledes, láseres, fotodetectores y moduladores. Las propiedades optoelectrónicas de estos sistemas dependen de su composición química y del espesor de las capas crecidas. Por dicha razón, es necesario tener un control preciso durante su crecimiento. El presente trabajo tuvo como objetivo inducir el crecimiento epitaxial de pozos cuánticos intrínsecos (sin ningún dopaje) asimétricos acoplados y desacoplados de AlGaAs/ GaAs/AlGaAs, así como, establecer su caracterización mediante técnicas de espectroscopía óptica, como lo son la reflectancia diferencial, también conocida como espectroscopía de reflectancia anisotrópica (RAS) y la fotoluminiscencia (PL). Se realizó un estudio experimental de las interacciones entre niveles de energía en los pozos cuánticos asimétricos acoplados. Este tipo de estructuras son especialmente interesantes por permitir la formación y observación, no solo de excitones directos, dentro del mismo pozo, sino también, de excitones y triones indirectos, que se forman entre electrones de un pozo y huecos de otro pozo vecino (Transiciones intra-QW). Se hicieron crecer tres pozos intrínsecos, basados en arseniuro de galio (GaAs): un pozo individual (desacoplado) y un par de pozos asimétricos acoplados, a través de epitaxia por haces moleculares (MBE). Se observó el efecto del rompimiento de simetría (de D2d a C2v) en las propiedades espintrónicas de la estructura, a través de PL y RAS, a una temperatura de ~ 30 K. Se lograron establecer las técnicas y métodos necesarios para el crecimiento de pozos cuánticos intrínsecos, que constituyen la base para la creación de dispositivos y estructuras más complejas. El uso de técnicas espectroscópicas permitió demostrar la presencia de anisotropías ópticas, que repercuten en el comportamiento del espín de los excitones en pozos cuánticos.


ABSTRACT Quantum Wells are the basis for a great variety of electronic devices such as leds, lasers, photodetectors and modulators. Their optoelectronic properties depend on their chemical composition and the thickness of each layer. Therefore, a precise control during their growth is needed. This work has the objective of presenting the epitaxial growth of coupled and uncoupled asymmetric AlGaAs/GaAs/AlGaAs quantum wells and their characterization using optical techniques such as reflectance anisotropy spectroscopy (RAS) and photoluminescence (PL). An experimental study of the different interactions between the confined levels of energy in coupled quantum wells was carried on. This kind of structures is of special interest because they allow the formation and observation not only of direct excitons and trions inside a single quantum well, but of indirect excitons and trions, which are only formed by electrons of one quantum well and holes of the neighbor quantum well (IntraQW transitions). Three intrinsic quantum wells based on gallium arsenide (GaAs) were grown by molecular beam epitaxy (MBE), one single QW and a pair of coupled asymmetric QWs. The effect of breaking symmetry (from de D2d a C2v) on the spintronic properties of the structure was observed by RAS and PL measurements at ~ 30 K. The main techniques and methods for the growth of intrinsic quantum wells were established, which are the basis for the creation of devices with more complex structures. The use of spectroscopic techniques for the study of quantum wells allowed the demonstration of the presence of optical anisotropies that influence the behavior of exciton's spins at quantum wells.

9.
Article | IMSEAR | ID: sea-219300

ABSTRACT

The role of extracorporeal membrane oxygenation (ECMO) and its indications in stage I Norwood palliation are controversial. The decision to initiate ECMO and its timing remains difficult with no definitive cut?off points or evidence?based guidelines. It varies on a case?to?case basis. We report a case where the use of ECMO was beneficial after stage I Norwood palliation with severe ventricular dysfunction. The systemic?to?pulmonary artery shunt was kept open to balance the systemic and pulmonary circulations. Cerebral oximetry can be useful as an additional monitoring modality to guide management, monitor cerebral perfusion, and help detect cerebral steal.

10.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1551103

ABSTRACT

El monitoreo del contenido de humedad en el suelo es especialmente importante, ya que proporciona información relevante para tomar decisiones acertadas, en cuanto a riego, fertirriego y manejo del estrés hídrico. Este trabajo tiene como objetivo validar un modelo de estimación del contenido de agua en el suelo, mediante espectroscopía de reflectancia difusa en el rango del infrarrojo cercano. Los suelos evaluados provienen de los municipios de Puerto Gaitán (Meta), Espinal (Tolima) y Mosquera (Cundinamarca). En los dos primeros se establecieron redes rígidas, para seleccionar los puntos de muestreo y empleando dos profundidades en cada caso (0-10 y 10-30; 0-10 y 10-25 cm, respectivamente). Para el tercero, se describieron 77 calicatas y se tomaron muestras a 0-10 y 10-35 cm de profundidad. Posteriormente, se evaluó el contenido de humedad considerando 0, 15 y 30 % de humedad. Los datos obtenidos se analizaron con estadística descriptiva. Se empleó la validación cruzada y externa para cada modelo y se obtuvo un modelo general, a partir de los datos de los tres sitios. Los modelos obtenidos para cada sitio de muestreo y el modelo general tienen buena capacidad predictiva. Según los resultados, se afirma que la espectroscopía de reflectancia difusa NIR es una excelente opción para determinar el contenido de agua en el suelo. De igual manera, a partir del análisis de componentes principales, se identificó una diferenciación entre contenidos de agua de los suelos estudiados.


Monitoring soil moisture content is especially important as it provides relevant information for making informed decisions regarding irrigation, fertigation, and water stress management. This study aims to validate a model for estimating soil water content using diffuse reflectance spectroscopy in the near-infrared range. The evaluated soils come from the municipalities of Puerto Gaitán (Meta), Espinal (Tolima), and Mosquera (Cundinamarca). In the first two municipalities, rigid networks were established to select sampling points, with two depths considered for each case (0-10 and 10-30 cm; 0-10 and 10-25 cm, respectively). For the third municipality, 77 soil pits were described, and samples were taken at depths of 0-10 and 10-35 cm. Subsequently, moisture content was evaluated at 0, 15, and 30 % moisture levels. The obtained data were analyzed using descriptive statistics. Cross-validation and external validation were applied to each model, and a general model was developed based on the data from all three sites. The obtained models for each sampling site and the general model demonstrated good predictive capacity. Based on the results, it is affirmed that near-infrared diffuse reflectance spectroscopy is an excellent option for determining soil water content. Similarly, principal component analysis identified differentiation between water contents of the studied soils.

11.
Odovtos (En linea) ; 25(1)abr. 2023.
Article in English | LILACS, SaludCR | ID: biblio-1422197

ABSTRACT

This study evaluated selected structural and physical properties, such as degree of conversion (DC), Vickers hardness (VHN), and compression strength (CS), of three new dual-cure bulk-fill resin-based composites (RBCs; ACTIVA, HyperFIL, and Fill-Up) and compared them to those of a conventional RBC (Filtek Z250) at three clinically relevant depths. Samples (n=180) were prepared in three depths (2,4, and 6mm). Fourier-transform infrared spectroscopy (FTIR) analysis and VHN and CS tests were performed. The DC value was calculated by considering the relative change in the aliphatic C=C peaks. The fractured surfaces of representative samples were characterized using scanning electron microscopy (SEM). Data were statistically evaluated using two-way analysis of variance and post hoc Bonferroni tests (p<0.05). According to the VHN results, Filtek Z250 showed the highest bottom/top hardness ratio (97.94±1.01) at 2mm thickness and ACTIVA showed the lowest bottom/top hardness ratio (43.48±5.64) at 6mm thickness (p<0.001). According to the FTIR results, the DC decreased with increasing thickness in all materials (p<0.05). Filtek Z250 showed the highest (301±12.4 MPa) and ACTIVA exhibited the lowest (232±17.2 MPa) CS values at 2mm thickness (p<0.05). The lowest CS values were obtained for ACTIVA, and the highest values were obtained for Filtek Z250 for samples with thicknesses of 4 and 6mm, respectively (p<0.05). The structural features of restorative composites, such as the resin chemistry and filler type and content, and the operational parameters (i.e., material thickness and curing conditions) strongly affect crosslinking reactions and thus the DC, VHN, and CS values.


Este estudio evaluó propiedades físicas y estructurales, como el grado de conversión (DC), la dureza Vickers (VHN) y la resistencia a la compresión (CS), de tres nuevos compósitos a base de resina de curado dual tipo bulk (RBC; ACTIVA , HyperFIL y Fill-Up) y los comparó con los de una resina compuesta convencional (Filtek Z250) en tres profundidades clínicamente relevantes. Se prepararon muestras (n=180) en tres profundidades (2,4 y 6mm). Se realizaron análisis de espectroscopia infrarroja por transformada de Fourier (FTIR) y pruebas VHN y CS. El valor de DC se calculó considerando el cambio relativo en los picos alifáticos C=C. Las superficies fracturadas de muestras representativas se caracterizaron mediante microscopía electrónica de barrido (MEB). Los datos se evaluaron estadísticamente mediante análisis de varianza de dos vías y pruebas post hoc de Bonferroni (p<0,05). De acuerdo con los resultados de VHN, Filtek Z250 mostró la relación de dureza inferior/superior más alta (97,94±1,01) con un espesor de 2mm y ACTIVA mostró la relación de dureza inferior/superior más baja (43,48±5,64) con un espesor de 6mm (p<0,001). De acuerdo con los resultados de FTIR, la DC disminuyó al aumentar el espesor en todos los materiales (p<0,05). Filtek Z250 mostró los valores de CS más altos (301±12,4 MPa) y ACTIVA los más bajos (232±17,2 MPa) a 2mm de espesor (p<0,05). Los valores más bajos de CS se obtuvieron para ACTIVA y los valores más altos para Filtek Z250 para muestras con espesores de 4 y 6mm, respectivamente (p<0,05). Las características estructurales de las resinas compuestas de restauración, como la química; además del tipo y contenido del relleno, y los parámetros operativos (es decir, el espesor del material y las condiciones de curado) afectan en gran medida las reacciones de interacción química y, por lo tanto, los valores de DC, VHN y CS.


Subject(s)
Microscopy, Electron, Scanning , Composite Resins/analysis , Compressive Strength
12.
Article | IMSEAR | ID: sea-219450

ABSTRACT

Aims: This study evaluated the physical, chemical and rheological properties of exopolysaccharides (EPSs) produced by Lactic Acid Bacteria (LAB) isolated from palm wine. Materials and Methods: EPSs from palm wine LAB strains were produced on 6% sucrose broth, purified and freeze-dried prior to analyses. Molecular weights (MW), rheological and structural composition (functional groups) of the EPSs were determined using standard methods and Fourier transform infrared spectroscopy (FTIR). Results: The average MW of the EPSs ranged from 2.02×106 to 6.53×106 Da while the flow index (n) values ranged from 0.03-3.13 at 0.2%, 0.06-1.51 at 0.4%, 0.38 - 1.85 at 0.6%, 0.14 - 2.26 at 0.8% and 0.55 - 6.42 at 1% concentrations at elevated temperatures for EPS solutions from the ten LAB species. The FTIR spectrum revealed prominent peaks of various groups of OH (3420 cm-1) and CH3 bending (2090 cm-1) in all the EPSs corresponding to both hydroxyl and amine groups, and aliphatic C-H bonds, respectively. EPS synthesized by Leuconostoc lactis, Lactococcus lactis subsp lactis and Lactiplantibacillus plantarum showed weak absorption peaks (1148 – 1145 cm-1) indicating the C-O-C and C-O bonds, while absorption peaks of Lactobacillus lactis, Lactobacillus acidophilus and Lactiplantibacillus plantarum (1267 – 1253 cm-1) indicated O- acetyl ester and other non-sugar components. Conclusions: The FTIR spectra, rheological properties and molecular weight of EPSs synthesized by the ten LAB strains indicated potentials that could be exploited in different industrial applications, and as stabilizers in food industries

13.
Braz. dent. j ; 34(2): 56-66, Mar.-Apr. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439571

ABSTRACT

Abstract Natrosol and Aristoflex® AVC polymers are widely applied in the cosmetic industry and have recently been applied as a thickener option in the composition of dental bleaching gels, with the purpose to reduce the adverse effects on enamel mineral components. The aim of this study was to evaluate the color variation (ΔE* ab, ΔE00, ∆WID), surface roughness (Ra), and mineral content quantification (Raman Spectroscopy) of dental enamel after bleaching treatment with experimental gel-based on 10% carbamide peroxide (CP), containing Carbopol, Natrosol, and Aristoflex® AVC. Sixty bovine teeth were randomly divided into 6 groups (n=10): Negative Control (NC) - no treatment; Positive Control (PC) - Whiteness Perfect 10% - FGM; CP with Carbopol (CPc); CP with Natrosol (CPn); CP with Aristoflex® AVC (CPa); NCP - no thickener. Data were analyzed, and generalized linear models (∆WID -T0 x T1) were used for repeated measurements in time for Ra and with a study factor for ΔE* ab and ΔE00. For the evaluation of the mineral content, data were submitted to one-way ANOVA and Tukey tests. For enamel topographic surface analysis the Scanning Electron Microscope (SEM) was performed. A significance level of 5% was considered. ΔE* ab and ΔE00 were significantly higher for CPc, CPn, CPa, and NCP groups. (∆WID) showed a significantly lower mean than the other groups for NC in T1. After bleaching (4-hour daily application for 14 days), Ra was higher in the CPc, CPn, and PC groups. For CPa, Ra was not altered. No significant difference was found in the quantification of mineral content. CPa preserved the surface smoothness more effectively. Aristoflex® AVC is a viable option for application as a thickener in dental bleaching gels, presenting satisfactory performance, and maintaining the whitening efficacy of the gel, with the advantage of preserving the surface roughness of tooth enamel without significant loss of mineral content.


Resumo Os polímeros Natrosol e Aristoflex® AVC são amplamente utilizados na indústria cosmética e foram recentemente aplicados como uma opção de espessante na composição de géis de clareamento dental, com o objetivo de reduzir os efeitos adversos sobre os componentes minerais do esmalte. O objetivo deste estudo foi avaliar a variação de cor (ΔE*ab, ΔE00, ∆WID), rugosidade da superfície (Ra), e quantificação do conteúdo mineral (Raman Spectroscopy) do esmalte dentário após clareamento dental com gel experimental baseado em 10% de peróxido de carbamida (CP), contendo Carbopol, Natrosol e Aristoflex® AVC. Sessenta dentes bovinos foram divididos aleatoriamente em 6 grupos (n=10): Controle Negativo (CN) - sem tratamento; Controle Positivo (CP) - Brancura Perfeita 10% - FGM; CP com Carbopol (CPc); CP com Natrosol (CPn); CP com Aristoflex® AVC (CPa); NCP - sem espessante. Os dados foram analisados e modelos lineares generalizados (∆WID -T0 x T1) foram usados para medições repetidas no tempo para Ra e com um fator de estudo para ΔE*ab e ΔE00. Para a avaliação do conteúdo mineral, os dados foram submetidos a testes unidirecionais de ANOVA e Tukey. Para a análise da superfície topográfica do esmalte, o Microscópio Eletrônico de Varredura (SEM) foi realizado. Um nível de significância de 5% foi considerado. ΔE*ab e ΔE00 foram significativamente maiores para os grupos CPc, CPn, CPa e NCP. (∆WID) mostrou uma média significativamente menor do que os outros grupos para NC em T1. Após o clareamento (aplicação diária de 4 horas por 14 dias), Ra foi maior nos grupos CPc, CPn e PC. Para CPa, Ra não foi alterado. Nenhuma diferença significativa foi encontrada na quantificação do conteúdo mineral. O CPa preservou a suavidade da superfície de forma mais eficaz. Aristoflex® AVC é uma opção viável para aplicação como espessante em géis de clareamento dental, apresentando desempenho satisfatório e mantendo a eficácia clareadora do gel, com a vantagem de preservar a rugosidade da superfície do esmalte dentário sem perda significativa de conteúdo mineral.

14.
Acta ortop. bras ; 31(3): e262497, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447082

ABSTRACT

ABSTRACT Quantitative assessments of rotator cuff muscle changes after successful tendon repair are scarce. On the other hand, semiquantitative and subjective assessments are more abundant, but their findings are controversial. One hypothesis about this divergence is that there is an immediate decrease in the proportion of fatty infiltration after surgical repair. Objective: Reassess fatty infiltration and muscle trophism of the rotator cuff after ten years of repair. Methods: Prospective comparison study. A total of 10 patients diagnosed with rotator cuff injury underwent repair of the lesion, and MRI of the affected shoulder was performed in the preoperative, immediate postoperative, and late postoperative periods (ten years). A comparative study was performed at every moment. Results: At 5% significance level, the mean of the immediate postoperative period was higher for the variable trophism and true muscle percentage. Fatty infiltration showed no difference in the three periods observed. Conclusion: Fatty infiltration does not change in the three periods evaluated and muscle trophism is greater in the immediate postoperative period. After ten years of rotator cuff repair, muscle trophism and fatty infiltration remain with statistically significantly equal results when compared to the preoperative period. Level of Evidence II, Prospective Comparison Study.


RESUMO Avaliações quantitativas das mudanças musculares do manguito rotador após reparos bem-sucedidos são escassas. Em contrapartida, avaliações semiquantitativas e subjetivas são mais abundantes, porém com achados controversos. Uma hipótese sobre essa discrepância é que a diminuição imediata na proporção de gordura que ocorre logo após o reparo. Objetivo: Reavaliar a infiltração gordurosa e o trofismo muscular do manguito rotador passados dez anos do reparo. Métodos: Estudo prospectivo comparativo realizado com dez pacientes diagnosticados com lesão do manguito rotador que foram submetidos a reparo da lesão e exames de ressonância magnética do ombro acometido no pré-operatório, no pós-operatório imediato e no pós-operatório tardio (dez anos), a fim de comparar as mudanças musculares em cada momento. Resultados: Ao nível de significância de 5%, a média do pós-operatório imediato foi superior para as variáveis trofismo e porcentagem muscular verdadeira. A infiltração gordurosa não apresentou diferença nos três períodos observados. Conclusão: A infiltração gordurosa não se altera nos três períodos avaliados, e o trofismo muscular é maior no pós-operatório imediato. Após dez anos do reparo do manguito rotador, o trofismo muscular e a infiltração gordurosa se mantêm com resultados estatísticos significativamente iguais quando comparados com o pré-operatório. Nível de Evidência II, Estudo Prospectivo Comparativo.

17.
Journal of Forensic Medicine ; (6): 40-44, 2023.
Article in English | WPRIM | ID: wpr-984178

ABSTRACT

OBJECTIVES@#To establish a rapid and nondestructive identification method for human body fluid stains and non-biological stains using three-dimensional fluorescence spectroscopy.@*METHODS@#The collected three-dimensional fluorescence spectrum data of human saliva, 3% blood, coffee and Fanta® stains were processed with dimensionality reduction. After wavelet transform, spectral denoising and feature extraction, the classification formula was established. The Fisher discriminant was used for spectrum matching and recognition to establish the analysis method to distinguish stain types.@*RESULTS@#According to the results of data training and comparison, all the recognition accuracies of Fanta®, coffee, saliva and blood were more than 91.39%. Among them, saliva reached 100% recognition accuracy.@*CONCLUSIONS@#Three-dimensional fluorescence spectroscopy is a potential method for rapid and nondestructive identification of biological and non-biological stains.


Subject(s)
Humans , Forensic Medicine/methods , Coloring Agents/analysis , Coffee , Spectrometry, Fluorescence , Body Fluids/chemistry
18.
Chinese Journal of Behavioral Medicine and Brain Science ; (12): 127-132, 2023.
Article in Chinese | WPRIM | ID: wpr-992066

ABSTRACT

Objective:To investigate the neurobiochemical metabolites of caudate nucleus and thalamus in patients with obsessive-compulsive disorder and their relationship with obsessive-compulsive symptoms.Methods:From April 2019 to January 2022 in Beijing Anding Hospital, totally 25 untreated patients with obsessive-compulsive disorder were recruited, and 20 healthy controls matched with gender, age and educational background were recruited for the study.The maps of neurobiochemical metabolites of patients and normal controls were collected by hydrogen proton magnetic resonance spectroscopy.With bilateral caudate nucleus and thalamus as brain regions of interest.The relative concentrations of N-acetylaspartic acid (NAA), glutamic acid (Glu) and γ-aminobutyric acid (GABA) were fitted by LCModel software.At the same time, the clinical symptoms of patients were evaluated with Yale-Brown obsessive-compulsive scale (Y-BOCS) and Hamilton anxiety scale (HAMA). SPSS 20.0 software was used for statistical analysis.Independent double sample t-test was used to compare the differences of different nerve biochemical metabolite concentrations between patients with obsessive-compulsive disorders and healthy controls.Pearson correlation analysis was used to explore the correlation between biochemical metabolite concentrations and clinical symptoms. Results:The Glu concentration in the left thalamus of patients with obsessive-compulsive disorder (3.97±0.41) was higher than that of the control group (3.66±0.55)( t=-2.11, P<0.05), while the NAA concentration was (4.87±0.47)lower than that of the control group (5.15±0.44)( t=2.05, P<0.05). The GABA concentrations in the right caudate nucleus (0.50±0.18) and thalamus (0.80±0.19) were lower than those in the control group ((0.63±0.23), (0.96±0.24))( t=2.08, 2.36, both P<0.05). Pearson correlation analysis showed that the Glu concentration in the left caudate nucleus of patients with obsessive-compulsive disorder was positively correlated with the total score of Y-BOCS( r=0.46, P<0.05). Spearman correlation analysis showed that Glu concentration in the right caudate nucleus was positively correlated with the total score of HAMA in patients with obsessive-compulsive disorder ( r=0.46, P<0.05). Conclusion:NAA, Glu and GABA metabolism in caudate nucleus and thalamus are abnormal in patients with obsessive-compulsive disorder, and Glu concentration is positively correlated with the severity of obsessive-compulsive and anxiety symptoms.

19.
Chinese Journal of Experimental Ophthalmology ; (12): 812-817, 2023.
Article in Chinese | WPRIM | ID: wpr-990917

ABSTRACT

The visual signal generated by the eye receiving external light stimulation reaches the visual center through the visual pathway and is processed and integrated by the visual center to form a subjective sensation called cerebral vision.Cerebral vision reflects the function of the whole visual nervous system from the retina to the visual cortex.Abnormal cerebral vision has been found in myopes using electrophysiology, magnetic resonance imaging (MRI) and functional near-infrared spectroscopy (fNIRS). The abnormal electrophysiological results are mainly found in patients with high myopia and pathological myopia.MRI shows abnormal changes in the structure and function of several vision-related brain regions in patients with high myopia.Recently, by applying near-infrared brain function imaging technology combined with self-developed equipment, our team conducted a series of studies on the brain function of myopic patients and found that adult patients with moderate myopia and patients with pathological myopia have the abnormal cerebral vision.The mechanism of neural regulation of eye accommodation in myopic children needs further investigation.In this article, we reviewed the current status and outlook of myopic brain vision research in terms of myopia classification, myopic brain vision research methods, and myopic visual electrophysiology, MRI, and fNIRS studies.

20.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 1405-1419, 2023.
Article in Chinese | WPRIM | ID: wpr-1004673

ABSTRACT

ObjectiveTo explore the current status and frontier hotspots of functional near-infrared spectroscopy (fNIRS) in the field of stroke. MethodsRelevant literature on stroke and fNIRS from the Web of Science Core Collection (WoSCC) database was searched from its inception to July, 2023. VOSviewer, CiteSpace and Scimago were utilized for analysis of publication output, countries (regions) and institutions, international collaboration, co-cited references, co-occurring keywords and burst keywords. ResultsA total of 379 articles were included. The research activity in this field showed an overall upward trend with slight fluctuations in the early stage. Among the top five institutions by publication output, four were from China. Co-occurrence analysis revealed that Beihang University and Boston Children's Hospital were central in collaboration networks. This study involved 1 787 authors, with 120 core authors, in which the top five most cited authors were Li Zengyong, Li Wenhao, Huo Congcong, Dou Zulin and Song Ying. The publications in this field were primarily concentrated in disciplines such as neurology, psychiatry, ophthalmology and clinical medicine. Overlay visualization of journal co-citation networks demonstrated associations between medical, clinical, and neurology disciplines with psychology, education, and sociology. Co-occurrence and clustering analysis of keywords indicated research emphasis on stroke rehabilitation, integration of multiple technical modalities, and exploration of innovative training strategies and brain activation connectivity. The research evolution of fNIRS in the stroke domain revealed initial use of photodiode devices for cerebral ischemia reperfusion monitoring. Subsequent studies refined cortical activation through improved laser sources, avalanche photodiodes, single-task experimental designs and transcranial direct current stimulation. Later, research extended to whole-brain detection, multimodal stimulation and the combination of virtual reality technology with audiovisual stimulation, resulting in significantly enhanced brain activation. The application of brain-computer interface technology further facilitated direct restoration of motor function. ConclusionResearches in the field of stroke using fNIRS technology overall demonstrat a continuous upward trend. The researches focuse on post-stroke rehabilitation, integrating multimodal fusion, brain-computer interfaces, virtual reality, and sensory stimulation for real-time monitoring and personalized neurorehabilitation training strategies. It emphasizes interdisciplinary collaboration, expanding innovative research and the application of new technologies.

SELECTION OF CITATIONS
SEARCH DETAIL