Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Article | IMSEAR | ID: sea-186744

ABSTRACT

Introduction: Refractive error is the most common visual impairment seen worldwide. This is one of the main cause for which patients come to ophthalmologist. This can occur at any age of the patient. Automated refractometer has become popularised method for doing refraction because of the busy practise of ophthalmologist and due to heavy patients load in screening camps. It is an easy method to learn, to operate and also time saving procedure. Patients are also very comfortable with it because of this easy procedure done in short time. But Streak retinoscopy which is considered as a Gold standard technique for refraction, has some difficulties like time consuming, dilatation of pupil and discomfort to the patient. Aim: Comparing the effect of the conventional method of refraction with computerized automated refraction in various refractive error patients. Materials and methods: It was an observational, cross-sectional study done in a 50 refractive error patients who attend Department of Ophthalmology OPD. Results: According to the statistical analysis done to compare the refraction values of the auto refractometer and streak retinoscopy with the patient's acceptance value, results came as streak Deepikadevi SN, Sundararajan D, Namitha Bhuvaneshwari K, Murali Krishnan. Comparing the effect of conventional method of retinoscopic refraction with computerized automated refraction in various refractive error patients. IAIM, 2017; 4(10): 105-110. Page 106 retinoscopy values had no significant difference with the patient's acceptance value. This study also shows males were more affected by refractive errors than females and the mean age of affection in myopia was 19- 20 years and hypermetropia is 33-36 years. Conclusion: Since reteak retinoscopy values are accepted well by the patients, it is the better method for refrection than auto refractometer

2.
Ophthalmology in China ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-566649

ABSTRACT

Objective To investigate the effect of cyclopentolate cycloplegic on the refraction measurement in adult guinea pigs. Design Experimental study.Participants 24 eyes of 12(10 weeks) adult guinea pigs.Methods 12 animals were randomly examined thrice by streak retinoscopy pre and post mydriasis.1%cyclopentolate hydrochloride was topically administrated to the eye every five minutes for three times.Main Outcome Measures The eye refraction of guinea pigs included the scope,cylinder and the equivalent power.Results The average refraction of guinea pigs in pre-mydriasis and post-mydriasis were 1.92?0.79 D and 2.08?0.79 D respectively. The average refraction that included the scope,cylinder and the equivalent power all showed no significant difference between pre and post mydriasis.The effect of mydriasis and measure time points on the refraction that included the scope,cylinder and the equivalent scope showed no significant difference either.Conclusions The effect of 1%cyclopentolate cycloplegic on adult guinea pigs in refraction is limited.The refraction of adult guinea pig can be measured naturally without cyclopentolate cycloplegic administrated.

SELECTION OF CITATIONS
SEARCH DETAIL