Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Article in Chinese | WPRIM | ID: wpr-934174

ABSTRACT

Objective:To investigate the application of self-designed wound measuring grid in the measurement of wound and the design of perforator flap.Methods:From February 2018 to February 2020, 31 cases of soft tissue defects of limbs were repaired by free transfer of perforator flap. During the operation, the self-designed membrane with measurement grid was used to measure the wound surface. The flaps were designed and harvested according to the accurate measurement of the wound. The flaps were reviewed at hospital clinic during follow-up.Results:All patients entered 3-15 months of follow-up with an average of 8 months. All 31 flaps survived, of which 2 flaps encountered vascular crisis and were rescued after surgical exploration. There was no infection of flaps and all flaps had stage I healing. The flaps were satisfactory in appearance with the sensation recovery to S 2 in 21 cases and S 3 in 10 cases. Only linear scars were left on the donor sites. Conclusion:The membrane with a measurement grid can accurately measure a wound, and help the design of the flap according to the measured size and profile of the wound. It can reduce the operation time and the risk as well as to improve the operation efficiency. The clinical application is satisfactory. Large scale and multi-centre studies are required to further prove the benefit of the measurement grid.

2.
Chongqing Medicine ; (36): 2606-2608,2612, 2015.
Article in Chinese | WPRIM | ID: wpr-600363

ABSTRACT

Objective To calculate the chest volume for an evaluation of lung development ,the degree of thorax narrowing and pectus excavatum deformity by the surface measurements .Methods Ninety normal Sprague Dawley (4 weeks) rats were ran‐domly divided into experimental and control groups .Experimental group had 70 rats and control group had 20 rats .Cutting off the lower three cartilage from parasternal of rats to produce Pectus excavatum model in experimental groups .We measured many chest radial lines before surgery ,2 ,4 ,8 and 12 weeks after surgery respectively ,then made comparison between parallel group .Thoracic volume size was calculated by a mathematical formula ,Archimedes measurement and the CT three dimensional reconstruction ,and the t test and linear regression were analyzed by SPSS17 .0 .Results this experiment used multiple radial lines to get measurement results ,and through mathematical calculations ,Archimedes measurement and CT reconstruction ,we found there were significant differences between the experimental group and the control group (P<0 .05) .Conclusion It is practicable of surface measurement to calculate chest volume .This method could replace the CT examination to evaluate the change of the chest volume along the process of pectus excavatum formation .

SELECTION OF CITATIONS
SEARCH DETAIL