Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Indian J Ophthalmol ; 2023 Jul; 71(7): 2704-2710
Article | IMSEAR | ID: sea-225134

ABSTRACT

Purpose: To compare the tear meniscus height (TMH) and tear meniscus depth (TMD) between medically controlled glaucoma subjects and age?matched controls. Methods: This prospective, cross?sectional, observational study included 50 patients with medically controlled glaucoma and 50 age?matched controls. Glaucoma subjects using topical medications for the duration of more than 1 year were included. The age?matched controls were participants with no history of glaucoma, dry eye, or any other diseases affecting the ocular surface. All the participants underwent TMH and TMD scan using spectral domain?optical coherence tomography (SD?OCT), which was followed by ocular surface disease index (OSDI) questionnaire administration. Results: The mean ages of glaucoma subjects and age?matched controls were 40 ± 22 and 39 ± 21 years, respectively (P > 0.05). Of them, 40% (n = 22) were on single drug therapy or monotherapy and 60% (n = 28) were on multidrug therapy. TMH and TMD of glaucoma subjects and age?matched controls were 101.27 ± 31.86 versus 230.63 ± 49.82 ?m and 70.60 ± 27.41 versus 167.37 ± 57.06 ?m, respectively. Subjects on multidrug therapy showed a statistically significant reduction in TMH and TMD when compared to age?matched controls. Conclusion: Preservative containing topical glaucoma medications affects the ocular surface, including the tear film. The prolonged duration and multiple combination of this drug usage serve as potential factors for causing reduction in the tear meniscus levels leading to drug?induced dryness

2.
International Eye Science ; (12): 864-866, 2023.
Article in Chinese | WPRIM | ID: wpr-972418

ABSTRACT

AIM: To explore the difference of tear film stability among different lipid layer thickness.METHOD: A total of 194 dry eye patients(384 eyes)admitted to our hospital from June 2020 to December 2021 were enrolled in this study. The tear meniscus height, the first tear film break-up time and lipid layer thickness were measured by corneal topographer. The tear meniscus height and the first tear film break-up time among different lipid layer thickness were compared and the correlation between them was analyzed.RESULTS: The included patients(384 eyes)were divided into lipid rich group(49 eyes), lipid balance group(27 eyes), slight lipid deficiency group(266 eyes)and significant lipid deficiency group(42 eyes)according to the lipid layer thickness. The differences of the tear meniscus height were statistically different(P=0.022), while the differences of the first tear film break-up time were not statistically different(P=0.322). The lipid layer thickness was positively correlated with tear meniscus height(rs=0.143, P=0.006). There was no correlation between lipid layer thickness and the first tear film break-up time(rs=-0.090, P=0.083), nor was there correlation between tear meniscus height and the first tear film break-up time(rs=0.038, P=0.460).CONCLUSION: There was no significant difference in tear film stability in dry eye patients with different lipid layer thickness.

3.
International Eye Science ; (12): 517-521, 2023.
Article in Chinese | WPRIM | ID: wpr-964260

ABSTRACT

AIM:To explore the correlation and consistency of three tear assessment methods in the diagnosis of dry eye, which include the Schirmer Ⅰ test(SⅠt), tear meniscus height(TMH)measurement and a new generation of tear detection technology-Strip meniscometry tube(SMTube).METHODS: A diagnostic test study. A total of 183 dry eye outpatients(183 right eyes)in the Dry Eye Center of Henan Eye Hospital were enrolled from May to June 2021. The SⅠt, TMH and SMTube were performed on all patients, and the correlation and consistency of the measurement results were analyzed.RESULTS:The ocular surface disease index(OSDI)of all included patients was 43.75(31.25, 58.33), noninvasive breakup time(NIBUT)was 7.26(4.97, 9.37)s, and the results of SⅠt, TMH and SMTube were 6(2, 12)mm/5min, 0.18(0.14, 0.22)mm and 5(3,8)mm/5s, respectively; The results of correlation analysis: TMH was positively correlated with SMTube(rs=0.751, P<0.001), however, SⅠt had no correlation with TMH(rs=0.139, P=0.060)and SMTube(rs=0.019, P=0.799). The results of consistency analysis: TMH showed good consistency with SMTube(Kappa=0.794, P=0.044), however, SⅠt showed poor consistency with TMH(Kappa=0.271, P=0.074)and SMTube(Kappa=0.193, P=0.070)respectively.CONCLUSION:SMTube is a new, simple and convenient tool for evaluating tear volume. It has a good correlation and consistency with TMH measurement results. Therefore, it can replace TMH measurement, but cannot replace SⅠt in clinical application.

4.
Chinese Acupuncture & Moxibustion ; (12): 1235-1238, 2023.
Article in English | WPRIM | ID: wpr-1007478

ABSTRACT

OBJECTIVES@#To compare the clinical efficacy and safety of acupuncture and sodium hyaluronate eye drop in the treatment of aqueous deficiency dry eye.@*METHODS@#A total of 60 patients (120 eyes) with aqueous deficiency dry eye were randomly divided into an observation group (30 cases, 1 case dropped out) and a control group (30 cases, 1 case dropped out). In the control group, sodium hyaluronate eye drop were used, one drop at a time, 4 times a day, for 14 consecutive days. In the observation group, acupuncture was applied at bilateral Shangjingming (Extra), Cuanzhu (BL 2), Sizhukong (TE 23), Taiyang (EX-HN 5), and Tongziliao (GB 1) , once a day, treatment for 6 days with the interval of 1 day was required, for 14 consecutive days. The tear meniscus height (TMH), Schirmer Ⅰ test (SⅠT), ocular surface disease index (OSDI) score, non-invasive tear break-up time (NIBUT), and corneal fluorescein sodium staining (FLS) score were compared between the two groups before and after treatment, and the safety of the treatment of the two groups was observed.@*RESULTS@#Compared with those before treatment, after treatment, TMH, SⅠT and NIBUT were increased (P<0.01, P<0.05), and FLS scores were decreased (P<0.01) in the two groups; the score of OSDI was reduced (P<0.01) in the observation group. After treatment, in the observation group, TMH and SⅠT were higher than those in the control group (P<0.01), and the score of OSDI was lower than that in the control group (P<0.01). No adverse reactions and adverse events were observed in the two groups.@*CONCLUSIONS@#Acupuncture and sodium hyaluronate eye drop can both effectively treat aqueous deficiency dry eye, acupuncture has obvious advantages in improving TMH and basic tear secretion, and reducing the subjective symptoms of patients. Acupuncture for dry eye is safe.


Subject(s)
Humans , Hyaluronic Acid , Acupuncture Therapy , Dry Eye Syndromes/therapy , Eye , Tears , Ophthalmic Solutions , Fluorescein
5.
International Eye Science ; (12): 132-136, 2021.
Article in Chinese | WPRIM | ID: wpr-837731

ABSTRACT

@#AIM: To investigate the diagnostic value of Keratograph 5M for the diagnosis of dry eye(dry eye)tear film grading. <p>METHODS: Totally 100 eyes diagnosed with dry eye by conventional means and 40 non-dry eye eyes with suspected dry eye at the same time were enrolled through OPC. The immediate ocular surface parameters of the above cases were collected by the K5M ocular surface analyzer, including the first tear film rupture time(NIBUTf), the average tear film rupture time(NIBUTav), and the tear river height(TMH)which were utilized to evaluated the diagnostic efficacy of K5M compared to routine ocular surface examination on the index of dry eye tear film. <p>RESULTS: The comparison of NIBUTf, NIBUTav and TMH between dry eye group and non-dry eye group by K5M eye surface comprehensive analyzer showed statistically significant differences(all <i>P</i><0.05). The coincidence rate between the NIBUTf of K5M ocular surface analyzer and the BUT of routine diagnosis was 78.6%, and the area under the ROC curve as well as the standard error were 0.042 and 0.795(<i>P</i><0.01)with 95% confidence interval(0.712, 0.878); The coincidence rate between NIBUTav of K5M and BUT of routine examination diagnosis was 73.6%, and the area under the ROC curve as well as the standard error were 0.853 and 0.033(<i>P</i><0.01), with 95% confidence interval(0.788, 0.917).The coincidence rate between TMH of K5M and the SⅠt of conventional diagnosis was 87.9%, and the area under the ROC curve as well as the standard error were 0.795 and 0.044(<i>P</i><0.01), with the 95% confidence interval(0.709, 0.880). The sensitivity, specificity, correctness index, positive likelihood ratio, negative likelihood ratio, and odds ratio of the exploratory diagnosis of dry eye by NIBUTf combined with TMH were 98, 40, 38, 1.63, 0.05, and 32.6%, respectively. The sensitivity, specificity, correctness index, positive likelihood ratio, negative likelihood ratio, and odds ratio of the exploratory diagnosis of dry eye by NIBUTav combined with TMH were 86, 75, 61, 3.44, 0.187, 18.39%, respectively.<p>CONCLUSION: K5M ocular surface analyzer can provide accurate and reliable diagnostic value for single tear film index grading diagnosis of dry eye; compared with TMH combined with NIBUTav, TMH combined with NIBUTf was more sensitive but less specific in diagnosing dry eye.

6.
International Eye Science ; (12): 2175-2177, 2020.
Article in Chinese | WPRIM | ID: wpr-829729

ABSTRACT

@#AIM: To evaluate ocular surface functions in pregnant women with gestational diabetes mellitus(GDM)using Keratogragh 5M. <p>METHODS: Pregnant women with GDM and normal pregnant women were enrolled. All subjects were asked to answer ocular surface disease index(OSDI)questionnaire survey, and then underwent ophthalmic examination including tear meniscus height(TMH), average noninvasive Keratograph tear film break-up time(NIKBUTav), ocular redness analysis, and meibomial gland analysis.<p>RESULTS: There were no statistically significant differences in OSDI, TMH, NIKBUTav, eye redness analysis and meibomial gland analysis between the GDM group and the normal pregnant group(<i>P</i>>0.05). The OSDI scores were 8.02±4.25 and 7.50±4.28(<i>P</i>=0.557), TMH values were 0.22±0.05 and 0.20±0.04mm(<i>P</i>=0.158), NIKBUTav values were 8.01±2.15s and 8.02±1.53s(<i>P</i>=0.971).<p>CONCLUSION: There was no statistically significant difference between the GDM group and the normal pregnant group in ocular surface indexes. GDM had no negative effects on ocular surface, which may be related to good controlling of the blood glucose.

7.
International Eye Science ; (12): 1279-1282, 2020.
Article in Chinese | WPRIM | ID: wpr-822260

ABSTRACT

@#AIM: To evaluate the clinical significance of outer zona pellucid in tear ferning image in dry eye patients and explore a new method for evaluation tear lipid layer. <p>METHODS:Forty-seven patients were randomly selected from the outpatient department of ophthalmology, He Eye hospital, Shenyang from May 2018 to July 2019. The right eye was selected as the study object. All patients were investigated by the ocular surface disease index(OSDI)questionnaire and performed lipid layer classification by DR-1 tear interferometry, NIBUT and tear meniscus height examination by OCULUS Keratograph. Then tears were collected and tear ferning tests was performed. The whole tear crystallization images were observed and photographed by microscopy, then measured by Digimizer software and the area ratios of outer transparent belt were calculated. Pearson correlation analysis were performed between area ratios of outer transparent belt and OSDI scores, lipid layer levels, tear meniscus height values, NIBUT values. <p>RESULTS: The area ratios of outer transparent belt were negatively correlated with OSDI scores(<i>r</i>=-0.764, <i>P</i><0.05), negatively correlated with lipid layer levels(<i>r</i>=-0.838, <i>P</i><0.05), positively correlated with NIBUT values(<i>r</i>=0.575, <i>P</i><0.05)and the correlation between tear meniscus height values was not significantly(<i>r</i>=-0.237, <i>P</i>=0.112). <p>CONCLUSION: The outer transparent belt in tear crystallization image can be used to evaluate the lipid layer of tear film; the larger area ratios of outer transparent belt, the thicker the lipid layer. This method has the advantages of quantified results, good repeatability, low requirement on equipment, and is worth popularizing.

8.
Ciênc. rural (Online) ; 49(11): e20181002, 2019. tab, graf
Article in English | LILACS | ID: biblio-1045262

ABSTRACT

ABSTRACT: This study aimed to describe strip meniscometry test values for Amazona aestiva (turquoise-fronted amazon), Ara ararauna (blue-and-yellow macaw) and Caiman latirostris (broad-snouted caiman). Twenty-one Amazona aestiva and 11 Ara ararauna, healthy, adults of unknown sex, and 37 healthy adult Caiman latirostris (27 males and 10 females), were used in this investigation. All animals were manually restrained and I-Tear® Test strip was inserted for 5 s at the edge of the lower tear meniscus, without touching the eyelid or ocular surface, immediately followed by measurement (millimeter per 5 seconds). No differences were reported between left and right eyes for Amazona aestiva (P = 0.824), Ara ararauna (P = 0.262) and Caiman latirostris (P = 0.679). Median and confidence interval were 2.0 (2.25-3.56) mm/5s for Amazona aestiva, 3.0 (2.93-4.15) mm/5s for Ara ararauna and 3.0 (2.55-4.90) mm/5 s for Caiman latirostris. These values for strip meniscometry tear test can be used as parameters for each species and may be helpful for diagnosis and treatment of tear-production disorders in birds and reptiles.


RESUMO: O objetivo deste estudo foi descrever os valores do teste de meniscometria lacrimal para Amazona aestiva (papagaio-verdadeiro), Ara ararauna (arara-canindé) e Caiman latirostris (jacaré-de-papo-amarelo). Vinte e um Amazona aestiva, 11 Ara ararauna adultos, de sexo desconhecido, e 37 Caiman latirostris adultos (27 machos e 10 fêmeas), foram utilizados nesta investigação. Todos os animais foram contidos manualmente e uma tira do I-Tear® test foi inserida por 5 segundos na borda do menisco inferior, sem tocar a pálpebra ou a superfície ocular, e imediatamente mensurada (milímetro por 5 segundos). Não foram encontradas diferenças entre os olhos esquerdos e direitos para Amazona aestiva (P = 0,824), Ara ararauna (P = 0,262) e Caiman latirostris (P = 0,679). Mediana e intervalo de confiança foram de 2,0 (2,25-3,56) mm/5 s para Amazona aestiva, 3,0 (2,93-4,15) mm/5 s para Ara ararauna e 3,0 (2,55-4,90) mm/5 s para Caiman latirostris. Estes valores para o teste de meniscometria podem ser utilizados como parâmetros para estas espécies e podem ser úteis para diagnosticar e tratar distúrbios de produção lacrimal em aves e répteis.

9.
Journal of the Korean Ophthalmological Society ; : 929-934, 2019.
Article in Korean | WPRIM | ID: wpr-766840

ABSTRACT

PURPOSE: To evaluate the repeatability and reproducibility of inferior tear meniscus measurements using two different spectral domain-optical coherence tomography (OCT), and to compare the inter-device agreements between these devices. METHODS: Two examiners evaluated the tear meniscus depth (TMD) and tear meniscus height (TMH) of 20 eyes in 20 normal subjects using Cirrus OCT and Spectralis OCT with the examiners calculating the TMD and TMH. We analyzed intra-examiner repeatability, inter-examiner reproducibility, and inter-device agreement. RESULTS: The average TMD measurements using the Cirrus OCT and Spectralis OCT devices were 151.25 ± 41.53 µm and 139.10 ± 40.56 µm by examiner 1, respectively, and 152.03 ± 42.77 µm and 138.35 ± 39.70 µm by examiner 2, respectively. The TMHs were 291.90 ± 100.19 µm and 245.43 ± 66.44 µm by examiner 1, respectively, and 288.25 ± 98.72 µm and 244.23 ± 60.69 µm by examiner 2, respectively. The TMDs and TMHs measured using these OCT devices were not statistically significant for intra-examiner and inter-examiner measurements (all, p > 0.05). These devices showed high repeatability (intraclass correlation coefficient ≥ 0.991) for intra-examiner TMD and TMH measurements and the inter-examiner coefficient of variation ranged from 2.04% to 4.32%. The 95% limits of agreement between the two devices were −66.13 to 91.95 µm for TMD and −127.18 to 217.68 µm for TMH. CONCLUSIONS: Both OCT devices are useful for conducting inferior tear meniscus measurements. The inter-device agreement was poor, and the devices were not interchangeable.


Subject(s)
Tears
10.
International Eye Science ; (12): 1191-1195, 2019.
Article in Chinese | WPRIM | ID: wpr-742623

ABSTRACT

@#AIM: To observe the agreement of the lower tear meniscus height(LTMH)measurements using RTVue XR and Keratograph ocular surface analyzer, and to compare intraobserver repeatability and interobserver reproducibility between the two devices in the virginal and FS-LASIK eyes. <p>METHODS: Totally 52 virginal eyes and 52 FS-LASIK eyes were included during January 2019 in Guangzhou Aier Eye Hospital. LTMH measurements were performed using RTVue XR and Keratograph Ocular Surface Analyzer. A paired <i>t</i>-test was used to compare the difference between LTMH values using the two devices. The with-subject standard deviation(Sw), test-retest repeatability(2.77Sw), coefficient of variation(CoV)and intraclass correlation coefficient(ICC)were calculated to evaluate the repeatability and reproducibility. <p>RESULTS: In the virginal eyes group, the average LTMH obtained with RTVue XR and Keratograph were 261.12±80.29μm and 235.05±78.40μm, respectively. CoV and ICC were 5.55% and 0.98 for RTVue XR, 14.90% and 0.87 for Keratograph, respectively. In the FS-LASIK group, the average LTMH were 234.55±68.38μm and 208.22±73.85μm, respectively. CoV and ICC were 5.29% and 0.97 for RTVue XR, 16.16% and 0.87 for Keratograph, respectively. <p>CONCLUSION: In the virginal and FS-LASIK eyes, the LTMH value obtained with RTVue XR is 25μm greater than Keratograph. RTVue XR has a better reliability than Keratograph and can be used to measure the LTMH.

11.
Chinese Journal of Experimental Ophthalmology ; (12): 532-539, 2019.
Article in Chinese | WPRIM | ID: wpr-753193

ABSTRACT

Objective To evaluate the application of the lower tear meniscus parameters measured by anterior segment optical coherence tomography (AS-OCT) in dry eye diagnosis.Methods A prospective randomized clinical controlled study was conducted.One hundred and thirteen dry eye patients (226 eyes) and 206 healthy volunteers (410 eyes) were enrolled from May 2015 to October 2016 in Shanxi Eye Hospital.The lower tear meniscus height (LTMH),lower tear meniscus area (LTMA),lower tear meniscus depth (LTMD),the corneal epithelial thickness (CET) at central 6 mm and the corneal thickness at central 6 mm were measured by RTVue-XR.The measurement results of the two groups were compared and the ROC curve was drawn.The dry eye group and the control group were divided into four age groups:>20-30 years old,>30-40 years old,>40-50 years old and >50-60 years old.The changes of the parameters of the tear crescent in different age groups were compared.The changes of the lower tear meniscus with age were analyzed by linear regression equation.This study was approved by the Ethics Committee of Shanxi Eye Hospital.All operations were performed in accordance with the Helsinki Declaration,and written informed consent was obtained from each subject prior to any medical examination.Results The values of LTMH,LTMD and LTMA in dry eye group were (216.08±67.26) μm,(116.50±29.13) μm,(0.012 9±0.006 7) mm2,respectively,which were lower than (333.71±50.38) μm,(139.56±28.76) μm,(0.026 6±0.007 4)mm2 in control group,with statistical significance between the two groups (all at P<0.05).The CET values of each quadrant in the central area of 2 mm,2-5 mm and 5-6 mm in the dry eye group were significantly lower than those in the control group,with statistically significant differences between the two groups (all at P<0.05).The corneal thickness of central 5-6 mm region,1/8 above the superior nasal quadrant in the central range of 2-5 mm and 1/8 above the superior quadrant was not statistically significant between the two group (all at P>0.05);the corneal thickness values of the other quadrant in dry eye groups were lower than those in control group,the differences were statistically significant (all at P<0.05).The cut-off values of LTMH,LTMD,LTMA,CET at central 2 mm and corneal thickness at central 2 mm were 269.83 μm,122.02 μm,0.023 2 mm2,54.16 μm,531.50 μm,respectively,the sensitivity were 85.4%,88.9% 96.5%,77.0%,66.8%,respectively;the specificity were 91.7%,70.5%,75.1%,56.8%,59.8%,respectively.The values of LTMA,LTMH and LTMD in each age group of dry eye group were significantly lower than those of the control group (all at P<0.05).Linear regression analysis showed that LTMH was decreased by 3.966 μm and LTMD was decreased by 2.381 μm along with the increase of 1 year age in the control group,while LTMH was decreased by 1.293 μm along with the increase of 1 year age in the dry eye group.Compared with the control group,the area of the lower tear crescent image in the dry eye group was reduced,the boundary line was blurred and the coherence was poor in varying degrees,and the turbidity of the tear was increased.Conclusions AS-0CT can objectively reflect the shape of the lower tear meniscus parameters,central CET and central corneal thickness changes.The LTMH and LTMD of normal people are decreased with the increase of age.LTMA and LTMH have high diagnostic efficacy for dry eye and are expected to become one of the important methods for dry eye screening.

12.
Indian J Ophthalmol ; 2018 May; 66(5): 653-656
Article | IMSEAR | ID: sea-196698

ABSTRACT

Purpose: The purpose is to study the correlation between dry eye and refractive errors in young adults using noninvasive Keratograph. Methods: In this cross sectional study, a total of 126 participants in the age range of 19� years and who were free of ocular surface disease, were recruited from King Saud University Campus. Refraction was defined by the spherical equivalent (SE) as the following: 49 emmetropic eyes (�50 SE), 48 myopic eyes (??0.75 SE and above), and 31 hyperopic eyes (>+0.75 SE). All participants underwent full ophthalmic examinations assessing their refractive status and dryness level including noninvasive breakup time (NIBUT) and tear meniscus height using Keratograph 4. Results: The prevalence of dry eye was 24.6%, 36.5%, and 17.4% in emmetropes, myopes, and hypermetropes, respectively. NIBUT has a negative correlation with hyperopia and a positive correlation with myopia with a significant reduction in the average NIBUT in myopes and hypermetropes in comparison to emmetropes. Conclusion: The current results succeeded to demonstrate a correlation between refractive errors and dryness level.

13.
Korean Journal of Ophthalmology ; : 438-444, 2018.
Article in English | WPRIM | ID: wpr-719170

ABSTRACT

PURPOSE: To compare the success rates of performing only silicone tube intubation versus carrying out both conjunctival resection and silicone tube intubation. METHODS: The subjects of this study involved 62 patients (96 eyes) between October 2015 and May 2017 who were diagnosed as having punctal stricture or nasolacrimal duct stenosis. Out of 96 eyes, 47 underwent only silicone tube intubation, and 49 underwent both silicone tube intubation and conjunctival resection. Three parameters were measured at 1, 3, and 6 months after the surgery: the area of the tear meniscus using RTVue-100 anterior segment optical coherence tomography, the height of the tear meniscus using a slit lamp microscope, and the subjective satisfaction of patients as a result of improved sympotms like epiphora. The surgery was considered successful when the patients' experienced the resolution of symptoms and reduction of the area and height of the tear meniscus. RESULTS: The area of the tear meniscus, height of the tear meniscus, and subjective satisfaction of patients was superior in the group that underwent both silicone tube intubation and conjunctival resection compared silicone tube intubation only. Based on these results, the success rate of the surgery was 68.9% in the group that underwent only silicone tube intubation and 78.7% in the group that underwent both silicone tube intubation and conjunctival resection. CONCLUSIONS: The resection of relaxed plica semilunares seems to increase the success rate of silicone tube intubation through the reduction of the area and height of the tear meniscus. Therefore, after determining the degree of conjunctivochalasis, if it was found to be severe, a combination with conjunctival resection was expected to increase the success rate of the surgery.


Subject(s)
Humans , Constriction, Pathologic , Intubation , Lacrimal Apparatus Diseases , Nasolacrimal Duct , Silicon , Silicones , Slit Lamp , Tears , Tomography, Optical Coherence
14.
Journal of Zhejiang University. Science. B ; (12): 218-226, 2018.
Article in English | WPRIM | ID: wpr-1010382

ABSTRACT

OBJECTIVE@#To assess the lower tear meniscus height (LTMH), central tear film thickness (CTFT), and central corneal epithelial thickness (CCET) after deep anterior lamellar keratoplasty (DALK).@*METHODS@#This was a retrospective cross-sectional study of 20 patients who had DALK in one eye over a three-month period. LTMH, CTFT, and CCET of the operated eyes and the unoperated fellow eyes were measured using high-definition optical coherence tomography (HD-OCT). Correlations between three OCT assessments and age, time following surgery, graft size, bed size, and the number of residual sutures were analyzed.@*RESULTS@#Compared to patients with keratoconus, patients with other corneal conditions had significantly higher CCET in the fellow eye (P=0.024). For all patients, CCET in the operated eye was significantly negatively correlated with the number of residual sutures (R=-0.579, P=0.008), and was significantly positively correlated with time following surgery (R=0.636, P=0.003). In the fellow eye, a significant positive correlation was found between age and CCET (R=0.551, P=0.012), and a significant negative correlation between age and CTFT (R=-0.491, P=0.028). LTMH was found to be significantly correlated between operated and fellow eyes (R=0.554, P=0.011). There was no significant correlation between LTMH and age, bed/graft size, time following surgery, or residual sutures (all possible correlations, P>0.05).@*CONCLUSIONS@#Patients with keratoconus tend to have a thinner central corneal epithelium. Corneal epithelium keeps regenerating over time after DALK. DALK did not induce a significant change in tear volume compared with the fellow eye. Postoperative tear function might depend on an individual's general condition, rather than on age, gender, bed/graft size, time following surgery, or residual sutures.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Corneal Transplantation , Cross-Sectional Studies , Epithelium, Corneal/pathology , Retrospective Studies , Tears , Tomography, Optical Coherence
15.
International Eye Science ; (12): 765-768, 2018.
Article in Chinese | WPRIM | ID: wpr-695303

ABSTRACT

·AIM:To evaluate the ocular surface in the patients after strabismus surgery. ·METHODS: One hundred and eighty-eight hospitalized patients (240 eyes) with strabismus from May 2015 to October 2016 in Aier Hospital were divided into 3 groups according to the type of incision:85 cases(100 eyes) with the corneal limbus incision in Group A;35 cases(50 eyes) with the cross-muscle incision in Group B; 68 cases (90 eyes) with the adjacent-fornix incision (including Parks incisions and improved Parks incisions) in Group C. And 75 eyes with single extraoeular muscle surgery, 110 eyes with 2 extraoeular muscle surgery, 55 cases with 3 extraoeular muscle surgery. The first noninvasive tear film break-up time (NITBUTf) and the tear meniscus height (TMH) were tested by Oculus anterior segment analyzer preoperatively and 1d, 1, 2 and 4wk postoperatively. The data were studied by statistics. · RESULTS: Comparing with preoperative, TMH increased significantly at post-operatively 1d in all group, NIKBUTf reduced significantly(P<0.05). NIKBUTf was recovered in Group A at post-operative 2wk. NIKBUTf were recovered in Group B and C at post-operative 1wk. TMH were recovered in Group A and B at post-operative 2wk. TMH was recovered in Group C at post-operative 1wk. NIKBUTf and TMH were recovered with the single extraoeular muscle surgery at post-operative 1wk. They were recovered at post-operative 2wk with the 2 and 3 extraoeular muscle surgery. ·CONCLUSION: Surgical incision and surgical muscle number may affect the ocular surface of the people after strabismus surgery. The adjacent fornix conjunctival incision has less effect. The less number of muscles in strabismus surgery,the less effect on ocular surface.

16.
International Eye Science ; (12): 1625-1630, 2017.
Article in Chinese | WPRIM | ID: wpr-641375

ABSTRACT

AIM:To compare the non-invasive tear break-up time (NITBUT) and tear meniscus height (TMH) measurements in keratoconus patients and normal subjects, and to determine the relationship between these measurements with keratoconus disease by the Oculus Keratograph 5M (K5M).METHODS:Fifty keratoconus patients (100 eyes) and 50 healthy subjects (100 eyes) participated in the study.The age range in keratoconus group was 15-60(mean ± standard deviation=28.33±8.60) y, and in control group was 18-60(26.25±1.11) y.The measurements of NITBUT and TMH were performed using the K5M.RESULTS:The mean value of NITBUT between the keratoconus group and the control group showed no statistically significant different (P=0.58).Also, the mean of TMH between two groups was not significantly different (P=0.69).The results of correlation coefficient between the variables of the study demonstrated that there was no significant relationship between the NITBUT and TMH measurements with the two groups (keratoconus group:r=0.053, P=0.721;control group;r=-0.0501, P=0.7098).CONCLUSION:Our study shows that the presence of keratoconus has no clinically significant impact on the quality and quantity of tear film.

17.
Korean Journal of Ophthalmology ; : 306-312, 2017.
Article in English | WPRIM | ID: wpr-69353

ABSTRACT

PURPOSE: To evaluate changes in the tear meniscus area and tear meniscus height over time in patients with dry eye syndrome, using anterior segment spectral-domain optical coherence tomography after the instillation of 3% diquafosol ophthalmic solution. METHODS: Sixty eyes from 30 patients with mild to moderate dry eye syndrome were included. Tear meniscus images acquired by anterior segment spectral-domain optical coherence tomography were analyzed using National Institutes of Health's image-analysis software (ImageJ 1.44p). Tear meniscus area and tear meniscus height were measured at baseline, 5 minutes, 10 minutes, and 30 minutes after instillation of a drop of diquafosol in one eye and normal saline in the other eye. Changes in ocular surface disease index score, tear film break-up time, corneal staining score by Oxford schema, and meibomian expressibility were also evaluated at baseline, and after 1 week and 1 month of a diquafosol daily regimen. RESULTS: Sixty eyes from 30 subjects (mean age, 29.3 years; 8 men and 22 women) were included. In eyes receiving diquafosol, tear volume was increased at 5 and 10 minutes compared with baseline. It was also higher than saline instilled eyes at 5, 10, and 30 minutes. Changes in tear volume with respect to baseline were not statistically different after the use of diquafosol for 1 month. Ocular surface disease index score, tear film break-up time, and Oxford cornea stain score were significantly improved after 1 week and 1 month of daily diquafosol instillation, but meibomian expressibility did not change. CONCLUSIONS: Topical diquafosol ophthalmic solution effectively increased tear volume for up to 30 minutes, compared to normal saline in patients with dry eye syndrome.


Subject(s)
Humans , Male , Academies and Institutes , Cornea , Dry Eye Syndromes , Ophthalmic Solutions , Purinergic P2Y Receptor Agonists , Tears , Tomography, Optical Coherence
18.
Journal of the Korean Ophthalmological Society ; : 1932-1938, 2016.
Article in Korean | WPRIM | ID: wpr-124575

ABSTRACT

PURPOSE: In this study, the changes in ocular surface parameters and tear meniscus after strabismus surgery when treated with or without artificial tears were evaluated using optical coherence tomography (OCT). METHODS: The present study included 30 patients who received bilateral lateral rectus recession surgery for exotropia. The patients instilled artificial tear eye drops only in the left eye. Before and 2, 4, 8, and 12 weeks after surgery, tear film break-up time (BUT), Schirmer's test, corneal staining test, tear meniscus height and area were measured using OCT and compared in both eyes. Before and 8 weeks after surgery, conjunctival compression cytology test was performed. RESULTS: The mean patient age was 8.7 years. After 8 weeks, BUT and corneal staining scores were 12.3 ± 1.5 seconds and 1.3 ± 0.4 in patients treated with artificial tears and 9.5 ± 1.0 seconds and 2.0 ± 0.7 in patients not treated with artificial tears (both p < 0.000). Four weeks after surgery, tear meniscus height and area using OCT were 290.2 ± 42.3 µm and 566.7 ± 48.2 pixels in patients treated with artificial tears and 246 ± 45.5 µm and 504.0 ± 29.7 pixels in patients not treated with artificial tears (p = 0.045 and p = 0.019, respectively). Goblet cell count was significantly different between the eyes 8 weeks after surgery (p = 0.033). CONCLUSIONS: Instability of tear meniscus can be detected after strabismus surgery using BUT, Schirmer's test, corneal staining test, tear meniscus height and area, and OCT. After surgery, artificial tears help treat dry eye symptoms by corneo-conjunctival wound healing mechanism and increasing tear meniscus stability.


Subject(s)
Humans , Exotropia , Goblet Cells , Lubricant Eye Drops , Ophthalmic Solutions , Strabismus , Tears , Tomography, Optical Coherence , Wound Healing
19.
Journal of the Korean Ophthalmological Society ; : 509-514, 2015.
Article in Korean | WPRIM | ID: wpr-203443

ABSTRACT

PURPOSE: To evaluate cross-sectional areas of conjunctiva and tear meniscus of conjunctivochalasis using Fourier-Domain RTVue-100 optical coherence tomography (OCT) before and after conjunctivochalasis surgery. METHODS: Thirty-one patients (33 eyes) with symptomatic conjunctivochalasis were recruited for this study between June 2013 and April 2014. All patients underwent crescent-shaped conjunctiva resection and amniotic membrane transplantation. Anterior segment OCT (AS-OCT) imaging was performed and tear break-up time was evaluated prior to and 3 months after the conjunctivochalasis surgery. Cross-sectional areas of conjunctiva and tear meniscus of conjunctivochalasis at 7 locations (1 center, 3 nasal and 3 temporal areas) were measured in all patients. RESULTS: The mean age of patients was 66.3 +/- 10.8 years. Cross-sectional areas of conjunctivochalasis at all locations significantly decreased from 0.487 +/- 0.42 mm2 to 0.007 +/- 0.011 mm2 (p < 0.001), whereas no significant changes in cross-sectional areas of tear meniscus at all 7 locations were observed after the surgery. Mean tear break-up time significantly increased from 2.26 +/- 0.69 sec to 3.81 +/- 1.22 sec following the surgery. CONCLUSIONS: Using AS-OCT, in this study we showed that areas of conjunctiva decreased and areas of tear meniscus were unchanged after conjunctivochalasis surgery.


Subject(s)
Humans , Amnion , Conjunctiva , Tears , Tomography, Optical Coherence
20.
Journal of the Korean Ophthalmological Society ; : 1684-1691, 2015.
Article in Korean | WPRIM | ID: wpr-213420

ABSTRACT

PURPOSE: This study compared tear meniscus parameters between normal control, aqueous tear deficient dry eye, and meibomein gland dysfunction groups using Fourier-domain optical coherence tomography (FD-OCT). METHODS: This study included 33 normal eyes, 79 aqueous tear-deficient dry eyes (ATD), and 48 meibomein gland dysfunction dry eyes (MGD). Following routine examination including Schirmer test, tear break-up time, corneal staining, and tear meniscus parameters such as tear meniscus height (TMH), tear meniscus depth (TMD), and tear meniscus area (TMA) were obtained using FD-OCT. The differences among groups were assessed. RESULTS: The averages of TMH, TMD, and TMA were 295.58 +/- 58.36 microm, 166.67 +/- 30.43 microm, and 0.0360 +/- 0.01100 mm2 in normal eyes, respectively, 226.43 +/- 42.18 microm, 147.44 +/- 38.38 microm, and 0.0209 +/- 0.01015 mm2 in ATD, respectively, 272.81 +/- 64.21 microm, 159.37 +/- 44.05 microm, and 0.0295 +/- 0.01271 mm2 in MGD, respectively. Tear meniscus parameters were significantly lower in ATD. Tear meniscus parameters in MGD were higher than ATD and lower than normal eyes, but the TMA was the only statistically significant value. CONCLUSIONS: Although tear meniscus parameters in MGD were higher than ATD, they could not be distinguished from normal eyes. Tear meniscus evaluation using FD-OCT could be a useful measurement system in classification and treatment choice for dry eye patients.


Subject(s)
Humans , Classification , Dry Eye Syndromes , Tears , Tomography, Optical Coherence
SELECTION OF CITATIONS
SEARCH DETAIL