Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
International Eye Science ; (12): 1702-1706, 2022.
Article in Chinese | WPRIM | ID: wpr-942845

ABSTRACT

AIM: To analyze the stability of different concentrations of fluorescein sodium solution on the detection of tear break-up time(TBUT).METHODS:A retrospective study. A total of 150 cases(150 eyes)who came to our dry eye clinic with good cooperation from August 2019 to September 2021 were selected for the study, and the subjects were randomly divided into five groups, which were fluorescein sodium(FLS, 0.5%), FLS(1.0%), FLS(1.5%), FLS(2.0%)and fluorescein sodium parallel(FLSP), with 30 patients in each group(all the right eyes were the subject eyes). Each group was dripped with the corresponding fluorescein sodium. The FLSP group was the fluorescent test strip detection group. The slit lamp image scores of different concentration groups were compared, the survival time of sodium fluorescein at the instant, 2, 5, 10, 15 and 30min points was observed in each group, and the mean value of TBUT in each group was recorded.RESULTS: The image score of FLS(0.5%)group was significantly higher than that of the other four groups(t=7.746, 21.483, 116.190, 38.730, all P<0.01). The image score of FLS(1.0%)group was significantly higher than that of FLS(1.5%)and FLS(2.0%)group(t=10.742, 15.492, all P<0.01). The survival time of fluorescein in FLS(0.5%)group was significantly shorter than that of the other four groups(t=8.226, 7.458, 9.159, 12.347, all P<0.01). The survival time of fluorescein in FLS(1.5%)group was significantly longer than that of FLS(1.0%)and FLS(2.0%)group(t=15.428, 13.274, all P<0.05). TBUT in FLS(0.5%)group was significantly higher than that of the other four groups at 2min(t=22.767, 22.345, 15.494, 17.213, all P<0.01), and was significantly lower than that of the other four groups at 10min(t=23.266, 25.353, 10.183, 22.025, all P<0.01). The mean first TBUT of FLS(1.5%)group was significantly shorter than that of the other four groups(t=25.236, 21.374, 19.658, 72.341, all P<0.01), and the mean first TBUT of FLSP group was significantly longer than that of the other four groups(t=22.487, 30.267, 60.247, 40.857, all P<0.01). There was no significant correlation between TBUT and ocular surface disease index(OSDI)and tear river height(rs=-0.072, 0.219, P=0.689, 0.112). TBUT was positively correlated with tear secretion(rs=0.674, P<0.01).CONCLUSION: FLS(0.5%)had higher image quality but it was only suitable for observing staining within 5min, and the FLSP group was more suitable for clinical observation of corneal fluorescence staining for a longer period; FLS(1.5%)was the most stable and reliable concentration and dose for the detection of TBUT.

2.
International Eye Science ; (12): 545-548, 2021.
Article in Chinese | WPRIM | ID: wpr-923263

ABSTRACT

@#AIM: To investigate the effect of blocking short wave visible light(400-500nm)on tear film stability in healthy people. <p>METHODS: In this prospective intervention experiment, 26 college students were selected, including 12 males and 14 females, aged 22.1±1.4 years, from February to March 2020. At the same time of two adjacent days, the subjects watched the video for 1h under the same environmental conditions. For the first time, there was no short wave visible light blocking, and for the second time, they wore short wave visible light blocking myopia or flat glasses. The subjects were examined the radius of curvature of lacrimal River curved surface, tear osmolality, tear film rupture time, corneal fluorescein sodium staining score, the basic state before watching the video and after watching the video respectively. And the questionnaire of visual perception was completed at the end of the experiment. <p>RESULTS: There were significant differences in the radius of curvature of lacrimal River curved surface, tear osmolality, tear film rupture time, corneal fluorescein sodium staining score between the basic state and the short wave visible unstopped state(<i>t</i>=4.50, 5.72, 4.437, 3.245, <i>P</i><0.05). There was no significant difference between the short wave visible light blocking and the basic state(<i>t</i>=1.972, 1.993, 1.921, 1.641, <i>P</i>>0.05). There was also significant difference between the short wave visible light blocking and the short wave visible light unblocking(<i>t</i>=2.825, 3.771, 2.610, 3.028, <i>P</i>< 0.05). The results of the questionnaire showed that: eighteen subjects(69%)said that wearing the short wave visible light blocking glasses or without wearing short wave visible light blocking glasses had slight eye dryness, pain, foreign body sensation, visual fatigue and other discomfort after watching the video. Sixteen subjects(62%)said that they were more comfortable after blocking the short wave visible light. Twenty-four subjects(92%)said that they were willing to block the short wave visible light. <p>CONCLUSION: The stability of tear film could be reduced by watching the display screen for a short time. Blocking the short wave visible light could protect the stability of tear film of the ocular surface.

3.
International Eye Science ; (12): 1187-1190, 2019.
Article in Chinese | WPRIM | ID: wpr-742622

ABSTRACT

@#AIM: To observe the effect of corneal bandage lens on ocular surface repair after pterygium excision combined with limbal stem cell transplantation.<p>METHODS: Totally 52 patients with unilateral primary pterygium were selected from January 2016 to January 2018 in the ophthalmology department of our hospital. All 26 cases(26 eyes)underwent pterygium excision combined with limbal stem cell transplantation and who were placed with bandage lens as the experimental group, the other 26 cases(26 eyes)without bandage lens placed as the control group. Ocular surface disease index(OSDI)questionnaires, tear break-up time(BUT), and corneal fluorescein staining(CFS)were recorded before operation and after operation.<p>RESULTS: BUT in the experimental group was longer than that in the control group(<i>P</i><0.05), OSDI and CFS scores were lower than those in the control group(<i>P</i><0.05)at 2wk, 1mo after operation. Compared with the preoperative situation, BUT in the two groups was shorter, OSDI and CFS scores were higher(<i>P</i><0.05). At 1mo after operation there were no significant differences in BUT, OSDI and CFS between the experimental group and those before the operation(<i>P</i>>0.05), but in the corresponding period, BUT in the control group was still shorter, OSDI and CFS scores were still higher than those before the operation(<i>P</i><0.05).<p>CONCLUSION: Surgical excision combined with autologous limbal stem cell transplantation and placing corneal bandage lens is a safe method to promote corneal healing, improve tear film stability and reduce postoperative discomfort in pterygium patients in the early stage after surgery, which is conducive to the repair of the ocular surface and has certain clinical application value.

4.
International Eye Science ; (12): 366-368, 2017.
Article in Chinese | WPRIM | ID: wpr-731495

ABSTRACT

@#AIM: To investigate the effect of lacrimal passage laser combined with drainage tube implantation on tear film rupture time and corneal fluorescein sodium staining in patients with lacrimal duct obstruction so as to improve the therapeutic effect of lacrimal laser combined drainage tube implantation. <p>METHODS: From January, 2013 to December, 2015, 200 cases(200 eyes)of lacrimal passage obstruction were treated with lacrimal passage laser combined with lacrimal drainage tube implantation in our hospital. Before and 1mo after operation, after the tube was draw out, ocular surface was assessed. The test included tear film rupture time, tear secretion, corneal fluorescein staining and dry eye syndrome questionnaire. <p>RESULTS: There was no significant difference in tear film rupture time between the two groups before and after 1mo, after the tube was draw out(<i>P</i>>0.05). The amount of tear secretion increased at 1mo after operation and the amount of tear secretion decreased after extubation. The difference was statistically significant(<i>P</i><0.05). There was no significant difference in the corneal fluorescein staining before and after operation, after extubation(<i>P</i>>0.05). The dry eye symptom questionnaire showed that the tearing laser combined drainage tube implantation significantly improved the tearing symptoms. <p>CONCLUSION: The lacrimal duct laser combined drainage tube implantation has no significant effect on tear film rupture time and corneal fluorescein sodium staining. This kind of operation can improve the postoperative tearing symptoms of the patients, and is of great significance in the treatment of lacrimal passage obstruction.

SELECTION OF CITATIONS
SEARCH DETAIL