Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Vitae (Medellín) ; 30(1): 1-13, 2023-01-22. Ilustraciones
Article in English | LILACS, COLNAL | ID: biblio-1438341

ABSTRACT

Background: This research was motivated by the determination of the sanitation schedule in the heat exchanger area for some products (milk, avocado juice, and orange juice), as well as the inconsistency of the results of previous studies related to the chemical composition of the fouling layer. Objectives: a) to test the effect of raw material composition on the chemical composition of the fouling layer. b) to test microbial growth's effect on fouling's chemical composition (protein). Methods: mathematical derivation of the formation process of Resistant Dirt Factor (Rd) in the form of an Equation; ANOVA was used to test the effect of the dependent variable (protein) and predictor (microbial). Results: a) The composition of the raw material strongly influences the chemical composition of the fouling layer; b) There is a strong effect between microbial growth and protein content as a fouling composition (p<0.05). Conclusion: A strong influence between microbial growth and the composition of the fouling layer (protein) can close the research gap related to the inconsistency of previous research results (fouling layer composition), so there is no prolonged debate


Antecedentes: Esta investigación fue motivada por la determinación del cronograma de sanitización en el área del intercambiador de calor para diferentes productos (leche, jugo de aguacate y jugo de naranja), así como la inconsistencia de los resultados de estudios previos relacionados con la composición química de la capa de suciedad. Objetivos: a) probar el efecto de la composición de la materia prima sobre la composición química de la capa de suciedad. b) probar el efecto del crecimiento microbiano en la composición química de la capa de suciedad (proteína). Método: etapas del proceso de formación del Factor de Suciedad Resistente (Rd) en forma de una ecuación; Se usó ANOVA para probar el efecto de la variable dependiente (proteína) y el predictor (microbiano). Resultados: a) La composición química de la capa de incrustación está fuertemente influenciada por la composición de la materia prima; b) Existe un fuerte efecto entre el crecimiento microbiano sobre el contenido de proteína como composición de ensuciamiento (p<0.05). Conclusión: Una fuerte influencia entre el crecimiento microbiano y la composición de la capa de incrustación (proteína) puede cerrar la brecha de investigación relacionada con la inconsistencia de los resultados de investigaciones anteriores (composición de la capa de incrustación) para que no haya un debate prolongado


Subject(s)
Humans , Thermal Conductivity , Dairy Products
2.
Rev. bras. med. trab ; 17(1): 136-144, jan-mar.2019.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1000370

ABSTRACT

INTRODUÇÃO: Os setores climatizados, no ramo de indústrias alimentícias, apresentam variações de temperatura de -35 a 12ºC, as quais são necessárias para garantir a qualidade dos alimentos. Entretanto, essa faixa de temperatura pode ser um agente nocivo para a saúde dos trabalhadores. OBJETIVO:Estudar os parâmetros de exposição ocupacional ao risco frio para estimar o índice de isolamento térmico e determinar a eficácia dos equipamentos de proteção individual. MÉTODOS: Na primeira etapa foram avaliadas as variáveis ambientais (temperatura do ar, velocidade do ar, umidade relativa do ar) e a taxa de metabolismo; na segunda etapa foi determinado o índice de isolamento térmico fornecido; e na terceira etapa foi calculado o índice de isolamento básico de vestuário exigido para manter o equilíbrio térmico e verificada a eficácia dos equipamentos de proteção individual. RESULTADOS: Embora a temperatura do ar seja inferior nas atividades desenvolvidas no túnel de congelamento no setor de embalagem secundária, comparando com as atividades realizadas na câmara de estocagem de operar empilhadeira e transportar produtos, o índice de isolamento básico de vestuário exigido é maior nas atividades desenvolvidas com uso de empilhadeira, mesmo a temperatura sendo superior. Isso ocorre em função da velocidade do ar ser superior nas atividades realizadas nas empilhadeiras. CONCLUSÕES: Em 83,3% das atividades avaliadas a proteção se mostrou eficaz, porém, existe a possibilidade dos indivíduos sentirem desconforto térmico devido ao excesso de roupa fornecida. Apesar de a proteção ser insuficiente em 16,7%, as pausas de recuperação térmica eliminam o risco de hipotermia.


BACKGROUND: The temperature of climate controlled areas in the food industry varies from -35ºC to 12ºC to ensure the quality of food. However, this temperature range might be harmful to the health of workers. OBJECTIVE: To analyze parameters related to occupational exposure to cold risks to calculate clothing insulation indices and establish the efficacy of personal protective equipment (PPE). METHODS: In stage 1 we analyzed environmental variables (air temperature and velocity and relative humidity) and the metabolic rate; in stage 2 we calculated the resultant clothing insulation index; in stage 3 we calculated the basic clothing insulation required to maintain the thermal balance and investigated the efficacy of PPE. RESULTS: While the air temperature was lower for activities developed in the freezing tunnel (secondary packaging department), required basic clothing insulation was higher for activities involving operating forklifts. CONCLUSION: Protection was efficacious for 83.3% of the analyzed activities, however, occurrence of thermal discomfort cannot be ruled out as a function of excessive clothing. Although protection was insufficient for 16.7% of the analyzed activities, breaks for thermal recovery neutralized the risk of hypothermia.

3.
Rev. bras. queimaduras ; 17(1): 14-19, jan.-abr. 2018. ilus, quadros
Article in Portuguese | LILACS | ID: biblio-999909

ABSTRACT

Introdução: Queimaduras cutâneas são lesões geralmente causadas pela energia térmica da transferência de calor, que determina um processo cicatricial desordenado. Para entender o processo e para avaliar possibilidades terapêuticas, são necessários modelos animais, assim como a padronização da elaboração da queimadura experimental. Objetivo: Detalhar uma técnica que promove queimaduras padronizadas de espessura total da pele em ratos Wistar. Método: Realizaram-se queimaduras padronizadas em 22 ratos Wistar divididos aleatoriamente em GI e GII. Acoplou-se à extremidade de um ferro de solda uma peça cerâmica de 484mm2 de superfície, que em contato com a pele durante 30 segundos, aquecida a 100° Celsius com uma pressão de 54 gramas, exercida pela própria massa do ferro da solda, determinou as queimaduras. No quarto dia, avaliou-se a coloração, umidade e elasticidade para caracterizar macroscopicamente as queimaduras e mensurou-se a área das queimaduras dos grupos, nos quais aplicou-se o teste t de Student para comparar os resultados. Resultados: Evidenciaram-se, em todos os animais, queimaduras com coloração branca cerosa, seca e inelástica. Constatou-se uma área média das queimaduras 403,5±71,48mm2 no GI e 403,7±71,19mm2 no GII (p=0,995). Conclusão: O contato da peça cerâmica de 484mm2 com pressão de massa de 54 gramas a 100° Celsius durante 30 segundos determinou queimaduras de espessura total de pele com área média semelhante entre os grupos, ao quarto dia de evolução, permitindo comparações seguras entre GI e GII ao longo do tempo cicatricial.


Introduction: Skin burns are lesions usually caused by energy of heat transfer that determine a disordered cicatricial process, to understand it and to evaluate therapeutic possibilities are needed animal models, as well as the standardization of experimental burn. Objective: To describe a technique that promotes standardized burns of total skin thickness for experimental study in Wistar rats. Methods: Standardized burns were performed on 22 Wistar rats randomly divided into GI and GII. A ceramic piece of 484 mm2 was attached to the end of a soldering iron, which in contact with the skin for 30 seconds at 100° Celsius at a pressure of 54 grams. On the fourth day, the staining, moisture and elasticity were evaluated to characterize the burns and the burn area of the groups was measured, in which Students t-test. Results: Burns characterized by waxy, dry and inelastic white color were observed in all the animals. It was found an average area of burns to 403.5±71.48mm2 in GI and 403.7±71.19mm2 in GII (p=0.995). Conclusion: The contact of the ceramic piece of 484mm2 with mass pressure of 54 grams at 100° Celsius for 30 seconds, determined total skin thickness burns with similar mean area groups, on the fourth day, allowing the safe comparison between the groups over the cicatricial time


Introducción: Las quemaduras cutáneas son lesiones en general causadas por la transferencia de calor que determinan una cicatrización desordenado, para entenderlo y evaluar posibilidades terapéuticas, se necesitan modelos animales, así como la estandarización de la quemadura experimental. Objetivo: Describir una técnica que promueve quemaduras estandarizadas del grosor total de la piel para el estudio experimental en ratas Wistar. Métodos: Se realizaron quemaduras en veintidós ratas Wistar divididas aleatoriamente en GI y GII. Se colocó una pieza cerámica de 484mm2 en un soldador en contacto con la piel durante 30 segundos a 100° Celsius a una presión de 54 gramos determinó la quemaduras. En el cuarto día, la tinción, la humedad y la elasticidad se evaluaron para caracterizar las quemaduras y se midió el área de las quemadura y se aplicó la prueba t de Student. Resultados: Se observaron quemaduras caracterizadas por un color blanco ceroso, seco e inelástico en todos los animales. Se encontró un área media de quemaduras 403.5±71.48mm2 en GI y 403.7±71.19 mm2 en GII (p=0.995). Conclusión: El contacto de la pieza de cerámica de 484 mm2 con una presión de masa de 54 gramos a 100° Celsius durante 30 segundos, determinó quemaduras de espesor total de la piel con área media similares entre los grupos en el cuarto día, lo que permite la comparación segura entre GI y el GII a lo largo del tiempo cicatricial


Subject(s)
Animals , Burns , Rats, Wistar , Models, Animal , Methods
4.
Nucleus (La Habana) ; (61): 32-38, Jan.-June 2017.
Article in Spanish | LILACS | ID: biblio-841907

ABSTRACT

El reactor nuclear de agua ligera de alto desempeño es la versión europea del reactor refrigerado por agua supercrítica, propuesto como uno de los candidatos para la Generación IV de reactores nucleares. En este trabajo se evaluó la capacidad para predecir el comportamiento de la transferencia de calor hacia el agua supercrítica en los subcanales de 1/8 del conjunto combustible del HPLWR, mediante códigos de la Dinámica de Fluidos Computacional utilizando dos modelos de turbulencia: el modelo de esfuerzos de Reynolds, desarrollado por Speziale y el modelo k-ω de transporte de esfuerzos cortantes. Se realizó un estudio de sensibilidad de malla que garantizó la independencia de los resultados numéricos respecto del tamaño y distribución de los elementos de la malla. Se calcularon las distribuciones axiales de temperatura en la envoltura y en los elementos combustibles, además de las distribuciones de temperatura del agua en la zona refrigerante y en la zona moderadora. Se compararon los resultados de los dos modelos de turbulencia y se mostró que no se obtuvo ninguna diferencia apreciable en los valores de la temperatura promedio del agua supercrítica calculada con los modelos de turbulencia utilizados. Sin embargo, los resultados numéricos utilizando el modelo de turbulencia SST mostraron mayores valores de temperatura del combustible y de temperatura superficial de la envoltura de los elementos combustibles que los calculados con el modelo SSG


The high-performance light-water nuclear reactor is the European version of the supercritical water-cooled reactor, proposed as one of the candidates for Generation IV of nuclear reactors. This paper assesses the ability to predict the heat transfer behavior to supercritical water in the sub-channels of the 1/8 HPLWR fuel assembly by codes of Computational Fluid Dynamics using two models of turbulence (the Reynolds stress model developed by Speziale and the k-ω shear stress transport model). A mesh sensitivity study was performed to guarantee the independence of the numerical results regardless the size and distribution of the mesh elements. Temperature distributions were calculated in the fuel rods, in the clad, and in water both in the cooling zone and moderator zone. The results of the two turbulence models were compared. No appreciable difference was obtained in the values of the supercritical water average temperature calculated with the turbulence models used. However, the numerical results using the SST turbulence model show higher values regarding the temperature of both fuel rods and clad surface compared to those calculated with the SSG model

5.
Rev. CEFAC ; 17(2): 648-655, Mar-Apr/2015. graf
Article in Portuguese | LILACS | ID: lil-746180

ABSTRACT

Esta pesquisa teve por objetivo realizar uma revisão integrativa sobre a produção científica referente ao uso da crioterapia no tratamento das disfunções temporomandibulares, caracterizando as técnicas utilizadas, duração de aplicação da técnica, área estimulada e frequência de realização. Foi realizado um levantamento da literatura nas bases de dados Medline, LILACS, SciELO, Biblioteca Cochrane e IBECS. Os termos utilizados foram: crioterapia, temperatura baixa, transferência de calor, hipotermia induzida, articulação temporomandibular, transtornos da articulação temporomandibular, síndrome da disfunção da articulação temporomandibular e seus correspondentes em inglês e espanhol. Foram incluídos artigos que abordaram a crioterapia no tratamento das disfunções temporomandibulares, publicados em inglês, espanhol ou português, no período de 1980 a 2013. Foram considerados: técnica de aplicação, duração de aplicação, área corporal e frequência de realização. Inicialmente foram encontrados 34 estudos, dos quais 13 contemplaram os critérios de seleção propostos. Os dados foram tabulados e apresentados em ordem cronológica. A retirada do calor corporal pode ser realizada por meio da aplicação de compressas frias, bolsas com agentes frios ou aerossóis refrigerantes, aplicados sobre as áreas dolorosas, sobre regiões musculares com "trigger points", ou sobre músculos mastigatórios. O tempo médio de aplicação do estímulo variou de 10 a 15 minutos para as bolsas com agentes frios e cerca de 10 segundos no caso do spray refrigerante, repetindo-se cerca de 2 a 4 vezes por dia, precedendo as técnicas de alongamento muscular. A literatura não apresenta um consenso quanto à intensidade do estímulo térmico.


The purpose of this research was to perform an integrative review of scientific bibliographic production on the use of cryotherapy on temporomandibular disorders treatment, highlighting the techniques, duration, stimulated body area and frequency of application. Literature review was accomplished on Medline, LILACS, SciELO, Cochrane Library and IBECS databases. The descriptors used were: Cryotherapy, Cold Temperature, Induced Hypothermia, Heat Transference, Temporomandibular Joint, Temporomandibular Joint Disorders, Temporomandibular Joint Dysfunction Syndrome and their equivalents in Portuguese and Spanish. Articles that addressed the cryotherapy for the treatment of temporomandibular disorders, published in English, Spanish or Portuguese, between 1980 and 2013, were included. The following data were collected: technique, duration of application, stimulated area and frequency of application. Initially, 34 studies were found, but only 13 were about the selection criteria proposed. Data were tabulated and presented in chronological order. The decrease of body heat can be conducted through application of cold compresses, cold bags or vapocoolant sprays applied to the painful areas, trigger points regions, or in masticatory muscles. The average time of application of the stimulus was 10 to 15 minutes for cold bags and about 10 seconds for vapocoolant sprays, repeated approximately 2 to 4 times per day, preceding muscle stretching techniques. The literature has no consensus about the intensity of the thermal stimulus.

6.
CoDAS ; 27(2): 207-212, Mar-Apr/2015. graf
Article in English | LILACS | ID: lil-748853

ABSTRACT

Purpose: To perform an integrative review of scientific bibliographic production on the use of superficial heat treatment for temporomandibular disorders. Research strategy : Literature review was accomplished on PubMed, LiLACS, SciELO, Bireme, Web of Science, and BBO databases. The following descriptors were used: hot temperature, hyperthermia induced, heat transference, temporomandibular joint, temporomandibular joint disorders, temporomandibular joint dysfunction syndrome, and their equivalents in Portuguese and Spanish. Selection criteria : Articles that addressed the superficial heat for the treatment of temporomandibular disorders, published in English, Spanish, or Portuguese, between 1980 and 2013. Data analysis : The following data were collected: technique of applying superficial heat, duration of application, stimulated body area, temperature of the stimulus, frequency of application, and benefits. Results : initially, 211 studies were found, but just 13 contemplated the proposed selection criteria. Data were tabulated and presented in chronological order. Conclusion: Several techniques for superficial heat application on treatment of temporomandibular disorders were found in the literature. The moist heat was the most widely used technique. Many studies suggested the application of heat for at least 20 minutes once a day. Most authors recommended the application of heat in facial and cervical regions. The heat treatment resulted in significant relief of pain, reduced muscle tension, improved function of the mandible, and increased mouth opening. .


Objetivo: Realizar revisão integrativa sobre a produção científica referente ao emprego do calor superficial para tratamento das disfunções temporomandibulares. Estratégia de pesquisa: Foi realizado levantamento na literatura nas bases de dados PubMed, LiLACS, SciELO, Bireme, Web of Science e BBO. Os termos utilizados foram: temperatura alta, transferência de calor, articulação temporomandibular, transtornos da articulação temporomandibular, síndrome da disfunção da articulação temporomandibular e seus correspondentes em inglês e espanhol. Critérios de seleção: Foram incluídos artigos que abordaram o calor superficial no tratamento das disfunções temporomandibulares, publicados em inglês, espanhol ou português, no período de 1980 a 2013. Análise dos dados: Foram considerados: técnica de aplicação de calor superficial, duração de aplicação, área corporal estimulada, temperatura do estímulo, frequência de realização e benefícios. Resultados: inicialmente, foram encontrados 211 estudos, dos quais 13 contemplaram os critérios de seleção propostos. Os dados foram tabulados e apresentados em ordem cronológica. Conclusão: Várias técnicas de aplicação de calor superficial para tratamento das disfunções temporomandibulares foram encontradas na literatura. O calor úmido foi a modalidade mais empregada. Muitos estudos sugerem a aplicação de calor por 20 minutos, e a frequência mínima foi uma vez ao dia. A maioria dos autores recomenda a aplicação do calor nas regiões facial e cervical. O tratamento com calor apresentou benefícios como alívio da dor, redução da tensão muscular, melhora das funções da mandíbula e aumento da abertura de boca. .


Subject(s)
Humans , Hot Temperature/therapeutic use , Hyperthermia, Induced/methods , Temporomandibular Joint Disorders/therapy , Pain Measurement
7.
Bol. Centro Pesqui. Process. Aliment ; 28(1): 125-132, jan.-jun. 2010. graf
Article in Portuguese | LILACS | ID: lil-570195

ABSTRACT

O objetivo deste trabalho foi avaliar a estabilidade de soluções modelo pela determinação da temperatura de início de congelamento depois de repetidos processos de congelamento. As soluções utilizadas eram compostas por água, sacarose e Carboxi-Metil-Celulose (CMC). Foram avaliadas as concentrações de sacarose de 15 e 31,1% (m/m total da amostra) e do espessante de 0,5, 1 e 1,5% (m/m total da amostra). Buscou-se determinar a possibilidade de reutilização de soluções modelo em ensaios de congelamento. Com os resultados obtidos pode-se concluir que para a concentração de espessante de 0,5% não houve alteração da capacidade de retenção de água. A variação da concentração de sacarose não influenciou a estabilidade das soluções durante o estudo.


Subject(s)
Food Technology , Freezing , Frozen Foods , Thermal Conductivity
8.
Acta paul. enferm ; 21(3): 493-497, jul.-set. 2008.
Article in English, Portuguese | LILACS-Express | LILACS, BDENF | ID: lil-495078

ABSTRACT

Video-laparoscopy represents one of the greatest surgical advances in the recent past. Reprocessable laparoscopic instruments are complex devices that, if completely disassembled for sterilization, would cause problems for the surgical teams at the moment of their use in the surgery. The method of choice for the sterilization of this equipment is saturated steam under pressure. The goal of this review was to describe the state-of-the-art in the search for safe results in autoclaving the previously-assembled reprocessable laparoscopic instruments, since they are difficult to assemble at the moment of surgery. The PUBMED database was consulted, using controlled and free keywords, as well as their combinations, without time or language restrictions. The study investigating the exact issue of this research found contamination in both assembled (1/24) and disassembled (1/30) instruments, demonstrating equivalent risks. In view of the results and considering the lack of studies, a new experimental laboratory study is recommended, using a contamination challenge.


A vídeo-laparoscopia representa um dos maiores avanços na área da cirurgia nos últimos tempos. Os instrumentos laparoscópicos reprocessáveis são artigos complexos, que se esterilizados totalmente desmontados trazem transtornos às equipes cirúrgicas no momento da sua utilização no campo operatório. O método de escolha para a esterilização desses instrumentos é o vapor saturado sob pressão. O objetivo dessa revisão foi descrever o estado da arte em busca dos resultados da segurança na autoclavação do instrumental laparoscópico reprocessável, previamente montado, tendo em vista as dificuldades de montagem deles no momento da cirurgia. Foi consultada a base de dados PUBMED, usando vocábulos controlados, livres e a combinação deles, sem restrição de tempo e idioma. Foram localizados apenas dois artigos que permitiram conclusões favoráveis para a prática de autoclavar os instrumentos laparoscópicos previamente montados. O estudo que investigou exatamente a questão da pesquisa encontrou contaminação após a esterilização, tanto em instrumentos montados (1/24) como nos desmontados (1/30), demonstrando equivalência do risco. Frente aos resultados, e considerando a escassez de trabalhos sobre o assunto, recomenda-se um novo estudo experimental laboratorial randomizado utilizando contaminação desafio.


El video-laparoscopía representa uno de los mayores avances en el área de la cirugía en los últimos tiempos. Los instrumentos laparoscópicos reprocesables son artículos complejos, que si son esterilizados totalmente desarmados ocasionan trastornos a los equipos quirúrgicos en el momento de su utilización en el campo operatorio. El método de elección para la esterilización de esos instrumentos es el vapor saturado bajo presión. El objetivo de esta revisión fue describir el estado del arte en búsqueda de los resultados de la seguridad en el autoclavado del instrumental laparoscópico reprocesable, previamente armado, teniendo presente las dificultades de su montaje en el momento de la cirugía. Se consultó la base de datos PUBMED, usando vocablos controlados, libres y la combinación de ambos, sin restricción de tiempo e idioma. Fueron localizados apenas dos artículos que permitieron conclusiones favorables para la práctica del autoclado de los instrumentos laparoscópicos previamente armados. En el estudio que investigó exactamente el asunto de la investigación encontró contaminación después de la esterilización, tanto en instrumentos armados (1/24) como en los desarmados (1/30), demostrando equivalencia de riesgo. Frente a los resultados, y considerando la escasez de trabajos al respecto, se recomienda un nuevo estudio experimental de laboratorio randomizado utilizando contaminación desafío.

9.
Araraquara; s.n; mar. 2006. 201 p. tab, ilus, graf.
Thesis in Portuguese | BBO, LILACS | ID: biblio-864451

ABSTRACT

Com o desenvolvimento dos aparelhos LEDs para fotopolimerização de resinas compostas, intensidades maiores puderam ser atingidas sem grandes elevações de temperatura na massa da resina composta e na estrutura dental decorrentes da irradiância em comparação a aparelhos halógenos. Esse novo cenário foi o ponto de partida para o desenvolvimento desse trabalho que utilizou variadas temperaturas de cura (Tcura) (0, 25, 50, 75, 100°C) para a fotopolimerização de uma resina composta (Filtek Z250, 3M ESPE) por 40 e 60 segundos, utilizando o aparelho halógeno Gnatus Optilight Digital (halógeno) e dois LEDs que empregam uma nova tecnologia de montagem de diodos: LEC 1000 e Bright LEC (MM Optics)(LED 1 e LED2 respectivamente). A influência da temperatura de cura somada a outras variáveis estudadas foram avaliadas utilizando uma metodologia desenvolvida e aprimorada no IFSC/USP em que a penetração de um corante fluorescente no corpo da resina composta polimerizada é quantificada utilizando espectroscopia de fluorescência. De acordo com os dados finais submetidos à análise de variância, pode-se averiguar a presença de dois grupos de resultados: entre 0 e 25°C em que ambas obtiveram uma maior porcentagem de pentração do corante comparado às outras Tcura com uma variação na penetração de 69,26 +/- 8,19% até 90,99 +/- 3,38%. Na análise desse grupo o efeito tempo e temperatura foram significativos (p<0,05) sendo que a menor penetração de corante ocorreu com 60 segundos de fotoativação e esta penetração foi em média, menor com a Tcura de 25°C. Algumas interações mostraram que houve dependência entre aparelho e tempo e entre tempo e temperatura; o outro grupo refere-se as Tcura de 50, 75 e 100°C em que apesar do valor-p próximo de 0,05, o efeito temperatura foi significativo. A penetração do corante variou de 8,87 +/- 3,55 até 39,47 +/- 8,9%. Os efeitos aparelho e tempo foram altamente significativos. A penetrção com o tempo de 60 segundos foi em média menor. Exceto com o aparelho LED 1, as porcentagens de penetração do corante foram maiores com a Tcura de 100°C. A menor média foi referente a Tcura de 50°C e 60 segundos de fotoativação


With the development of the LED equipment to photopolimerization of composite resin, greater intensities could be reach without greater elevation of temperature in the mass of the composite resin and in the dental structure arisen from the irradiance in comparison to halogens equipments. This new scenario was the beginning for the development of this work that used a variety of cure temperatures (Tcure)(0, 25, 50, 75, 100°C), to a photopolymerization of a composite resin (Filtek Z250, 3M ESPE) for 40 and 60 seconds, using the halogen equipment Gnatus Optilight Digital (halogen) and two LEDs that use a new technology of assembly diodes: LEC 1000 and Bright LEC (MM Optics)(LED 1 and LED 2 respectively). The influence of cure temperature added by other variables studied were evaluated using a methodology developed and improved in the IFSC/USP in that the penetration of a fluorescent dye in the body of the photopolimerized composite resin is quantified using fluorescence spectroscopy. According to the final data submitted to an analysis of variance, it could verify the presence of two groups of results: between 0 and 25 °C both had a great percentage of the dye penetration compared to other Tcure with a variation in penetration from 69,26 +/- 8,19 % up to 90,99 +/- 3,38 %. In this analysis the effect time and temperature were highly expressive (p<0,05) and the smaller dye penetration happened to 60 seconds of photoactivation and this penetration were in media, smaller with the Tcure of 25°C. The results showed that there was interaction between the equipment and time and between time and temperature; the other group is concerning the Tcure from 50, 75 and 100°C in spite of the p-value near 0,05 the effect temperature were expressive. The penetration of the dye ranged from 8,87 +/- 3,55 up to 39,47 +/- 8,9 %. The effect equipment and time were highly expressive. The penetration with the time of 60 seconds was in average smaller. Except with the equipment LED 1, the percentages of the dye penetration were bigger with the Tcure of 100°C. The smallest average were the Tcure of 50°C and 60 seconds of photoactivation


Subject(s)
Composite Resins , Curing Lights, Dental , Diffusion , Fluorescence , Light , Polymers , Thermal Conductivity , Coloring Agents , Light-Curing of Dental Adhesives
SELECTION OF CITATIONS
SEARCH DETAIL