Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-586959

ABSTRACT

A new method is developed to detect vascular edge-line in coronary angiograms.It firstly searches the path through vessel segment of interest,then detects vascular edges along profiles perpendicular to the path.The experiments demonstrate that the method performs well in coronary angiograms with less nearby or overlapping structures and branching vessels.

SELECTION OF CITATIONS
SEARCH DETAIL