Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
J. biomed. eng ; Sheng wu yi xue gong cheng xue za zhi;(6): 99-105, 2018.
Article in Chinese | WPRIM | ID: wpr-771112

ABSTRACT

Clinical studies had demonstrated that early diagnosis of lesion could significantly reduce the risk of cancer. Magneto-acoustic-electrical tomography (MAET) is expected to become a new detection method due to its advantages of high resolution and high contrast. Based on thinking of modular design, a low-cost, digital magneto-acoustic conductivity detection system was designed and implemented in this study. The theory of MAET using chirp continuous wave excitation was introduced. The results of homogeneous phantom experiment with 0.5% NaCl clearly showed that the conductivity curve of homogeneous phantom was highly consistent with the actual physical size, which indicated that the chirp excitation theory in our proposed system was correct and feasible. Besides, the resolution obtained by 1 000 μs sweep time was better than that obtained by 500 μs and 1 500 μs, which means that sweep time is an important factor affecting the detection resolution of the conductivity. The same result was obtained in the experiments carried out on homogeneous phantoms with different concentrations of NaCl, which demonstrated the repeatability of our proposed MAET system.

2.
Yao Xue Xue Bao ; (12): 668-672, 2005.
Article in Chinese | WPRIM | ID: wpr-409750

ABSTRACT

Aim To apply stochastic resonance algorithm (SRA) to quantitative analysis of weak chromatographic signal, which was embedded in the noise. Methods Based on the theory of stochastic resonance (SR), a simple and effective SRA has been established to improve analytical detection limits of chromatographic analysis, which apply to enhance the signal to noise ratio by the optimization of the parameters and Runge-Kutta method, was established. The method was used to quantitative analysis of phenazopyridine in human plasma by HPLC/UV. Meanwhile this method is compared with HPLC/MS.Results By experimental chromatographic data sets, an excellent quantitative relationship between concentrations of phenazopyridine and their responses had been obtained. The concentration of phenazopyridine in plasma determined by HPLC/UV with SRA and HPLC/MS showed that there was no significant difference (P > 0.05) between the two methods. Conclusion The new method was feasible.

SELECTION OF CITATIONS
SEARCH DETAIL