Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 137
Filter
1.
Basic & Clinical Medicine ; (12): 131-135, 2024.
Article in Chinese | WPRIM | ID: wpr-1018584

ABSTRACT

Central serous chorioretinopathy(CSC)is a chorioretinal disease that causes idiopathic serous retinal detachment(SRD),which is associated with one or more areas of pigment epithelial detachment(PED)or defect in the retinal pigment epithelium,also with characteristic ocular structural changes.CSC was classified as pachy-choroid spectrum diseases(PSD);recent studies have found it mainly in Haller layer.Recent studies focused on the thick sclera in CSC patients,illustrated the close relation between which and choroidal circulation and put for-ward the probable pathogenesis similar to uveal effusion syndrome(UES).In addition,short axial length,hypero-pia and shallow anterior chamber are also the characteristics in CSC patients,indicating that CSC is the disease not limiting to posterior oculus,but involving the whole oculus.This review summarizes the latest research advances on optical characteristics in CSC,providing the new ideas for further research on pathogenesis of CSC.

2.
International Eye Science ; (12): 1043-1051, 2024.
Article in Chinese | WPRIM | ID: wpr-1032345

ABSTRACT

AIM:To investigate the relationship among lens parameters and their correlation with ocular anatomic characteristics in myopia patients implanted with posterior-chamber phakic implantable collamer lens(Phakic-ICL).METHODS:Retrospective study. A total of 46 myopia patients(46 eyes)who underwent Phakic-ICL implantation were collected in the Wuxi Huaxia Eye Hospital from June 2022 to June 2023. Preoperative evaluation of ocular anatomical characteristics included corneal central thickness(CCT), anterior chamber depth(ACD), axial length(AL), white-to-white(WTW), horizontal sulcus to sulcus(STSH), horizontal angle to angle(ATAH), and vertical sulcus to sulcus(STSV), vertical angle to angle(ATAV). Furthermore, lens parameters included horizontal crystalline lens rise(CLRH), vertical CLR(CLRV)and vertical lens thickness(LTV). The difference, consistency and correlation of the above parameters were analyzed.RESULTS:Except for differences between WTW and STSV, STSH and ATAV, which were not statistically significant(all P>0.05), the other horizontal and vertical ocular anatomical characteristics were statistically significant(P<0.05). CLRH and CLRV had statistically significant difference(P<0.01), while LTH and LTV were not statistically significant difference(P>0.05). Bland-Altman results revealed that the anatomical characteristics in the horizontal or vertical diameters showed poor consistency. The consistency between CLRH and CLRV was poor. There was consistency between LTH and LTV, with the 95% limits of agreement(LoA)between the differences ranging from -0.21 to 0.28 mm, and the proportion of out-of-line points off the 95% LoA was 4.35%. Pearson correlation analysis revealed that there were correlations between the anatomical characteristics of the horizontal and vertical diameters(P<0.01). Meanwhile, there was no correlation between the anteroposterior diameters(P>0.05). There were correlations between the lens parameters(P<0.05), excepted for the CLRH, LTH and LTV, which had no correlation. AL correlated with the anatomical characteristics of the horizontal and vertical diameters(P<0.05), but it had no correlation with lens parameters(P>0.05). Multiple linear regression analysis revealed that LT=0.419+0.017×age-0.548×ACD+0.371×ATAH+0.884×CLRV, CLRH=-0.443+0.809×CLRV, CLRV=-0.092-0.200×ATAH+0.560×CLRH(corrected R2=0.458, 0.482, 0.589, respectively).CONCLUSION:Horizontal and vertical diameters were not interchangeable. CLRH and CLRV were not interchangeable, while LTH and LTV were interchangeable. Partial lens parameters, WTW, STS, and ATA were correlated with ACD. Finally, age, ACD, ATAH, and CLRV influenced LT.

3.
International Eye Science ; (12): 816-820, 2024.
Article in Chinese | WPRIM | ID: wpr-1016602

ABSTRACT

AIM:To compare the differences of ocular biometric parameters of age-related cataract between Tibetan and Han ethnic groups, and to analyze the distribution characteristics of ocular biometric parameters in Tibetan cataract patients.METHODS:Retrospective cohort study. A total of 661 patients(1 030 eyes)with age-related cataract confirmed in the hospital between January 2019 and December 2020 were enrolled. The parameters of axial length, anterior chamber depth, keratometry, corneal astigmatism and astigmatic axis were measured by IOL Master 500 in 483 cases(739 eyes)of Tibetan age-related cataract patients and 178 cases(291 eyes)of Han patients.RESULTS:The axial length, anterior chamber depth and corneal astigmatism of the Tibetan patients with age-related cataract were 23.33(22.81, 23.86)mm, 3.04(2.79, 3.30)mm and 0.73(0.47, 1.07)D. The mean keratometry was 43.89±1.35 D. The results indicated that Tibetan cataract patients had shorter axial lengths and smaller keratometry compared to Han patients(all P<0.05). Age in Tibetan patients was negatively correlated with axial length and anterior chamber depth, and positively correlated with keratometry(all P<0.05). Tibetan male patients had longer axial lengths, deeper anterior chambers, and flatter corneas compared to female patients(all P<0.05).CONCLUSION:There were differences in ocular biometric parameters between age-related cataract patients of Tibetan and Han ethnicities. The distribution of ocular biometric parameters in Tibetan cataract patients varied across different age groups and gender groups.

4.
International Eye Science ; (12): 1186-1193, 2024.
Article in Chinese | WPRIM | ID: wpr-1038528

ABSTRACT

AIM: To analyze ocular biometric parameters among candidates for cataract surgery.METHODS: This cross-sectional study was conducted on 4 607 cataract patients(4 607 eyes)in Farabi Eye Hospital, Tehran, Iran from January 2017 to September 2021. Axial length(AL), keratometry(Kf, Ks and Km), and anterior chamber depth(ACD)were assessed using IOLMaster 700. All eyes were categorized into three groups based on AL: short eyes(22 mm<AL), normal eyes(22 mm≤AL≤25 mm), and long eyes(AL>25 mm)and ACD as follows: low(3.00 mm<ACD), normal(3.00 mm≤ACD ≤3.60 mm)high(ACD>3.60 mm).RESULTS: The mean age of patients was 60.3±14.1(range 8-95)years [2 243(48.69%)female and 2 364(51.31%)male]. The AL, ACD and mean keratometry ranges were 23.1 to 23.4 mm, 3.1 to 3.2 mm and 44.50 to 45.00 diopter(D), respectively. The mean amount of ACD in the long eyes group was significantly higher than the normal and short eyes group(P<0.001). The mean AL in the high ACD group was significantly higher than low and normal ACD patients(P<0.001). But the mean of Kf, Ks and Km in the low ACD and long eyes group was significantly higher than in high ACD and short AL groups(P<0.001).CONCLUSION: Those candidates with long eyes had deeper ACD with flatter cornea; while short eyes had shallower ACD with steeper cornea. Also, patients with high ACD had longer AL with flatter cornea, and patients with low ACD had lower AL with steeper cornea.

5.
Rev. cuba. oftalmol ; 36(3)sept. 2023.
Article in Spanish | LILACS, CUMED | ID: biblio-1550942

ABSTRACT

Objetivo: Determinar las modificaciones biométricas en pacientes miopes con implante de la lente fáquica ACRIOL 128. Métodos: Se realizó un estudio transversal con 31 ojos (17 pacientes) con alta miopía tratados con implante de lente fáquica ACRIOL 128, entre septiembre 2016 y febrero 2019, los cuales tenían mediciones biométricas preoperatorias con el sistema IOL Master 3.0.2 y estabilidad refractiva posoperatoria (≤ 0,5 dioptrías) después de los tres meses del implante. Se les efectuaron las mediciones posoperatorias con el propio IOL Master 3.0.2 en modo lente fáquica y con el sistema Scheimpflug Pentacam AXL para compararlas, mediante la prueba t para datos pareados, con una significación del 95 por ciento. Resultados: La edad promedio fue de 29,82 ± 5,99 años, el 82,4 por ciento del sexo femenino. El equivalente esférico preoperatorio medio fue de -12,00 ± 4,10 dioptrías. La diferencia de longitud axial y profundidad de la cámara anterior en milímetros entre el pre- y posoperatorio fue significativa con IOL Master 3.0.2 (0,13 ± 0,33 y -0,08 ± 0,17) y Pentacam AXL (0,12 ± 0,32 y -0,10 ± 0,24), respectivamente. Sin embargo, las posoperatorias entre ambos equipos no fueron significativas (p>0,05) para estas variables, pero sí para las queratometrías. Conclusiones: El implante de la lente fáquica ACRIOL 128 modifica la medición de la longitud axial y la profundidad de la cámara anterior. El IOL Master 3.0.2 y el Pentacam AXL ofrecen mediciones de longitud axial y profundidad de cámara anterior posoperatorias similares, no así para las queratometrías(AU)


Objective: To determine the biometric modifications in myopic patients with ACRIOL 128 phakic lens implantation. Methods: A cross-sectional study was performed on 31 eyes (17 patients) with high myopia treated with ACRIOL 128 phakic lens implant, between September 2016 and February 2019, which had preoperative biometric measurements with the IOL Master 3.0.2 system and postoperative refractive stability (≤ 0.5 diopters) after three months of implantation. Postoperative measurements were performed with the IOL Master 3.0.2 in phakic lens mode and with the Scheimpflug Pentacam AXL system for comparison, using the t-test for paired data, with 95% significance. Results: The average age was 29.82 ± 5.99 years, 82.4por ciento female. The mean preoperative spherical equivalent was -12.00 ± 4.10 diopters. The difference in axial length and anterior chamber depth in millimeters between pre- and postoperative was significant with IOL Master 3.0.2 (0.13 ± 0,33 and -0.08 ± 0.17) and Pentacam AXL (0.12 ± 0.32 and -0.10 ± 0.24), respectively. However, postoperative between the two teams were not significant (p > 0.05) for these variables but significant for keratometries. Conclusions: Implantation of the ACRIOL 128 phakic lens modifies the measurement of axial length and anterior chamber depth. The IOL Master 3.0.2 and Pentacam AXL provide similar postoperative axial length and anterior chamber depth measurements, but not for keratometries(AU)


Subject(s)
Humans , Biometry/methods , Phakic Intraocular Lenses
6.
Indian J Ophthalmol ; 2023 Mar; 71(3): 848-852
Article | IMSEAR | ID: sea-224887

ABSTRACT

Purpose: To assess the morphological changes in the anterior segment following laser peripheral iridotomy (LPI) in primary angle?closure disease (PACD) using Sirius Scheimpflug?Placido disk corneal topographer. Methods: This was a prospective observational study. A total of 52 eyes of 27 patients with PACD who underwent LPI were analyzed for iridocorneal angle (ICA), anterior chamber depth (ACD), anterior chamber volume (ACV), horizontal visible iris diameter (HVID), corneal volume (CV), central corneal thickness (CCT), and horizontal anterior chamber diameter (HACD) 1 week following LPI, using Sirius Scheimpflug?Placido disk corneal topographer. Data analysis was done using Statistical Package for the Social Sciences (SPSS) software version 19.0, and paired t?test was used to assess the statistical significance. Results: Laser peripheral iridotomy was performed in 43 eyes with primary angle?closure suspect (PACS), six eyes with primary angle closure (PAC), and three eyes with primary angle?closure glaucoma (PACG). The analysis of the data showed statistically significant changes in anterior segment parameters of ICA, ACD, and ACV. Post?laser increase in ICA from 34.13° ± 2.64° to 34.75° ± 2.84° (P < 0.041), mean ACD increase from 2.21 ± 0.25 to 2.35 ± 0.27 mm (P = 0.01), and mean ACV increase from 98.19 ± 12.13 to 104.15 ± 11.16 mm3 (P = 0.001) were noted. Conclusion: Significantly quantifiable short?term changes in the anterior chamber parameters of ICA, ACD, and AC volume were seen after LPI in patients with PACD on Sirius Scheimpflug?Placido disc corneal topographer.

7.
Article | IMSEAR | ID: sea-218803

ABSTRACT

Introduction: The study was conducted to evaluate IOP management by surgical modalities such as combined trabeculectomy and phacoemulsification and phacoemulsification surgery alone. Vision impairment is a major public health problem and the burden is increasing with increase in aged population. This study wasAims And Objectives: undertaken for study the IOP management by surgical modalities such as combined trabeculectomy and phacoemulsification and phacoemulsification surgery alone. A pre-designed prospective study was conducted at the OPD of upgraded Department of Ophthalmology at LLRM Medical College, Meerut. A total of 60 patients were divided in to two equal groups randomly and studied. Majority of the patients in both the groups wereObservation And Result: aged between 61 – 70 years. Females outnumbered males in this study which was statistically significant between the two groups. The mean pre- operative intra ocular pressure was 23.3 mm Hg in combined surgery group and 23.9 mm Hg in cataract surgery alone group. Mean Intra ocular pressure decreased regularly in each follow up more in combined group than the cataract surgery alone group. The mean intra ocular pressure after 1 years follow up in combined surgery group was 10.8 mm Hg and 13.4 mm Hg in the cataract surgery alone groups which was statistically significant. Mean BCVA before the operation was 3.2 in combined surgery group and 3.8 in cataract surgery before surgery. Mean BCVA declined after 1 year of follow up in combined surgery group was 1.9 and 2.7 in cataract surgery alone group which was statistically significant. The surgery success was complete in 80.0% of the combined surgery group and 60% of the cataract alone group. Criteria For Failure Of Surgeries Ÿ The IOP >23 MMHG at the end of 1 year or Ÿ The IOP not reduced by 20 % from base line at the end of 1 year Conclusion: This study was mainly undertaken to study the efficacy of combined trabeculectomy with cataract extraction and cataract only on primary angle closure glaucoma. This study had found that, the reduction of intra ocular pressure in both the groups but more prominent in combined surgery group than cataract alone surgery group.

8.
International Eye Science ; (12): 1274-1278, 2023.
Article in Chinese | WPRIM | ID: wpr-978618

ABSTRACT

AIM:To investigate the changes of anterior chamber depth(ACD)and lens suspensory ligament after phacoemulsification and intraocular lens(IOL)implantation in patients with ultra-high myopia cataract and related influencing factors.METHODS: A total of 45 patients(60 eyes)with ultra-high myopia and cataract in our hospital from October 2016 to December 2022 were selected. All patients received phacoemulsification and IOL implantation. The patients were randomly divided into implantation group and non-implantation group. Implantation group was combined with capsular tension ring(CTR)implantation, and non-implantation group did not implant CTR during operation. The changes of ACD and lens suspensory ligament length before and after operation were compared and the correlation was analyzed. To observe the differences of ACD and the length of lens suspensory ligament between the two groups before and after operation.RESULTS: The ACD of patients with ultra-high myopia complicated with cataract at 1 and 3mo after operation was higher than that before operation(all P&#x003C;0.05). The positions of 3:00, 6:00, 9:00, 12:00 and the average length of lens suspensory ligament at 1 and 3mo post-operation were shorter than those pre-operation(all P&#x003C;0.05). There was no significant difference in the positions of 3:00, 6:00, 9:00, 12:00 and average length of suspensory ligament between 1mo and 3mo after operation(all P&#x003E;0.05). The preoperative average length of lens suspensory ligament in patients with ultra-high myopia cataract was positively correlated with the ocular axis and the preoperative ACD(all P&#x003C;0.05). There was no significant difference in ACD between the implantation group and the non-implantation before and at 1 and 3mo after operation(P&#x003E;0.05). There was no significant difference in the length of lens suspensory ligament between implantation group and non-implantation group at the position of 6:00 before operation and 1mo after operation(P&#x003E;0.05), but there was difference in lens suspensory ligament between groups at 3mo after operation and the position of 6:00(P&#x003C;0.05). Furthermore, there was no significant difference at the positions of 3:00, 9:00, 12:00 and the average length of lens suspensory ligament between the implantation group and non-implantation group before and at 1 and 3mo after operation(P&#x003E;0.05).CONCLUSION: The ACD deepen and lens suspensory ligament shortened in patients with ultra-high myopia and cataract after phacoemulsification; the length of lens suspensory ligament was affected by the combined use of CTR.

9.
International Eye Science ; (12): 1718-1722, 2023.
Article in Chinese | WPRIM | ID: wpr-987897

ABSTRACT

AIM: To investigate the influencing factors of vault after the posterior chamber phakic refractive lens(PC-PRL)implantation for patients with super high myopia.METHODS: Retrospective case study. A total of 40 patients with super high myopia(77 eyes)who underwent PC-PRL implantation in the Haixiang Eye Hospital from January 2019 to January 2021 were selected. They were followed up for at least 2a, postoperative anterior segment parameters, such as the uncorrected visual acuity(UCVA), best corrected visual acuity(BCVA), central anterior chamber depth(ACD), anterior chamber volume(ACV), anterior chamber angle(ACA), lens thickness and vault were evaluated, and then the influencing factors of postoperative vault were analyzed.RESULTS: The UCVA and BCVA of the patients significantly improved after PC-PRL implantation(P&#x003C;0.001). Average safety index(postoperative BCVA/preoperative BCVA)was 1.36±0.32, and average effective index(postoperative UCVA/preoperative BCVA)was 1.23±0.31 in 2a after surgery. The vault in 2a after surgery was correlated with preoperative ACD, ACV, ACA and lens thickness, and the preoperative ACV and lens thickness had significant impact on vault in 2a after surgery.CONCLUSIONS: The PC-PRL implantation is safe and effective in super high myopia, and it can significantly improve visual acuity. Furthermore, preoperative ACV and lens thickness are important influencing factors of postoperative vault.

10.
International Eye Science ; (12): 320-324, 2023.
Article in Chinese | WPRIM | ID: wpr-960959

ABSTRACT

AIM: To investigate the changes in anterior chamber depth(ACD), axial length(AL), and corneal curvature(K)after operation in patients with high axial myopia combined with cataract, and the effect on postoperative mean refractive error(MFE)by different surgical approaches.METHODS: A total of 126 patients(126 eyes)performed cataract combined with intraocular lens(IOL)implantation were selected and divided into 3 groups according to different surgical approaches and axial length. Group A included 42 patients(42 eyes)who had cataract combined with high myopia and were performed cataract phacoemulsification combined with IOL implantation; Group B included 42 patients(42 eyes)who had cataract combined with high myopia and underwent small incision cataract extracapsular extraction combined with IOL implantation; Group C included 42 patients(42 eyes)who had cataract with normal axial length and underwent cataract phacoemulsification combined with IOL implantation. Then, the ACD, AL, K value and visual acuity of the three groups at 1d before operation and 3mo after operation were measured, and statistical analysis was performed.RESULTS: The differences in the mean values of preoperative and postoperative changes in ACD(△ACD)and AL(△AL)between groups A and B showed no statistical significance. The differences in the mean values of △ACD and △AL between groups A and C and groups B and C were both statistically significant(both P&#x0026;#x003C;0.01). △ACD and △AL in all three groups showed positive correlation(rA=0.855, rB=0.856, rC=0.639, all P&#x0026;#x003C;0.05). Furthermore, preoperative AL, △AL, △ACD and MFE in all three groups showed positive correlation(rA=0.874, 0.877, 0.858, rB=0.875, 0.879, 0.858, rC=0.428, 0.766, 0.862, all P&#x0026;#x003C;0.05). The standardized regression coefficients of groups A and B were △AL&#x0026;#x003E;△ACD(1.32 and 1.31 times), and the standardized regression coefficients of group C were △ACD&#x0026;#x003E;△AL(1.66 times).CONCLUSION: Different surgical procedures had no significant effect on the postoperative K value and MFE in patients with high axial myopia combined with cataract, of which main influencing factor is the change in the AL before and after surgery. The postoperative MFE in patients with normal AL was more due to the change of ACD.

11.
International Eye Science ; (12): 466-470, 2023.
Article in Chinese | WPRIM | ID: wpr-964250

ABSTRACT

AIM: To determine the correlation among horizontal ciliary sulcus(HCS)diameter, vertical ciliary sulcus(VCS)diameter and corneal diameter in different anterior chamber depth(ACD)levels from patients with low to moderate myopia.METHODS: Retrospective study. A total of 78 patients(129 eyes)with low to moderate myopia who had preoperative examination of implantable contact lens(ICL)implantation in Shanghai Bright Eye Hospital from April 2021 to April 2022 were included. HCS, VCS and white to white(WTW)were measured and compared. Patients were divided into shallow ACD group(2.8 mm ≤ ACD ≤3.2 mm), medium ACD group(3.2 mm < ACD ≤3.4 mm)and deep ACD group(ACD > 3.4 mm)based on the ACD obtained by Pentacam. The HCS, VCS and WTW within and among groups were compared, and the correlation of WTW, HCS and VCS among each group was analyzed by Pearson and linear regression equation.RESULTS: There was no statistical difference in WTW and HCS overall and in groups with different ACD(P>0.05), while there was difference between VCS and both HCS and WTW(P<0.01). The WTW had a correlation with both HCS and VCS in each group, while correlation between WTW and VCS was weak in the deep ACD group(r=0.470, R2=0.221, P<0.01). Furthermore, the WTW, HCS and VCS in the shallow ACD group were statistically different from those in the medium and deep ACD groups(P<0.01).CONCLUSION: The WTW was suggested predicting HCS rather than perfectly replacing HCS before patients had the ICL operation among patients with low to moderate myopia. The predictability of VCS would decline as the ACD depth increasing, predicting VCS by WTW was not recommended.

12.
Indian J Ophthalmol ; 2022 May; 70(5): 1586-1592
Article | IMSEAR | ID: sea-224288

ABSTRACT

Purpose: To evaluate the agreement between the biometric measurements used to calculate the size of the implantable collamer lenses (ICL) with different technologies: swept?source optical coherence tomography, spectral domain optical coherence tomography, and Scheimpflug tomography. Methods: This retrospective observational study included subjects undergoing refractive surgery with posterior chamber phakic IOL implantation to correct their myopia. The anterior chamber depth (ACD) and the horizontal white to white (WTW) or the angle to angle (ATA) distance were measured with the following four devices: the IOLMaster 700 biometer (Carl Zeiss Meditec, Jena, Germany), based on swept?source optical coherence tomography; the Cirrus and Visante optical coherence tomographs (Carl Zeiss Meditec) based on low?coherence interferometry; and the Pentacam rotating Scheimpflug camera (Oculus, Wetzlar, Germany). Results: In the horizontal corneal diameter measurements, there were statistically significant differences between Pentacam–IOLMaster 700 pair (P < 0.001) and Pentacam–Visante pair (P < 0.001). WTW from CIRRUS showed the lowest correlation when paired with Pentacam and IOLMaster 700 (R2 = 0.452 and 0.385 for Visante and R2 = 0.494 and 0.426 for Cirrus). Regarding the linear correlation of the ACD measurements, all pairs of devices were statistically significant and all of them showed a very good correlation index. Conclusion: There is a good agreement between the different devices under evaluation for ACD measurements. As for WTW, the values measured with the different devices showed large discrepancies with low correlation levels, especially when comparing the tomographs with the other devices under evaluation

13.
International Eye Science ; (12): 495-499, 2022.
Article in Chinese | WPRIM | ID: wpr-920440

ABSTRACT

@#AIM: To compare the safety and effectiveness of pars plane filtering(PPF)and trabeculectomy(TRA)on neovascular glaucoma(NVG). <p>METHODS: This retrospective comparison was done in 12 patients(one eye with NVG in each)who were treated with PPF surgery and 15 patients who were treated during the same period with TRA, one eye was treated in each patient. Intraocular pressure(IOP), complete surgical success rate, peripheral anterior chamber depth(PACD), postoperative anterior chamber morphology, visual acuity and complications were observed and compared between the two groups.<p>RESULTS: The IOP was significantly reduced at each time point after the surgery 1, 3d, 1wk, 1, 3mo after operation(P<0.05), and there was no significant between-group difference at any time point(P >0.05). The rate of complete success observed 3mo after operation was superior in PPF group(92% vs 53%, P<0.05). PACD was found to be deeper at 1wk after the operation in PPF group as compared with the values before the operation and was deeper than that in TRA group(P<0.05); while this comparison in TRA group showed no significant change(P>0.05). After the operation, the anterior chamber angle was open and the anterior chamber was deepened in PPF group. No significant changes in visual acuity before and after the operation within each group and between groups were observed 3mo after the surgery(P>0.05). The incidence of postoperative hemorrhage in anterior chamber was lower in PPF group(8% vs 47%, P<0.05). <p>CONCLUSION: Both PPF and TRA surgery can successfully control IOP of NVG. However, PPF surgery appeared to be superior as having a higher complete success rate. In addition, PPF surgery makes the anterior chamber deeper and wider, and result in fewer severe postoperative complications.

14.
International Eye Science ; (12): 87-90, 2022.
Article in Chinese | WPRIM | ID: wpr-906737

ABSTRACT

@#AIM: To investigate the therapeutic effect of femtosecond laser-assisted cataract surgery(FLACS)in eyes with shallow anterior chamber depth.<p>METHODS: Totally 60 eyes of 55 cataract patients with shallow anterior chamber who received cataract phacoemulsification in Tangshan eye hospital from November 2020 to February 2021 were selected, and divided into two groups according to the surgical methods on patient's subjective willingness: Patients who received FLACS were assigned to the FLACS group(28 patients, 30 eyes), and patients who received conventional Phaco(27 patients, 30 eyes)were assigned to the Phaco group. Preoperative general conditions, cumulative dissipated energy(CDE), effective phacoemulsification time(EPT), postoperative best corrected visual acuity(BCVA), uncorrected visual acuity(UCVA), endothelial cell loss rate(ECL), central macular thickness(CMT)and complications were compared and analyzed.<p>RESULTS:There was no significant difference in preoperative general data between the two groups(<i>P</i>>0.05). In both groups, UCVA at 1d, 1wk and 1mo after surgery and BCVA at 1wk and 1mo after surgery were better than those before surgery, and at 1d after surgery, UCVA in FLACS group was better than that in Phaco group, the difference was statistically significant(<i>P</i><0.05). In the FLACS group, CDE, EPT, ECL at 1wk and 1mo after surgery, and the incidence of corneal edema at 1d and 1wk after surgery were all lower than those in the Phaco group(all <i>P</i><0.05). There was no significant change in CMT in either the intragroup comparison or the intergroup comparison(<i>P</i>>0.05).<p>CONCLUSION:FLACS is safe and effective in patients with shallow anterior chamber cataract, which can significantly reduce the rate of endothelial cell loss, quickly restore vision, reduce the incidence of complications, and has no significant effect on macula.

15.
Rev. cuba. med. mil ; 50(3): e1418, 2021. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1357312

ABSTRACT

Introducción: La longitud axial ocular, la profundidad de la cámara anterior y el grosor corneal central, son tres índices biométricos oculares importantes. Estas medidas son útiles para mostrar los cambios en la población vietnamita con presbicia. Objetivos: Determinar los índices biométricos oculares, longitud axial ocular, profundidad de la cámara anterior y espesor corneal central, en población vietnamita y evaluar la correlación entre ellos y con la edad y el sexo. Métodos: Se realizó un estudio transversal en población vietnamita, con edad de 46 a 65 años. Se recogieron los datos de longitud axial ocular, profundidad de la cámara anterior y grosor corneal central. Se utilizaron la prueba t de Student y ANOVA para comparar las medias de los índices, agrupados por edad y sexo. La relación entre los índices biométricos oculares fue probada mediante la correlación de Pearson, con un nivel de significación de p < 0,05. Resultados: Se analizaron 390 ojos de 195 personas. La longitud media del eje ocular fue 23,13 ± 0,66 mm, la profundidad de la cámara anterior, 3,15 ± 0,36 mm, el grosor corneal central, 529,15 ± 30,57 µm. Los tres índices biométricos disminuyeron con la edad y fueron mayores en los hombres (p < 0,05). La longitud del eje ocular tuvo relación positiva con la profundidad de la cámara anterior (r = 0,411 y p < 0,001) y el espesor corneal central (r = 0,141 y p < 0,001). No hubo relación entre la profundidad de la cámara anterior y el grosor corneal central (r = 0,039 y p = 0,44). Conclusión: Los tres índices biométricos oculares disminuyeron con la edad y fueron mayores en los hombres. La longitud del eje ocular se relacionó con la profundidad de la cámara anterior y el grosor de la córnea central(AU)


Introduction: Ocular axial length, anterior chamber depth and central corneal thickness are three important ocular biometric indices. These measurements are useful to show changes in the Vietnamese population with presbyopia. Objectives: To determine the ocular biometric indices, ocular axial length, anterior chamber depth and central corneal thickness, in Vietnamese population and evaluate the correlation between these indices. Methods: A cross-sectional study was carried out in a Vietnamese population, aged 46 to 65 years. Data on ocular axial length, anterior chamber depth and central corneal thickness were collected. The Student's t test and ANOVA were used to compare the means of the indices, grouped by age and sex. The relationship between the ocular biometric indices was tested using Pearson's correlation, with a significance level of p <0.05. Results: 390 eyes of 195 people were analyzed. The mean length of the ocular axis was 23.13 ± 0.66 mm, the depth of the anterior chamber, 3.15 ± 0.36 mm, and the central corneal thickness, 529.15 ± 30.57 µm. The three biometric indices decreased with age and were higher in men (p <0.05). The length of the ocular axis had a positive relationship with the depth of the anterior chamber (r = 0.411 and p <0.001) and the central corneal thickness (r = 0.141 and p <0.001). There was no relationship between anterior chamber depth and central corneal thickness (r = 0.039 and p = 0.44). Conclusion: Three ocular biometric indices decreased with age and were higher in men. The length of the ocular axis was related to the depth of the anterior chamber and the thickness of the central cornea(AU)


Subject(s)
Humans , Middle Aged , Axial Length, Eye/physiology , Anterior Chamber/physiology , Cross-Sectional Studies , Biometry/methods
16.
International Eye Science ; (12): 702-706, 2021.
Article in Chinese | WPRIM | ID: wpr-873874

ABSTRACT

@#AIM: To compare the measurement results of anterior chamber depth(ACD)by Pentacam, IOL Master and Contact Ultrasonic A-scan, and analyze the difference, correlation, consistency and influencing factors of the three measurement methods.<p>METHODS: In this study of 307 eyes of 250 cataract patients with preoperative, ACD estimation was done by Pentacam, IOL Master and Contact Ultrasonic A-scan. The independent sample <i>t</i>-test, Analysis of Variance(ANOVA), Pearson's correlation test and multiple linear regressions were used to analyze the results.<p>RESULTS: The mean of ACD measured by Pentacam(ACDp), IOL Master(ACDi)and A-scan(ACDa)were 2.42±0.45mm, 2.96±0.43mm, 2.58±0.36mm, the difference was statistically significant(<i>F</i>=136.694, <i>P</i><0.05). The three methods were sequentially compared in pairs, and the differences within the groups were statistically significant(<i>P</i><0.05). Pearson's correlation test was performed on the three methods in pairs, and there was a linear positive correlation within each group. When the ACDp and the central corneal thickness(CCT)were added, the sum(ACDp2)was no statistically significant compared with the ACDi(<i>P</i>=0.93). When the ACDp was less than 1.85mm(ACDi was about 2.40mm), the ACDa increases significantly and the fluctuation increases. Among the many possible influencing factors, axial length, lens thickness and age have the highest relative importance for ACD measurement.ACD was positively correlated with axial length(<i>r</i>Pentacam=0.602, <i>r</i>IOL Master=0.603, <i>r</i>A-scan=0.483), and negatively correlated with the lens thickness(<i>r</i>Pentacam= -0.382, <i>r</i>IOL Master= -0.350, <i>r</i>A-scan= -0.582), negatively correlated with age(<i>r</i>Pentacam= -0.328, <i>r</i>IOL Master= -0.414, <i>r</i>A-scan= -0.265). Three factors were included in the multiple linear regression model, and the age factor of Contact Ultrasonic A-scan was eliminated due to the low influence weight.<p>CONCLUSION: ACDp2 and ACDi may be closer to the true value of the anterior chamber depth. The Contact Ultrasonic A-scan may increase the measurement error when measuring shallow anterior chamber. Axial length, lens thickness and age have the greatest influence on ACD measurement, which are the influencing factors of Pentacam and IOL Master, but age is not the influencing factor of Contact Ultrasonic A-scan.

17.
International Eye Science ; (12): 738-741, 2021.
Article in Chinese | WPRIM | ID: wpr-873883

ABSTRACT

@#AIM: To investigate the correlation of myopia severity(SE)with axial length(AL), intraocular pressure(IOP), central corneal thickness(CCT), anterior chamber depth(ACD), and mean keratometry(Km)in young myopia patients.<p>METHODS: In the retrospective study, we selected myopic patients who were diagnosed in Lanzhou Huaxia Eye Hospital from Mar. 2017 to Jul. 2019. They were divided into four myopia groups, A(mild), B(moderate), C(high), and D(hyper)based on the SE. We then measured and analyzed the correlation of the degree of myopia with AL, IOP, CCT, ACD, and Km. Differences between groups were analyzed by one-way analysis of variance. Relationships between the relevant factors were analyzed by Pearson correlation analysis.<p>RESULTS: The SE were(-2.38±0.49)D,(-4.60±0.82)D,(-7.40±1.08)D and(-11.58±1.23)D in the mild, moderate, high and hyper myopia groups respectively. The AL were(24.55±0.72)mm,(25.68±0.77)mm,(26.75±0.64)mm and(28.00±0.56)mm in the respective myopia groups. The IOP were(14.68±3.18)mmHg,(14.78±2.81)mmHg,(15.19±2.66)mmHg,(15.70±2.68)mmHg in the respective myopia groups. The ACD were(3.41±0.24)mm,(3.34±0.25)mm,(3.32±0.25)mm and(3.24±0.27)mm in the respective myopia groups. The Km were(42.96±1.22)D,(43.02±1.43)D,(43.29±1.47)D and(43.56±1.47)D in the respective myopia groups. There were no significant differences for CCT among the different groups. SE was significantly positive correlated to AL(<i>r</i>=0.851, <i>P</i><0.001), IOP(<i>r</i>=0.104, <i>P</i><0.001), CCT(<i>r</i>=0.066, <i>P</i><0.001)and Km(<i>r</i>=0.157, <i>P</i><0.001); SE was negative correlated to ACD(<i>r</i>=-0.129, <i>P</i><0.001).<p>CONCLUSION: In our study, there is a positive correlation between the progression of myopia and the increase in AL, IOP, CCT, and Km. There is a negative correlation between myopia and ACD.

18.
International Eye Science ; (12): 1786-1791, 2021.
Article in Chinese | WPRIM | ID: wpr-886725

ABSTRACT

@#AIM: To compare the differences and agreement in axial length(AL), anterior chamber depth(ACD)flat axial corneal curvature(K1)and steep axial corneal curvature(K2)measured by SW-9000 and IOL Master 500.<p>METHODS: Totally 258 eyes of 129 patients with ametropia were measured with SW-9000 and IOL Master 500. Among them, 159 eyes were low to moderate myopia(-0.75D≤ spherical equivalent <-6D)and 99 eyes were high myopia(spherical equivalent ≥-6D). Comparison between two devices were performed for AL, ACD, K1, and K2. The difference between two instruments were evaluated with a paired samples <i>t</i>-test. The correlation between the measurements was evaluated using Pearson correlation coefficients. The agreement between the devices was evaluated with Bland-Altman plots. <p>RESULTS: There was significant difference between SW-9000 and IOL Master 500 in measuring AL and ACD(all <i>P</i><0.01), but there was no significant difference between K1 and K2 in patients with low to moderate myopia. There was no significant difference in AL, ACD and K1 between SW-9000 and IOL Master 500(all <i>P</i>>0.05), but there was significant difference in K2(<i>P</i><0.05)in patients with high myopia. Pearson correlation analysis showed that AL, ACD, K1 and K2 of patients with low to moderate and high myopia were highly correlated(all <i>P</i><0.01). Bland-Altman consistency analysis showed that the two methods had good consistency in measuring AL in patients with low to moderate and high myopia, but poor consistency in measuring ACD, K1 and K2.<p>CONCLUSION: SW-9000 and IOL Master 500 have good consistency in measuring the AL of people with ametropia. The measurement of ACD and corneal curvature has poor consistency, and should be carefully selected in combination with clinical practice.

19.
International Eye Science ; (12): 1315-1318, 2021.
Article in English | WPRIM | ID: wpr-882084

ABSTRACT

@#AIM: To observe the safety and efficacy of the 25G anterior vitrectomy surgical technique <i>via</i> scleral flap in phacoemulsification combined with trabeculectomy for glaucoma and cataract with extremely shallow anterior chamber.<p>METHODS: This retrospective case review consisted of 18 eyes of 18 patients(8 males and 10 females), of those, 11 eyes had acute angle-closure glaucoma with angle-closure greater than 180 degree, and 7 eyes had lens subluxation combined with glaucoma. All 18 patients underwent phacoemulsification, intraocular lens(IOL)implantation, trabeculectomy, and anterior vitrectomy <i>via</i> the scleral flap in cases where conservative management techniques cannot control intraocular pressure(IOP). The main outcomes were best corrected visual acuity(BCVA), anterior chamber depth(ACD), IOP, slit-lamp microscopic examination, number of medications, fundus examination, and complications.<p>RESULTS: The average axial length(AL)was 21.5±0.6 mm. Mean age was 62.3±7.9 years. Mean ACD increased significantly from 0.78±0.43 mm to 2.89±0.41 mm 1wk after surgery(<i>P</i><0.001). Mean IOP decreased significantly from 43.28±9.38 mmHg to 16.72±6.28 mmHg(<i>P</i><0.001). No serious complications, such as endophthalmitis, retinal detachment, suprachoroidal hemorrhage, corneal decompensation, and malignant glaucoma were observed.<p>CONCLUSION: 25G anterior vitrectomy <i>via</i> scleral flap is a safe and effective technique for glaucoma and cataract with extremely shallow anterior chamber.

20.
International Eye Science ; (12): 1315-1318, 2021.
Article in English | WPRIM | ID: wpr-882085

ABSTRACT

@#AIM: To observe the safety and efficacy of the 25G anterior vitrectomy surgical technique <i>via</i> scleral flap in phacoemulsification combined with trabeculectomy for glaucoma and cataract with extremely shallow anterior chamber.<p>METHODS: This retrospective case review consisted of 18 eyes of 18 patients(8 males and 10 females), of those, 11 eyes had acute angle-closure glaucoma with angle-closure greater than 180 degree, and 7 eyes had lens subluxation combined with glaucoma. All 18 patients underwent phacoemulsification, intraocular lens(IOL)implantation, trabeculectomy, and anterior vitrectomy <i>via</i> the scleral flap in cases where conservative management techniques cannot control intraocular pressure(IOP). The main outcomes were best corrected visual acuity(BCVA), anterior chamber depth(ACD), IOP, slit-lamp microscopic examination, number of medications, fundus examination, and complications.<p>RESULTS: The average axial length(AL)was 21.5±0.6 mm. Mean age was 62.3±7.9 years. Mean ACD increased significantly from 0.78±0.43 mm to 2.89±0.41 mm 1wk after surgery(<i>P</i><0.001). Mean IOP decreased significantly from 43.28±9.38 mmHg to 16.72±6.28 mmHg(<i>P</i><0.001). No serious complications, such as endophthalmitis, retinal detachment, suprachoroidal hemorrhage, corneal decompensation, and malignant glaucoma were observed.<p>CONCLUSION: 25G anterior vitrectomy <i>via</i> scleral flap is a safe and effective technique for glaucoma and cataract with extremely shallow anterior chamber.

SELECTION OF CITATIONS
SEARCH DETAIL