Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.966
Filter
1.
Braz. j. biol ; 84: e254010, 2024. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1345561

ABSTRACT

Abstract The impact of fish oil concentration on the oxidative stability of microcapsules through the spray drying process using chitosan and maltodextrin as wall material was studied. Emulsions were prepared with different Tuna fish oil (TFO) content (TFO-10%, TFO20%, TF030% TF0-40%) while wall material concentration was kept constant. Microencapsulated powder resulting from emulsion prepared with high fish oil load have high moisture content, wettability, total oil and low encapsulation efficiency, hygroscopicity and bulk tapped density. Oxidative stability was evaluated periodically by placing microcapsules at room temperature. Microcapsules prepared with TFO-10% presented high oxidative stability in terms of peroxide value (2.94±0.04) and anisidine value (1.54±0.02) after 30 days of storage. It was concluded that optimal amounts of fish oil for microencapsulation are 10% and 20% using chitosan and maltodextrin that extended its shelf life during study period.


Resumo Foi estudado o impacto da concentração de óleo de peixe na estabilidade oxidativa de microcápsulas por meio do processo de secagem por atomização, utilizando quitosana e maltodextrina como material de parede. As emulsões foram preparadas com diferentes teores de óleo de atum (TFO) (TFO-10%, TFO20%, TF030% TF0-40%), enquanto a concentração de material de parede foi mantida constante. O pó microencapsulado resultante da emulsão preparada com alta carga de óleo de peixe tem alto teor de umidade, molhabilidade e óleo total e baixa eficiência de encapsulação, higroscopicidade e densidade extraída a granel. A estabilidade oxidativa foi avaliada periodicamente colocando microcápsulas à temperatura ambiente. As microcápsulas preparadas com TFO-10% apresentaram alta estabilidade oxidativa em termos de valor de peróxido (2,94 ± 0,04) e valor de anisidina (1,54 ± 0,02) após 30 dias de armazenamento. Concluiu-se que as quantidades ideais de óleo de peixe para microencapsulação são de 10% e 20% usando quitosana e maltodextrina que prolongaram sua vida útil durante o período de estudo.


Subject(s)
Animals , Fish Oils , Chitosan , Powders , Tuna , Oxidative Stress
2.
Braz. j. biol ; 84: e255235, 2024. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1355897

ABSTRACT

Abstract In soybean breeding program, continuous selection pressure on traits response to yield created a genetic bottleneck for improvements of soybean through hybridization breeding technique. Therefore an initiative was taken to developed high yielding soybean variety applying mutation breeding techniques at Plant Breeding Division, Bangladesh Institute of Nuclear Agriculture (BINA), Bangladesh. Locally available popular cultivar BARI Soybean-5 was used as a parent material and subjected to five different doses of Gamma ray using Co60. In respect to seed yield and yield attributing characters, twelve true breed mutants were selected from M4 generation. High values of heritability and genetic advance with high genotypic coefficient of variance (GCV) for plant height, branch number and pod number were considered as favorable attributes for soybean improvement that ensure expected yield. The mutant SBM-18 obtained from 250Gy provided stable yield performance at diversified environments. It provided maximum seed yield of 3056 kg ha-1 with highest number of pods plant-1 (56). The National Seed Board of Bangladesh (NSB) eventually approved SBM-18 and registered it as a new soybean variety named 'Binasoybean-5' for large-scale planting because of its superior stability in various agro-ecological zones and consistent yield performance.


Resumo No programa de melhoramento da soja, a pressão pela seleção contínua para a resposta das características de rendimento criou um gargalo genético para melhorias da soja por meio da técnica de melhoramento por hibridação. Portanto, foi desenvolvida uma variedade de soja de alto rendimento, aplicando técnicas de reprodução por mutação, na Divisão de Melhoramento de Plantas, no Instituto de Agricultura Nuclear de Bangladesh (BINA), em Bangladesh. A cultivar popular BARI Soybean-5, disponível localmente, foi usada como material original e submetida a cinco doses diferentes de raios gama usando Co60. Em relação ao rendimento de sementes e às características de atribuição de rendimento, 12 mutantes genuínos foram selecionados a partir da geração M4. Altos valores de herdabilidade e avanço genético com alto coeficiente de variância genotípico (GCV) para altura da planta, número de ramos e número de vagens foram considerados atributos favoráveis ​​ao melhoramento da soja, garantindo, assim, a produtividade esperada. O mutante SBM-18, obtido a partir de 250Gy, proporcionou desempenho de rendimento estável em ambientes diversificados e produtividade máxima de sementes de 3.056 kg ha-1 com o maior número de vagens planta-1 (56). O Conselho Nacional de Sementes de Bangladesh (NSB) finalmente aprovou o SBM-18 e o registrou como uma nova variedade de soja, chamada 'Binasoybean-5', para plantio em larga escala por causa de sua estabilidade superior em várias zonas agroecológicas e desempenho de rendimento consistente.


Subject(s)
Soybeans/growth & development , Soybeans/genetics , Phenotype , Bangladesh , Plant Breeding , Genotype , Mutation
3.
Rev. flum. odontol ; 1(60): 112-126, jan.-abr. 2023. tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1411346

ABSTRACT

A descoloração ou perda de translucidez dos materiais cerâmicos usados em odontologia ainda hoje é um problema, especialmente pelo comprometimento estético. Com o objetivo de comparar a estabilidade de cor, blocos de dissilicato de lítio (IPS e.max CAD HT) e de silicato de lítio reforçado com zircônia (Vita Suprinity HT) fresados no desenho de um disco com dimensões de 1,5 × 7 × 12 mm3 (n = 120) foram preparados usando 3 procedimentos de acabamento de superfície: glaze, polimento mecânico e coloração externa e glaze. Em seguida, cada grupo foi dividido em 2 subgrupos de armazenamento, chá preto e café (n = 10/grupo). As mensurações de cor foram medidas com espectrofotômetro (VITA Easyshade) no estágio inicial e após 1 semana, 2 semanas, 1 mês, 2 meses de armazenamento. As alterações de cor (ΔE) foram calculadas e analisadas estatisticamente usando ANOVA (α < 0,05). Observamos que, para ambos os materiais cerâmicos, o procedimento de glaze apresentou valores de mudança de cor estatisticamente menores do que os outros grupos (p < 0,05) após o armazenamento em ambas as bebidas. Os grupos de dissilicato de lítio apresentaram valores de alteração de cor estatisticamente menores em relação aos grupos de silicato de lítio reforçados com zircônia. Conclui-se que, o glaze sozinho levou a uma maior estabilidade de cor em relação ao polimento mecânico e coloração externa o dissilicato de lítio apresentou maior estabilidade de cor em comparação com o silicato de lítio reforçada com zircônia.


The discoloration or loss of translucency of ceramic materials used in dentistry is still a problem today, especially due to aesthetic compromise. In order to compare color stability, lithium disilicate (IPS e.max CAD HT) and zirconia-reinforced lithium silicate (Vita Suprinity HT) blocks were milled into a disc design with dimensions of 1.5 × 7 × 12 mm3 (n = 120). The specimens were prepared using 3 surface finishing procedures: glaze, mechanical polishing and external staining and glaze. Then, each group was divided into 2 storage subgroups, black tea and coffee (n = 10/group). Color measurements were measured with a spectrophotometer (VITA Easyshade) at the initial stage and after 1 week, 2 weeks, 1 month, 2 months of storage. Color changes (ΔE) were calculated and statistically analyzed using ANOVA (α < 0.05). We observed that, for both ceramic materials, the glaze procedure presented statistically lower color change values ​​than the other groups (p < 0.05) after storage in both beverages. The lithium disilicate groups showed statistically lower color change values ​​than the zirconia-reinforced lithium silicate groups. It is concluded that, glaze alone led to greater color stability compared to mechanical polishing and external staining, lithium disilicate showed greater color stability compared to zirconia-reinforced lithium silicate.

4.
Rev. bras. med. esporte ; 29: e2022_0327, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1407587

ABSTRACT

ABSTRACT Introduction: Physical confrontation in soccer games presents greater demands on athletes' physical fitness. A soccer player's speed, strength, flexibility, coordination, endurance, and explosiveness can affect the body's fighting capacity. Objective: This study analyzes the relationship between strength training in soccer players' abdominal core and physical fitness. Methods: The effect of abdominal core stability strength training on performance improvement in volunteer soccer players selected as research subjects was verified by random division into two groups (experimental and control groups). Both groups performed daily training. The experimental group added special abdominal core training. Mathematical-statistical algorithms were used to statistically analyze the physical indicators of the two groups of volunteers. Results: The indices of physical fitness and body explosiveness of the two groups of athletes were significantly improved (P<0.05). After systematic training, the competition performance of the experimental group and the physiological and biochemical indicators were better than the control group (P<0.05). Conclusion: After abdominal core training, soccer players' physical fitness and explosive power indexes were improved. Research shows that strength training can help improve abdominal core performance in soccer players. It is recommended that coaches implement abdominal core strength training in the daily training of athletes. Level of evidence II; Therapeutic studies - investigation of treatment outcomes.


RESUMO Introdução: O confronto físico nos jogos de futebol apresenta maiores exigências quanto à aptidão física dos atletas. A velocidade, força, flexibilidade, coordenação, resistência e explosividade de um jogador de futebol podem afetar a capacidade de combate corporal. Objetivo: Este estudo visa analisar a relação entre o treinamento de força no core abdominal dos jogadores de futebol e sua aptidão física. Métodos: O efeito do treinamento de força da estabilidade do core abdominal sobre a melhoria do desempenho nos jogadores de futebol voluntários selecionados como objetos de pesquisa foi verificado por divisão aleatória em dois grupos (grupos experimentais e grupos de controle). Ambos os grupos realizavam treinamentos diários. O grupo experimental acrescentou treinamento especial de core abdominal. Foram utilizados algoritmos matemáticos-estatísticos para analisar os indicadores físicos dos dois grupos de voluntários de forma estatística. Resultados: Os índices de aptidão física e explosividade corporal dos dois grupos de atletas foram significativamente melhorados (P<0,05). Após o treinamento sistemático, o desempenho de competição do grupo experimental e os indicadores fisiológicos e bioquímicos foram melhores que os do grupo de controle (P<0,05). Conclusão: Após o treinamento do core abdominal, a aptidão física dos jogadores de futebol e os índices de potência explosiva foram melhorados. Pesquisas mostram que o treinamento da força pode ajudar a melhorar o desempenho do core abdominal nos jogadores de futebol. Recomenda-se aos treinadores a implementação do treino de força no core abdominal ao treinamento diário dos atletas. Nível de evidência II; Estudos terapêuticos - investigação dos resultados do tratamento.


RESUMEN Introducción: El enfrentamiento físico en los partidos de fútbol presenta mayores exigencias a la aptitud física de los atletas. La velocidad, la fuerza, la flexibilidad, la coordinación, la resistencia y la explosividad de un jugador de fútbol pueden afectar a la capacidad de combate del cuerpo. Objetivo: Este estudio tiene como objetivo analizar la relación entre el entrenamiento de la fuerza en el core de los jugadores de fútbol y su condición física. Métodos: El efecto del entrenamiento de la fuerza de la estabilidad del core abdominal sobre la mejora del rendimiento en jugadores de fútbol voluntarios seleccionados como sujetos de la investigación se verificó mediante la división aleatoria en dos grupos (grupo experimental y grupo de control). Ambos grupos realizaron un entrenamiento diario. El grupo experimental añadió un entrenamiento especial del core abdominal. Se utilizaron algoritmos matemático-estadísticos para analizar de forma estadística los indicadores físicos de los dos grupos de voluntarios. Resultados: Los índices de aptitud física y explosividad corporal de los dos grupos de atletas mejoraron significativamente (P<0,05). Tras el entrenamiento sistemático, el rendimiento en competición del grupo experimental y los indicadores fisiológicos y bioquímicos fueron mejores que los del grupo de control (P<0,05). Conclusión: Tras el entrenamiento del core abdominal, mejoraron la condición física y los índices de potencia explosiva de los futbolistas. Las investigaciones demuestran que el entrenamiento de fuerza puede ayudar a mejorar el rendimiento del core abdominal en los jugadores de fútbol. Se recomienda que los entrenadores implementen el entrenamiento de fuerza en el core abdominal al entrenamiento diario de los atletas. Nivel de evidencia II; Estudios terapéuticos - investigación de los resultados del tratamiento.

5.
Rev. bras. med. esporte ; 29: e2022_0304, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1407635

ABSTRACT

ABSTRACT Introduction: Physical conditioning is an essential component of sports skills. The main routine training methods for skill enhancement in martial arts players should be based on traditional movements. Core strength training has also been shown to be valid for the physical conditioning of martial arts players. Objective: This paper studies the qualitative changes in the balance of martial arts athletes caused by the insertion of core strength training. Methods: This paper selects 24 martial arts players by sampling and randomly divides them into control and experimental groups. The biomarkers of the volunteers were stored and processed under statistical methods to organize and display the data. Results: The experimental and control groups showed high statistical significance in each index after testing (P<0.05). The results show that the methods used in the experimental and control groups can effectively improve their performance in core and key explosive movements during exercise. There were very significant changes in the extensor muscle peak in both groups. The experimental group showed more significant improvement than the standard group (P<0.05). The experimental group's flexor peaks showed a more significant difference than the control group. In contrast, the experimental group showed a more remarkable improvement than the standard group (P<0.05). Conclusion: Core resistance exercise can effectively promote a center of gravity balance in martial arts athletes. Level of evidence II; Therapeutic studies - investigation of treatment outcomes.


RESUMO Introdução: O condicionamento físico é um componente essencial das habilidades esportivas. Os principais métodos de treino de rotina para aumento da habilidade dos jogadores de artes marciais devem ser baseados em movimentos tradicionais. O treinamento de resistência do core também já se mostrou válido sobre o condicionamento físico dos jogadores de artes marciais. Objetivo: Este artigo estuda as alterações qualitativas sobre o equilíbrio dos atletas de artes marciais provocadas pela inserção do treino de resistência do core. Métodos: Este artigo seleciona 24 jogadores de artes marciais por amostragem e os divide aleatoriamente em grupos controle e experimental. Os biomarcadores dos voluntários foram armazenados e processados sob métodos estatísticos para organizar e exibir os dados. Resultados: Os grupos experimentais e de controle apresentaram alta significância estatística em cada índice após o teste (P<0,05). Os resultados mostram que os métodos utilizados nos grupos experimentais e de controle podem melhorar efetivamente seu desempenho no core e nos principais movimentos explosivos durante o exercício. Houveram mudanças muito significativas no pico dos músculos extensores em ambos os grupos. O grupo experimental apresentou melhora mais significativa do que o grupo padrão (P<0,05). Em comparação com o grupo controle, os picos de flexores do grupo experimental apresentaram uma diferença mais significativa. Em contrapartida, o grupo experimental apresentou uma melhora mais notável do que o grupo padrão (P<0,05). Conclusão: O exercício de resistência do core pode efetivamente promover a equilíbrio do centro de gravidade nos atletas de artes marciais. Nível de evidência II; Estudos terapêuticos - investigação dos resultados do tratamento.


RESUMEN Introducción: El acondicionamiento físico es un componente esencial de las habilidades deportivas. Los principales métodos de entrenamiento rutinario para aumentar la capacidad de los jugadores de artes marciales deben basarse en los movimientos tradicionales. El entrenamiento de la fuerza del core también ha demostrado su validez en el acondicionamiento físico de los jugadores de artes marciales. Objetivo: Este trabajo estudia los cambios cualitativos en el equilibrio de los atletas de artes marciales causados por la inserción del entrenamiento de resistencia del core. Métodos: Este artículo selecciona 24 jugadores de artes marciales por muestreo y los divide aleatoriamente en grupos de control y experimental. Los biomarcadores de los voluntarios se almacenaron y procesaron con métodos estadísticos para organizar y mostrar los datos. Resultados: Los grupos experimental y de control mostraron una alta significación estadística en cada índice tras la prueba (P<0,05). Los resultados muestran que los métodos utilizados en los grupos experimental y de control pueden mejorar eficazmente su rendimiento en los movimientos explosivos centrales y principales durante el ejercicio. Hubo cambios muy significativos en el pico muscular extensor en ambos grupos. El grupo experimental mostró una mejora más significativa que el grupo estándar (P<0,05). En comparación con el grupo de control, los picos flexores del grupo experimental mostraron una diferencia más significativa. En cambio, el grupo experimental mostró una mejora más notable que el grupo estándar (P<0,05). Conclusión: El ejercicio de resistencia del core puede promover eficazmente el equilibrio del centro de gravedad en los atletas de artes marciales. Nivel de evidencia II; Estudios terapéuticos - investigación de los resultados del tratamiento.

6.
Rev. bras. med. esporte ; 29: e2021_0013, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1387958

ABSTRACT

ABSTRACT Introduction Strong core stability and strength enable the trunk to transfer the maximum amount of torque to the terminal segments, which is conducive to improving athletic performance. Because sling training is a new core exercise method, its effect on trunk endurance relative to basketball performance has rarely been studied. Objective To investigate whether a core exercise program in a specific sports group can improve core and sports-specific performance. Methods A total of 40 college students majoring in basketball were randomly assigned to training and control groups. A standardized set of core endurance and basketball-specific performance tests were used to determine and assess the effects of sling training on trunk strength, endurance, and control. Results Flexor, extensor, and right and left lateral trunk flexor muscles endurance were significantly greater in the training group than in the control group, and the time to complete the layup obstacle course was shorter than in the control group at the end of the training program, p<0.01. No differences between the two groups were found in the penalty shot, the fixed position shot, or the vertical jump and reach at the end of the training program. Conclusions Sling exercises can improve the core endurance and strength of basketball players and increase the speed of lay-ups over obstructions. Level of evidence I; Randomized clinical trial.


RESUMEN Introducción La sólida estabilidad y fuerza del core permiten que el tronco transfiera el torque máximo a los segmentos terminales, lo que conduce a mejorar el rendimiento deportivo. Como método novedoso de ejercicio para el core, se ha estudiado poco el efecto del entrenamiento con ejercicios con sling sobre la resistencia del tronco en relación con el rendimiento en el baloncesto. Objetivo Investigar si un programa de ejercicios para el core en un grupo deportivo específico puede mejorar el rendimiento del core y específico del deporte. Métodos Un total de 40 estudiantes universitarios con especialización en baloncesto fueron asignados aleatoriamente a grupos de entrenamiento y de control. Se utilizó una serie estandarizada de pruebas de resistencia del core y rendimiento específico del baloncesto para determinar y evaluar los efectos de los ejercicios con sling en la fuerza, la resistencia y el control del tronco. Resultados La resistencia de los músculos flexores, extensores y flexores laterales derecho e izquierdo del tronco fue significativamente mayor en el grupo de entrenamiento en comparación con el grupo de control, y el tiempo para completar la prueba de tiro con obstáculos fue menor que el del grupo de control al final del programa de entrenamiento, p<0,01. No hubo diferencias entre los dos grupos en lo que respecta a: tiro libre, lanzamiento en posición fija y salto vertical y alcance al final del programa de entrenamiento. Conclusiones Los ejercicios con sling pueden mejorar la resistencia y la fuerza del core en jugadores de baloncesto y aumentar la velocidad de los tiros con dribling. Nivel de evidencia I; Ensayo clínico aleatorizado.


RESUMO Introdução A sólida estabilidade e a força do core permitem que o tronco transfira o torque máximo para os segmentos terminais, o que é propício para melhorar o desempenho atlético. Como um novo método de exercício para o core, o efeito do treinamento com sling na resistência do tronco com relação ao desempenho no basquete tem sido pouco estudado. Objetivo Investigar se um programa de exercícios para o core em um grupo esportivo específico pode melhorar o desempenho do core e específico do esporte. Métodos Um total de 40 estudantes universitários formados em basquete foram aleatoriamente designados para grupos de treinamento e controle. Uma série padronizada de testes de resistência do core e desempenho específico do basquete foi usada para determinar e avaliar os efeitos dos exercícios com sling na força, resistência e controle do tronco. Resultados A resistência dos músculos flexores, extensores e flexores laterais direito e esquerdo do tronco foi significativamente maior no grupo treinamento em comparação ao grupo controle e o tempo para concluir o teste de bandeja com obstáculos foi menor que o do grupo controle no final do programa de treinamento, p < 0,01. Não houve diferenças entre os dois grupos quanto ao lance livre, arremesso em posição fixa e salto vertical e alcance no final do programa de treinamento. Conclusões Os exercícios com sling podem melhorar a resistência e a força do core em jogadores de basquete e aumentar a velocidade das bandejas com drible. Nível de evidência I; Estudo clínico randomizado.

7.
Afr. j. infect. dis. (Online) ; 17(1): 10-26, 2023. figures, tables
Article in English | AIM | ID: biblio-1411563

ABSTRACT

Background: Ebola Virus causes disease both in human and non-human primatesespecially in developing countries. In 2014 during its outbreak, it led to majority of deaths especially in some impoverished area of West Africa and its effect is still witnessed up till date. Materials and Methods:We studied the spread of Ebola virus and obtained a system of equations comprising of eighteen equations which completely described the transmission of Ebola Virus ina population where control measures were incorporated and a major source of contacting the disease which is the traditional washing of dead bodies was also incorporated. We investigated the local stability of the disease-free equilibrium using the Jacobian Matrix approach and the disease-endemic stability using the center manifold theorem. We also investigated the global stability of the equilibrium points using the LaSalle's Invariant principle.Results: The result showed that the disease-free and endemic equilibrium where both local and globally stable and that the system exhibits a forward bifurcation.Conclusions: Numerical simulations were carried out and our graphs show that vaccine and condom use is best for susceptible population, quarantine is best for exposed population, isolation is best for infectious population and proper burial of the diseased dead is the best to avoid further disease spread in the population and have quicker and better recovery.


Subject(s)
Vaccines , Disease Transmission, Infectious , Hemorrhagic Fever, Ebola , Models, Theoretical , Quarantine
8.
MHSalud ; 19(2)dic. 2022.
Article in Spanish | LILACS-Express | LILACS, SaludCR | ID: biblio-1405527

ABSTRACT

Resumen El estudio tiene como propósito analizar la fiabilidad de la prueba de 8 lanzamientos de 3 diferentes variantes de lanzamientos de balonmano en estudiantado universitario. 33 varones, 20 ±1,9 años; peso 72,39±8,9 kg; altura 176,75 ±6,07 cm; IMC 23,14±2,3. Los sujetos participantes fueron evaluados en 2 sesiones separadas entre sí por un lapso de una semana. Ejecutaron lanzamientos hasta quedar registrados 8 mediciones en cada una de las pruebas, lanzamientos inespecíficos, en apoyo y en carrera con 3 pasos, se registró la velocidad de lanzamiento con un radar posterior a la portería. La fiabilidad del promedio de las puntuaciones del test de 8 medidas entre la primera sesión y la segunda con una prueba test-retest, se obtuvieron los siguientes resultados: en el lanzamiento inespecífico se obtuvo un ICC= (0,86) entre el 95% de confianza, un de CV= (7,43%) y un ES= (0,08). Para el lanzamiento con apoyo se obtuvo un ICC= (0,94) al 95 % de confianza, un de CV= (4,71 %) y un ES= (-0,09). Para el lanzamiento con carrera se obtuvo un ICC= (0,96) al 95 % de confianza, un de CV= (4,00 %) y un ES= (0,05). Este estudio ha demostrado que la prueba de 8 lanzamientos y las 3 variantes es una medida de rendimiento confiable y estable para estudiantes de nivel universitario sin experiencia en el balonmano, en relación con las variables del lanzamiento, las 3 fueron fiables, solo la variable inespecífica fue menor en comparación al lanzamiento con apoyo y con carrera.


Abstract This study aims to analyze the reliability of the test of 8 throws of 3 different variants of handball throws in university students. The participants were 33 males, 20 ± 1.9 years; weight 72.39 ± 8.9 kg; height 176.75 ± 6.07 cm; BMI 23.14 ± 2.3. They were evaluated in 2 sessions separated from each other by a period of one week. The participants executed throws until 8 measurements were recorded in each of the tests, unspecific throws, in support and in the race with 3 steps; the launch speed was recorded with a radar behind the goal. The reliability of the average of the test scores of 8 measurements between the first session and the second was measured with a test-retest test. The following results were obtained: in the nonspecific launch, an ICC= (0.86) was obtained between 95% of confidence, one of CV= (7.43%) and one ES = (0.08). For the toss with support, an ICC = (0.94) was obtained at 95% confidence, one of CV = (4.71%) and an ES = (-0.09). For the running throw, an ICC = (0.96) was obtained at 95% confidence, one of CV = (4.00%) and one ES = (0.05). This study has shown that the test of 8 throws and the 3 variants is a reliable and stable performance measure for university-level students without experience in handball; in relation to the throw variables, all 3 were reliable. Only the nonspecific variable was lower compared to the supported and running pitch.


Resumo O estudo tem como objetivo analisar a confiabilidade do teste de 8 arremessos de 3 variantes diferentes de arremessos de handebol em estudantes universitários. 33 homens, 20 ±1,9 anos; peso 72,39±8,9 kg; altura 176,75 ±6,07 cm; IMC 23,14±2,3. Os participantes foram testados em 2 sessões separadas por um lapso de 1 semana. Os participantes executaram arremessos até poder registrar 8 medições em cada um dos testes, arremessos não específicos, com apoio e correndo com 3 passos. A velocidade de arremesso foi registrada com um radar pós-gol. A confiabilidade da média dos resultados dos testes de 8 medições entre a primeira sessão e a segunda com um teste de retorno, deu os seguintes resultados: no teste de lançamento não específico, foi obtido um ICC= (0,86) com 95% de confiança, um CV= (7,43%) e um ES= (0,08). Para o lançamento apoiado obtivemos um ICC= (0,94) a 95% de confiança, um CV= (4,71%) e um ES= (-0,09). Para o arremesso de corrida obtivemos um ICC= (0,96) a 95% de confiança, um CV= (4,00%) e um ES= (0,05). Este estudo mostrou que o teste de 8 lances e as 3 variantes é uma medida de desempenho confiável e estável para estudantes universitários sem experiência em handebol. Em relação às variáveis de arremesso, todas as 3 foram confiáveis, apenas a variável não específica foi menor em comparação com o arremesso com suporte e com corrida.


Subject(s)
Humans , Male , Adult , Sports , Track and Field , Core Stability
9.
Acta odontol. latinoam ; 35(2): 120-124, Sept. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1403033

ABSTRACT

ABSTRACT The aim of this study was to measure the fluoride (F) and silver (Ag) ion concentration and the pH, over time, of 2 solutions of 38% silver diamine fluoride (SDF) produced in Argentina. The brand Fluorsilver® was established as Group 1 (G1) (Densell), and the brand FAgamin® (Tedequim) as Group 2 (G2), each with two different lots. The following were determined at time 0 (t0) and 30 days after opening (t30): a) fluoride concentration (w/v) by visible spectrophotometry b) Ag content (w/v) by atomic absorption spectrophotometry c) pH. Results: The data in the freshly opened bottles were for G1 lot1/lot2: a) 0.96/1, b) 8.3/7.8, c).11.5/11.3; G2 lot1/lot2: a) 11.5/9.9, b) 39/39, c) 7/6,9; and after 30 days, G1 lot1/lot2: a) 0.85/0.81, b) 7.2/8.2, c) 11.3/11.6; G2 lot1/lot2: a) 9.35/8.43, b) 38/38, c) 7.6/7.6. Conclusion In relation to the expected values (5.0-5.9% fluoride and 24.4-28.8% silver), the average concentration of fluoride and silver ions was lower for G1, but higher for G2. The pH was alkaline for G1 and neutral for G2. Over the 30 days, the content of fluoride and silver tended to decrease.


RESUMEN El objetivo de este estudio fue medir las concentraciones de iones de fluoruro (F) y plata (Ag) y el pH, de 2 soluciones de diamino fluoruro de plata (SDF) al 38% producidas en Argentina. Se estableció como Grupo 1 (G1) la marca Fluorsilver® (Densell), y FAgamin® (Tedequim) como Grupo 2 (G2), cada uno con dos lotes diferentes. Se determinó: a) la concentración de fluoruro (p/v) por espectrofotometría visible, b) el contenido de Ag (p/v) por espectrofotometría de absorción atómica y c) el pH, y fue medido en un tiempo 0 (t0) y 30 días después de la apertura del frasco (t30). Resultado: En tiempo 0 para G1 lote1/lote2 fue: a) 0,96/1, b) 8,3/7,8 c).11,5/11,3 y G2 lote1/lote2: a) 11,5/9,9, b) 39/39, c) 7/6,9. A los 30 días G1 lote1/lote2: a) 0,85/0,81, b) 7,2/8,2, c) 11,3/11,6 y G2 lote1/lote2: a) 9,35/8,43, b) 38/38, c) 7,6/7,6. La concentración de iones de fluoruro y plata para G1 fue menor en relación a los valores esperados (5,0-5,9% de fluoruro y 24,4- 28.8% plata), sin embargo G2 obtuvo valores más altos. G1 muestra resultados de pH alcalino y G2 neutro. A lo largo de los 30 días, el contenido de fluoruro y plata tiende a disminuir.

10.
Braz. dent. j ; 33(3): 55-66, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384030

ABSTRACT

Abstract The objective of this study was to evaluate the effect of natural bleaching products on the color, whiteness, and superficial properties of dental enamel. Seventy fragments of bovine teeth were obtained (6mm x 6mm x 2mm). Initial surface roughness (Surfcorder SE1700, Kosakalab), microhardness (HMV-2, Shimadzu), color (EasyShade, VITA), and surface gloss (Micro-Gloss 45º BYK, Gardner) readings were done. Samples were separated into five groups (n=14) according to the treatments used: CT-conventional toothpaste (negative control); CH-charcoal; TU-turmeric; BP-banana peel, and CP16%-16% carbamide peroxide gel (positive control, 4 h/day for 14 days), and then brushed for 560 cycles (T1) and 1200 cycles (T2), equivalent to 14 and 30 days of brushing. New measurements were performed after T1 and T2. The whiteness index for dentistry change (∆WID) and Weight loss (Wl) were calculated. CP16% demonstrated the highest (p<.05) color change (ΔE00) and ∆WID (2-way ANOVA, Bonferroni, p<.05). Surface gloss alterations were lower for TU, CP16%, and BP. CT and CH increased surface roughness (p<.05). CP16% decreased enamel microhardness. CH presented medium abrasiveness, and CT and TU, low abrasiveness. The popular bleaching products were not efficient for tooth whitening. Furthermore, brushing with charcoal increased the enamel surface roughness, and CP16% decreased enamel microhardness over time


Resumo O objetivo deste estudo foi avaliar o efeito de produtos clareadores naturais na cor, efeito clareador e propriedades superficiais do esmalte dentário. Setenta fragmentos de dente bovino foram obtidos (6mm x 6mm x 2mm). Foram realizadas leituras iniciais de rugosidade de superfície (Surfcorder SE1700, Kosakalab), microdureza (HMV-2, Shimadzu), cor (EasyShade, VITA) e brilho (Micro-Gloss 45º BYK, Gardner). As amostras foram separadas em cinco grupos (n=14), de acordo com os tratamentos utilizados: DC - dentifrício convencional (controle negativo); CA - carvão ativado; CM - cúrcuma; CB - casca de banana e PC16% - gel de peróxido de carbamida a 16% (controle positivo, 4h/dia por 14 dias), foram então escovadas por 560 ciclos (T1) e 1200 ciclos (T2), equivalente a 14 e 30 dias de escovação. Novas leituras foram realizadas após T1 e T2. A alteração do whiteness index for dentistry (∆WID) e perda de massa (Pm) foram calculadas. PC16% demonstrou a maior (p<0,05) alteração de cor (ΔE00) e ∆WID (2-way ANOVA, Bonferroni, p<0,05). A alteração de brilho foi menor para CM, PC16% e CB. DC e CA aumentaram a rugosidade de superfície (p<0,05). PC16% diminuiu a microdureza do esmalte. CA apresentou abrasividade média, e DC e CM, baixa abrasividade. Os produtos clareadores populares não foram eficientes para clareamento dental. Ademais, a escovação com carvão ativado aumentou a rugosidade de superfície do esmalte dentário, e com maior tempo PC16% diminuiu a microdureza do esmalte.

11.
Odovtos (En línea) ; 24(2)ago. 2022.
Article in English | LILACS-Express | LILACS, SaludCR | ID: biblio-1386595

ABSTRACT

Abstract The aim of this in vitro study was to compare the long-term effect of overnight use of denture cleansers with different chemical compositions on the color stability of denture base polymers (DBPs). The four DBPs evaluated were PEEK (PK group), thermoinjection-molded polyamide (PA group), auto-polymerized polymethylmethacrylate (PMMA) (AP group), and heat-polymerized resin PMMA (HP group). The cleaning agents used were Corega tablet (CT), Protefix tablet (PT), and 0.5% sodium hypochlorite (NaOCl) solution (SH). Distilled water (DW) served as a control. Forty-eight disc-shaped specimens (10mm × 2mm) were prepared from each DBP and randomly immersed in the different storage media (n=12 in each group). Color measurements of the specimens before and after immersion in the denture cleansers were made using a spectrophotometer (VITA Easyshade V). The color changes were measured and recorded in L* a* b*. After 120 d, the CIEDE2000 formula was used to calculate color changes (ΔE00). For analysis of the data, a multivariate analysis of variance was used (p<0.05). The results of the statistical analysis revealed significant color change differences in the DBPs immersed in the various denture cleansers (p<0.05). Groups PA and PK showed the highest values for all solutions. AP-SH showed the highest ΔE00 value in group AP, no significant difference was found between other solutions. In group HP, there was no statistically significant difference between the average ΔE00 values of all solutions. Long-term daily use of the denture cleansers affected the color stability of all the DBPs, although the level of color change was acceptable. Laboratory and clinical studies on the color stability of PEEK are needed to confirm the results of this study.


Resumen El objetivo de este estudio in vitro fue comparar el efecto a largo plazo del uso nocturno de limpiadores de prótesis con diferentes composiciones químicas sobre la estabilidad del color de los polímeros base de prótesis (DBP). Los cuatro DBP evaluados fueron PEEK (grupo PK), poliamida moldeada por termoinyección (grupo PA), polimetilmetacrilato (PMMA) autopolimerizado (grupo AP) y resina PMMA termopolimerizada (grupo HP). Los agentes de limpieza utilizados fueron Corega (CT), Protefix (PT) y la solución de hipoclorito de sodio (NaOCl) al 0,5% (SH). El agua destilada (DW) sirvió de control. Se prepararon 48 especímenes en forma de disco (10mm × 2mm) de cada DBP y se sumergieron al azar en los diferentes medios de almacenamiento (n=12 en cada grupo). Las mediciones del color de las muestras antes y después de la inmersión en los limpiadores de dentaduras se realizaron con un espectrofotómetro (VITA Easyshade V). Los cambios de color se midieron y registraron en L* a* b*. Después de 120 d, se utilizó la fórmula CIEDE2000 para calcular los cambios de color (ΔE00). Para el análisis de los datos, se utilizó un análisis multivariante de la varianza (p<0,05). Los resultados del análisis estadístico revelaron diferencias significativas en el cambio de color de los DBP sumergidos en los distintos limpiadores de dentaduras (p<0,05). Los grupos PA y PK mostraron los valores más altos para todas las soluciones. AP-SH mostró el valor ΔE00 más alto en el grupo AP, no se encontraron diferencias significativas entre las demás soluciones. En el grupo HP, no hubo diferencias estadísticamente significativas entre los valores medios de ΔE00 de todas las soluciones. El uso diario a largo plazo de los limpiadores de dentaduras afectó a la estabilidad del color de todos los DBP, aunque el nivel de cambio de color fue aceptable. Se necesitan estudios de laboratorio y clínicos sobre la estabilidad del color del PEEK para confirmar los resultados de este estudio.


Subject(s)
Polymers , Prosthesis Coloring , Denture Cleansers , Polymethyl Methacrylate
12.
Psychol. av. discip ; 16(1): 71-81, ene.-jun. 2022. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1406459

ABSTRACT

Resumen La Regulación Emocional (RE) ha asumido relevancia en la psicología clínica. Su medición requiere de instrumentos adecuados a nivel psicométrico. Se examinaron la validez convergente e incremental del Cuestionario de Regulación Emocional (ERQ) en 224 personas entre 18 y 63 años (M = 32.04; DE = 11.51), y la estabilidad temporal en 52 participantes de 21 a 63 años (M = 30.46; DE = 10.65). Los resultados indicaron una estabilidad temporal moderada (.74) en el caso de la supresión expresiva y buena (.81) para la reevaluación cognitiva; también, validez convergente a través de asociaciones positivas entre la supresión expresiva y sintomatología depresiva y ansiógena. La reevaluación cognitiva se asoció negativamente a la sintomatología depresiva, pero no con la ansiógena. Mediante una regresión múltiple jerárquica se obtuvo evidencia de la validez incremental sobre la sintomatología depresiva (R2 ajustado = .44; p < .001). En conclusión, la presente investigación obtuvo nuevas evidencias acerca de las propiedades psicométricas de la versión argentina del ERQ, puntualmente, acerca de su estabilidad temporal, su validez convergente y su validez incremental.


Abstract Emotional Regulation (ER) has assumed relevance in clinical psychology. Its measurement requires appropriate instruments at a psychometric level. The convergent and incremental validity of the Emotional Regulation Questionnaire (ERQ) was examined in 224 people between 18 and 63 years old (M = 32.04; SD = 11.51), and temporal stability in 52 participants between 21 and 63 years old ( M = 30.46, SD = 10.65). The results indicated moderate temporal stability (.74) in the case of expressive suppression and good (.81) for cognitive reappraisal. Also convergent validity through positive associations between expressive suppression and depressive and anxiogenic symptomatology. Cognitive reappraisal was negatively associated with depressive symptomatology, but not with anxiety. Hierarchical multiple regression evidence of incremental validity on depressive symptomatology was obtained (adjusted R2 = .44; p < .001). In conclusion, this research obtained new evidence about the psychometric properties of the Argentine version of the ERQ. Specifically, about its temporal stability, its convergent validity and its incremental validity.

13.
Rev. cuba. med. mil ; 51(2): e1917, abr.-jun. 2022. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1408827

ABSTRACT

ABSTRACT Introduction: Implant stability can be measured at the moment of implant placement or once the osseointegration process is in progress. Many factors should be considered, including bone quality, osteotomy preparation, implant design, implant surface enhancement, and implant length and diameter. Objective: Determine the influence of implant length on primary and secondary stability in type II and type III bones using resonance frequency analysis method. Methods: A prospective study was conducted in the department of Oral maxillofacial Implantology at the School of Dentistry of the University of Chile between April 2006 and June 2007. 38 screw type implants were placed in the maxilla and mandible, in type II and type III bones. 21 implants had an average contact area of 237 mm2 including 2 sizes (3.75mm and a length of 13mm and 15mm) and 17 implants had an average contact area of 129 mm2 (diameter of 3.75mm and a length of 7mm). Implant primary stability was measured by the Implant Stability Quotient value. Resonance frequency measurements were recorded using Osstell™ Mentor. Secondary implant stability was recorded between 4 to 6 months after the implant placement. Results: For implants with an average contact area of 237 mm2 the stability 1 average value was 71,37 and the stability 2 average value was 66,6. For implants with an average contact area of 129 mm2 the stability 1 average value was 67,47 and the stability 2 average value was 68,08. Conclusion: Implant length does not influence primary and secondary stability in type II and type III bones.


RESUMEN Introducción: La estabilidad del implante se puede medir al momento de colocarlo o una vez que el proceso de osteointegración está en curso. Se deben considerar muchos factores, incluida la calidad ósea, la superficie y diseño del implante, la longitud y el diámetro. Objetivo: Determinar la influencia de la longitud del implante en la estabilidad primaria y secundaria en huesos tipo II y tipo III mediante el método de análisis de frecuencia de resonancia. Métodos: Estudio prospectivo en el departamento de Implantología Oral maxilofacial de la Facultad de Odontología de la Universidad de Chile, entre abril 2006 y junio 2007. Se colocaron 38 implantes tipo tornillo en maxilar y mandíbula, en huesos tipo II y tipo III. 21 implantes tenían un área de contacto promedio de 237 mm2, incluidos 2 tamaños (3,75 mm y una longitud de 13 mm y 15 mm) y 17 implantes tenían un área de contacto promedio de 129 mm2 (diámetro de 3,75 mm y una longitud de 7 mm). La estabilidad primaria del implante se midió mediante el valor cociente de estabilidad del implante y la estabilidad secundaria. Resultados: Para implantes con un área de contacto promedio de 237 mm2, la estabilidad 1 fue de 71,37 y la estabilidad 2 fue de 66,6. Para implantes con un área de contacto promedio de 129 mm2, la estabilidad 1 fue de 67,47 y la estabilidad 2 fue de 68,08. Conclusión: La longitud del implante no influye en la estabilidad primaria y secundaria en los huesos tipo II y tipo III.

14.
Medicina (B.Aires) ; 82(supl.1): 43-47, mar. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1375893

ABSTRACT

Resumen Las características de individuos con trastornos del espectro Autista (TEA) persistente (TEA-P) o con TEA remitente (TEA-R) en el tiempo son poco conocidas. Este estudio longitudinal se planteó con tres objetivos: 1) determinar la tasa de persistencia/recuperación en la adolescencia de niños con diagnós tico TEA; 2) comparar el funcionamiento ejecutivo (FE), manifestaciones socio-adaptativas y conductuales de adolescentes TEA-P y TEA-R; y 3) identificar el porcentaje de individuos de los grupos TEA-P y TEA-R con puntuaciones normalizadas en FE y manifestaciones socio-adaptativas y conductuales en la infancia (T1) y en la adolescencia (T2). La muestra en el Tiempo 1 estuvo integrada por 45 niños con TEA (edad 7 a 11 años) de los que 32 mantenían el diagnóstico del trastorno 5 años después. Los padres y profesores cumplimentaron cuestionarios de FE, teoría de la mente (ToM), manifestaciones socio-adaptativas y conductuales en T1 y en T2. El grupo con TEA-P presentó significativamente más problemas y peor evolución en FE, características socio-adaptativas y conductuales que el grupo TEA-R. Los hallazgos destacan la variabilidad de la trayectoria evolutiva del TEA y la necesidad de realizar un seguimiento psicoeducativo y médico frecuente en este trastorno del neurodesarrollo.


Abstract The characteristics of individuals with persis tent ASD (ASD-P) and remittent ASD (ASD-R) are little known. This longitudinal study had threeobjectives1) To determine the persistence and recovery in children with autism spectrum disorder diagnosis in adolescence: 2) To compare executive functioning (EF), socio-adaptive and behavioral manifestations of ASD-P and ASD-R adolescents; and 3) to identify the percentage of normalized individuals in ADS-P and ADS-R groups in EF, socio-adaptive and behavioral manifestation in childhood and adolescence. The sample at T1 was comprised of 45 children with ASD (aged 7-11), maintaining 32 ASD diagnosis five years later. Parents and teachers completed questionnaires on EF, theory of mind, socio-adaptive and behavior difficulties, at both time points. The ASD-P group presented significantly more problems than group ASD-Rand showed worst evolution in EF, socio-adaptive and behavioral domains. Our findings highlight the variability of developmental trajectories of children with ASD.

15.
Rev. inf. cient ; 101(1)feb. 2022.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1409514

ABSTRACT

RESUMEN Introducción: La calidad de la atención médica se relaciona directamente con el clima laboral adecuado y la satisfacción del personal de la salud. Con la aparición de la COVID-19 el clima laboral en las instituciones de salud se vio violentado. Objetivo: Identificar los factores que influyen en el clima laboral de las instituciones de salud pública y privadas de Santo Domingo de los Tsáchilas, Ecuador, durante el periodo junio-agosto de 2021. Método: Estudio con enfoque cuantitativo de alcance correlacional y diseño transeccional, en 349 trabajadores de la salud, a los que se les aplicó un cuestionario de 25 preguntas que midieron factores, como: riesgo al contagio, jornada laboral, recursos médicos y estabilidad laboral. Los resultados del estudio fueron analizados estadísticamente a través de SPPS 20 y AMOS 24, con el desarrollo anterior de alfa de Cronbach. Resultados: El 94 % de los participantes consideró como inadecuado el clima laboral de sus instituciones, mientras que el 6 % manifestó que no. Predominaron las féminas y los de 22-35 años. Todas las variables del modelo hipotetizado superaron el 0,70 y el alfa de Cronbach total alcanzó un 0,728; el modelo hipotetizado cumplió con la validez convergente y discriminante de las variables. El riesgo de contagio arrojó un valor de β=0,148, mientras que la jornada laboral resultó con β=0,010, recursos médicos β=0,006 y estabilidad laboral β=0,007. Conclusiones: Los hallazgos determinaron que el riesgo al contagio es el factor más influyente en el clima laboral de las instituciones objeto de estudio durante los inicios de la pandemia por la COVID-19.


ABSTRACT Introduction: The quality of medical care is directly related to the appropriate work environment and the satisfaction of the health staff. With the appearance of COVID-19, the work environment in health institutions has worsened. Objective: To identify the factors that influence the work environment of the public and private health institutions of Santo Domingo de los Tsáchilas, Ecuador, during the period June-August 2021. Method: Implementation of a study with a quantitative approach of correlational scope and transectional design in 349 health workers, to whom a 25-questions questionnaire was applied, that measured factors such as: contagion risk, working hours, medical resources and job stability. The results of the study were statistically analyzed through SPPS 20 and AMOS 24, with the previous development of Cronbach's alpha. Results: 94% of the participants considered the work environment of their institutions as inappropriate, while 6% said they did not. Females, and ages ranging between 22-35 years predominated. All the variables of the hypothesized model exceeded 0.70 and the total Cronbach's alpha reached 0.728; the hypothesized model met the convergent and discriminant validity of the variables. The risk of contagion yielded a value of β=0.148, while the working day resulted with β=0.010, medical resources β=0.006 and job stability β=0.007. Conclusions: The findings determined that the risk of contagion is the most influential factor in the work environment of the institutions under study during the beginning of the COVID-19 pandemic.


RESUMO Introdução: A qualidade da assistência médica está diretamente relacionada ao ambiente de trabalho adequado e à satisfação do pessoal de saúde. Com o surgimento da COVID-19, o ambiente de trabalho nas instituições de saúde foi violado. Objetivo: Identificar os fatores que influenciam o ambiente de trabalho das instituições públicas e privadas de saúde de Santo Domingo de los Tsáchilas, Equador, no período de junho a agosto de 2021. Método: Estudo com abordagem quantitativa de escopo correlacional e delineamento transversal, em 349 trabalhadores de saúde, aos quais foi aplicado um questionário de 25 questões que mediam fatores como: risco de contágio, jornada de trabalho, recursos médicos e estabilidade no emprego. Os resultados do estudo foram analisados estatisticamente por meio do SPPS 20 e AMOS 24, com o desenvolvimento prévio do alfa de Cronbach. Resultados: 94% dos participantes consideraram o ambiente de trabalho de suas instituições inadequado, enquanto 6% disseram que não. Predominaram mulheres e pessoas de 22 a 35 anos. Todas as variáveis do modelo hipotético ultrapassaram 0,70 e o alfa de Cronbach total atingiu 0,728; o modelo hipotético atendeu à validade convergente e discriminante das variáveis. O risco de contágio resultou em β=0,148, enquanto a jornada de trabalho resultou em β=0,010, recursos médicos β=0,006 e estabilidade no trabalho β=0,007. Conclusões: Os achados determinaram que o risco de contágio é o fator mais influente no ambiente de trabalho das instituições em estudo durante o início da pandemia do COVID-19.

16.
Rev. latinoam. enferm. (Online) ; 30: e3620, 2022. tab, graf
Article in Portuguese | LILACS, BDENF | ID: biblio-1389119

ABSTRACT

Resumo Objetivo: verificar a estabilidade do cloridrato de vancomicina em soluções de selo antimicrobiano sem e com associação de heparina sódica segundo a temperatura e tempo de associação. Método: estudo experimental delineado para análise de potencial hidrogeniônico e concentração por cromatografia líquida de alta eficiência de soluções de cloridrato de vancomicina (n=06) e cloridrato de vancomicina e heparina sódica (n=06). Submeteram-se as soluções estudadas à ausência de luz, 22°C e 37°C. Análises em triplicadas (n=192) ocorreram no momento inicial (T0), três (T3), oito (T8) e 24 horas (T24) após preparo. Os dados foram submetidos à análise de variância (p≤0,05). Resultados: a concentração do antimicrobiano a 22°C apresentou redução (T0-T8) e posterior elevação (T24); o potencial hidrogeniônico diminuiu significativamente ao longo do tempo. Em 37°C a concentração aumentou em até T3 e reduziu em T24, com redução de potencial hidrogeniônico até 24 horas. A concentração das soluções de cloridrato de vancomicina e heparina sódica apresentaram variação com redução a 22°C acompanhada de aumento de potencial hidrogeniônico. Observou-se formação de precipitado por inspeção visual da associação cloridrato de vancomicina e heparina sódica (T3). Conclusão: evidenciou-se estabilidade farmacológica do cloridrato de vancomicina (5 mg/mL) e incompatibilidade física com heparina sódica (100 UI/mL) após três horas de associação nas soluções de selo antimicrobiano estudadas.


Abstract Objective: to verify the stability of vancomycin hydrochloride in antimicrobial seal solutions with and without association of heparin sodium according to temperature and association time. Method: an experimental study designed for the analysis of hydrogenionic potential and concentration by means of high-efficiency liquid chromatography of vancomycin hydrochloride (n=06) and vancomycin hydrochloride and heparin sodium (n=06). The solutions studied were submitted to absence of light, as well as to 22°C and 37°C. Analyses in triplicate (n=192) were performed at the initial moment (T0) and three (T3), eight (T8) and 24 hours (T24) after preparation. The data were submitted to analysis of variance (p≤0.05). Results: concentration of the antimicrobial at 22°C presented a reduction (T0-T8) and a subsequent increase (T24); hydrogenionic potential decreased significantly over time. At 37°C, the concentration increased up to T3 and decreased at T24, with a reduction of hydrogenionic potential up to 24 hours. Concentration of the vancomycin hydrochloride and heparin sodium solutions varied with a reduction at 22°C, accompanied by increased hydrogenionic potential. Precipitate formation was observed by visual inspection of the vancomycin hydrochloride-heparin sodium association (T3). Conclusion: pharmacological stability of vancomycin hydrochloride (5 mg/mL) and physical incompatibility with heparin sodium (100 IU/mL) were evidenced after three hours of association in the antimicrobial seal solutions studied.


Resumen Objetivo: verificar la estabilidad del clorhidrato de vancomicina en soluciones de sellado antimicrobiano solo y combinado con heparina sódica según la temperatura y el tiempo de combinación. Método: estudio experimental diseñado para analizar el potencial de hidrógeno y la concentración por cromatografía líquida de alta resolución de soluciones de clorhidrato de vancomicina (n=06) y de clorhidrato de vancomicina y heparina sódica (n=06). Las soluciones estudiadas fueron sometidas a ausencia de luz, 22°C y 37°C. Se realizaron análisis por triplicado (n=192) en el momento inicial (T0), a las tres (T3), ocho (T8) y 24 horas (T24) después de la preparación. Los datos fueron sometidos a análisis de varianza (p≤0,05). Resultados: la concentración de antimicrobiano a 22°C mostró una reducción (T0-T8) y un posterior aumento (T24); el potencial de hidrógeno disminuyó significativamente con el tiempo. A 37°C, la concentración aumentó hasta T3 y disminuyó en T24, el potencial de hidrógeno disminuyó hasta las 24 horas. La concentración de las soluciones de clorhidrato de vancomicina y heparina sódica mostró variación con la reducción a 22°C acompañada de un aumento del potencial de hidrógeno. Mediante inspección visual se observó la formación de un precipitado al combinar clorhidrato de vancomicina y heparina sódica (T3). Conclusión: el clorhidrato de vancomicina (5 mg/ml) presentó evidencia de estabilidad farmacológica e incompatibilidad física con la heparina sódica (100 UI/ml) después de las tres horas de haberse realizado la combinación en las soluciones de sellado antimicrobiano estudiadas.


Subject(s)
Heparin , Vancomycin/chemistry , Drug Stability , Catheter-Related Infections , Central Venous Catheters
17.
São Paulo; s.n; s.n; 2022. 93 p. tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-1392262

ABSTRACT

O número de pessoas utilizando substâncias ilícitas de forma recreativa aumenta a cada ano, chamando a atenção de estudiosos de diversas áreas do conhecimento. Com isso, a demanda de exames toxicológicos exigida para trabalhadores, vítimas de crimes e esportistas também tem crescido. A amostra biológica mais utilizada para análises toxicológicas continua sendo a urina, visto que sua obtenção é menos invasiva, possibilita coletar grande volume de amostra e pode-se detectar substâncias até dias após ter ocorrido a exposição ou consumo. Entretanto, estas amostras necessitam de um grande volume físico para serem armazenadas e transportadas aos laboratórios, devendo ser mantidas em temperatura baixa e controlada para conservação. Outro ponto a se considerar é a quantidade de amostra insuficientemente coletada, ou extravasamento do conteúdo, contaminando outras amostras e muitas vezes, inviabilizando a análise. Uma alternativa recente para tais problemas é utilizar a técnica chamada de dried urine spots (DUS), onde poucos microlitros de urina são colocados em um papel absorvente e secos sob temperatura ambiente, preservando de agentes degradantes os componentes presentes na urina. Assim, o objetivo deste trabalho é avaliar a estabilidade das substâncias do presente estudo em alta temperatura, temperatura ambiente e em temperaturas de 4°C e -20°C. Para este fim, foi necessário desenvolver, validar e aplicar métodos de extração e determinação de anfetaminas e produtos de biotransformação de cocaína e tetraidrocanabinol carboxílico (THCCOOH) em amostras dried urine spot, utilizando cromatografia líquida acoplada à espectrometria de massas. Os picos foram identificados por UPLC-ESI-MS/MS, com tempo total de 5 mins utilizando fase A- água, formiato de amônio e 0,1% ácido fórmico, e B- metanol: acetonitrila (6:4) + 0,1% de ácido fórmico. A extração foi feita utilizando acetonitrila: metanol: acetona (1:1:1) +ácido fórmico 0,1%. Não foi possível iniciar a validação de THCCOOH, visto uma possível complexação do analito com o papel. Para as outras substâncias, o método cromatográfico desenvolvido se mostrou eficiente e seletivo, com LOD e LOQ de 10 ng/mL para todos os analitos, sendo linear até 1000 ng/mL, atendeu as especificações de precisão e exatidão e carryover. As amostras permaneceram estáveis ao longo de 32 dias nas temperaturas estudadas, demonstrando a segurança em se utilizar a técnica de DUS para armazenamento e transporte de amostras biológicas dentro da faixa de temperatura do estudo até 32 dias


The number of people using illegal substances in a recreational way increases each year, drawing the attention of scholars from different areas of knowledge. As a result, the demand for workplaces drug tests, toxicological tests for victims of crimes and dopping has also grown. The biological sample most used for toxicological tests remains urine, since obtaining it is less invasive, it is possible to collect a large volume of sample and it is possible to detect substances up to days after exposure or consumption has occurred. However, these samples require a large physical volume to be stored and transported to the laboratories, and must be kept at a low temperature for conservation. Another point to consider is the amount of sample insufficiently collected, or leakage of the content, causing contamination of other samples and often making the analysis unfeasible. A recent alternative to such problems is to use "dried urine spots" (DUS), where few microliters of urine are placed on absorbent paper and dried at room temperature, preserving the components present in the urine from degrading agents. Thus, the objective of this work is to evaluate the stability of the substances in this study at high temperature, room temperature and at temperatures of 4°C and -20°C. For this purpose, it was necessary to develop, validate and apply methods of extraction and determination of amphetamines and biotransformation products of cocaine and carboxylic tetrahydrocannabinol (THCCOOH) in dried urine spot samples, using liquid chromatography coupled to mass spectrometry (LC-MS). The peaks were identified liquid chromatography coupled to a mass spectrometer (UPLC-ESI-MS/MS), with a total time of 5 mins using phase A- water, ammonium formate and 0.1% formic acid, and B- methanol: acetonitrile (6:4) + 0.1% formic acid. Extraction was done using acetonitrile: methanol: acetone (1:1:1) + 0.1% formic acid. It was not possible to perform the validation of THCCOOH, given a possible complexation of the analyte with the paper. To the others substances, the chromatographic method developed proved to be efficient and selective, with LOD and LOQ of 10 ng/mL for all analytes, being linear up to 1000 ng/mL, meeting the specifications of precision and accuracy and carryover. The samples remained stable for 32 days at the temperatures studied, demonstrating the safety of using the DUS technique for storage and transport of biological samples until 32 days on temperature range studied


Subject(s)
Dronabinol/adverse effects , Biotransformation , Cocaine/agonists , Amphetamines/analysis , Mass Spectrometry/methods , Urine/physiology , Chromatography, Liquid/methods
18.
São Paulo; s.n; s.n; 2022. 93 p. tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-1396684

ABSTRACT

O número de pessoas utilizando substâncias ilícitas de forma recreativa aumenta a cada ano, chamando a atenção de estudiosos de diversas áreas do conhecimento. Com isso, a demanda de exames toxicológicos exigida para trabalhadores, vítimas de crimes e esportistas também tem crescido. A amostra biológica mais utilizada para análises toxicológicas continua sendo a urina, visto que sua obtenção é menos invasiva, possibilita coletar grande volume de amostra e pode-se detectar substâncias até dias após ter ocorrido a exposição ou consumo. Entretanto, estas amostras necessitam de um grande volume físico para serem armazenadas e transportadas aos laboratórios, devendo ser mantidas em temperatura baixa e controlada para conservação. Outro ponto a se considerar é a quantidade de amostra insuficientemente coletada, ou extravasamento do conteúdo, contaminando outras amostras e muitas vezes, inviabilizando a análise. Uma alternativa recente para tais problemas é utilizar a técnica chamada de dried urine spots (DUS), onde poucos microlitros de urina são colocados em um papel absorvente e secos sob temperatura ambiente, preservando de agentes degradantes os componentes presentes na urina. Assim, o objetivo deste trabalho é avaliar a estabilidade das substâncias do presente estudo em alta temperatura, temperatura ambiente e em temperaturas de 4°C e -20°C. Para este fim, foi necessário desenvolver, validar e aplicar métodos de extração e determinação de anfetaminas e produtos de biotransformação de cocaína e tetraidrocanabinol carboxílico (THCCOOH) em amostras dried urine spot, utilizando cromatografia líquida acoplada à espectrometria de massas. Os picos foram identificados por UPLC-ESI-MS/MS, com tempo total de 5 mins utilizando fase A- água, formiato de amônio e 0,1% ácido fórmico, e B- metanol: acetonitrila (6:4) + 0,1% de ácido fórmico. A extração foi feita utilizando acetonitrila: metanol: acetona (1:1:1) +ácido fórmico 0,1%. Não foi possível iniciar a validação de THCCOOH, visto uma possível complexação do analito com o papel. Para as outras substâncias, o método cromatográfico desenvolvido se mostrou eficiente e seletivo, com LOD e LOQ de 10 ng/mL para todos os analitos, sendo linear até 1000 ng/mL, atendeu as especificações de precisão e exatidão e carryover. As amostras permaneceram estáveis ao longo de 32 dias nas temperaturas estudadas, demonstrando a segurança em se utilizar a técnica de DUS para armazenamento e transporte de amostras biológicas dentro da faixa de temperatura do estudo até 32 dias


The number of people using illegal substances in a recreational way increases each year, drawing the attention of scholars from different areas of knowledge. As a result, the demand for workplaces drug tests, toxicological tests for victims of crimes and dopping has also grown. The biological sample most used for toxicological tests remains urine, since obtaining it is less invasive, it is possible to collect a large volume of sample and it is possible to detect substances up to days after exposure or consumption has occurred. However, these samples require a large physical volume to be stored and transported to the laboratories, and must be kept at a low temperature for conservation. Another point to consider is the amount of sample insufficiently collected, or leakage of the content, causing contamination of other samples and often making the analysis unfeasible. A recent alternative to such problems is to use "dried urine spots" (DUS), where few microliters of urine are placed on absorbent paper and dried at room temperature, preserving the components present in the urine from degrading agents. Thus, the objective of this work is to evaluate the stability of the substances in this study at high temperature, room temperature and at temperatures of 4°C and -20°C. For this purpose, it was necessary to develop, validate and apply methods of extraction and determination of amphetamines and biotransformation products of cocaine and carboxylic tetrahydrocannabinol (THCCOOH) in dried urine spot samples, using liquid chromatography coupled to mass spectrometry (LC-MS). The peaks were identified liquid chromatography coupled to a mass spectrometer (UPLC-ESI-MS/MS), with a total time of 5 mins using phase A- water, ammonium formate and 0.1% formic acid, and B- methanol: acetonitrile (6:4) + 0.1% formic acid. Extraction was done using acetonitrile: methanol: acetone (1:1:1) + 0.1% formic acid. It was not possible to perform the validation of THCCOOH, given a possible complexation of the analyte with the paper. To the others substances, the chromatographic method developed proved to be efficient and selective, with LOD and LOQ of 10 ng/mL for all analytes, being linear up to 1000 ng/mL, meeting the specifications of precision and accuracy and carryover. The samples remained stable for 32 days at the temperatures studied, demonstrating the safety of using the DUS technique for storage and transport of biological samples until 32 days on temperature range studied


Subject(s)
Dronabinol/adverse effects , Biotransformation , Cocaine/adverse effects , Amphetamines/adverse effects , Mass Spectrometry/methods , Urine , Pharmaceutical Preparations/administration & dosage , Chromatography, Liquid/methods , Occupational Groups/classification
19.
Braz. J. Pharm. Sci. (Online) ; 58: e20570, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1403683

ABSTRACT

Abstract A stability indicating UPLC method has been developed and validated for the simultaneous determination of fosnetupitant and palonosetron in bulk and in injection dosage form. This combination is used for the prevention of acute and delayed nausea and vomiting associated with initial and repeated courses of highly emetogenic chemotherapy for cancer. The chromatographic analysis was performed on an HSS, RP C18 column (2.1 x 100 mm, 1.8 µm) with an isocratic mobile phase composed of 0.25 M potassium dihydrogen orthophosphate buffer (pH 6.5), pH adjusted with dilute sodium hydroxide:acetonitrile (55:45 v/v), at a flow rate of 0.5 mL/min, and the eluents were monitored at an isosbestic point of 286 nm. The developed method was validated according to the ICH guidelines pertaining to specificity, precision, accuracy, linearity and robustness, and the stability indicating nature of the method was established by forced degradation studies. The retention times of fosnetupitant and palonosetron were observed at 1.390 and 2.404 min, respectively. The developed method proved to be accurate and precise. Linearity was established between 4.70 and 14.10 µg/mL for fosnetupitant and between 0.05 and 0.15 µg/mL for palonosetron. The LOD and LOQ were 0.115 and 0.385 µg/mL, respectively, for fosnetupitant, and 0.005 and 0.016 µg/mL, respectively, for palonosetron. Therefore, the proposed UPLC method was reliable, reproducible, precise and sensitive for the quantification of fosnetupitant and palonosetron.

20.
Braz. J. Pharm. Sci. (Online) ; 58: e191088, 2022. graf
Article in English | LILACS | ID: biblio-1394055

ABSTRACT

Abstract The objective of this study was to determine the influence of nonionic surfactants on the effectiveness of preservatives used in emulsions containing high surfactant content. Mixtures of different concentrations were prepared between polyethoxylated (40) hydrogenated castor oil (PHCO) and polyoxyethylene sorbitan monooleate (PSO), with methylparaben, phenoxyethanol, methylparaben, ethylparaben, propylparaben, and isobutylparaben (PMEPBI) blend, phenoxyethanol and benzoic acid (BP) blend, and phenoxyethanol and caprylyl glycol (PC) blend. Subsequently, the compatibility of the formulation ingredients and the effectiveness of the preservatives were evaluated by the challenge test. It was found that PHCO and PSO inactivated the antimicrobial action of methylparaben and PMEPBI. Paraben-free preservatives BP and PC had less influence on surfactants than systems containing parabens. When incorporated into microemulsions and nanoemulsions containing 40% and 20% surfactants, methylparaben and BP 0.2% and 0.5% were only effective against Aspergillus niger. The PMEPBI 0.2% was effective as a preservative in nanoemulsified formulations against A. niger, Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus. The results demonstrate that the efficacy of the preservative system in formulations containing nonionic surfactant excipients depends on the type of excipient, the components of the formulation, the preservative systems composition, the excipient to preservative ratio, and the availability in the formulation.


Subject(s)
Polysorbates/pharmacology , Surface-Active Agents/pharmacology , Castor Oil/pharmacology , Additives in Cosmetics , Excipients/pharmacology , Effectiveness , Colony Count, Microbial , Microbial Sensitivity Tests , Cosmetic Stability
SELECTION OF CITATIONS
SEARCH DETAIL