ABSTRACT
Aiming at the problem of large force tracking errors caused by environmental stiffness changes when dual-arm robot is assisting in opening soft tissues in head and neck surgery,an adaptive admittance control strategy based on radial basis function(RBF)neural network is proposed for reducing force tracking error and improving system response speed.By using RBF neural network to adjust admittance parameters online during surgery,the adaptability of the robotic arm to different contact conditions and operation requirements is improved,thereby realizing fast and accurate force tracking.The simulation experiment introduces the adaptive admittance control strategy based on RBF neural network into the dual-arm force synchronous admittance control system and compares it with the traditional fixed-parameter admittance control to prove its contact force control effect under the condition of variable contact environment parameters.The results demonstrate that the adaptive admittance control strategy based on RBF neural network can effectively improve the force tracking accuracy,response speed and anti-interference capability of dual-arm surgical robot.
ABSTRACT
A non-bracket terminal tracer equipment with multi-angle active light source array is developed to reduce the effects of view obstruction on robot navigation.The multiple-angle light source array is established using a large prism and a small prism,and then the positions of the mechanical arm and the tool center point are calculated via the cooperation of binocular cameras.A simple model built with COMSOL software is used to verify the signal coverage of the tracer equipment.The experiments conducted for signal coverage and static positioning demonstrate its effectiveness and stability,suggesting that the tracer equipment can meet the task requirements of the surgical robot.
ABSTRACT
Objective:To analyze and compare the clinical efficacy of robot-assisted and conventional navigation-assisted percutaneous minimally invasive pedicle screw placement in the treatment of thoracolumbar fractures and to provide reference for clinical treatment decisions.Methods:A literature search was performed in China National Knowledge Infrastructure(CNKI),VIP,Wanfang and English databases PubMed and Web of science by using the keywords"vertebral pedicle screws,"and"robot"in Chinese and"robot"and"pedicle screws"in English.The search time in both Chinese and English was from the establishment of the database to December 2022.The relevant clinical studies on robot-assisted and traditional navigation-assisted percutaneous minimally invasive pedicle screw placement for the treatment of thoracolumbar cone fractures were collected.Cochrane Scale and Newcastle-Ottawa Scale(NOS)were used to evaluate the quality of literatures and meta-analysis was carried out.The clinical effects of robot-assisted and traditional navigation-assisted surgery was compared.Results:A total of 15 articles were included in the study.Compared with traditional navigation-assisted percutaneous minimally invasive pedicle screw placement,robotic-assisted surgery resulted in shorter operative time[WMD=-11.45,95% CI(-18.94~-3.95),P<0.05],less intraoperative bleeding[WMD=-19.11,95% CI(-27.51~-10.70),P<0.001],higher screw placement accuracy[number of grade A nails:RR=1.20,95% CI(1.16~1.25),P<0.001;number of grade A+B nails:RR=1.09,95% CI(1.07~1.11),P<0.001],and fewer complications[RR=0.35,95% CI(0.13~0.93),P<0.05].The difference in hospitalization time was not statistically significant(P>0.05).Conclusion:In percutaneous minimally invasive pedicle screw placement for the treatment of thoracolumbar fractures,robot-assisted surgery has advantages over navigation-assisted surgery in terms of operative time,intraoperative bleeding,placement accuracy and complications.
ABSTRACT
ObjectiveTo compare the effectiveness and safety of one-lung ventilation and small tidal volume two-lung ventilation anesthesia methods in the training of minimally invasive thoracic surgery on experimental pigs.MethodsForty experimental pigs undergoing robotic thoracic surgery were randomly divided into two groups: two-lung ventilation group (n=20) and one-lung ventilation group (n=20). The two-lung ventilation group underwent single-lumen tracheal intubation, utilizing a small tidal volume with a fast respiratory rate combined with carbon dioxide pneumothorax for anesthesia ventilation during the operation. The one-lung ventilation group received one-lung ventilation using a double-lumen bronchial catheter placed under fiberoptic bronchoscopic guidance. The anesthesia implementation indexes from the two groups were compared, including the values of vital signs such as operative heart rate (HR), noninvasive mean blood pressure (MAP), end-tidal carbon dioxide (ETCO2), and oxygen saturation (SpO2), as well as the assessment of surgical training performance.Results The intubation success rate for animals in both groups was 100%, with no intraoperative deaths. The intubation completion time was significantly shorter in the two-lung ventilation group compared to the one-lung ventilation group (P < 0.001). Within each group, SpO2 levels were significantly higher in the two-lung ventilation group at 30 minutes after the start of thoracic surgery (T1) and at surgery completion (T3) compared to 60 minutes after the start of surgery (T2) (P<0.05). ETCO2, HR, and MAP were significantly higher at T2 and T3 compared to T1 (P<0.05). In the one-lung ventilation group, SpO2 levels were significantly higher at T1 and T3 compared to T2 (P<0.05), while ETCO2 levels gradually increasing over time (P<0.05). In the between-group comparisons at the same time points, SpO2 levels of the two-lung ventilation group were significantly higher than those of the one-lung ventilation group at all time points (T1, T2, T3) (P<0.05).Conclusion Both one-lung ventilation and two-lung ventilation anesthesia methods are effective and safe for use in surgical training, with controllable effects on intraoperative animal vital signs and minimal impact on surgical operation training, meeting the needs of robotic thoracic surgery training. One-lung ventilation provides a better experience during pneumonectomy procedures, while small tidal volume two-lung ventilation is easier to implement and does not require additional equipment purchase, making it a feasible supplemental anesthesia option for thoracoscopic surgery on experimental pigs.
ABSTRACT
Objective:To retrospectively evaluate the clinical outcomes of autonomous dental implant robot(ADIR)assisted implant surgery in 1-year follow-up.Methods:20 patients with tooth missing underwent implantation surgery by ADIR were incuded.The plat-form deviation,apex deviation and angular deviation of the implants were analyzed.The marginal bone height and peri-implant soft tis-sue health were measured and observed immediately,6 months and 12 months after the restoration.Results:The platform deviation,apex deviation and angular deviation of 20 implants at the 3 follow-up examinations were(0.34±0.11)mm,(0.34±0.15)mm and(0.82°±0.38°),respectively.There was no significant difference in the accuracy of different implant diameter and length(P>0.05).During the follow-up period,all implants had successful osseointegration,stable marginal bone height,and acceptable peri-implant soft tissue condition.Conclusion:The 1-year follow-up indicates that ADIR can achieve promising clinical performance.Long-term follow-up studies are still necessary for verification.
ABSTRACT
In recent years, with the rapid development of Chinese domestic surgical robot technology and the expansion of the application market, the "industry-university-research-medicine" collaborative innovation transformation mode has gradually developed and formed. Medical institutions play an important role in multi-party cooperation with enterprises, universities, and research institutes, as well as in product planning, technology research and development, achievement transformation, and personnel training. On the basis of reviewing the current situation of the development of the "industry-university-research-medicine" collaborative innovation transformation mode of domestic surgical robots, this study explores the multiple roles played by medical institutions in this mode and challenges, further putting forward corresponding recommendations.
Subject(s)
Humans , Robotics , Universities , Medicine , Industry , TechnologyABSTRACT
Robotic puncture system has been widely used in modern minimally invasive surgery, which usually uses hand-eye calibration to calculate the spatial relationship between the robot and the optical tracking system. However, the hand-eye calibration process is time-consuming and sensitive to environmental changes, which makes it difficult to guarantee the puncture accuracy of the robot. This study proposes an uncalibrated positioning method for puncture robot based on optical navigation. The method divides the target path positioning into two stages, angle positioning and position positioning, and designs angle image features and position image features respectively. The corresponding image Jacobian matrix is constructed based on the image features and updated by online estimation with a cubature Kalman filter to drive the robot to perform target path localization. The target path positioning results show that the method is more accurate than the traditional hand-eye calibration method and saves significant preoperative preparation time by eliminating the need for calibration.
Subject(s)
Robotics , Robotic Surgical Procedures , Calibration , Minimally Invasive Surgical Procedures , Optical DevicesABSTRACT
Vascular interventional surgery is an important means to treat cardiovascular and cerebrovascular diseases, but the particularity of its working environment will bring greater radiation threat to doctors. Vascular interventional surgery robots can effectively improve the working environment of doctors and can provide more stable operations, improve the success rate of surgery. This study mainly introduces the current research status, key technologies, and future application of vascular interventional surgical robots.
Subject(s)
Robotics , Vascular Surgical Procedures/methods , Heart , TechnologyABSTRACT
Objective To study the feasibility of domestic single-port surgical robot assisted endoscopic system for partial nephrectomy,and analyze its safety in clinical partial nephrectomy based on experimental results Methods Three qualified experimental pigs were selected,two senior urological professors and a senior resident doctor used a domestic single-port surgical robot to perform partial nephrectomy on the left and right kidneys.Recorded the operation duration,hot ischemia duration,suture time,estimated blood loss,volume of renal parenchyma excision and other information.Results There were 8 wedge resection and 4 heminephrectomies.The kidney volume of wedge resection was(7.35±0.81)mL and the blood loss was(8.50±11.09)mL.The total operation time was(41.67±8.50)min,and the time of resection was(5.88±3.27)min and the stitching time was(11.75±2.82)min.The kidney volume of heminephrectomy was(24.30±2.18)mL,and the blood loss was(6.25±4.35)mL.The total operation time of heminephrectomy was(47.00±11.27)min,and the time of resection was(3.25±1.5)min and the stitching time was(10.00±5.25)min.No bleeding was observed on the wound after the Bull dog was released in all operations.There was no significant difference in operation time and blood loss between the heminephrectomy group and the wedge resection group.There was no significant difference in operation time or blood loss between the senior doctor group and the senior resident doctor group.The NASA-TLX scale was used to assess the degree of workload of the operator during surgical operations,and the results showed that none of the three surgeons had a high level of frustration.There were no adverse events related to the single-port surgical robot system during the operation.Conclusion It is safe and feasible for a domestic single-port surgical robot system to perform a partial nephrectomy.
ABSTRACT
OBJECTIVE@#To review the application and research progress of artificial intelligence (AI) technology in trauma treatment.@*METHODS@#The recent research literature on the application of AI and related technologies in trauma treatment was reviewed and summarized in terms of prehospital assistance, in-hospital emergency care, and post-traumatic stress disorder risk regression prediction, meanwhile, the development trend of AI technology in trauma treatment were outlooked.@*RESULTS@#The AI technology can rapidly analyze and manage large amount of clinical data to help doctors identify patients' situation of trauma and predict the risk of possible complications more accurately. The application of AI technology in surgical assistance and robotic operations can achieve precise surgical plan and treatment, reduce surgical risks, and shorten the operation time, so as to improve the efficiency and long-term effectiveness of the trauma treatment.@*CONCLUSION@#There is a promising future for the application of AI technology in the trauma treatment. However, it is still in the stage of exploration and development, and there are many difficulties of historical data bias, application condition limitations, as well as ethical and moral issues need to be solved.
Subject(s)
Humans , Artificial Intelligence , Operative Time , Robotic Surgical Procedures , TechnologyABSTRACT
OBJECTIVES@#Surgical robot system has broken the limitation of traditional surgery and shown excellent performance in surgery, and has been widely used in minimally invasive treatment in most areas of surgery. This study aims to verify the basic performance of the domestic surgical robot system and the safety and effectiveness of the integrated bipolar electrocoagulation and ultrasonic knife.@*METHODS@#The basic performance of the domestic surgical robot system was evaluated by completing the square knot and surgical knot, vertical and horizontal perforation and right ring perforation and suture, as well as picking up beans. Compared with laparoscopy, the safety and effectiveness of the domestic surgical robot after integrated interconnection bipolar electrocoagulation and ultrasonic scalpel were evaluated by detecting the vascular closure performance and the degree of histopathological damage in animals.@*RESULTS@#Compared with freehand knotting, domestic robot knotting speed and circumference were slightly worse, but better than laparoscopic knotting. There was no statistical significance in the tension difference of the surgical knots among the 3 methods (P>0.05), but the tension of the square knots made by the freehand and the domestic surgical robot was greater than that of the laparoscopy (P<0.05). The space required for both the left and right forceps heads of knots was smaller than that of laparoscopy (P<0.001), which successfully completed the 4 quadrant suture tasks, and the time of picking up beans was significantly less than that of laparoscopy (P<0.05). There was no significant difference in the temperature of the liver tissue after the bipolar electrocoagulation between the interconnected domestic surgical robot and the laparoscopy (P>0.05), and the acute thermal injury was observed under the light microscope. The temperature of the liver tissue treated by the domestic robotic ultrasound knife was higher than that of the laparoscopic ultrasound knife (P<0.05).@*CONCLUSIONS@#Domestic surgical robots are obviously superior to laparoscopy in suturing, knotting, and moving objects, and domestic surgical robots' interconnect bipolar electrocoagulation and ultrasonic knife have achieved success in animal experiments, and hemostasis is considered to be safe and effective.
Subject(s)
Animals , Robotics , Laparoscopy/methods , UltrasonographyABSTRACT
OBJECTIVES@#Da Vinci robot technology is widely used in clinic,with minimally invasive surgery development. This study aims to explore the possible influence of advanced surgical robotics on the surgery learning curve by comparing the initial clinical learning curves of 2 different surgical techniques: robotic-assisted gastrectomy (RAG) and laparoscopic-assisted gastrectomy (LAG).@*METHODS@#From September 2017 to December 2020, a chief surgeon completed a total of 108 cases of radical gastric cancer from the initial stage, including 27 cases of RAG of the Da Vinci Si robotic system (RAG group) and 81 cases of LAG (LAG group). The lymph node of gastric cancer implemented by the Japanese treatment guidelines of gastric cancer. The surgical results, postoperative complications, oncology results and learning curve were analyzed.@*RESULTS@#There was no significant difference in general data, tumor size, pathological grade and clinical stage between the 2 groups (P>0.05). The incidence of serious complications in the RAG group was lower than the LAG group (P=0.003). The intraoperative blood loss in the RAG group was lower than that in the LAG group (P=0.046). The number of lymph nodes cleaned in the RAG group was more (P=0.003), among which there was obvious advantage in lymph node cleaning in the No.9 group (P=0.038) and 11p group (P=0.015). The operation time of the RAG group was significantly longer than the LAG group (P=0.015). The analysis of learning curve found that the cumulative sum analysis (CUSUM) value of the RAG group decreased from the 10th case, while the CUSUM of the LAG group decreased from the 28th case. The learning curve of the RAG group had fewer closing cases than that of the LAG group. The unique design of the surgical robot might help to improve the surgical efficiency and shorten the surgical learning curve.@*CONCLUSIONS@#Advanced robotics helps experienced surgeons quickly learn to master RAG skills. With the help of robotics, RAG are superior to LAG in No.9 and 11p lymph node dissection and surgical trauma reduction. RAG can clear more lymph nodes than LAG, and has better perioperative effect.
Subject(s)
Humans , Robotics , Robotic Surgical Procedures/methods , Learning Curve , Stomach Neoplasms/pathology , Retrospective Studies , Laparoscopy/methods , Lymph Node Excision/methods , Gastrectomy/methods , Treatment OutcomeABSTRACT
Objective:To compair the clinical effect of endoscopic spine surgery with and without assistance of an electromagnetic navigation surgical robot(ENSR) system in the treatment of lumbar disc herniations(LDH).Methods:From March 2021 to December 2021, 73 patients with LDH underwent endoscopic minimally invasive treatment in the Department of Spine Surgery, Limin Hospital of Weihai High District. Thirty-eight patients were treated with endoscopic spine surgery assisted by domestic ENSR system(ENSR group), and 35 patients were treated with endoscopic spine surgery alone(endoscopic group). The patients received follow up regularly by telephone or Wechat. The intraoperative fluoroscopy times, puncture times, upper facet arthroplasty times, operation time, preoperative and postoperative Visual Analogue Scale(VAS), Japanese Orthopaedic Association Scores(JOA), and the MOS item short from health survey(SF-36)were compared between the 2 groups. The early postoperative efficacy was evaluated by modified MacNab criteria at 1 week after surgery. SPSS 26.0 was used to analyse the data. P<0.05 was considered that the difference was statistically significant. Results:The age, gender, body mass index(BMI) and other general data of the 2 groups were basically the same, and there was no statistically significant difference( P>0.05). There was no significant difference in the excellent and good rate of postoperative treatment between ENSR group(97.37%) and endoscopic group(94.29%)( Z=0.90, P>0.05). In terms of operation time, intraoperative fluoroscopy times, puncture times, and plasty times, ENSR group[(67.00±17.00) min, (4±2) times, 1 time, 1 time, respectively] was compared with the endoscopic group[(82.00±16.00] min, (17±6) times, (9±5) times, (5±2) times], and the difference was statistically significant( t=3.87,12.62, 9.87, respectively, P<0.05). There were significant differences in VAS, JOA and SF-36 scores between the 2 groups between before and after surgery( F=106.42, 112.14, 26.88, respectively, P<0.05). There was no significant difference in VAS, JOA and SF-36 scores before and after surgery between the 2 groups( F=0.95, 3.54, 0.97, respectively, P>0.05). Conclusion:The endoscopic spine surgery assisted by the ENSR can achieve satisfactory clinical results and is a safe and effective surgical assistance system. For the endoscopic surgery, assisted by the ENSR has obvious advantages in reducing the times of fluoroscopy, puncture, and facet arthroplasty, and shortening the operation time.
ABSTRACT
To provide accurate information for registration and safety evaluation of surgical robot, the pose repeatability measurement method was proposed. According to the terminal instrument of the master-slave surgical robot (such as high-frequency electric knife, ultrasonic knife), a suitable target ball fixture was designed. The node data at 10%, 50% and 100% rated speed were measured respectively. Through data analysis, the pose repeatability property of the tested samples at different speeds was obtained. It has high applicability and repeatability, and can meet the requirements of data traceability and registration testing.
Subject(s)
Equipment Design , Lasers , Robotic Surgical Procedures , Robotics , Surgery, Computer-AssistedABSTRACT
The high incidence of cardiovascular diseases is a serious threat to human health, and endovascular surgery has become the standard treatment for most interventional cardiovascular diseases. The robotassisted endovascular surgery system further enhances surgeons' ability to perform minimally invasive endovascular procedures in interventional cardiology. This study presents a new robotic technique for coronary intervention from the perspective of clinical application. Aiming at clinical application scenarios, this scheme proposed an intuitive guide wire catheter mechanism design, which accurately and perfectly simulates the doctor's hand movements, realizes the positive and negative direction translation of the guide wire catheter, accurate torque control of the guide wire rotation and locking. The results of animal test showed that the R-OneTM has a high degree of dexterity, accuracy and stability,and meets the clinical needs.
Subject(s)
Animals , Cardiovascular Diseases , Catheterization , Equipment Design , Robotic Surgical Procedures , RoboticsABSTRACT
Laparoscopic surgery is a revolution in the fields of surgery in the 21st century. The concept of minimally invasive surgery has been widely accepted. Nowadays, the commercial robot-assisted laparoscopic instrument operating system, commonly known as "surgical robot", does not yet have the attributes of a real robot and still needs further optimization. We are still far from claiming that we are in the "surgical robot era". A new generation of surgical robots with more developed artificial intelligence and simulation functions are worth working on for. "Minimally invasive approach" does not necessarily mean "minimally invasive surgery". The real benefit of patients is the most important indicator for evaluating minimally invasive surgery. The essence of science is discovery but not technological fashion. In the face of rapid technological development, the Chinese surgeons should remain rational and enterprising.
ABSTRACT
With the rapid development of digital technologies represented by artificial intelligence, big data, and cloud computing, the concept of intelligent medicine has emerged. As an in-depth integration of the national strategies of " Healthy China" and " Made in China 2025" , intelligent medicine is widely used in the full-course management of the urological diseases, including disease screening, diagnosis, treatment strategy and follow-up. This article aims to review the application progress and prospects of intelligent medicine in urological diseases and provide references for the urologists.
ABSTRACT
@#Nowadays, the development of the medical instrument industry makes rapid changes in clinical practice. Hybridization of latest technology is playing an increasingly important role in the diagnosis and treatment of disease. Especially, the trend of the integration of three-channel hybrid technology in diagnosis and treatment of early lung cancer has become increasingly obvious. This paper will focus on the technical advance of the three-channel multi- mirror robot and its application in the diagnosis and treatment of early lung cancer.
ABSTRACT
@#Objective To explore the application of Toumai® minimally invasive endoscopic robot in thoracic surgery, and to observe its safety and short-term surgical efficacy. Methods Three patients were enrolled from October to December 2021, including 1 male (69 years) and 2 females (47 years and 22 years). All 3 patients received surgery with Toumai® endoscopic surgical robot, including radical lung cancer surgery in 2 patients and mediastinal tumor resection in 1 patient. Results All 3 patients were successfully operated without conversion to thoracotomy, complication or death. For the male lobectomy patient, the total operation time was 120 min, the intraoperative blood loss was 100 mL, the catheter drainage time was 4 days and the hospital stay time was 5 days. For the female lobectomy patient, the total operation time was 103 min, the intraoperative blood loss was 100 mL, the catheter drainage time was 4 days and the hospital stay time was 5 days. For the female mediastinal tumor patient, the total operation time was 81 min, the intraoperative blood loss was 50 mL, the catheter drainage time was 3 days and the hospital stay time was 3 days. Conclusion The Toumai® minimally invasive endoscopic surgical robot is safe and effective in thoracic surgery. Compared with Da Vinci surgical robot, Toumai® has the same 3D visual field experience and smooth operation.
ABSTRACT
Resumen: La práctica de cirugía robótica es un proceso complejo que implica desarrollo y tecnología no sólo en el campo de la cirugía, sino también en el campo de la anestesiología. Implica un proceso multifactorial, ya que ha generado un cambio drástico multidisciplinario basado en tecnología de punta que pretende ofrecer mejores condiciones durante el manejo perioperatorio en cirugía robótica. La anestesia total intravenosa cumple objetivos específicos en relación a la posición del paciente, relajación cerebral, neuroprotección, hemodinamia, pérdida y recuperación de la conciencia, parálisis neuromuscular, parámetros ventilatorios, etc. Ofrece seguridad y calidad al paciente durante el procedimiento con una mínima interferencia con el monitoreo electrofisiológico y permite modular la profundidad anestésica desde una neurosedación hasta una anestesia general, de acuerdo a las diferentes etapas de la cirugía. Un factor atribuible a la anestesia moderna para el éxito de la cirugía robótica es usar diferentes agentes anestésicos que promuevan inducción, mantenimiento y emersión anestésica más rápida y suave, a fin de reducir el tiempo de recuperación del estado de conciencia, funciones básicas y psicomotoras como la anestesia general multimodal.
Abstract: The practice of robotic surgery is a complex process, involving development and technology; not only in the surgery field but also in the anesthesiology field. It implies a multifactorial process since it has generated a drastic multidisciplinary change based on state-of-the-art technology; which aims to offer better conditions during perioperative management in robotic surgery. Intravenous Total Anesthesia accomplishes specific objectives in relation to patient position, brain relaxation, neuroprotection, hemodynamics, loss and recovery of consciousness, neuromuscular paralysis, ventilatory parameters, providing safety and quality during the procedure; with minimal intervention during electrophysiological monitoring and enabling anesthetic depth to be modulated from neurosedation to general anesthesia, according to the different stages of the surgery. A factor attributable to modern anesthesia for robotic surgery success is to employ different anesthetic agents promoting induction, maintenance of general anesthesia, smother and faster anesthetic emersion, for the purpose of reducing recovery time of the state of consciousness), basic and psychomotor functions; as is the general multimodal anesthesia.