1.
Article in Chinese | WPRIM | ID: wpr-1013487

ABSTRACT

@#Transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) is known as M-TEER. Its strengths include: precise targets and fewer implants; simple and clear principles for catheterization; originating from dependable medical concepts and broad applicability. Furthermore, TEER offers advantages in real-time hemodynamic and effectiveness measurement throughout the procedure over surgical edge-to-edge repair (SEER). When it comes to patients with degenerative mitral regurgitation , M-TEER should aim to deliver more optimum procedural outcomes. In functional mitral regurgitation, a modest transvalvular gradients or moderate residual shunt can be tolerated with M-TEER, which reduces the risk of problems and has no bearing on the patient's prognosis.

2.
Article in Chinese | WPRIM | ID: wpr-1013507

ABSTRACT

@#Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.

3.
Article in Chinese | WPRIM | ID: wpr-1024417

ABSTRACT

Objective To establish a method for testing isolated mitral valve in vitro and quantitatively evaluate the effect of transcatheter edge-to-edge repair technology(TEER)on functional mitral regurgitation(FMR)(non-A2-P2 regurgitation).Methods In this study,an FMR(non-A2-P2 regurgitation)model was developed by dilating the annulus orifice and displacing the papillary muscle in isolated porcine mitral valve.The hydrodynamics characteristics of 6 valves were tested by a pulsatile flow testing system under different physiological and pathological conditions before and after TEER.Results The results show that the valve regurgitation improved from moderate-severe[regurgitant fraction(60.2±17.5)%]to mild-moderate[regurgitant fraction(34.7±12.0)%]by repair(P<0.001).The EOA[(3.8±1.6)cm2 vs.(2.2±0.5)cm2,P<0.001]and the forward cross valve pressure difference[(1.8±1.3)mmHg vs.(3.8± 1.8)mmHg,P<0.001],which characterize the forward flow performance of the valve,were compared before and after repair,and the differences were statistically significant.At the same time,the repair caused valve stenosis(the effective orifice area decreased by 40%and the positive differential pressure increased by 110%),but the valves was still within the normal physiological range,and no iatrogenic stenosis was caused.Conclusions It can be seen that TEER has an effect on FMR.This study provides validation and evaluation methods in vitro for expanding indications and improving TEER,and reference for developing standards of transcatheter valve repair testing in vitro.

4.
Article in Chinese | WPRIM | ID: wpr-992805

ABSTRACT

Objective:To investigate short-term safety, efficacy and the learning curve of this self-developed novel transcatheter valve repair system (Neonova?) in patients with mitral regurgitation, and explore the role of perioperative echocardiography.Methods:Ten patients who visited the Union Hospital of Tongji Medical College, Huazhong University of Science and Technology from June 2021 to March 2022 and met the inclusive criteria were prospectively enrolled. All the patients were at high risk of surgery with moderate to severe or severe mitral regurgitation (MR). Clamps of Neonova? were implanted under guidance of transesophageal echocardiography and digital subtraction angiography. Clinical outcomes, echocardiography indexes and learning curves of this technique were evaluated immediately after intervention, 7 d, 1 month and 3 months post-intervention.Results:The technical success rate was 100% with MR relieved in all patients immediately after intervention. The device and procedural success rates were both 90.0% with 1 patient received surgical replacement at 37 days post-intervention while the others′ reduced to mild (8/9) and moderate (1/9) MR. New York Heart Association class and the Kansas City Cardiomyopathy Questionnaire improved significantly (all P<0.001). Mean mitral valve pressure gradient didn′t increase significantly after intervention when compared with that before intervention( P=0.324), and no mitral stenosis was observed. Left ventricular end-diastolic diameter decreased significantly ( P=0.008) during follow up.Procedure duration ranged from 60 to 300 (175.8±75.2)minutes. The simple linear regression model between procedure volume and duration showed that procedure duration decreased significantly with the increase of procedure volume ( F=15.857, P=0.004). Conclusions:Neonova? implantation can improve MR severity and clinical symptoms safely and effectively. Transthoracic echocardiography and transesophageal echocardiography are essential for perioperative management of transcatheter mitral valve repair.

5.
Article in Chinese | WPRIM | ID: wpr-996621

ABSTRACT

@#Mitral regurgitation is the most common heart valvular disease at present. In the past, mitral regurgitation was mainly treated by surgical mitral valve repair or replacement. However, with the progress of transcatheter interventional techniques and instruments in recent years, transcatheter mitral valve interventional therapy has gradually shown its advantages and benefited patients. The purpose of this article is to review the progress of transcatheter mitral valve intervention in this year, and to provide prospects for the future of transcatheter mitral valve treatment.

6.
Article in Chinese | WPRIM | ID: wpr-924683

ABSTRACT

@#Objective    To investigate the early clinical results of MitraClip system in domestic patients. Methods     We retrospectively analyzed the clinical data of 36 patients who underwent transcatheter edge-to-edge repair procedure using MitraClip system in Beijing Fuwai Hospital, Shenzhen Fuwai Hospital and Fuwai Yunnan Cardiovascular Hospital between January and June 2021. There were 24 males and 12 females, with a median age of 70 (47-86) years. Ten (27.8%) patients had 3+ mitral regurgitation (MR) and 26 (72.2%) patients had 4+ MR preoperatively. Results    All procedures were successfully performed. The reduction in MR was 2+ at least immediately after surgery, and 91.7% of patients had MR≤2+ at 3 days postoperatively. There was no statistical difference in left ventricular ejection fraction change postoperatively. Forward velocity and peak gradient of mitral valve were increased after the procedure. Mean gradient of mitral valve were increased at 3 days postoperatively than immediately after surgery (P<0.001). Two patients had acute pericardial effusion intraoperatively, and received pericardial puncture and drainage immediately. Conclusion    MitraClip system has been applied well in domestic patients and can significantly improve MR. This sutdy has a good consistency with foreign studies, and the early results are satisfactory.

7.
Article in Chinese | WPRIM | ID: wpr-906570

ABSTRACT

@#Transcatheter edge-to-edge repair (TEER) originated from surgical edge-to-edge repair. MitraClip is the first mature TEER device, and the TEER based on MitraClip is far ahead of many transcatheter mitral valve repair (TMVr) technologies in terms of safety, effectiveness and popularity, so it is named separately in the latest guidelines. The TEER has the following advantages: consistent with basic medical principles, few implants, precise target, less invasive and repeatable. However, there are also some shortcomings, such as the relatively complex design of transfemoral device, target single and relatively narrow indications. At present, the main clinical data of TEER are mainly from the clinical practice of MitraClip. Based on the three-year outcomes of COAPT study, both 2020 ACC/AHA guideline and 2020 ACC expert consensus decision pathway on the management of mitral regurgitation recommend in patients with chronic heart failure with left ventricular dysfunction and severe mitral regurgitation in nonresponders to medicine treatment. Edward's PASCAL, another TEER device, has two models. Among the domestic TEER devices, the ValveClamp of Hanyu medical technology has many distinct advantages, such as simple operation, large clamping area, high clamping efficiency and no need of X-ray. DragonFly, another domestic TEER device, has also completed its feasibility study. There are five trends of TEER in the future: further expansion of indications, combination with other interventional techniques, repeatable operations, transcatheter mitral valve replacement after TEER, and continuous improvement and innovation of equipment.