ABSTRACT
ABSTRACT Purpose: To determine the clinical outcomes in patients after type 1 Boston keratoprosthesis surgery and the significance of ultrasound biomicroscopy imaging for postoperative follow-up. Methods: This retrospective analysis included 20 eyes of 19 patients who underwent corneal transplantation with type 1 Boston keratoprosthesis between April 2014 and December 2021. Data on patient demographics, preoperative diagnosis, visual acuity, and postoperative clinical findings were analyzed. Results: Type 1 Boston keratoprosthesis implantation resulted in intermediate- and long-term positive outcomes. However, blindness and other serious complications such as glaucoma, retroprosthetic membrane formation, endophthalmitis, or retinal detachment also occurred. The use of ultrasound biomicroscopy imaging allowed for better evaluation of the back of the titanium plate, anterior segment structures, and the relationship of the prosthesis with surrounding tissues, which provided valuable postoperative information. Conclusion: Regular lifetime monitoring and treatment are necessary in patients who undergo Boston type 1 keratoprosthesis implantation for high-risk corneal transplantation. ultrasound biomicroscopy imaging can be a valuable imaging technique for the evaluation of patients with Boston type 1 keratoprosthesis, providing important information on anterior segment anatomy and potential complications. Further studies and consensus on postoperative follow-up protocols are required to optimize the management of patients with Boston type 1 keratoprosthesis.
ABSTRACT
Objetivo: Describir los hallazgos imagenológicos en radiografías de tórax y ecografías pulmonares de pacientes con síndrome post-COVID-19. Métodos: estudio descriptivo, prospectivo y transversal que incluyó pacientes con síndrome post-COVID-19, sometidos a radiografías de tórax y ecografías pulmonares en el Servicio de Neumonología Clínica del Hospital Dr. José Ignacio Baldo, entre enero y octubre de 2022, con la finalidad de establecer su evolución imagenológica pulmonar. Se utilizó estadística descriptiva, chi-cuadrado de Pearson y prueba kappa de concordancia, considerando significativo un valor de p < 0,05. Resultados: La muestra consistió en 58 pacientes con una edad media de 55 ± 13 años, predominando el sexo femenino (58,6%). El 60,3% mostró alteraciones en la radiografía de tórax; un 74,3% con patrón intersticial bilateral y un 25,7% con patrón intersticial unilateral. La ecografía reveló patrón intersticial en el 43,1% de los casos y se observaron dos microconsolidaciones subpleurales. Conclusiones: Las radiografías de tórax y las ecografías pulmonares son herramientas imagenológicas eficaces, accesibles y económicas para detectar alteraciones en pacientes con síndrome post-COVID-19. (AU)
Objective: To describe imaging findings in chest radiographs and lung ultrasounds of patients with post-COVID-19 syndrome. Methods: A descriptive, prospective, and cross-sectional study was carried out that included patients with post-COVID-19 syndrome, who underwent chest radiographs and lung ultrasounds at the Clinical Pneumonology Service of Dr. José Ignacio Baldo Hospital, between January and October 2022. Descriptive statistics, Pearson's chi-square, and kappa concordance test were used, considering a p-value < 0.05 significant. Results: The sample consisted of 58 patients with an average age of 55 ± 13 years, with a predominance of females (58.6%). 60.3% showed alterations in the chest radiograph; 74.3% with a bilateral interstitial pattern and 25.7% with a unilateral interstitial pattern. The ultrasound revealed an interstitial pattern in 43.1% of the cases and two subpleural microconsolidations were observed. Conclusions: Chest radiographs and lung ultrasounds are effective, accessible, and economical imaging tools to detect alterations in patients with post-COVID-19 syndrome. (AU)
Subject(s)
Humans , Male , Female , Adult , Middle Aged , Radiography, Thoracic , COVID-19/diagnosis , Post-Acute COVID-19 Syndrome/drug therapy , Pneumonia/pathology , Quality of Life , Prospective Studies , Lung Diseases, Interstitial/drug therapyABSTRACT
Objetivo: Identificar y clasificar las diferentes anomalías del desarrollo diagnosticadas en la unidad de ecografía del servicio de medicina materno fetal de la Maternidad Concepción Palacios entre enero y diciembre de 2023. Métodos: Estudio retrospectivo, descriptivo, transversal que incluyó la evaluación de los 4225 reportes de ultrasonido obstétrico realizados en 2023. Se excluyeron los estudios sin diagnóstico morfológico. Las variables evaluadas fueron características clínicas de las gestantes, prevalencia según tipo de anomalía del desarrollo y según el aparato o sistema afectado. Resultados: Se diagnosticaron anomalías del desarrollo en 282 pacientes, para una frecuencia de 6,7 %. Las anomalías fueron únicas en 187 casos (66,3 %) y múltiples en 95 pacientes (33,7 %). El total de malformaciones fue 360 (8,5 %). El mínimo de lesiones detectadas fue una y el máximo fue tres. El sistema afectado con mayor frecuencia fue el sistema nervioso central, con 104 casos (28,9 %); le siguen, en orden de frecuencia, los marcadores aislados, vistos en 92 pacientes (25,6 %) y las anomalías cardiovasculares, en 49 fetos (13,6 %). Conclusión: La frecuencia de malformaciones congénitas diagnosticadas en el año 2023 fue de 6,7 % de las ecografías realizadas en la unidad de ecografía del servicio de medicina materno fetal de la Maternidad Concepción Palacios; en las dos terceras partes de los casos fueron únicas y el tercio restante fueron múltiples. En orden de frecuencia, los sistemas afectados fueron sistema nervioso central, marcadores aislados de aneuploidías y anomalías cardiovasculares(AU)
Objective: To identify and classify the different developmental anomalies diagnosed in the ultrasound unit of the maternal-fetal medicine service of the Concepción Palacios Maternity Hospital between January and December 2023. Methods: Retrospective, descriptive, cross-sectional study that included the evaluation of the 4225 obstetric ultrasound reports performed in 2023. Studies without morphological diagnosis were excluded. The variables evaluated were clinical characteristics of the pregnant women, prevalence according to type of developmental anomaly and according to the affected apparatus or system. Results: Developmental abnormalities were diagnosed in 282 patients, with a frequency of 6.7%. The anomalies were single in 187 cases (66.3%) and multiple in 95 patients (33.7%). The total number of malformations was 360 (8.5%). The minimum number of injuries detected was one and the maximum was three. The most frequently affected system was the central nervous system, with 104 cases (28.9%); This is followed by isolated markers, seen in 92 patients (25.6%), and cardiovascular anomalies, in 49 fetuses (13.6%). Conclusion: The frequency of congenital malformations diagnosed in 2023 was 6.7% of the ultrasound scans performed in the ultrasound unit of the maternal-fetal medicine service of the Concepción Palacios Maternity Hospital; Two-thirds of the cases were singles and the remaining third were multiples. In order of frequency, the affected systems were central nervous system, isolated markers of aneuploidies, and cardiac anomalies(AU)
Subject(s)
Humans , Female , Pregnancy , Adolescent , Adult , Middle Aged , Perinatology , Prenatal Diagnosis , Congenital Abnormalities , Parenting , Ultrasonics , Central Nervous System , Ultrasonography , Pregnant Women , Fetus , Hospitals, MaternityABSTRACT
RESUMEN Antecedentes: el tratamiento del carcinoma diferenciado de tiroides (CDT) de bajo riesgo es aún motivo de discusión. En las últimas décadas se observó una migración hacia tratamientos personalizados acordes con las características de cada paciente y de cada tumor. Las guías de práctica vigentes habilitan la lobectomía en pacientes seleccionados, con bajo riesgo de recurrencia. Objetivo: describir los resultados en una cohorte de pacientes con CDT de bajo riesgo de recurrencia tratados con lobectomía tiroidea. Material y métodos: estudio observacional descriptivo de una revisión retrospectiva de historias clínicas de 114 pacientes con CDT tratados con lobectomía tiroidea entre enero de 2015 y abril de 2023. Resultados: fueron operados 114 pacientes, con media de edad de 44 años ± 12; 90 (79%) fueron mujeres. La mediana del tamaño tumoral fue de 9,4 mm, RIC (rango intercuartílico 25-75% 7-13 mm), y 103 de los nódulos (90%) fueron ecográficamente sólidos. Solo 2 pacientes con invasión vascular mayor de 4 vasos requirieron completar la tiroidectomía total. No se registraron complicaciones de importancia, salvo una parálisis recurrencial transitoria. Con un seguimiento promedio de 33,4 meses, no se observaron recurrencias locorregionales ni a distancia en la población analizada. Conclusión: la lobectomía tiroidea en el tratamiento del CDT de bajo riesgo tuvo una baja morbilidad sin recurrencias en la serie presentada. La selección rigurosa de los pacientes y la interacción de un equipo multidisciplinario se consideran esenciales para la implementación exitosa de esta metodología terapéutica.
ABSTRACT Background: The treatment of low-risk differentiated thyroid cancer (DTC) is still a matter of debate. Over the past few decades, there has been a shift towards a more personalized approach, tailored to the individual risks of each patient and tumor. The current practice guidelines recommend lobectomy in selected patients, with low risk of recurrence. Objective: To describe the results of thyroid lobectomy in a cohort of patients with DTC with low risk of recurrence. Material and methods: We conducted a descriptive and observational study. The medical records of patients with DTC who underwent thyroid lobectomy between January 2015 and April 2023 were retrospectively reviewed. Results: A total of 114 patients were operated on; mean age was 44 ± 12 years and 90 (79%) were women. The median tumor size was 9.4 mm (IQR 25-75% 7-13 mm), and 103 nodules (90%) were solid on ultrasound. Only 2 patients with vascular invasion involving > 4 vessels required completion thyroidectomy. There were no major complications and only one patient developed temporary recurrent laryngeal palsy. There were no locoregional or distant recurrences during mean follow-up of 33.4 months. Conclusion: Thyroid lobectomy for low-risk DTC had low morbidity and no recurrences in the series presented. The rigorous selection of patients and the interaction of a multidisciplinary team are considered essential for the successful implementation of this therapeutic approach.
ABSTRACT
Introducción: El Síndrome de Sjögren primario es una enfermedad autoinmune que se caracteriza por un proceso inflamatorio que afecta fundamentalmente a las glándulas exocrinas. Existe un interés creciente en el uso de la ecografía de glándulas salivales como una herramienta no invasiva para el diagnóstico del Síndrome de Sjögren primario (SSp). Objetivo: Describir los hallazgos ecográficos de glándulas salivales y de biopsia glandular en pacientes con sospecha de Síndrome de Sjögren primario. Materiales y métodos: Se realizó un estudio observacional de corte transversal en el que se incluyó a pacientes adultos con sospecha de SSp. En todos los casos se realizó ecografía y biopsia de glándulas salivales. Se registraron variables epidemiológicas, clínicas, de imagen (i.e. ultrasonido) y el resultado anatomopatológico de las biopsias de glándulas salivales. Se realizó un análisis descriptivo de las variables. Resultados: Se incluyeron a 23 pacientes con sospecha de SSp. La edad promedio de los pacientes fue 47,7±11,1 años, y el 96,0% fueron de sexo femenino. En todas las ecografías se constataron hallazgos compatibles con SSp, mientras que en el 96% de las biopsitas se objetivaron datos compatibles con SSp. Conclusión: En esta serie de pacientes, se pudo constatar un alto porcentaje de casos en los que se objetivó cambios compatibles con SSp, tanto en la ecografía de glándulas salivales como en la anatomía patológica.
Introduction : Primary Sjögren's Syndrome is anautoimmune disease that is characterized by an inflammatory process that primarily affects the exocrine glands. There is growing interest in the use of salivary gland ultrasound as a non-invasive tool for the diagnosis of primary Sjögren's Syndrome (pSS). Objective: To describe the ultrasound findings of salivary glands and glandular biopsy in patients with suspected primary Sjögren's Syndrome. Materials and methods: A cross-sectional observational study including adult patients with suspected pSS . In all cases, ultrasound and salivary gland biopsy were performed. Epidemiological, clinical, imaging (i.e. ultrasound) variables as well as pathology results of salivary gland biopsies were recorded. A descriptive analysis of the variables was carried out. Results: 23 patients with suspected pSS were included. The average age of the patients was 47.7±11.1 years, and 96.0% were female. All ultrasounds showed findings compatible with pSS, while 96% of the biopsies reported results compatible with pSS. Conclusion: In this group of patients, a high percentage of cases showed data compatible with pSS, both in the ultrasound and biopsy of the salivary glands.
ABSTRACT
SUMMARY: The aim of this study was to compare the clinical value of vertebral artery ultrasound (VAU), Magnetic Resonance Angiography (MRA) and Digital Subtraction Angiography (DSA) on vertebral artery stenosis in patients with posterior circulation ischemia. Seventy-three patients with posterior circulation ischemia underwent vertebral artery ultrasound and magnetic resonance angiography as well as digital subtraction angiography, and the diagnosis of vertebral artery stenosis (VAS) and the degree of stenosis (normal, mild stenosis, moderate stenosis, severe stenosis, and occlusion) were recorded and compared between digital subtraction angiogram and vertebral artery ultrasound and magnetic resonance angiography. The vertebral artery stenosis rates on digital subtraction angiography and vertebral artery ultrasound were 87.30 % (55/63) and 49.20 % (31/63), respectively, and the difference was statistically significant. The rates of vertebral artery stenosis on digital subtraction angiography and, magnetic resonance angiography was 90.38 % (47/52) and 88.46 % (46/ 52), respectively, and the differences was not statistically significant. The sensitivity, accuracy, negative predictive value, and positive predictive value of vertebral artery ultrasound in diagnosing vertebral artery stenosis were 51.35 %, 54.76 %, 18.18 %, and 95.00 %, respectively, lower than those of magnetic resonance angiography, which were 91.89 %, 90.48 %, 57.14 %, and 97.14 %, respectively. Of the noninvasive imaging techniques, vertebral artery ultrasound does not accurately characterize vertebral artery stenosis and its degree of stenosis. Magnetic resonance angiography effectively screens for vertebral artery stenosis and its degree of stenosis, and can be used as a reliable tool for vertebral artery stenosis in posterior circulation cerebral infarction, and can be used in conjunction with digital subtraction angiogram in order to improve diagnostic convenience and accuracy.
El objetivo de este estudio fue comparar el valor clínico de la ecografía de la arteria vertebral (VAU), la angiografía por resonancia magnética (ARM) y la angiografía por sustracción digital (DSA) en la estenosis de la arteria vertebral en pacientes con isquemia de la circulación posterior. A 73 pacientes con isquemia de la circulación posterior se les realizó una ecografía de la arteria vertebral y una angiografía por resonancia magnética, así como una angiografía por sustracción digital, y se les diagnosticó estenosis de la arteria vertebral (EVA) y el grado de estenosis (normal, estenosis leve, estenosis moderada, estenosis grave, y oclusión) se registraron y compararon la angiografía por sustracción digital y la ecografía de la arteria vertebral y la angiografía por resonancia magnética. Las tasas de estenosis de la arteria vertebral en la angiografía por sustracción digital y la ecografía de la arteria vertebral fueron del 87,30 % (55/63) y del 49,20 % (31/63), respectivamente, y la diferencia fue estadísticamente significativa. Las tasas de estenosis de la arteria vertebral en la angiografía por sustracción digital y la angiografía por resonancia magnética fueron del 90,38 % (47/52) y del 88,46 % (46/52), respectivamente, y las diferencias no fueron estadísticamente significativas. La sensibilidad, precisión, valor predictivo negativo y valor predictivo positivo de la ecografía de la arteria vertebral en el diagnóstico de estenosis de la arteria vertebral fueron 51,35 %, 54,76 %, 18,18 % y 95,00 %, respectivamente, inferiores a los de la angiografía por resonancia magnética, que fueron 91,89 %, 90,48 %, 57,14 % y 97,14 %, respectivamente. De las técnicas de imagen no invasivas, la ecografía de la arteria vertebral no caracteriza con precisión la estenosis de la arteria vertebral y su grado de estenosis. La angiografía por resonancia magnética detecta eficazmente la estenosis de la arteria vertebral y su grado de estenosis, y puede usarse como una herramienta confiable para la estenosis de la arteria vertebral en el infarto cerebral de circulación posterior, y puede ser utilizada junto con la angiografía por sustracción digital para mejorar el diagnóstico y la exactitud.
Subject(s)
Humans , Male , Female , Middle Aged , Aged , Vertebrobasilar Insufficiency/diagnostic imaging , Angiography, Digital Subtraction , Ultrasonography , Magnetic Resonance Angiography , Predictive Value of Tests , Sensitivity and SpecificityABSTRACT
INTRODUCTION: Chronic neck pain (CNP) is a common musculoskeletal problem that affects a large proportion of the population and lasts longer than three months. It has a high cost in terms of life, disability, and healthcare. Several modalities have effectively provided immediate and long-term relief for CNP; however, the comparative clinical effectiveness of these modalities is limited. OBJECTIVES: The study aimed to determine the clinical effectiveness of Class IV Laser therapy and Therapeutic Ultrasound (TUS) in patients with CNP. METHODS AND MATERIALS: Forty-four patients with CNP of both genders were recruited from an age range of 2045 years from the Department of Musculoskeletal Physiotherapy of Maharishi Markandeshwar Institute of Physiotherapy, MM(DU), Ambala, India. They were divided into two groups at random: the LASER group A (n = 22) and the TUS group B (n = 22). The intervention duration was 2 weeks with 6 treatment sessions. Pre- and post-treatment outcome measures were assessed with the Visual Analog Scale (VAS), Algometer, Goniometer, and Neck Disability Index (NDI) questionnaires at baseline and after 2 weeks of intervention. The LASER group received a target dose of 10 joules per cm2 at a power of 10 watts, with a continuous dosage frequency. The TUS group underwent a continuous mode ultrasound (3 MHz, 1 W/cm2) for 6 minutes. The Shapiro-Wilk test was used to assess the normality of the data. For parametric and non-parametric data analysis within the group, the paired t-test and Wilcoxon signed rank were used. The independente t-test and Mann-U Whitney test were used for the group comparison of parametric and non-parametric data, respectively. RESULTS: In both groups, there was a significant improvement in all the outcome measures (p<0.001). There was a statistically significant difference between the two interventions in VAS, Pain Pressure Threshold (PPT), and NDI (p<0.05). CONCLUSION: Class IV Laser therapy is clinically more effective than therapeutic ultrasound in treating patients with chronic neck pain.
INTRODUÇÃO: A dor cervical crônica (DCC) é um problema musculoesquelético comum que afeta uma grande proporção da população e dura mais de três meses. Ela tem um alto custo em termos de vida, incapacidade e assistência médica. Várias modalidades têm proporcionado alívio imediato e de longo prazo para a dor cervical crônica; entretanto, a eficácia clínica comparativa dessas modalidades é limitada. OBJETIVOS: O objetivo do estudo foi determinar a eficácia clínica da terapia a laser de classe IV e do ultrassom terapêutico (UST) em pacientes com DCC. MÉTODOS E MATERIAIS: Quarenta e quatro pacientes com DCC de ambos os sexos, em uma faixa etária de 20 a 45 anos, foram recrutados do Departamento de fisioterapia musculoesquelética do Instituto de Fisioterapia Maharishi Markandeshwar, MM (DU), Ambala, Índia. Eles foram divididos em dois grupos de forma aleatória: o grupo LASER A (n = 22) e o grupo UST B (n = 22). A duração da intervenção foi de 2 semanas com 6 sessões de tratamento. As medidas de resultado pré e pós-tratamento foram avaliadas com os questionários Escala Visual Analógica (EVA), Algometer, Goniometer e Índice de Incapacidade do Pescoço (IIP) na linha de base e após 2 semanas de intervenção. O grupo LASER recebeu dose alvo de 10 joules por cm2 na potência de 10 watts, com frequência de dosagem contínua. O grupo UST foi submetido a ultrassom em modo contínuo (3 MHz, 1 W/cm2) por 6 minutos. O teste de Shapiro-Wilk foi utilizado para avaliar a normalidade dos dados. Para análise dos dados paramétricos e não paramétricos dentro do grupo, foram utilizados o teste t pareado e o posto sinalizado de Wilcoxon. O teste t independente e o teste Mann-U Whitney foram utilizados para comparação de grupos para dados paramétricos e não paramétricos, respectivamente. RESULTADOS: Em ambos os grupos, houve uma melhora significativa em todas as medidas de resultado (p<0,001). Houve uma diferença estatisticamente significativa entre as duas intervenções na EVA, Limiar de pressão de dor (PPT) e IIP (p<0,05). CONCLUSÕES: A terapia a laser de classe IV é clinicamente mais eficaz do que o ultrassom terapêutico no tratamento de pacientes com dor cervical crônica.
Subject(s)
Neck Pain , Laser Therapy , Chronic PainABSTRACT
Expanding uterine masses can be the cause of pregnancy loss and add technical difficulties to uterus evacuation due to the intense anatomical distortion of the endocervical canal and uterine cavity. The literature is scarce in the peculiarities of the management of missed abortions in uterus with important distorted anatomies. We report a case of a primigravida patient who presented a rapid and expressive increase of abdominal volume due to a giant uterine mass, evolving to miscarriage. Ultrasound can be a useful tool, allowing visualization of the endocervical path and uterine cavity, helping to perform uterine evacuation in the presence of anatomical distortion without compromising the reproductive future. To the best of our knowledge, no such case has been previously reported.
ABSTRACT
Introducción. La hipertensión portal (HTP) se define como una elevación anormal de la presión venosa en el sistema portal que lleva al desarrollo de vías colaterales para desviar el flujo sanguíneo de la zona. Dentro de su etiología están las relacionadas con la cirrosis hepática y otras causas denominadas no cirróticas. El objetivo de este estudio fue evaluar los principales hallazgos demográficos, clínicos y paraclínicos en un grupo de pacientes con HTP, y determinar el uso de ayudas invasivas y no invasivas, y su disponibilidad para el diagnóstico y seguimiento de los pacientes en los centros que no cuentan con laboratorio de hemodinamia hepática, reflejando la dinámica de múltiples escenarios en Colombia. Metodología. Se realizó un estudio descriptivo de corte transversal, retrospectivo, en pacientes atendidos en una institución de tercer nivel del sur de Colombia, entre enero del año 2015 y diciembre del año 2020. Resultados. Se obtuvo una muestra de 61 pacientes en donde la mayoría de casos correspondían a hombres en la séptima década de la vida, procedentes del área urbana. La principal causa de consulta fue el sangrado digestivo (39,3 %), asociado a la presencia de telangiectasias (arañas vasculares) en el 37,2 %, seguido de circulación colateral (31,3 %) e ictericia (19,7 %). En la ecografía abdominal (realizada en el 57,4 % de los pacientes) predominaron la cirrosis (68 %) y la presencia de esplenomegalia (14,2 %), y en lospacientes con Doppler portal (realizado en el 16,4 %) se encontró hígado cirrótico (80 %) y dilatación portal (40 %). Con respecto a los hallazgos en la esofagogastroduodenoscopia predominó la presencia de várices esofágicas y gastritis crónica. Conclusión. El principal motivo de consulta fue el sangrado digestivo, en tanto que la cirrosis fue el antecedente y el hallazgo imagenológico más frecuente, seguido de las várices esofágicas. Se encontró que el uso de paraclínicos, ecografía abdominal, ecografía con Doppler portal y esofagogastroduodenoscopia fueron los más utilizados en el contexto clínico de los pacientes con el diagnóstico de HTP.
Introduction. Portal hypertension (PHT) is defined as an abnormal elevation of venous pressure in the portal system that leads to the development of collateral pathways to divert blood flow from the area. Within its etiology are those related to liver cirrhosis and other so-called non cirrhotic causes. The aim of this study was to evaluate the main demographic, clinical and paraclinical findings in a group of patients with PHT, and to determine the use of invasive and non-invasive aids, and their availability for the diagnosis and follow-up of patients in centers that do not have a hepatic hemodynamics laboratory, reflecting the dynamics of multiple scenarios in Colombia. Methodology. A descriptive, retrospective, cross-sectional, retrospective study was conducted in patients attended in a third level institution in Southern Colombia, between January 2015 and December 2020. Results. A sample of 61 patients was obtained where the majority of cases corresponded to men in the seventh decade of life, from the urban area. The main cause of consultation was digestive bleeding (39.3%), associated with the presence of telangiectasias (spider veins) in 37.2%, followed by collateral circulation (31.3%) and jaundice (19.7%). In abdominal ultrasound (performed in 57.4% of the patients), cirrhosis (68%) and the presence of splenomegaly (14.2%) predominated, and in patients with portal Doppler (performed in 16.4%), cirrhotic liver (80%) and portal dilatation (40%) were found. With respect to the findings in the esophagogastroduodenoscopy, esophageal varices and chronic gastritis were predominant. Conclusion. The main reason for consultation was gastrointestinal bleeding, while cirrhosis was the most frequent history and imaging finding, followed by esophageal varices. It was found that the use of paraclinics, abdominal ultrasound, ultrasound with portal Doppler and esophagogastroduodenoscopy were the most used in the clinical context of patients diagnosed with PHT.
ABSTRACT
Background@#Hamstring strain injury remains persistently high in sports, highlighting the need for additional investigation of its predisposing variables. Despite hamstring injury being well investigated, there’s a lack of studies on changes in echo intensity and shear wave elastography of hamstrings among athletes with a history of injury, which could be considered modifiable risk variables.@*Objectives@#To examine echo intensity and shear wave elastography characteristics of previously injured hamstrings among athletes, assessing the differences between the injured leg and controls.@*Methods@#This systematic review will focus on studies reporting echo intensity and shear wave elastography characteristics of athletes with a history of hamstring strain injury compared to a control group. The search strategy will locate studies written in English from 1990 to 2023 using four electronic databases: PubMed, EBSCO (CINAHL and Medline), Science Direct, and Web of Science. Studies reporting measures using imaging other than ultrasound and where no diagnosis of hamstring strain has been made will be excluded. Two independent reviewers will screen and critically appraise the studies using the McMasters Critical Review Form. Two reviewers will independently extract relevant data and present a descriptive synthesis. A meta-analysis will be conducted when two or more studies provide data for the same outcome measure.@*Expected Results@#This review can better understand hamstring maladaptation to injury. Utilizing echo-intensity and shear wave elastography as objective outcome measures can inform clinical practice toward developing an effective rehabilitation program for injury prevention.
Subject(s)
Wounds and Injuries , Sports , RehabilitationABSTRACT
OBJECTIVES@#To compare the clinical effect on Bell's facial palsy in the acute stage between the staging comprehensive treatment with acupuncture-moxibustion and western medication.@*METHODS@#Sixty patients with Bell's facial palsy in the acute stage were randomly divided into an observation group and a control group, with 30 cases in each one. The patients in the control group were administered orally with prednisone acetate tablets and methylcobalamin tablets until the 28th day of illness. In the observation group, the staging comprehensive treatment with acupuncture-moxibustion was adopted. On the affected side, Qianzheng (EX-HN 16), Yifeng (TE 17), Sibai (ST 2), Yangbai (GB 14), Jiache (ST 6), Dicang (ST 4) and Touwei (ST 8), etc. were stimulated. In the acute stage (Day 1 to 7 of illness), the routine acupuncture and the point-toward-point needle insertion were delivered, no any manipulation was exerted at acupoints, and the needles were retained for 30 min. In the subacute stage (Day 8 to 14 of illness), on the base of the treatment as the acute stage, the depth of needle insertion was adjusted at a part of acupoints and the even needling technique was operated by twisting needle. Besides, electroacupuncture (EA) was attached to Qianzheng (EX-HN 16) and Dicang (ST 4), with continuous wave of low intensity and high frequency, 100 Hz, for 20 min. In the recovery stage (Day 15 to 28 of illness), on the base of the treatment as the subacute stage, the heavy stimulation of acupuncture was given, in which, the sticking and lifting needle techniques were delivered after the needles were inserted from Sibai (ST 2) toward Dicang (ST 4), and from Dicang (ST 4) toward Jiache (ST 6), separately; warm needling was operated at Yifeng (TE 17), and EA changed to stimulate the acupoints with the intermittent wave of high intensity and low frequency, 2 Hz, for 30 min. Acupuncture-moxibustion was given once every other day until the end of the 28th day of illness. The level of House-Brackmann facial nerve function rating scale (H-B grade),the score of Sunnybrook facial nerve grading system (Sunnybrook), the score of facial disability index (FDI), the temperature difference in the infrared thermal imaging facial area and electromyogram (EMG) situation of the affected muscle group were observed before and after treatment in the two groups. Using musculoskeletal ultrasound,the facial nerve diameter was detected and the clinical effect was compared between the two groups.@*RESULTS@#After treatment, the level of H-B grade, Sunnybrook score, the scores of physical function and social life function in FDI were improved when compared with those before treatment in the patients of either group (P<0.01, P<0.05), and the results of these evaluations in the observation group were better than those of the control group (P<0.05). After treatment, the temperature difference of the frontal area, the eye area, the zygomatic area and the mouth corner was declined in comparison with that before treatment in the two groups (P<0.05), and the temperature difference in each area in the observation group was lower than that of the control group (P<0.05).The root mean square (RMS) of the frontal muscle group, the zygomatic muscle group and the orbicularis muscle group on the affected side increased in comparison with that before treatment in the two groups (P<0.01), and RMS of the observation group was higher than that of the control group (P<0.05) after treatment. Before treatment, the diameter of the facial nerve on the affected side was larger than that on the healthy side (P<0.01), and after treatment, the diameter on the affected side was reduced when compared with that before treatment in the two groups (P<0.01); the diameter of the facial nerve on the affected side in the observation group was smaller than that of the control group (P<0.05), while, the diameter on the affected side was larger when compared with the healthy side in the control group (P<0.05). The total effective rate of the observation group was 93.3% (28/30), higher than that of the control group (83.3% [25/30], P<0.05).@*CONCLUSIONS@#The staging comprehensive treatment with acupuncture-moxibustion is clearly effective on Bell's facial palsy in the acute stage, which affirms the effectiveness of acupuncture-moxibustion for the acute stage of Bell's facial palsy in comparison with conventional western medication.
Subject(s)
Humans , Facial Paralysis/therapy , Moxibustion , Acupuncture Therapy , Bell Palsy/therapy , FaceABSTRACT
Bronchopulmonary dysplasia (BPD) is the most common chronic lung disease in preterm infants. Despite significant progress in the understanding of its etiology, mechanisms, prevention, and treatment, the prognosis remains poor. BPD not only has a high mortality rate but also causes persistent respiratory, neurological, and cardiovascular impairments in survivors. The author's team has successfully prevented the occurrence of BPD by managing neonatal lung diseases under lung ultrasound monitoring for nearly 7 years, opening up a new approach in BPD prevention. This article provides a brief overview of the approach, aiming to facilitate further research and provide more scientifically sound management strategies to prevent or minimize the occurrence of BPD.
Subject(s)
Infant, Newborn , Infant , Humans , Bronchopulmonary Dysplasia/prevention & control , Infant, Premature , Ultrasonography , ThoraxABSTRACT
Background and Objectives@#The benefits of rapid on-site evaluation (ROSE) of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid masses have not been convincingly shown in large, randomized trials. New equipment using EUS-guided fine needle biopsy (FNB) allows for more material to be acquired that may obviate the need for ROSE. This study aimed to evaluate if EUS-FNB without ROSE was non-inferior to EUS-FNA with ROSE in solid pancreatic masses (SPMs). @*Methods@#Patients with SPMs requiring tissue sampling were randomly assigned to undergo either EUS-FNA with ROSE or EUS-FNB without ROSE. The touch-imprint cytology technique was used to perform ROSE. The primary endpoint was diagnostic accuracy and secondary endpoints were specimen quality, complication rates, and procedure time. @*Results@#Seventy-eight patients were randomized and analyzed (39 EUS-FNA with ROSE and 39 EUS-FNB without ROSE). Non-significantly different diagnostic accuracies were noted in both groups (97% with ROSE and 100% without ROSE, P < 0.371). The bloodiness of histologic samples and complication rates were not significantly different between groups. A significantly shorter mean sampling procedural time was noted for EUS-FNB over EUS-FNA with ROSE (30.4 ± 10.4 vs 35.8 ± 9.8 minutes, P < .02). @*Conclusions@#EUS-FNB demonstrated equal diagnostic accuracy with shorter procedure times in evaluating SPMs compared to EUS-FNA with ROSE. These new-generation FNB needles may obviate the need for ROSE.
Subject(s)
Pancreatic NeoplasmsABSTRACT
Ductal carcinoma in situ(DCIS),a pathological type of breast cancer that is limited to the terminal ducts of the breast without breaking through the basement membrane,is considered as the precursor of invasive ductal carcinoma(IDC).When DCIS breaks through the basement membrane and invades surrounding tissues,it can form infiltrating lesions.If the maximum diameter of a single infiltrating lesion is less than 1mm or the maximum diameter of multiple infiltrating lesions is less than 1mm,it is defined as ductal carcinoma in situ with microinvasion(DCIS-Mi).About 12%-40%of untreated and intervened DCIS will progress to IDC,and DCIS and IDC can also coexist.However,there is a considerable portion of DCIS that never progresses with good prognosis.Recently,overdiagnosis and overtreatment of DCIS have become the research hotspots.The histological grade of DCIS is mainly based on the morphology of the nucleus,which is divided into three nuclear levels:low,medium,and high.There are also significant differences in receptor expression and molecular type distribution between DCIS,DCIS-Mi,and IDC.For DCIS with or without microinvasion as well as different histological grades,there are many controversies about the treatment regimen,clinical prognosis and risk.The development of modern imaging technology has achieved preliminary evaluation of histological grading,infiltration status,and prognosis prediction of DCIS.The most commonly used breast imaging techniques in clinical practice currently include mammography(MG),ultrasound(US),and magnetic resonance imaging(MRI).The imaging principles of these three techniques are different,and each has its own advantages and disadvantages in breast disease imaging diagnosis.However,they can complement each other and play an important role in disease diagnosis,treatment,and prognosis evaluation.Mammography has the advantages of safety,reliability and good repeatability.It is the preferred screening method for breast cancer recommended by international guidelines.The main manifestations of DCIS on MG can be divided into non calcified lesions and calcified lesions.On US,the main manifestations are lesions and non-lesion type,which can be further divided into hypoechoic changes,calcification,ductal changes,and structural disorders and distortions.MRI has higher sensitivity in detecting DCIS without calcification and multifocal DCIS compared with MG,and has higher accuracy in evaluating the lesion range.However,there are also shortcomings such as low diagnostic specificity and insensitivity to microcalcification display.In addition,radiomics has great potential in the histopathological evaluation,prediction,and guidance of individualized precision treatment of DCIS.In the current era of precision medicine,image features,histopathology,molecular genes,etc.are increasingly significant in predicting the prognosis of breast cancer.The early accurate diagnosis and molecular type of DCIS are also extremely important in clinical work.It has become a consensus in clinical treatment to predict the potential benefits of different treatments through molecular typing,histological grade,and imaging findings,in order to develop the most suitable personalized treatment plan.This article reviewed the correlation between imaging features and the molecular subtype,histopathology and prognosis of DCIS.
ABSTRACT
Objective To evaluate the value of miniprobe endoscopic ultrasound(EUS)in guiding endoscopic treatment of small-diameter(maximum diameter less than 1 cm)and low-grade(G1 grade)rectum neuroendocrine neoplasm(R-NEN),and to provide evidence and clues for its clinical application and further research.Methods The clinical data of 85 cases of low-grade(G1 grade)R-NEN with a maximum diameter of less than 1 cm who underwent endoscopic treatment in our center from January 2014 to December 2020 were retrospectively analyzed.The patients were divided into the EUS group(37 cases)and control group(48 cases)according to whether EUS was performed before endoscopic treatment.The positive rate of incision margin,the incidence of complications,the recurrence rate,the hospital stay,the cost of hospitalization and endoscopic therapy were compared between the two groups.Results The positive rate of incision margin in the EUS group was significantly lower than that in control group(P<0.05).There was no significant difference in the incidence of complications,tumor recurrence rate,hospital stay or hospital costs between the two groups(P>0.05).There was statistically significant difference in the endoscopic therapy between the two groups(P<0.05).Conclusion Evaluating the lesion depth of small-diameter and low-grade(G1 grade)R-NEN before surgery by miniprobe EUS and selecting endoscopic surgery according to its results of can significantly reduce the residual risk of resection margin tumors.
ABSTRACT
Objective To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)combined with serum Smad ubiquitin regulatory factor 1(SMURF1)detection for thyroid cancer.Methods A total of 144 suspected thyroid cancer patients admitted to Lishui branch of Zhongda Hospital Affiliated to Southeast University from February 2019 to February 2020 were selected as the study subjects.Based on the histopathological results,they were divided into the thyroid cancer group(76 cases)and the benign group(68 cases).All patients underwent contrast-enhanced ultrasound examination and serum SMURF1 level detection;the diagnostic value of contrast-enhanced ultrasound parameters,serum SMURF1 detection alone,and the combination of the two methods for thyroid cancer were analyzed.Results Contrast-enhanced ultrasound parameters peak intensity(PI),mean perfusion intensity(SImean)and maximum perfusion intensity(SImax)in the thyroid cancer group were lower than those in the benign group,and the level of SMURF1 mRNA was higher than that in the benign group(P<0.05).The sensitivity of contrast-enhanced ultrasound parameter SImax in the diagnosis of thyroid cancer was 82.89%,the specificity was 72.06%,the accuracy was 77.78%,and the Kappa value was 0.552.The sensitivity of serum SMURF1 in the diagnosis of thyroid cancer was 65.79%,the specificity was 94.12%,the accuracy was 79.17%,and the Kappa value was 0.589.The sensitivity,specificity,accuracy and Kappa value of SImax combined with serum SMURF1 in the diagnosis of thyroid cancer were 97.37%,85.29%,91.67%and 0.832,respectively,which were higher than those of SImax and SMURF1 alone(P<0.05),the AUC of the combination of the two methods was 0.927,which was significantly higher than that of the two methods alone(Zcombined vs.SImax=3.999,P<0.001;Zcombined vs.SMURF1=3.270,P=0.001).Conclusion Contrast-enhanced ultrasound combined with serum SMURF1 detection can improve the diagnostic efficiency of thyroid cancer,which may avoid the over-diagnosis on the premise of ensuring the effective diagnosis of thyroid cancer patients.
ABSTRACT
Objective:To explore the effect of low intensity pulsed ultrasound(LIPUS)on inhibiting the abnormal cell phenotype of fibroblast-like synoviocytes in rheumatoid arthritis(RA-FLS)and possible mechanism. Method:Synoviocytes were isolated by using enzyme digestion,and the morphology of cells was observed un-der microscope.At the same time,the expression of Vimentin protein was detected by immunofluorescence method to identify RA-FLS.Cells cultured in vitro were divided into four groups:control group,LIPUS group,tumor necrosis factor(TNF-α)group and TNF-α+LIPUS group or three groups:control group,interleu-kin-6(IL-6)group and IL-6+LIPUS group.The effects of LIPUS on RA-FLS cell viability and proliferation were detected by CCK8 and EDU assay respectively,and the effects of LIPUS on RA-FLS migration were ob-served by scratch test and Transwell migration assay.RT-qPCR was used to detect the gene expression of im-portant cytokines,chemokines and matrix metalloproteinases(MMPs)in RA-FLS.ELISA was used to further detect the effect of LIPUS on the expression of IL-6,a key effector of RA-FLS,and the effects of LIPUS on mitogen-activated protein kinase(MAPK)signaling pathway in RA-FLS were detected by Western Blot. Result:Purified RA-FLS were obtained.Firstly,LIPUS could suppress the cell activity(P<0.00l)and prolifer-ation(P=0.007)induced by TNF-α in RA-FLS cultured in vitro.However,the migration and the transcription levels of MMPs related to migration(MMP2 and MMP9)were not significantly different between groups(P>0.05).LIPUS could inhibit the high expression of IL-6 and interleukin-8(IL-8)at the mRNA level in the in-flammatory environment induced by TNF-α(P<0.001),but there was no significant difference in the suppres-sion of interleukin-1β(IL-1β),MMP1 and MMP13(P>0.05).In addition,compared with untreated group,LI-PUS could inhibit the secretion of IL-6 in RA-FLS induced by TNF-α(P<0.001),and also inhibited the pro-liferation of RA-FLS induced by IL-6(P-0.003).Finally,LIPUS could inhibit the phosphorylation of p38 MAPK and c-Jun N-terminal kinase(JNK)in MAPK signaling pathway(P=0.033),but the effect on the phosphorylation of extracellular signal-regulated kinas 1/2(ERK1/2)was not significantly(P>0.05). Conclusion:LIPUS could reduce the abnormal proliferation of RA-FLS in inflammatory state without affecting its migration,which might be related to the inhibition of p38/JNK-IL-6 signaling pathway.
ABSTRACT
Objective:To analyze the consistency and repeatability of ultrasonography in diaphragm function evaluation. Method:Sixty healthy subjects participated in the present study,using a PA12A portable color doppler untra-sound diagnostic system.The diaphragm data were recorded during calm breathing and deep breathing,includ-ing diaphragm muscle mobility during calm breathing and deep breathing,diaphragmatic thickness during calm exhalation and calm inspiration,and diaphragmatic thickness during deep exhalation and deep inspiration.The in-tra-test reliability,inter-tester reliability and retest reliability of the above indexes were analyzed respectively. Result:For intra-test reliability,the intra-class correlation coefficient(ICC)values for diaphragm muscle mo-bility during calm breathing,diaphragm muscle mobility during deep breathing,diaphragmatic thickness during calm exhalation,diaphragmatic thickness during calm inspiration,diaphragmatic thickness during maximal exha-lation and diaphragmatic thickness during maximal inspiration were 0.99,0.99,0.99,0.99,0.99,0.99 and 0.99,respectively.The ICC values for the six indicators were 0.84,0.80,0.82,0.82,0.83,and 0.77 for in-ter-tester reliability.For retest reliability,the ICC values for the six indicators were 0.98,0.86,0.98,0.97,0.94,and 0.86 for relative reliability.The standard error of measurement(SEM)for the absolute reliability of the six indicators were 0.09,0.39,0.01,0.02,0.02,0.03,SEM%were 5.23%,8.40%,5.38%,5.7%,8.17%,8.77%,and the minimal detectable change(MDC)were 0.25,1.08,0.03,0.04,0.04,0.09,and MDC%were 14.49%,23.28%,14.9%,15.8%,22.64%,24.31%,respectively.Bland-Altman graphical analy-sis showed no systematic errors. Conclusion:Ultrasound has good reliability in diaphragm function evaluation and can provide objective evi-dence in clinical application.
ABSTRACT
Objective:To investigate the correlation between diaphragmatic-rapid shallow breathing index (D-RSBI) and lung ultrasound score (LUS) in elderly patients with mechanical ventilation and its predictive value for weaning results.Methods:A retrospective study was conducted. The clinical data of elderly patients (age > 60 years old) with invasive positive pressure ventilation (IPPV) admitted to the department of intensive care unit (ICU) of the First Affiliated Hospital of Jinzhou Medical University from January 2021 to June 2022 were enrolled. According to the outcome of withdrawal, the patients were divided into successful and failed groups. The differences in gender, age, acute physiology and chronic health evaluation Ⅱ (APACHEⅡ), D-RSBI and LUS before weaning and extubation were compared between the two groups. Pearson correlation was used to analyze the correlation between D-RSBI and LUS. The predictive value of D-RSBI and LUS on weaning results of elderly patients with IPPV was analyzed by receiver operator characteristic curve (ROC curve).Results:A total of 398 elderly patients with IPPV were enrolled, including 300 successful weaning patients and 98 failed weaning patients. There were no significant differences in gender and age between the failed group and successful group [male: 55.1% (54/98) vs. 59.0% (177/300), age (years old): 67.02±5.03 vs. 66.96±4.99, both P > 0.05]. APACHEⅡ score in the failed group was significantly higher than that in the successful group (17.09±3.30 vs. 16.06±3.81, P < 0.05), and the D-RSBI and LUS score before extubation were significantly higher than those in the successful group [D-RSBI (time·min -1·mm -1): 2.19±0.33 vs. 1.60±0.22, LUS: 17.30±3.04 vs. 11.97±3.20, both P < 0.01]. All patients showed a significant positive correlation between D-RSBI and LUS score ( r = 0.406, P = 0.000). ROC curve analysis showed that the area under the curve (AUC) of D-RSBI for predicting weaning outcomes in elderly IPPV patients was 0.920, with a 95% confidence interval (95% CI) of 0.881-0.958 and P = 0.000. When the cut-off value was 1.85 times·min -1·mm -1, the sensitivity was 88.7% and the specificity was 86.7%. The AUC of LUS score for predicting weaning outcome in elderly IPPV patients was 0.875, with a 95% CI of 0.839-0.912 and P = 0.000. When the cut-off value was 14.50, the sensitivity was 75.7% and the specificity was 84.7%. Conclusion:There is a significant correlation between D-RSBI and LUS score in elderly mechanically ventilated patients, both of them can predict weaning outcome in elderly patients with mechanical ventilation.
ABSTRACT
Objective:To explore the application value of dynamic monitoring of gastric residual volume (GRV) in achieving different target energy in severe mechanical ventilation patients.Methods:A prospective randomized controlled study was conducted. Forty-two patients with mechanical ventilation admitted to the department of critical care medicine of General Hospital of Ningxia Medical University from July to December 2022 were enrolled. According to the random number table method, patients were divided into GRV guided enteral nutrition by traditional gastric juice pumpback method (control group, 22 patients) and GRV guided enteral nutrition by bedside ultrasound (test group, 20 patients). General data were collected from both groups, and clinical indicators such as hypersensitive C-reactive protein (hs-CRP), interleukin-6 (IL-6), neutrophil percentage (Neut%), procalcitonin (PCT), absolute lymphocytes (LYM), prealbumin (PA), and retinol-binding protein (RBP) were dynamically observed. Inflammation, infection, immunity, nutritional indicators, and the incidence of reflux/aspiration, ventilator-associated pneumonia (VAP) were compared between the two groups, and further compared the proportion of patients with respectively to reach the target energy 25%, 50%, and 70% on days 1, 3, and 5 of initiated enteral nutrition.Results:① There were no significant differences in gender, age, body mass index (BMI), duration of mechanical ventilation, and acute physiology and chronic health evaluationⅡ(APACHEⅡ), sequential organ failure assessment (SOFA), severe nutritional risk score (NUTRIC) at admission between the two groups, indicating comparability. ② On day 1 of initiated enteral nutrition, there were no significant differences in infection, inflammation, immunity and nutrition indicators between the two groups. On day 3 of initiated enteral nutrition, the hs-CRP in the test group was lower than that control group, LYM and PA were higher than those control group [hs-CRP (mg/L): 129.60±75.18 vs. 185.20±63.74, LYM: 1.00±0.84 vs. 0.60±0.41, PA (mg/L): 27.30±3.66 vs. 22.30±2.55, all P < 0.05]. On day 5 of initiated enteral nutrition, the hs-CRP, Neut%, PCT in the test group were lower than those control group, LYM and PA were higher than those control group [hs-CRP (mg/L): 101.70±54.32 vs. 148.40±36.35, Neut%: (85.50±7.66)% vs. (92.90±6.01)%, PCT (μg/L): 0.7 (0.3, 2.7) vs. 3.6 (1.2, 7.5), LYM: 1.00±0.68 vs. 0.50±0.38, PA (mg/L): 27.10±4.57 vs. 20.80 ± 3.51, all P < 0.05]. There were no significantly differences in IL-6 and RBP between the two groups at different time points. ③ The proportion of 50% and 70% of achieved target energy in the test group on day 3, day 5 of initiated enteral nutrition were higher than those of the control group (70.0% vs. 36.4%, 70.0% vs. 36.4%, both P < 0.05). ④ The incidence of reflux/aspiration and VAP in the test group on day 5 of initiated enteral nutrition were significantly lower than those control group (incidence of reflux/aspiration: 5.0% vs. 28.6%, incidence of VAP: 10.0% vs. 36.4%, both P < 0.05). Conclusion:Dynamic monitoring of GRV by bedside ultrasound can accurately improve the proportion of 50% of achieved target energy on day 3 and 75% on day 5 in severe mechanical ventilation patients, improve the patient's inflammation, immune and nutritional status, and can prevent the occurrence of reflux/aspiration and VAP.