ABSTRACT
Objective: To investigate the effect of three-dimensional (3D) printing guide plate on improving femoral rotational alignment and patellar tracking in total knee arthroplasty (TKA). Methods: Between January 2018 and October 2018, 60 patients (60 knees) with advanced knee osteoarthritis who received TKA and met the selection criteria were selected as the study subjects. Patients were randomly divided into two groups according to the random number table method, with 30 patients in each group. The TKA was done with the help of 3D printing guide plate in the guide group and following traditional procedure in the control group. There was no significant difference in gender, age, disease duration, side, and preoperative hip-knee-ankle angle (HKA), posterior condylar angle (PCA), patella transverse axis-femoral transepicondylar axis angle (PFA), Hospital for Special Surgery (HSS) score, and American Knee Society (AKS) score ( P>0.05). Results: All incisions healed by first intention and no complications related to the operation occurred. All patients were followed up 10-12 months, with an average of 11 months. HSS score and AKS score of the two groups at 6 months after operation were significantly higher than those before operation ( P0.05). Postoperative X-ray films showed that the prosthesis was in good position, and no prosthesis loosening or sinking occurred during follow-up. HKA, PCA, and PFA significantly improved in the two groups at 10 months after operation compared with those before operation ( P<0.05). There was no significant difference in HKA at 10 months between the two groups ( t=1.031, P=0.307). PCA and PFA in the guide group were smaller than those in the control group ( P<0.05). Conclusion: Application of 3D printing guide plate in TKA can not only correct the deformity of the knee joint and alleviate the pain symptoms, but also achieve the goal of the accurate femoral rotation alignment and good patellar tracking.
ABSTRACT
Objective: To explore the gait trajectory characteristics of patients after total knee arthroplasty (TKA) assisted by three-dimensional (3D) printing navigation template. Methods: Twenty female patients (20 knees) with knee osteoarthritis who were treated with TKA assisted by 3D printing navigation template between February 2017 and February 2018 were selected as the 3D printing group. The patients were 50-69 years old, with an average age of 57.2 years. The disease duration was 4-7 years, with an average of 5.6 years. The osteoarthritis was classified as Kellgren-Lawrence Ⅲ level in 5 cases and Ⅳ level in 15 cases. The preoperative hip-knee-ankle angle (HKA) was (170.8±5.6)°. All patients were varus deformity. According to age and affected side, 20 healthy female volunteers were selected as the control group. The volunteers were 51-70 years old, with an average age of 56.7 years. Preoperative HKA was (178.8±0.6)°. There was significant difference in HKA between the two groups ( P>0.05). The HKA, Western Ontario and McMaster University Osteoarthritis Index (WOMAC), and visual analogue scale (VAS) scores of the 3D printing group before and after operation were compared. At 6 months after operation, the gait trajectory characteristics of 3D printing group and control group were analyzed by Vicon gait capture system. The kinematics parameters included velocity, cadence, stride length, maximum knee flexion angle (stance), minimum knee flexion angle (stance), maximum knee flexion angle (swing), mean hip rotation angle (stance), mean ankle rotation angle (stance). Results: The incisions of 3D printing group healed by first intention, with no complications. All patients were followed up 7-12 months (mean, 9.0 months). The WOMAC and VAS scores at 6 months after operation were significant lower than those before operation ( P<0.05). The HKA was (178.8±0.8)° at 4 weeks after operation and the difference was significant when compared with that before operation ( t=39.203, P=0.000). The position of the prosthesis was good. The femoral posterior condyle osteotomy line, surgical transepicondylar axis, and patella transverse line were parallel, varus deformity was corrected, and lower limb alignment was restored to neutral position. Gait analysis at 6 months after operation showed that the differences in all kinematics parameters between the two groups were significant ( P<0.05). Conclusion: Assisted by 3D printing navigation template, TKA can alleviate pain symptoms and correct deformity, with satisfactory early effectiveness. Compared with healthy people, the early postoperative gait of the patients were characterized by decreasing velocity, cadence, stride length, knee flexion range, and increasing compensatory hip and ankle rotation range.
ABSTRACT
Objective To investigate the role of next generation sequencing technology in the detection of pathogenic bacteria in synovial fluid of prosthetic joint infection.Methods Nine samples of synovial fluid specimens of prosthetic joint infection patients with positive microbial culture from October,1 2016 to April 1,2017 were collected.Each specimen (200 μl) was used for next generation sequencing.Total DNA was extracted from synovial fluid samples.The collected DNA samples were amplified by PCR in the V4 region of 16S rDNA gene.The amplified products were sequenced using the Illumina Miseq platform,2× 250 bp double-end sequencing strategy.The sequencing results were compared with the SILVA database to analyze the types of bacteria and relative abundance in the DNA samples.A total of 200 μl sterile double-distilled deionized water was used as control.Results Nine cases of microbial culture positive prosthetic joint infection synovial fluid DNA samples were sequenced by 16S rDNA amplicon sequencing and yielded 3 132 415 high-quality reads and 3 752 operational taxonomic units (OTU).At the level of bacteria,a total of 9 different bacterial gates were detected on 9 DNA samples.At the level of bacteria,34 different bacteria were detected by 16S rDNA amplicon sequencing.Each DNA sample was detected by 16S rDNA amplicon sequencing and the bacterial genus was identical to that of laboratory culture.16S rDNA amplicon sequencing detected more species of bacteria [6(3,9.5)] than bacterial cultures [(1.0(1.0,1.0)].There was statistically significant difference in the number of bacteria detected in the same specimen between the 16S rDNA amplicon sequencing and the laboratory culture (Z=2.533,P=0.011).Among them,the dominant bacterial population (highest abundance) detected by 16S rDNA amplicon sequencing in four DNA samples was consistent with the results of laboratory culture.Conclusion In the prosthetic joint infection,the 16S rDNA amplicon sequencing technology can accurately detect pathogens that are consistent with the laboratory culture,and can detect other bacteria outside the laboratory culture.This technology can provide the basis for clinical diagnosis and antibiotic selection.
ABSTRACT
Objective To study the clinical efficacy of total hip arthroplasty for treatment of end-stage hip with pigmented villonodular synovitis(PVNS).Methods From January 2000 to March 2015,a total of 34 patients with hip PVNS were treated by total hip arthroplasty (THA) combined with synovectomy.Pelvic X-ray,CT and MRI examinations were performed before the surgery,and Harris hip joint function score was performed before and after surgery.Systematic rehabilitation training was performed after the operation,and the hip joint X-ray films were regularly reviewed.Results All the 34 patients were reviewed and observed for an average of 5.2 years (ranged from 1.5 to 7 years).The position of the prosthesis was good and the motion of the joint was satisfactory.The mean preoperative Harris hip scores improved from (45.0 ± 6.4) perioperatively to (90.2 ± 3.2) postoperatively,with statistically significant difference (t =0.468,P < 0.05).None of the patients had clinical or radiographic evidence of recurrent PVNS.Conclusion Total hip arthroplasty combined with synovectomy is an effective therapeutic choice for end-stage hip with pigmented villonodular synovitis,which can improve the clinical results and prevent the disease recurrence.
ABSTRACT
Objective To observe the analgesic effect of ultrasound-guided and nerve stimulator after artificial total knee athroplasty(TKA).Methods Forty elective cases receiving TKA under gen-eral anesthesia were randomly allocated into the ultrasound group (group C)and stimulator group (group S).The time for nerve block,onset time and complications were recorded in both groups. Results Compared to group S,the time for nerve block and onset time was significantly shortened in group C (P <0.05).There was no statistical difference in times of pressing analgesic pump and VAS score in postoperative 48 h.One patient suffered from nerve injury and two underwent vascular dam-age and hematoma in group S,while no complication was found in group C.Conclusion Compared to nerve stimulator,ultrasound-guided continuous femoral nerve block(CFNB)may reduce nerve block time and onset time and decrease complications,so that to increase safety of CFNB.
ABSTRACT
[Objective]To summarize the middle-term results of unicompartment knee arthroplasty(UKA),and postulate a new specific assessment score.[Method]From March 2004 to September 2006,unicompartment knee arthroplasty had been proformed in 22 patients(22 knees)with unicompartment osteoarthritis.The mean follow-up period was 34 months(range from 14 to 49 months).The HSS score、KSS score and WOMAC score were used to evaluate the outcomes of UKA at the time of preoperation and follow-up respectively.A new unicompartment knee arthroplasty specific score was postulated to evaluate the results of UKA.[Result]At the time of the final follow-up,pain relief was significant in all patients,and the range of motion and quality of living were improved.The HSS score,KSS score and WOMAC score were significantly improved compared with pre-operation(P
ABSTRACT
[Objective]To explore the advantages and disadvantages of minimal incision surgery(MIS) for total hip replacement.[Methods]Thirty-two patients(37 hips) who had undergone a MIS were compared with 32 patients(37hips) who had undergone conventional incision surgery with similar condictions.The length of incision,operation time,intraoperative blood loss,postoperative drainage,hospitalized days and complications were observed.[Results]The average incision length was 7.7 cm for MIS group and 11.5 cm for conventional incision group(P0.05).In MIS group,greater trochanter fracture occured in 1 patient during operation.Dislocation occurred in another patient with anterolateral approach 3 days postoperatively because of malposition of the cup,the cup was then adjusted to proper position by re-operation with extended incision length.In conventional incision group,no complication occured during or after operations.[Conclusion]Total hip replacement with the incision length of 6~8.5 cm is a very demanding technique.There were no much advantages of MIS for total hip replacement concerning surgical time,blood loss or trauma compare with a conventional incision surgery.The incision length for total hip replacement should not be stressed.The most important thing for total hip replacement is not the length of the incision and the length of incision should not be reduced at the price of more soft tissue injury.