Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 131
Filter
1.
Braz. dent. j ; 33(3): 99-108, July-Sept. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384038

ABSTRACT

Abstract This study showed the synthesis of Glass ionomer cements (GIC) modified with calcium phosphate nanoparticles (nCaP). The nCaP/GIC were submitted to mechanical compression and diametral tensile tests. The biocomposite were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR). Cytotoxicity and cell viability tests were performed on the human bone marrow mesenchymal stem cells using a 3-(4,5-dimethylthiazol-2yl)2,5-diphenyl- tetrazolium-bromide assay and LIVE/DEAD assays. Statistically significant differences were observed for mechanical properties (Kruskal-Wallis, p<0.001), nCaP/GIC showed higher resistance to compression and diametral traction. The SEM analyses revealed a uniform distribution nCaP in the ionomer matrix. The EDX and XRD results indicated that hydroxyapatite and calcium β-triphosphate phases. The FTIR spectra revealed the asymmetric band of ν3PO43- between 1100-1030cm-1 and the vibration band associated with ν1PO43- in 963cm-1 associated with nCaP. The nCaP/GIC presented response to adequate cell viability and non-cytotoxic behavior. Therefore, the new nCaP/GIC composite showed great mechanical properties, non-cytotoxic behavior, and adequate response to cell viability with promising dental applications.


Resumo Este estudo apresenta a síntese de cimentos de ionômero de vidro (GIC) modificados com nanopartículas de fosfato de cálcio (nCaP). Os nCaP / GIC foram submetidos a ensaios mecânicos de compressão e tração diametral. Os biocompósitos foram caracterizados por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva de raios-X (EDX), difração de raios-X (XRD) e espectroscopia de infravermelho com transformada de Fourier (FTIR). Os testes de citotoxicidade e viabilidade celular foram realizados em células-tronco mesenquimais da medula óssea humana usando um ensaio de 3- (4,5-dimetiltiazol-2-il) 2,5-difeniltetrazólio-brometo e ensaios LIVE / DEAD. Diferenças estatisticamente significativas foram observadas para as propriedades mecânicas (Kruskal-Wallis, p <0,001), nCaP / GIC apresentou maior resistência à compressão e tração diametral. As análises de SEM revelaram uma distribuição uniforme de nCaP na matriz do ionômero. Os resultados de EDX e DRX indicaram fases de hidroxiapatita e β-trifosfato de cálcio. Os espectros de FTIR revelaram a banda assimétrica de ν3PO4 3- entre 1100-1030cm-1 e a banda de vibração associada a ν1PO4 3- em 963cm-1 associada a nCaP. O nCaP / GIC apresentou resposta adequada à viabilidade celular e comportamento não citotóxico. Portanto, o novo compósito nCaP / GIC apresentou ótimas propriedades mecânicas, comportamento não citotóxico e resposta adequada à viabilidade celular com promissoras aplicações odontológicas.

2.
Dental press j. orthod. (Impr.) ; 27(3): e222116, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1384695

ABSTRACT

ABSTRACT Objective: This study aimed to investigate the antimicrobial activity and shear bond strength (SBS) of orthodontic brackets to bovine enamel using experimental composites with different concentrations of silicon dioxide-coated silver nanoparticles (Ag@SiO2 NPs). Methods: Fifty bovine incisors were divided into five groups according to the composite (n = 10): G1 - Control Group (Transbond XT Resin), G2 - Experimental composite without Ag@SiO2 NPs; G3 - Experimental composite with 0.5% of Ag@SiO2 NPs; G4 - Experimental composite with 1% of Ag@SiO2 NPs; G5 - Experimental composite with 3% of Ag@SiO2 NPs. The SBS test was performed using a universal mechanical testing machine, and the adhesive remnant index (ARI) was analyzed by optical microscopy. For the antimicrobial activity evaluation, Streptococcus mutans (S. mutans) biofilm was formed for three days in hydroxyapatite discs. Posteriorly, S. mutans colony forming units (CFU) were evaluated. For SBS analysis, Analysis of Variance was used, followed by the Tukey test, at a 5% statistical significance level. The CFU data were analyzed by Kruskal-Wallis, followed by Dunn as a post-hoc test. The ARI results were analyzed descriptively. Results: There was no statistically significant difference in SBS values between the experimental and control groups (p>0.05). A 3% incorporation of Ag@SiO2 NPs statistically reduced the SBS values (p<0.05) compared to the 1% group. The addition of 3% of Ag@SiO2 NPs to the composites significantly reduced S. mutans biofilm formation, compared to group G2 (p<0.05). Conclusion: Composites incorporating 3% of Ag@SiO2 NPs presented similar SBS values compared to the control group, and showed significant antimicrobial activity.


RESUMO Objetivo: O presente estudo objetivou investigar a atividade antimicrobiana e a resistência de união ao cisalhamento (RU) de braquetes ortodônticos colados em esmalte bovino, utilizando compósitos experimentais com diferentes concentrações de nanopartículas de prata revestidas com dióxido de silício (NPs Ag@SiO2). Material e Métodos: Cinquenta incisivos bovinos foram divididos em cinco grupos, de acordo com o compósito utilizado (n = 10): G1 - Grupo Controle (Resina Transbond XT); G2 - Compósito Experimental sem NPs Ag@SiO2; G3 - Compósito Experimental com 0,5% de NPs Ag@SiO2; G4 - Composto Experimental com 1% de NPs Ag@SiO2; e G5 - Compósito Experimental com 3% de NPs Ag@SiO2. O teste de RU foi realizado em máquina universal de ensaios mecânicos, e o índice de adesivo remanescente (IAR) foi analisado por microscopia óptica. Para a avaliação da atividade antimicrobiana, biofilme de S. mutans foi formado por três dias em discos de hidroxiapatita. Posteriormente, foram avaliadas as unidades formadoras de colônias (UFC) de S. mutans. Para a análise de RU, foi utilizada a Análise de Variância, seguida do teste de Tukey, com nível de significância estatística de 5%. Os dados de UFC foram analisados por meio do teste de Kruskal-Wallis, seguido do teste post-hoc de Dunn. Os resultados de IAR foram analisados descritivamente. Resultados: Não houve diferença estatisticamente significativa nos valores de RU entre os grupos experimentais e o grupo controle (p> 0,05). A incorporação de 3% de NPs Ag@SiO2 reduziu estatisticamente os valores de RU (p< 0,05), em comparação ao grupo com 1%. A adição de 3% de NPs Ag@SiO2 ao compósito reduziu significativamente a formação de biofilme de S. mutans, em relação ao grupo G2 (p< 0,05). Conclusão: Os compósitos com incorporação de 3% de NPs Ag@SiO2 apresentaram valores de RU semelhantes ao grupo controle e demonstraram significativa atividade antimicrobiana.

3.
Braz. dent. j ; 32(4): 106-115, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345518

ABSTRACT

Abstract The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) on microtensile bond strength (µTBS) between an adhesive system and under 3 dentin conditions. For that, this study evaluated the adhesive interface at initial, after 6 months and 1 year of storage. Forty-eight human third molars were prepared and randomly divided into 3 groups, according to dentin substrates: sound dentin (Sd), caries-infected dentin (Ci) and caries-affected dentin (Ca). The groups were subdivided into two according to the dentin pre-treatment: application of 2% CHX or without pre-treatment (control). The dentin surfaces were etched with 35% phosphoric acid gel and bonded with Adper Single Bond 2 (3M ESPE) adhesive system according to manufacturer's instructions. Subsequently, the specimens were stored in deionized water at 37°C for 24h, 6 months and 1 year. Two additional teeth were used to analyze the bonding interfaces by SEM. Data was submitted to three-way ANOVA in a split plot design and Tukey's test (α = 0.05). The results showed that Ci decreased µTBS values when compared to Ca and Sd, regardless storages time or treatment. Stored samples for 6 months and 1 year decreased the µTBS for the control group, but no difference was found between storages time for the CHX group. As a conclusion, the 2% CHX application after etching showed improved dentin bond strength in the storage time, regardless of the substrates evaluated.


Resumo O objetivo deste estudo foi avaliar o efeito do digluconato de clorexidina 2% (CHX) na resistência de união à microtração (µTBS) entre um sistema adesivo e sob 3 condições de dentina. Para tanto, este estudo avaliou a interface adesiva no início, após 6 meses e 1 ano de armazenamento. Quarenta e oito terceiros molares humanos foram preparados e divididos aleatoriamente em 3 grupos, de acordo com os substratos dentinários: dentina hígida (Dh), dentina infectada por cárie (Di) e dentina afetada por cárie (Da). Os grupos foram subdivididos em dois de acordo com o pré-tratamento: aplicação de CHX 2% ou sem pré-tratamento (controle). As superfícies da dentina foram condicionadas com gel de ácido fosfórico a 35%, em seguida, utilizou-se o sistema adesivo Adper Single Bond 2 (3M ESPE) de acordo com as instruções do fabricante. Posteriormente, os corpos-de-prova foram armazenados em água deionizada a 37°C por 24h, 6 meses e 1 ano. Dois dentes adicionais foram usados ​​para analisar as interfaces de união no MEV. Os dados foram submetidos a ANOVA três fatores em esquema de parcela subdividida e ao teste de Tukey (α = 0,05). Os resultados mostram que a Di diminuiu os valores de µTBS quando comparado as Da e Dh, independente do tempo de armazenamento ou tratamento. Amostras armazenadas por 6 meses e 1 ano diminuíram a µTBS para o grupo de controle, mas nenhuma diferença foi encontrada entre o tempo de armazenamento para o grupo CHX. A aplicação de CHX 2% após o condicionamento apresentou melhora na resistência de união à dentina no tempo de armazenamento, independente dos substratos avaliados.


Subject(s)
Humans , Dental Bonding , Dentin-Bonding Agents , Tensile Strength , Materials Testing , Composite Resins , Resin Cements , Dentin
4.
Braz. dent. j ; 32(4): 96-105, July-Aug. 2021. tab
Article in English | LILACS, BBO | ID: biblio-1345515

ABSTRACT

Abstract This study evaluated the effect of post-cure heat treatment (PCHT) on the Knoop microhardness (KHN), degree of conversion (DC), color changes, and contrast ratio (CR) of four resin composites (RCs): Z100 (3M ESPE), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) and Empress Direct (Ivoclar Vivadent). Specimens (12 × 1 mm) were prepared for each material (n = 10 / group). After curing, samples were subjected to PCHT for 10 min at 100°C or 170°C. Control group was maintained at room temperature (24°C) for the same time. The DC was analyzed by FT-NIR immediately and 24 h after the PCHT (n = 3 / group). KHN was analyzed 24 h after PCHT (n = 10 / group). According to CIEDE2000 (∆E00), color measurements were obtained immediately after curing, five minutes after PCHT, and after seven days of storage in water, coffee, and red wine. Data were analyzed by One and Two-Way ANOVA (p < 0.05). Z100, Z350, and Estelite Omega showed increases in KHN with increased temperature (p < 0.05). PCHT at 100°C and 170°C led to a higher DC of all RCs (p < 0.05). Initially, the PCHT lead to increased ∆E00 values (p < 0.05), which was decreased after immersion in coffee and wine (p < 0.05). Considering the effect of PCHT and staining solutions, lower color changes were observed in the thermally treated specimens (p < 0.05). Taken collectively, the results suggest the PCHT as an economical and practical alternative to enhance direct RC's properties in direct-indirect and indirect restorations.


Resumo Este estudo avaliou o efeito do tratamento térmico pós-cura (PCHT) na microdureza Knoop (KHN), grau de conversão (DC), mudanças de cor e razão de contraste (CR) de quatro compósitos resinosos (RCs): Z100 (3M ESPE ), Z350 XT (3M ESPE), Estelite Omega (Tokuyama) e Empress Direct (Ivoclar Vivadent). Corpos de prova (12 × 1 mm) foram preparadas para cada material (n = 10 / grupo). Após a cura, as amostras foram submetidas ao PCHT por 10 min a 100 ou 170° C. O grupo controle foi mantido à temperatura ambiente (24° C) pelo mesmo tempo. O DC foi analisada por FT-NIR imediatamente e 24 h após a PCHT (n = 3 / grupo). KHN foi analisado 24 h após PCHT (n = 10 / grupo). De acordo com o CIEDE2000 (∆E00), as medidas de cor foram obtidas imediatamente após a cura, cinco minutos após a PCHT e após sete dias de armazenamento em água, café e vinho tinto. Os dados foram analisados por ANOVA de um e dois fatores (P < 0,05). Z100, Z350 XT e Estelite Omega mostraram aumentos no KHN com o aumento da temperatura (P < 0,05). PCHT a 100 ° C e 170 ° C levou a uma maior DC de todos os RCs (P < 0,05). Inicialmente, o PCHT levou ao aumento dos valores de ∆E00 (P < 0,05), que diminuiu após a imersão em café e vinho (P < 0,05). Considerando o efeito de PCHT e soluções de coloração, menores mudanças de cor foram observadas nas amostras tratadas termicamente (P < 0,05). Os resultados sugerem o PCHT como uma alternativa econômica e prática para aumentar as propriedades diretas de compósitos resinosos em restaurações diretas-indiretas e indiretas.


Subject(s)
Composite Resins , Hot Temperature , Surface Properties , Materials Testing , Coffee
5.
Odovtos (En línea) ; 23(2)ago. 2021.
Article in English | LILACS-Express | LILACS, SaludCR | ID: biblio-1386537

ABSTRACT

ABSTRACT: Purpose: The purpose of this study was to evaluate the discoloration of a dual-cure bulk-fill (DCBF) and light-cure bulk-fill (LCBF) composites relative to conventional composites (CC) after water and coffee immersion. Methods: One- hundred disc-shaped specimens (8mm in diameter × 4mm thickness) were prepared using five commercially available composites (n=10); two LCBF (XB-X-trafil Voco, FB-FiltekTM Bulk Fill), one DCBF (FU-Fill-upTM Coltene), and two CC (CE-Clearfil Majesty ES2, EQ-Estelite ΣQuick). Initial and final color readouts were measured with a spectrophotometer (Easyshade,Vita) according to the CIELAB color system. Statistical analyses were performed using 2-way ANOVA with Bonferroni adjustment to evaluate ΔE, ΔL, Δa, and Δb parameters (pFB≥XB>EQ≥CE in water immersion groups and XB>FB>EQ≥FU≥CE in coffee immersion groups. Conclusion: Within the limitations of this study, DCBF composite is more susceptible to intrinsic discoloration compared to LCBF and CC. However, DCBF exhibited lower extrinsic discoloration than LCBF and comparable with CC after coffee immersion. Depending on their chemical and structural compositions, composites will exhibit color change, which compromises the esthetic performance of composite restorations.


RESUMEN: Propósito: El propósito de este estudio fue evaluar la decoloración de resinas bulk de curado dual (DCBF) y bulk activadas por fotopolimerización (LCBF) en relación con las resinas convencionales (CC) después de la inmersión en agua y café. Métodos: Se prepararon cien muestras en forma de disco (8mm de diámetro × 4mm de espesor) utilizando cinco resinas compuestas disponibles comercialmente (n=10); dos LCBF (XB-X-trafil Voco, FB-FiltekTM Bulk Fill), un DCBF (FU-Fill-upTM Coltene) y dos CC (CE-Clearfil Majesty ES2, EQ-Estelite ΣQuick). Las lecturas de color inicial y final se midieron con un espectrofotómetro (Easyshade, Vita) de acuerdo con el sistema de color CIELAB. Los análisis estadísticos se realizaron utilizando ANOVA de 2 vías con ajuste de Bonferroni para evaluar los parámetros ΔE, ΔL, Δa y Δb (pFB≥XB>EQ≥CE en los grupos de inmersión en agua y XB>FB>EQ≥FU≥CE en los grupos de inmersión en café. Conclusión: Dentro de las limitaciones de este estudio, la resina DCBF es más susceptible a la decoloración intrínseca en comparación con LCBF y CC. Sin embargo, DCBF mostró una decoloración extrínseca más baja que LCBF y comparable con CC después de la inmersión en café. Dependiendo de sus composiciones químicas y estructurales, los composites mostrarán cambios de color, lo que compromete el desempeño estético de las restauraciones de resinas con el tiempo.


Subject(s)
Tooth Discoloration , Composite Resins/analysis
6.
J. health sci. (Londrina) ; 23(2): 85-91, 20210621.
Article in English | LILACS-Express | LILACS | ID: biblio-1283083

ABSTRACT

The aim of this study was to evaluate the color stability and the surface roughness of different composites brushed with toothpastes presenting different levels of abrasivity. Thirty discs of each material were obtained using michohybrid composites (Brilliant NG and Charisma Diamond) and a nanocomposite (Filtek Z350XT). The initial color (CIELab) and surface roughness (confocal laser scanning microscopy) of resin discs were evaluated. Afterwards, 10 specimens per group were brushed with the following dentifrices: Maximum Cavity Protection, Sensodyne Repair & Protect and Colgate Sensitive Pro-Relief. Brushing was performed with an electric toothbrush equipped with soft bristle head, with standard power and weight, for 30 minutes. Every 30 seconds, 1.0 ml of the slurry was injected between the bristles of the brush and the specimen. After abrasive challenge, the samples had their color and roughness reevaluated. Data were submitted to the Kruskal-Wallis test (color change) or the t-test (surface roughness). The level of significance was 5%. Results: Brushing did not significantly change the color of the composites tested in the study herein . On the other hand, the surface roughness of the composites was significantly affected by the abrasive challenge, regardless of the toothpaste used. The surface roughness change was similar for all the composites. The abrasive challenge with the toothpastes Maximum Cavity protection, Sensodyne Repair & Protect and Colgate Sensitive Pro-Relief was not able to significantly change the color of the composite resins. Nevertheless, the abrasive challenges significantly altered the surface roughness of all the evaluated composites. However, the changes in surface roughness were statistically similar in the microhybrid and nanofilled composites. (AU)


O objetivo deste estudo foi avaliar a estabilidade de cor e a rugosidade superficial de diferentes resinas compostas escovadas com dentifrícios de diferentes níveis de abrasividade. Trinta discos de cada material foram obtidos utilizando compósitos micro-híbridos (Brilliant NG e Charisma Diamond) e um nanocompósito (Filtek Z350XT). A cor inicial (CIELab) e a rugosidade superficial (microscopia confocal de varredura a laser) dos discos de resina foram avaliadas. Em seguida, 10 amostras por grupo foram escovadas com os dentifrícios Máxima Proteção Anticáries, Sensodyne Repair & Protect e Colgate Sensitive Pro-Alívio. A escovação foi realizada com uma escova elétrica com cabeça de cerdas macias, com potência e peso padronizados, durante 30 minutos. A cada 30 segundos, 1,0 ml da pasta era injetada entre as cerdas da escova e a amostra. Após o desafio abrasivo, as amostras tiveram sua cor e rugosidade reavaliadas. Os dados foram submetidos ao teste de Kruskal-Wallis (alteração de cor) ou ao teste t (rugosidade da superfície) (α=5%). A escovação não alterou significativamente a cor dos compósitos. Por outro lado, a rugosidade superficial dos compósitos foi significativamente afetada pelo desafio abrasivo, independentemente do dentifrício utilizado. A alteração da rugosidade superficial foi semelhante para todos os compósitos. O desafio abrasivo com a Máxima Proteção Anticáries, o Sensodyne Repair & Protect e o Colgate Sensitive Pro-Alívio não foi capaz de alterar significativamente a cor das resinas. Diferentemente, os desafios abrasivos alteraram significativamente a rugosidade superficial de todos os compósitos avaliados. No entanto, as mudanças na rugosidade foram estatisticamente semelhantes nos compósitos micro-híbridos e nanoparticulado. (AU)

7.
J. health sci. (Londrina) ; 23(2): 131-135, 20210621.
Article in English | LILACS-Express | LILACS | ID: biblio-1283121

ABSTRACT

Non-Carious Cervical Lesions are characterized by slow and progressive loss of hard tissue at the level of enamel-cement junction, without bacterial involvement. This work aimed to address a case report of restorative treatment in Class V cavities in multiple premolars using the directindirect technique with composite resin. A 42 year-old male patient presented for esthetic restorative treatment with the complaint of severe dentin hypersensitivity and wedged-shaped non-carious cervical lesions affecting the maxillary premolars. The restorative treatment chosen was a direct-indirect technique with composite performed into three sessions as follows: making the class V composite inlays, cementation, and final polishing. The direct-indirect technique as an alternative to the traditional direct technique has the benefits of a better contour of the restoration, since the finishing and polishing are made extraorally. Besides, the control of the polymerization stress and less discomfort to the patient are other advantages. In the case of direct-indirect class V restoration, the advantages far surpass those of the direct technique. (AU)


As Lesões Cervicais Não Cariosas se caracterizam pela perda lenta e progressiva de tecido duro próximo a junção cemento-esmalte, sem envolvimento bacteriano. Este trabalho tem o objetivo de relatar um caso clínico de tratamento restaurador em cavidades do tipo Classe V em pré-molares pela técnica direta-indireta com resina composta. Paciente do sexo masculino, 42 anos, queixava-se de forte sensibilidade e múltiplas Lesões Cervicais Não Cariosas na forma de cunha nos pré-molares superiores. O tratamento restaurador escolhido foi a técnica direta-indireta com resina composta realizado em três sessões distribuídas em confecção da peça em resina composta, cimentação e polimento final. A técnica direta-indireta surge como alternativa a técnica direta tradicional trazendo como benefícios um melhor contorno da restauração, uma vez que esta é acabada e polida fora da boca, além do controle do estresse de polimerização e menor desconforto ao paciente. A intervenção restauradora direta-indireta se mostra eficaz devido ao fato de conseguir contornar dificuldades encontradas em técnicas restauradoras diretas. (AU)

8.
Article in Chinese | WPRIM | ID: wpr-908767

ABSTRACT

Surface enhanced Raman spectroscopy (SERS) and confocal Raman microscopy are applied to investigate the structure and the molecular arrangement of sub-micron furosemide and polyvinylpyrrolidone(furosemide/PVP) particles produced by spray flash evaporation (SFE).Morphology,size and crystallinity of furosemide/PVP particles are analyzed by scanning electron microscopy (SEM) and X-ray powder diffraction (XRPD).Far-field Raman spectra and confocal far-field Raman maps of furosemide/PVP par-ticles are interpreted based on the far-field Raman spectra of pure furosemide and PVP precursors.Confocal far-field Raman microscopy shows that furosemide/PVP particles feature an intermixture of furosemide and PVP molecules at the sub-micron scale.SERS and surface-enhanced confocal Raman microscopy (SECoRM) are performed on furosemide,PVP and furosemide/PVP composite particles sputtered with silver (40 nm).SERS and SECoRM maps reveal that furosemide/PVP particle surfaces mainly consist of PVP molecules.The combination of surface and bulk sensitive analyses reveal that furosemide/PVP sub-micron particles are formed by the agglomeration of primary furosemide nano-crystals embedded in a thin PVP matrix.Interestingly,both far-field Raman microscopy and SECoRM provide molecular information on a statistically-relevant amount of sub-micron particles in a single microscopic map;this combination is thus an effective and time-saving tool for investigating organic sub-micron composites.

9.
Article in Chinese | WPRIM | ID: wpr-908756

ABSTRACT

There is a strong need to search for more effective compounds with bone anti-resorptive properties,which will cause fewer complications than commonly used bisphosphonates.To achieve this goal,it is necessary to search for new techniques to characterize the interactions between bone and drug.By studying their interaction with hydroxyapatite (HA),this study used three forms of ceramic materials,two of which are bone-stimulating materials,to assess the suitability of new active substances with anti-resorptive properties.In this study,three methods based on HA in loose form,polycaprolactone/HA (a polymer-ceramic materials containing HA),and polymer-ceramic monolithic in-needle extraction(MINE) device (a polymer inert skeleton),respectively,were used.The affinity of risedronate (a standard compound) and sixteen aminomethylenebisphosphonates (new compounds with potential anti-resorptive properties) to HA was defined according to the above-mentioned methods.Ten monolithic materials based on 2-hydroxyethyl methacrylate/ethylene dimethacrylate are prepared and studied,of which one was selected for more-detailed further research.Simulated body fluids containing bisphosphonates were passed through the MINE device.In this way,sorption-desorption of bisphosphonates was evaluated using this MINE device.The paper presents the advantages and disad-vantages of each technique and its suitability for assessing new active substances.All three methods allow for the selection of several compounds with potentially higher anti-resorptive properties than risedronate,in hope that it reflects their higher bone affinity and release ability.

10.
Annals of Dentistry ; : 52-60, 2021.
Article in English | WPRIM | ID: wpr-906583

ABSTRACT

@#This study aims to compare flexural strength and flexural modulus of different resin-based composites (RBCs) and to determine the impact of dietary solvents on flexural properties. Forty specimens (12x2x2mm) for each of two conventional (Aura Easy [AE]; Harmonize [HN]) and one bulk fill (Sonic Fill 2 [SF2]) were fabricated using customised plastic moulds. Specimens were light-cured, measured and randomly divided into four groups. The groups (n=10) were conditioned for 7 days at 37°C: in one of media: air (control), artificial saliva (SAGF), 0.02N citric acid and 50% ethanol–water solution. After conditioning, the specimens subjected to flexural testing. Two-way ANOVA and one-way ANOVA (post hoc: Tukey’s or Dunnett T3 tests) were used at =0.05. Significant differences in flexural properties were observed between materials and conditioning media. Flexural strength and modulus values ranged from 124.85MPa to 51.25MPa; and 6.76GPa to 4.03GPa, respectively. The highest flexural properties were obtained with conditioning in air. Exposure to aqueous solutions generally reduced flexural properties. In conclusion, the effect of dietary solvents on flexural properties were material and medium dependent. For functional longevity of restorations, patients’ alcohol intake should be considered during material selection. Dietary advice (reduce alcohol consumption) should be given to patients post operatively.

11.
Braz. dent. j ; 31(5): 532-539, Sept.-Oct. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132338

ABSTRACT

Abstract The aim was to evaluate the microtensile bond strength (mTBS) to dentin and interfacial stress in a class II cavity restored with bulk-fill or conventional composite resins and the margin interfaces. Vertical slot class II cavities in the mesial face, with the gingival end in dentin, were prepared in 72 third molars, being divided into groups (n=24): G1-Tetric N-Ceram; G2-Tetric N-Ceram Bulk-Fill; G3-SonicFill. Clearfil SE Bond adhesive system was used in all groups. Half of the teeth in each group (n=12) were submitted to thermo-mechanical cycling (TMC). Restored teeth (n=9) were cut perpendicular to obtain beams, which were submitted to a mTBS test in an EMIC machine. The cervical margins in dentin of the restored teeth (n=3) were assessed using SEM through epoxy resin replicas as well as the section of the restoration. Interfacial stresses after load application were calculated by 2D finite element analysis. The mTBS means-MPa followed by different letters represent statistical difference by ANOVA and Games-Howell's test (p<0.05): Without TMC: G1-15.68±6.10a; G2-10.08±5.21ab; G3-7.98±3.76b. With TMC: G1-9.70±5.52a; G2-5.79±1.42a; G3-4.37±1.87a. Interfacial stress (MPa) was 4.4 for SonicFill, 3.9 for Tetric N-Ceram, and 3.5 for Tetric N-Ceram Bulk-Fill. SEM images showed continuous margins for all composite resin restorations. It was possible to conclude that SonicFill obtained a slightly higher interfacial stress and lower bond strength to dentin in comparison with Tetric N-Ceram and Tetric N-Ceram Bulk-Fill. Continuous margin interfaces were obtained for Tetric N-Ceram, Tetric N-Ceram Bulk-Fill, and SonicFill. However, voids were observed in the SonicFill restorations.


Resumo O objetivo foi avaliar a resistência de união à microtração (RUμT) à dentina e o estresse interfacial em cavidades classe II restauradas com resina composta de incremento único ou convencional e as interfaces marginais. Cavidades classe II na face mesial, com margem gengival em dentina, foram confeccionadas em 72 terceiros molares, sendo divididos em grupos (n=24): Grupo 1-Tetric N-Ceram; Grupo 2- Tetric N-Ceram Bulk-Fill; Grupo 3- SonicFill. O Sistema adesivo Clearfil SE Bond foi usado em todos os grupos. Metade dos dentes de cada grupo (n=12) foram submetidos à ciclagem termo-mecânica (CTM). Os dentes restaurados (n=9) foram cortados perpendicularmente para obter palitos que foram submetidos ao teste de RµT na máquina-EMIC. As margens cervicais em dentina dos dentes restaurados (n=3) foram observados em microscopia eletrônica de varredura (MEV) por meio de réplicas em resina epoxy, assim como os cortes das restaurações. O estresse interfacial após a aplicação da carga foram calculadas por análise de elementos finitos 2D. As médias de RUμT-MPa seguidas de letras distintas apresentam diferença estatística de acordo com ANOVA e teste de Games-Howell (p<0,05): Antes da CTM: G1-15.68±6.10a; G2-10.08±5.21ab; G3-7.98±3.76b. Após CTM: G1-9.70±5.52a; G2-5.79±1.42a; G3-4.37±1.87a. O estresse interfacial (MPa) foi 4,4 para SonicFill, 3,9 para Tetric N-Ceram e 3,5 para Tetric N-Ceram Bulk-Fill. Imagens em MEV mostraram margens contínuas para todas as restaurações em resina composta. Foi possível concluir que o SonicFill obteve um estresse interfacial ligeiramente mais alto e menor resistência de união à dentina em comparação com o Tetric N-Ceram e o Tetric N-Ceram Bulk-Fill. Interfaces de margem contínua foram obtidas para Tetric N-Ceram, Tetric N-Ceram Bulk-Fill e SonicFill. Entretanto, espaços vazios foram observados nas restaurações do SonicFill.


Subject(s)
Humans , Dental Caries , Dental Restoration, Permanent , Materials Testing , Composite Resins , Dentin
12.
Int. j interdiscip. dent. (Print) ; 13(1): 17-20, abr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1114887

ABSTRACT

STATEMENT OF THE PROBLEM: The literature still lacks evidence regarding which polishing techniques have the ideal clinical outcomes for bulk-fill resin composites. PURPOSE: This study evaluated the surface gloss of two commercially available bulk-fill resin composites after different polishing procedures and characterized their micromorphology via scanning electron microscopy. MATERIAL AND METHODS: 80 bulk-fill compactable composite resin discs were created. The control group was left untreated, and remaining samples were subjected to different polishing techniques. Gloss units were measured and surface morphology of disc samples was assessed. The Tukey post-hoc test was used to identify any differences. RESULTS: Statistically significant differences were found between the different polishing systems applied to Filtek BulkFill Posterior and Tetric N Bulk-Fill. No differences were found when the same polishing system was applied for both resins. The highest gloss values were obtained in the control group and the ENA Shiny system; the lowest were obtained with SofLex XT and Soflex Spiral Wheels for the bulk-fill composite resins studied. CONCLUSIONS. Diamond pastes have the highest gloss behavior, followed by diamond rubber points. The systems with aluminum oxide discs present the lower gloss behavior. SEM images provided useful evidence, and future studies should include an evaluation over time.


Subject(s)
Composite Resins/chemistry , Dental Polishing/methods , Surface Properties , Materials Testing
13.
Dental press j. orthod. (Impr.) ; 25(2): 52-60, Mar.-Apr. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1133651

ABSTRACT

ABSTRACT Introduction: Plaque accumulation can cause white spot lesions. Adding nanoparticles to composites can be effective in reducing the number and function of microorganisms. Objective: The aim of this study was to evaluate the antibacterial effects of orthodontic composites containing different nanoparticles on Streptococcus mutans at different times. Methods: Hydroxyapatite, titanium oxides, zinc oxide, copper oxide and silver oxide nanoparticles were prepared at 0.5% and 1% weight concentrations. Accordingly, ten study groups and one control group were obtained. Then, 26 composite discs were prepared from each group. Strain of Streptococcus mutans was cultured, and colonies of Streptococcus mutans were counted. Further bacterial culture was swapped onto enriched Mueller-Hinton agar. The composites were placed on the culture medium, and after incubation the diameter of growth inhibition was measured. To investigate the long-term effect of nanoparticles, the colonies were counted at days 3, 15 and 30. Results: The results showed that 1% copper oxide and 1% silver oxide significantly reduced the number of bacteria (p< 0.05), but there was no significant difference between the other groups and control group (p> 0.05). At day three, there was a significant difference between control group and 0.5% silver oxide, 1% silver oxide and 1% copper oxide groups (p< 0.05). However, colonies had grown in all groups at day 30 but showed no significant difference with control group (p> 0.05). Conclusion: Addition of 1% copper oxide and 1% silver oxide has short-term antibacterial effects, so the clinical use of these nanoparticles cannot be justified.


RESUMO Introdução: O acúmulo de placa bacteriana pode causar lesões de mancha branca. A adição de nanopartículas nas resinas ortodônticas pode ser eficaz para reduzir o número e a função dos microrganismos. Objetivo: O objetivo do presente estudo foi avaliar os efeitos antibacterianos contra o Streptococcus mutans, em diferentes intervalos de tempo, de resinas ortodônticas contendo diferentes tipos de nanopartículas. Métodos: Foram criados dez grupos experimentais e um grupo controle contendo nanopartículas de hidroxiapatita, óxido de titânio, óxido de zinco, óxido de cobre e óxido de prata em concentrações de 0,5% e 1%. Em seguida, foram preparados 26 discos de resina para cada grupo. Colônias de Streptococcus mutans foram cultivadas e contadas. Posteriormente, as culturas bacterianas foram colocadas em solução de ágar Mueller-Hinton. Os discos de resina foram colocados no meio de cultura e, depois da incubação, mediu-se o diâmetro de inibição do crescimento. Para avaliar os efeitos em longo prazo das nanopartículas, as colônias foram analisadas após 3, 15 e 30 dias. Resultados: Os resultados mostraram que o óxido de cobre a 1% e o óxido de prata a 1% reduziram significativamente o número de bactérias (p< 0,05), mas não houve diferença estatisticamente significativa entre os outros grupos e o grupo controle (p> 0,05). Após 3 dias, houve uma diferença significativa entre o grupo controle e os grupos óxido de prata a 0,5%, óxido de prata a 1% e óxido de cobre a 1% (p< 0,05). Porém, após 30 dias, as colônias haviam crescido em todos os grupos, sem diferença com o grupo controle (p> 0,05). Conclusão: A adição de óxido de cobre a 1% e óxido de prata a 1% apresenta efeitos antibacterianos apenas no curto prazo; portanto, o uso clínico dessas nanopartículas não se justifica.


Subject(s)
Humans , Dental Plaque , Nanoparticles , Streptococcus mutans , Anti-Bacterial Agents
14.
Braz. dent. j ; 31(1): 69-77, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1089271

ABSTRACT

Abstract The objective was to evaluate the color stability of ceramic veneers luted with resin cements and pre-heated composite resins (60oC) for 12 months, and determine the degree of conversion (DC) of the luting agents. Two resin cements (AllCem Veneer, light-cured (LRC) and AllCem, dual-cured (DRC)] and three composite resins [Z100 (MNCR-minifilled), Herculite Classic (MHCR-micro-hybrid) and Durafill (MCCR-microfilled)] were used for cementing 0.8-mm-thick lithium-silicate glass-ceramic laminates (Suprinity, shade B2-HT, Vita) on bovine enamel (n=10). The specimens were stored at 37oC in distilled water. CIELab parameters were determined at 24h after luting (baseline), 7, 30, 90, 180 days and 12 months. Three specimens were prepared for DC evaluation, performed by micro-Raman spectroscopy. Data were analyzed by ANOVA and Tukey's test (a=5%). For ΔEab and ΔE00, there were significant differences for luting material (p<0.001), time (p<0.001), and double interaction (p<0.001). The groups cemented with MHCR (1 year), MCCR (90 days and 1 year) and MCCR-PH (1 year) were the ones with ΔE values greater than the acceptability threshold. All other groups maintained their ΔE lower than the acceptability threshold after 1 year in distilled water. Regarding DC, there were no significant differences (p=0.127) among the materials. Non-significant negative correlations were observed between the mean ΔEab and DC (R=-0.65) and ΔE00 and DC (R=-0.64). A significant positive correlation was observed mean ΔEab and ΔE00 (R=0.99). It was concluded that the different luting agents influenced the final color of the restorations. The heating of the composite resins did not affect their DC.


Resumo O objetivo foi avaliar a estabilidade de cor de laminados cerâmicos de fina espessura, após a cimentação com cimentos resinosos e resinas compostas em temperatura ambiente e aquecida (60oC), durante 12 meses; bem como determinar o grau de conversão dos diferentes materiais para cimentação. Foram utilizados dois cimentos resinosos [AllCem Veneer, cimento resinoso fotoativado (LRC) e AllCem, cimento resinoso dual (DRC)] e três resinas compostas [Z100 (MNCR - resina composta de partículas finas), Herculite Classic (MHCR - resina composta micro-híbrida) e Durafill (MCCR - resina composta microparticulada)] para cimentação de laminados cerâmicos a base de silicato de lítio (Suprinity, cor B2-HT, Vita Zahnfabrik) com 0,8 mm de espessura, sobre esmalte bovino. Oitenta espécimes foram distribuídos aleatoriamente em 8 grupos de acordo com o material para cimentante (n=10). Os espécimes foram armazenados a 37oC em água destilada. Os parâmetros do CIELab foram determinados 24h após a cimentação (baseline), 7, 30, 90, 180 dias e 12 meses. Outros três espécimes foram preparados para avaliação de grau de conversão, realizada por espectroscopia micro-Raman. Os dados foram analisados por ANOVA e teste de Tukey (a=5%). Para ΔEab e ΔE00, houve diferenças estatisticamente significantes para o material de cimentação (p<0,001), tempo (p<0,001) e interação dupla (p<0,001). Os grupos cimentados com o MHCR (1 ano), MCCR (90 dias e 1 ano) e MCCR-PH (1 ano) foram os únicos com valores de ΔE maiores que o limite de aceitabilidade. Todos os demais grupos mantiveram seu ΔE menor que o limite de aceitabilidade ao final de 1 ano de armazenamento em água destilada. Em relação ao grau de conversão, não foram observadas diferenças estatisticamente significantes entre os materiais para cimentação avaliados (p=0,127). O grau de conversão variou entre 64,0% (MNCR-PH) e 85,1% (DRC). Correlações negativas moderadas a fortes não significativas foram observadas entre a média ΔEab e grau de conversão (R=-0,65) e ΔE00 e grau de conversão (R=-0,64). Observou-se uma correlação positiva forte significativa nos valores médios de ΔEab e ΔE00 (R=0,99). Pode-se concluir que os diferentes agentes cimentantes utilizados na cimentação de laminados cerâmicos de espessura fina influenciaram na cor final das restaurações. O aquecimento das resinas compostas não implicou em alteração do grau de conversão.


Subject(s)
Animals , Ceramics , Resin Cements , Materials Testing , Cattle , Follow-Up Studies , Color , Composite Resins , Dental Porcelain , Dental Veneers
15.
Braz. dent. sci ; 23(2): 1-6, 2020. tab
Article in English | LILACS, BBO | ID: biblio-1096283

ABSTRACT

Objective: Degree of Conversion (DC) of ResinBased composites (RBCs) is a concern and is affected by different factors. This study was conducted to evaluate the effect of different thicknesses and storage times on DC of bulk-fill and universal RBCs using the FTIR method. Material and Methods: For each of dental composite (Tetric N- Ceram Bulk Fill and Tetric N Ceram), 28 samples were prepared (14 samples with 2 mm height and 14 samples with 4 mm height). One and seven days (1d and 7d) after storage in an incubator at 37 ˚C, DC was measured and recorded using a FTIR device. Data were analyzed using t-test and ThreeWay ANOVA and Tukey Post-Hoc Test. P < 0.05 was considered statistically significant. Results: DC of Bulk-fill composite is greater than universal composite. DC at 2 mm thickness is more than 4 mm. Unlike universal composite, 7d DC of Bulkfill composite is greater than 1d. Of course, none of these differences are statistically significant (P-value > 0.05). Conclusion: Considering the limitation of this study, since no difference was found between DC of 1d and 7d, 1d DC is sufficient for clinical procedures, such as polishing, and the laboratory tests. (AU)


Objetivo: O grau de conversão (DC) de compósitos à base de resina (RBCs) é um assunto que merece cuidado e é afetado por diferentes fatores. Este estudo foi conduzido para avaliar o efeito de diferentes espessuras e tempos de armazenamento no DC de compósitos Bulk-fill e compósitos universais usando o método FTIR. Material e Métodos: Para cada compósito dentário (Tetric N-Ceram Bulk Fill e Tetric N Ceram), foram preparadas 28 amostras (14 amostras com 2 mm de altura e 14 amostras com 4 mm de altura). Um e sete dias (1d e 7d) após o armazenamento em uma incubadora a 37 ° C, o DC foi mensurado e registrado usando um dispositivo FTIR. Os dados foram analisados por meio do teste t, ANOVA três fatores e teste PostHoc de Tukey. P 0,05). Conclusão: Considerando a limitação deste estudo, uma vez que não foi encontrada diferença entre as DC de 1d e 7d, a 1d DC é suficiente para procedimentos clínicos, como polimento e testes laboratoriais. (AU)


Subject(s)
Spectroscopy, Fourier Transform Infrared , Composite Resins
16.
Odovtos (En línea) ; 21(3): 17-31, Sep.-Dec. 2019. graf
Article in Spanish | LILACS, BBO | ID: biblio-1091489

ABSTRACT

RESUMEN La preservación de tejido dental sano contribuye a la práctica de una Odontología conservadora, permitiendo la aplicación de los principios biológicos y mecánicos de una forma más predecible. Las preparaciones cavitarias mínimamente invasivas son el complemento de la correcta selección de materiales adhesivos y de resina compuesta. La correcta aplicación de un protocolo adhesivo nos proporcionará resultados estéticos imperceptibles y un longevo desempeño clínico.


ABSTRACT The preservation of healthy dental structures contributes to the practice of a conservative dentistry. This concept involves the implementation of biological and mechanical principles in a more predictable manner. Minimally invasive cavity preparations are the complement to the selection of adhesive and composite resin materials. The correct application of an adhesive protocol will provide imperceptible aesthetic restorations and adequate clinical performance.


Subject(s)
Humans , Female , Adult , Dentin-Bonding Agents/therapeutic use , Composite Resins/therapeutic use , Dental Enamel Hypoplasia/surgery , Dental Restoration, Permanent/methods
17.
Braz. dent. j ; 30(6): 592-598, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1055449

ABSTRACT

Abstract This study aimed to evaluate the polymerization properties of bulk-fill materials (low and high-viscosity) by using high-intensity continuous light and intermittent photo-activation in terms of polymerization shrinkage stress and degree of conversion (DC). The following Bulk-fill and Conventional nanofilled resin composites were evaluated: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) and Filtek Bulk Fill Posterior (3M/ESPE). A LED device (DB 685, Dabi Atlante) was used for both protocols: continuous uniform and intermittent photo-activation (light-on and light-off cycles) with identical radiant exposure (14 J/cm2). The polymerization shrinkage stress (n=6) was evaluated by inserting a single increment of 12 mm3 between two stainless steel plates (6×2 mm) adapted to a Universal Testing Machine (UTM), at different times. Measurements were recorded after photo-activation. The degree of conversion was evaluated by Fourier transformed infrared spectroscope (FTIR) with an attenuated total reflectance (ATR) accessory (n=5). Data were analyzed by three-way ANOVA and Tukey's HSD (α=0.05) tests. Bulk Fill Posterior presented higher shrinkage stress values when photo-activated with the intermittent technique (p<0.05). The intermittent photo-activation increased the degree of conversion for the low-viscosity bulk-fills (p<0.05). Therefore, the use of modulated photo-activation (intermittent) must be indicated with caution since its use can influence the shrinkage stress and degree of conversion of composites, which varies according to the resin formulations.


Resumo O presente estudo teve como objetivo avaliar as propriedades de polimerização de materiais bulk-fill (baixa e alta viscosidade) utilizando luz contínua de alta intensidade e fotoativação intermitente em relação ao estresse de contração de polimerização e grau de conversão (DC). As seguintes resinas compostas Bulk-fill e nanohíbridas convencionais foram avaliadas: Filtek Z350XT Flow (3M/ESPE), SureFil SDR Flow (Dentsply), Filtek Bulk Fill Flow (3M/ESPE), Filtek Z350XT (3M/ESPE) e Filtek Bulk Fill Posterior (3M/ESPE). Um dispositivo de LED (DB 685, Dabi Atlante) foi utilizado nos dois protocolos: fotoativação contínua e intermitente contínua (ciclos de liga e desliga) com exposição idêntica (14 J/cm2). A tensão de contração de polimerização (n=6) foi avaliada através da inserção de um incremento único de 12 mm3 entre duas placas de aço inoxidável (6×2 mm) adaptadas a uma Máquina de Ensaio Universal (UTM), em tempos diferentes. As medições foram registradas após a fotoativação. O grau de conversão foi avaliado por FTIR-ATR (n=5). Os dados foram analisados ​​pelos testes ANOVA a três fatores e teste de Tukey (α=0,05). A resina Bulk Fill Posterior apresentou maiores valores de tensão de contração quando fotoativadas com a técnica intermitente (p<0,05). A fotoativação intermitente aumentou o grau de conversão nas resinas bulk-fill de baixa viscosidade (p<0,05). Portanto, o uso de fotoativação modulada (intermitente) deve ser indicado com cautela, uma vez que seu uso pode influenciar a tensão de contração e o grau de conversão dos compósitos, o que varia de acordo com as formulações da resina.


Subject(s)
Materials Testing , Composite Resins , Viscosity , Polymerization
18.
Rev. Ciênc. Méd. Biol. (Impr.) ; 18(2): 239-248, nov 07, 2019. fig, ilus
Article in Portuguese | LILACS | ID: biblio-1291689

ABSTRACT

Introdução: associadas à composição química, as propriedades físicas dos biomateriais como formato, dimensões e porosidade, são fatores que influenciam na biocompatibilidade, biodegradabilidade e nos potenciais osteoindutivo e osteocondutores. Objetivo: identificar modificações físicas no formato, dimensões e porosidade de um biomaterial com nova composição de wollastonita e beta fosfato tricálcico, implantado em defeitos ósseos críticos em calvária de ratos. Metodologia: trata-se de um estudo exploratório, com um biomaterial compósito, antes e após a sua implantação in vivo. Utilizou-se explantes cirúrgicos de calvárias de ratos que receberam implantes em defeito ósseo crítico. Os animais foram distribuídos em 3 grupos experimentais aleatoriamente, compostos por 5 animais cada, e avaliados com 15, 45 e 120 dias. Os grupos foram denominados: G0-biomaterial; GI-15 dias; GII-45 dias; e, GIII-120 dias. As amostras foram micrografadas em microscópio eletrônico de varredura, com diferentes magnificações. Utilizouse o software livre ImageJ para processamento das imagens e análise das partículas e poros. Resultados: a distribuição espacial do biomaterial promoveu preenchimento completo do defeito ósseo crítico. Micrografias com diferentes magnificações permitiu identificar modificações na área de contato entre grânulos, diminuição dos poros intergranular, aumento da área ocupada pelos poros e diminuição das partículas nos grânulos. Nos grupos GII e GIII, identificou-se formação de componentes orgânicos na superfície do implante. Conclusão: houve modificações físicas no formato, dimensões horizontais, distribuição espacial e porosidade da superfície dos grânulos do biomaterial, relacionadas com a biodegradabilidade e o potencial osteoindutivo e osteocondutor do biomaterial.


Introduction: associated with the chemical composition, physical properties of biomaterials related to their format, dimensions and porosity, are factors that influence on biocompatibility, biodegradability and osteoinductive and osteoconductive potential. Objective: identify physical changes in the format, dimensions and porosity of biomaterial with new composition of wollastonite and beta tricalcium phosphate, implanted in critical bone defects in calvaria of rats. Methodology: this is an exploratory study, with a composite biomaterial before and after its implantation in vivo. Used surgical explants of rat calvarium that received biomaterial implants into the critical bone defect. The animals were divided into 3 experimental groups of random distribution, composed of 5 animals each, and evaluated for 15, 45 and 120 days. The groups were named: G0-Biomaterial; GI-15 days; GII-45 days; and, GIII-120 days. The samples were studied by micrography in scanning electronic microscope with different magnifications. It was used the free software ImageJ to image processing and particles and pores analysis. Results: the spatial distribution of the biomaterial promoted full filling of the critical bone defect. Micrographs with different magnifications allowed to identification of modifications in the area of contact between granules, decrease of the intergranular pores, increase of the area occupied by the pores and decrease of the particles in the granules. In GII, and GIII groups, it was identified formation of organic components on the surface of the implant. Conclusion: there were physical modifications in the format, horizontal dimensions, spatial distribution and porosity of the biomaterial, related to the biodegradability and the osteoinductive and osteoconductive potential of the biomaterial.


Subject(s)
Bone Regeneration
19.
Rev. colomb. ciencias quim. farm ; 48(2): 455-466, mayo-ago. 2019. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1092956

ABSTRACT

RESUMO Por meio de uma análise teórica, foi avaliado o desempenho do compósito do oxihidróxido do vanádio trivalente com o polímero do corante alaranjado da acridina, na detecção eletroquímica do fármaco antiparquinsônico entacapona. O processo eletroanalítico é baseado na eletrorredução do fármaco mencionado. Do desenvolvimento e da análise do modelo matemático correspondente, mediante a teoria de estabilidade linear e anáise de bifurcações, foi possível concluir que o compósito pode ser um modificador eficiente para a determinação da entacapona. Os comportamentos oscilatórios e monotônico, neste sistema, também são passíveis de realizar.


SUMMARY By means of a theoretical analysis, the function of trivalent vanadium oxyhydroxyde composite with the polymer of the acridine orange dye for electrochemical evaluation of entacapone antiparkinsonic drug has been evaluated. The electroanalytical process is based on the electrochemical reduction of the mentioned drug. From development and analysis of the correspondent mathematical model by means of linear stability theory and bifurcation analysis, it was possible to conclude that the composite is an efficient electrode modifier for entacapone determination. The oscillatory and monotonic instabilities in this system are also capable to realize.

20.
ROBRAC ; 28(85): 45-52, abr./jun. 2019. Ilus, Tab
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1049233

ABSTRACT

Objetivo: Avaliar rugosidade superficial (RS), estabilidade de cor (EC) e morfologia de superfície (MS) de um compósito nanoparticulado após diferentes protocolos de acabamento/ polimento com ou sem irrigação. Material e métodos: Cem espécimes foram confeccionados e divididos em 10 grupos (n=10) conforme protocolo de acabamento/polimento: Tira de poliéster; discos abrasivos (DA); DA+espirais (DAE); DA+multi- -laminada+espirais (DAME); espirais (E); e nenhum polimento. Protocolos com DA, DAE, DAME, e E foram realizados a seco e com irrigação. Após acabamento/polimento, os espécimes foram armazenados em água destilada à 37°C. Durante 14 dias, cinco espécimes de cada grupo foram imersos em café por 5min/dia. A EC foi analisada com Espectrofotômetro (CIEL*a*b*) 0, 7 e 14 dias após armazenamento em água ou imersão em café. A RS foi analisada com Rugosímetro (parâmetro Ra) e MS foi analisada com Microscopia Eletrônica de Varredura (MEV). ANOVA, Tukey e Teste T foram realizados para comparações entre os grupos (α=0,05). Resultados: A irrigação promoveu maior EC nos protocolos DAE e E. Os diferentes protocolos promoveram variação de cor semelhante após 14 dias de armazenamento em água. O protocolo E a seco promoveu os maiores valores RS, sendo inferior ao grupo DAME, que promoveu menor rugosidade e foi semelhante aos demais protocolos. Para DAME e E a irrigação foi significativa para diminuir a rugosidade. Na análise por MEV, E com irrigação apresentaram maior lisura superficial. Conclusão: A irrigação durante acabamento/polimento influencia na EC, RS e MS de compósitos. Os protocolos de acabamento/ polimento DAME e E com irrigação foram mais efetivos.


Aim: to evaluate the surface roughness (SR), color stability (CE) and surface morphology (SM) of a nanofilled composite resin exposed to different finishing/ polishing protocols with or without irrigation. Material and methods: One hundred specimens were prepared and divided into 10 groups (n = 10) according to the finishing/polishing protocol: positive control; abrasive discs (AD); AD + spirals (ADS); AD + multi-laminated + spirals (ADMS); spirals (S); and none. Protocols with AD; ADS; ADMS and S were performed to dry or with irrigation. After finishing/ polishing, the samples were stored in distilled water at 37 ° C. For 14 days, five samples of each group were immersed in coffee for 5min/day. The other samples have been stored in water. The CE of the samples was analyzed with Spectrophotometer (CIEL * a * b *) 0, 7 and 14 days after storage in water or coffee. The SR was analyzed with the Rugosimeter and the SM was analyzed with Scanning Electron Microscopy (SEM). ANOVA, Tukey and T-test were performed for comparisons between the groups (α=0,05). Results: Irrigation offered higher EC in the ADS and S groups. The benefits of color variation are after 14 days. The use of dry spirals promoted the highest SR values, being lower in the ADMS group, which promoted less roughness and was similar to the other protocols. For ADMS and S the irrigation was significant to decrease the roughness. Analysis by MEV, spirals with irrigation greater superficial smoothness. Conclusion: Irrigation during finishing/polishing influences the CS, SR and SM of composites. The finishing/polishing protocols with ADMS and S with irrigation were more effective.

SELECTION OF CITATIONS