ABSTRACT
BACKGROUND:The proximal femoral nail antirotation is the preferred treatment for reverse osteoporotic intertrochanteric fractures.Bone cement enhancement can reduce the probability of proximal femoral nail antirotation cut-out and cut-through,but there are no relevant biomechanical studies demonstrating the effect of bone cement content and location on the stress and displacement of the fracture end. OBJECTIVE:To investigate the effects of different contents and locations of bone cement in cement-reinforced proximal femoral nail antirotation on stress,strain,and displacement of reverse osteoporotic femoral intertrochanteric fractures in the elderly by finite element analysis. METHODS:A healthy adult female right femur model was extracted by Mimics software and smoothed in Geometric software.Five types of internal fixation methods of proximal femoral nail antirotation(cementless,cephalic spherical 1 mL,cephalic spherical 2 mL,cephalic spherical 3.4 mL,and cylindrical 5 mL around spiral blade)and femoral intertrochanteric fracture(AO subtype 31-A3.1 type)model were established in Solidworks software.After assembly,the total stress distribution,peak stress and displacement of the five models of implants with the femur were compared in Ansys software. RESULTS AND CONCLUSION:(1)The peak stresses of proximal femoral nail antirotation with head-end spherical 1 mL,head-end spherical 2 mL,head-end spherical 3.4 mL,and cylindrical 5 mL enhanced proximal femoral nail antirotation around the spiral blade respectively were 571.07 MPa(located at the junction of the spiral blade and the main nail),495.45 MPa(located at the junction of the spiral blade and the main nail),467.20 MPa(located at the junction of the main nail and the distal screw connection),642.70 MPa(located at the junction of the main nail and distal screw connection),and 458.58 MPa(located at the junction of the spiral blade and the main nail).(2)The maximum displacements of proximal femoral nail antirotation with head end sphere 1 mL,head end sphere 2 mL,head end sphere 3.4 mL,and with cylindrical 5 mL enhancement around the spiral blade were 9.260 5,7.589 1,7.316 8,6.790 7,and 6.615 7 mm,respectively,all of which were located at the proximal end of the femoral head.(3)These findings revealed that for reverse femoral intertrochanteric fractures treated with proximal femoral nail antirotation,the bone cement enhancement had significant mechanical stability compared with no enhancement,and the enhancement of the spiral blade 5 mL around the perimeter was the best,which is more preferable for aged unstable intertrochanteric fractures.
ABSTRACT
BACKGROUND:For elderly patients with traumatic hip fractures,the related factors of prognosis are very complex,and the integrity of the lateral wall is one of the influencing factors.It is of important clinical value to understand the effect of lateral wall injury on the prognosis of femoral intertrochanteric fracture. OBJECTIVE:To evaluate the relationship between the integrity of the lateral wall and hip functional recovery and other outcomes in patients with femoral intertrochanteric fractures. METHODS:Totally 82 patients with femoral intertrochanteric fractures were screened and all patients received proximal femoral nail antirotation fixation.According to the thickness of the lateral wall,the patients were divided into the lateral wall intact group(n=31)and lateral wall risk group(n=51).The perioperative indexes,weight-bearing time,fracture healing time,hip joint function and range of motion,postoperative pain and complications were compared between the two groups. RESULTS AND CONCLUSION:(1)The time of hospitalization and the number of fluoroscopies during operation in the lateral wall intact group were significantly lower than those in the lateral wall risk group(P<0.05),but there was no significant difference in other perioperative indexes.(2)Both groups were able to get down to the ground early after surgery and finally complete weight-bearing,but in the lateral wall risk group,the time of fracture healing was longer;the time of complete weight-bearing was significantly delayed;the Harris score of the last follow-up was lower;the range of motion of hip extension and flexion and neck trunk angle on the affected side were smaller(P<0.05).(3)There was no significant difference in the incidence of postoperative complications between the two groups,but the overall incidence of complications in the lateral wall intact group was significantly lower(P<0.05).(4)In summary,after internal fixation of proximal femoral nail antirotation,patients with the intact lateral wall had a relatively better prognosis than those with risk lateral wall.
ABSTRACT
BACKGROUND:Patients with femoral intertrochanteric fracture may have nutritional risks during proximal femoral nail anti-rotation surgery,and a clinical predictive model is established based on nutritional assessment tools. OBJECTIVE:To establish the nomogram of the nutritional risk prediction model for patients with intertrochanteric fracture after proximal femoral nail anti-rotation fixation and evaluate the accuracy of the model. METHODS:From December 2018 to July 2022,patients with femoral intertrochanteric fractures who underwent proximal femoral nail anti-rotation fixation in First Department of Orthopedics,Second Affiliated Hospital of Baotou Medical College were selected as the study subjects.The nutritional risk status of patients was assessed using nutritional risk screening 2002.Logistic regression was used to build the model.The receiver operating characteristic curve,Calibration plot calibration curve,and Hosmer-Lemeshow goodness-of-fit test were used to evaluate the discrimination,calibration and clinical applicability of the prediction model.The model was visualized using Nomogram diagrams. RESULTS AND CONCLUSION:(1)Seventy-six patients were included according to the inclusion criteria.The incidence of nutritional risk was 80%after being assessed using nutritional risk screening 2002.(2)The results of Logistic regression analysis demonstrated that age≥77 years old,body mass index<22.80 kg/m2,upper arm circumference<25.01 cm,hemoglobin<98.51 g/L,albumin<31.61 g/L,and prealbumin<138.56 g/L were all independent risk factors for nutritional risk(P<0.05).(3)The area under the receiver operating characteristic curve was 0.919(95%CI:0.843-0.994).(4)The results of the Hosmer-Lemeshow goodness-of-fit test displayed that nutritional risk prediction value was high.(5)It is concluded that the nutritional risk assessment model constructed in this study has a good degree of discrimination and calibration,and has a certain predictive ability,which can be used as a reference tool for nutritional risk assessment of patients after proximal femoral nail anti-rotation fixation.
ABSTRACT
BACKGROUND:There is controversy regarding the need for marrow reaming in intertrochanteric fractures of the femur.Some believe that unreaming shortens operative time,reduces bleeding,and decreases intraoperative risk in elderly patients,but there is no basis for whether this move reduces the effectiveness of intramedullary nail support.Others believe that reaming allows for the selection of thicker diameter intramedullary nails for better mechanical support,but basic studies have shown that this approach carries risks such as fat embolism and destruction of bone(especially in elderly patients with osteoporosis). OBJECTIVE:To analyze the mechanical distribution characteristics of reamed and unreamed proximal femoral nail antirotation-Ⅱ in the treatment of type 31-A3 intertrochanteric fractures by finite element analysis. METHODS:A healthy volunteer was included,and CT scans of his femur were obtained in DICOM format,and the files were sequentially imported into Mimics,Geomagic Wrap,SolidWorks,Hypermesh,and Ansys software for processing.The A3.1,A3.2,and A3.3 intertrochanteric fracture models were obtained and assembled with 9 mm,11 mm diameter,and 170 mm length intramedullary nails,respectively,followed by assigning material properties,setting the interaction relationship of each contact surface and defining the load and boundary conditions,and then solved.The femoral stress distribution,internal fixation stress distribution,femoral displacement,and internal fixation displacement were observed in different models. RESULTS AND CONCLUSION:(1)The femoral stress was less than that of unreamed intramedullary nail fixation for each type of fracture,and the maximum stress value of the femur for A3.3 fracture was greater than that of A3.1 and A3.2.(2)The internal fixation stress was greater than that of unreamed intramedullary nail fixation for each type of fracture,and the maximum stress value of internal fixation for A3.3 fracture was greater than that of A3.1.(3)Reamed versus unreamed intramedullary nailing has less effect on femoral and internal fixation displacement and more effect on stress.(4)It is indicated that the use of reamed intramedullary nail fixation results in a reduction in femoral stress,an increase in the stress borne by the internal fixation as a whole,and a reduction in the stress borne by the distal locking nail.The use of reamed intramedullary nail fixation may provide better treatment results compared to unreamed intramedullary nail fixation.
ABSTRACT
BACKGROUND:Intertrochanteric fracture of femur often occurs in the elderly,and there will be a large amount of hidden blood loss after surgery.Reducing hidden blood loss can decrease complications and hospital stay. OBJECTIVE:To evaluate the effect of prolonged use of tranexamic acid on hidden blood loss after proximal femoral nail antirotation implantation in senile intertrochanteric fractures. METHODS:From January 2022 to May 2023,62 elderly admitted patients with intertrochanteric fracture of femur were selected from Zigong Fourth People's Hospital.All of them were treated with proximal femoral nail antirotation implantation after closed reduction on the traction bed.According to the use time of tranexamic acid,they were divided into two groups.In the control group(n=38),1 g tranexamic acid was given intravenically 15-30 minutes before incision,and 1 g was added 3 hours later.Based on the control group,the trial group(n=24)was given 1 g tranexamic acid intravenously once for 12 hours on the first day after surgery.Blood routine examinations were performed before surgery,on the day after surgery,and on the first,third and fifth days after surgery.Hemoglobin and hematocrit were counted.The theoretical total blood loss was calculated by Cross equation,and the incidence of complications in the two groups was recorded. RESULTS AND CONCLUSION:(1)Through statistical analysis,there was no significant difference in the amount of dominant blood loss between the two groups(P>0.05).(2)The number of grams of hemoglobin decreased,total blood loss and hidden blood loss in the trial group during perioperative period were lower than those in the control group,and the differences were statistically significant(P<0.05).(3)The hemoglobin values of the trial group on day 3 after surgery,and the hematocrit values on days 1 and 3 after surgery were higher than those of the control group,with statistical significance(P<0.05).(4)The hemoglobin and platelet count showed a downward trend after surgery,and the hemoglobin value was the lowest value on day 3,and the platelet value was the lowest value on day 1 after surgery,and then began to rise in both groups.(5)There was no significant difference in postoperative complications between the two groups(P>0.05).(6)The results show that prolonging use of tranatemic acid can effectively reduce the hidden blood loss in the treatment of femoral intertrochanteric fracture with proximal anti-rotation intramedullary nail,and does not increase the risk of complications.
ABSTRACT
Objective To analyze the incidence and risk factors of hypothermia in elderly patients with malnutrition during proximal femoral nail antirotation(PFNA)internal fixation under general anesthesia.Methods A total of 139 elderly patients underwent PFNA internal fixation under general anesthesia were selected,and the nutritional status scores 1 day before surgery ranged from 0 to 11 points.Univariate and multivariate Logistic binary regression analysis was performed to analyze the related factors that may lead to intraoperative hypothermia.Results Among 139 elderly patients with preoperative nutritional scores of 0 to 11 points,79 cases(56.83%)developed intraoperative hypothermia.The results of univariate and multivariate Logistic binary regression analysis suggested that age≥75 years old,mini nutritional assessment short form(MNA-SF)nutritional score 0 to 7 points,BMI<18.5 kg/m2,duration of general anesthesia≥2 hours,intraoperative flushing fluid volume≥1 000 mL and intraoperative fluid volume≥1 000 mL were the risk factors for the occurrence of intraoperative hypothermia in elderly patients(OR>1,P<0.05).The use of warm blanket insulation was the protective factor against the occurrence of intraoperative hypothermia(OR<1,P<0.05).Conclusion The incidence of intraoperative hypothermia during PFNA internal fixation under general anesthesia in elderly patients with mainutrition before operation is high,and patients with poor nutritional status are more likely to develop intraoperative hypothermia.Patients with older age,poor nutritional status,lower BMI,longer duration of general anesthesia,and more intraoperative flushing fluid volume and intraoperative fluid volume are likely to lead to intraoperative hypothermia.The use of warm blanket can reduce the incidence of intraoperative hypothermia.
ABSTRACT
Objective To investigate the efficacies of proximal femoral nail anti-rotation(PFNA)internal fixation in traction bed supine position and non-traction bed lateral position in the treatment of elderly unstable femoral intertrochanteric fractures.Methods The clinical data of patients with unstable femoral intertrochanteric fractures treated with PFNA internal fixation in our hospital were retrospec-tively analyzed,41 patients received treatment in traction bed supine position were included in the supine position group,and 55 patients treated received treatment in non-traction bed lateral position were included in the lateral position group.The perioperative related indicators,surgical reduction,hip Harris score,and incidence of complications in the two groups were analyzed.Results The operation time and incision length of patients in the lateral position group were shorter than those in the supine position group,and the intraoperative blood loss and fluoroscopy times were less than those in the supine position group,with statistically significant differences(P<0.05).There was no significant difference in the anesthesia mode,blood transfusion or hospital stay of patients between the two groups(P>0.05).There was no significant difference in the incidence of postoperative complications of patients between the two groups(P>0.05).There was no significant difference in neck-shaft angle,tip-apex distance or hip Harris score of patients between the two groups(P>0.05).Conclusion PFNA internal fixation in traction bed supine position and non-traction bed lateral position have the same effect in the treatment of elderly unstable femoral intertrochanteric fractures,while the non-traction bed lateral position for treatment has more advantages in shortening operation time,decreasing intraoperative blood loss,and reducing radiation exposure.
ABSTRACT
Objective:To compare the short-term effects of proximal femoral bionic nail (PFBN) and proximal femoral nail antirotation (PFNA) in the treatment of intertrochanteric fracture.Methods:Retrospectively analyzed were the data of 56 patients with intertrochanteric fracture of the femur who had been admitted to Department of Orthopedic Trauma, The People's Hospital of Juye County and Trauma Center, Central Hospital Affiliated to The First Medical University of Shandong from August 2020 to April 2022. The patients were divided into 2 even groups according to their internal fixation methods ( n=28). In the PFBN fixation group, there were 12 males and 16 females with an age of (70.4±7.8) years; by AO classification, there were 4 cases of type 31-A1, 16 cases of type 31-A2, and 8 cases of type 31-A3. In the PFNA fixation group, there were 10 males and 18 females with an age of (73.0±8.9) years; by AO classification, there were 2 cases of type 31-A1, 16 cases of type 31-A2, and 10 cases of type 31-A3. The operation time, intraoperative blood loss, fracture reduction, fracture healing time, Harris hip score, and complications were compared between the 2 groups. Results:There was no statistically significant difference between the 2 groups in the preoperative general data, showing comparability ( P>0.05). The follow-up time was (7.3±0.9) months for the PFBN group and (7.4±1.1) months for the PFNA group, showing no significant difference ( P>0.05). There was no significant difference either between the 2 groups in operation time, intraoperative blood loss or quality of fracture reduction ( P>0.05). The PFNA group had significantly shorter fracture healing time [(3.9±0.9) months] than the PFNA group [(4.7±1.1) months], and a significantly higher Harris hip score at the last follow-up [(83.9±4.3) points] than the PFNA group [(81.0±3.4) points] (both P<0.05). Fixation failed in one patient in the PFNA group due to cut-out of the head and neck screws while no complications were observed in the PFBN group. Conclusion:In the treatment of intertrochanteric fracture of the femur, PFBN fixation may result in stronger fixation to effectively avoid cut-out of the head and neck screws, and faster fracture healing and functional recovery of the hip than PFNA fixation.
ABSTRACT
OBJECTIVE@#To evaluate effectiveness of proximal femur bionic nail (PFBN) in treatment of intertrochanteric fractures in the elderly compared to the proximal femoral nail antirotation (PFNA).@*METHODS@#A retrospective analysis was made on 48 geriatric patients with intertrochanteric fractures, who met the selection criteria and were admitted between January 2020 and December 2022. Among them, 24 cases were treated with PFBN fixation after fracture reduction (PFBN group), and 24 cases were treated with PFNA fixation (PFNA group). There was no significant difference in baseline data such as age, gender, cause of injury, side and type of fracture, time from injury to operation, and preoperative mobility score, American Society of Anesthesiologists (ASA) score, Alzheimer's disease degree scoring, self-care ability score, osteoporosis degree (T value), and combined medical diseases between the two groups ( P>0.05). The operation time, intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, occurrence of complications, weight-bearing time after operation, and postoperative visual analogue scale (VAS) score, walking ability score, mobility score, self-care ability score were recorded and compared between the two groups. And the radiographic assessment of fracture reduction quality and postoperative stability, and fracture healing time were recorded.@*RESULTS@#The operations in both groups were successfully completed. All patients were followed up 6-15 months with an average time of 9.8 months in PFBN group and 9.6 months in PFNA group. The operation time was significantly longer in PFBN group than in PFNA group ( P<0.05), but there was no significant difference in intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, change in activity ability score, and change in self-care ability score between the two groups ( P>0.05). The weight-bearing time after operation was significantly shorter in PFBN group than in PFNA group ( P<0.05), and the postoperative VAS score and walking ability score were significantly better in PFBN group than in PFNA group ( P<0.05). Radiographic assessment showed no significant difference in fracture reduction scores and postoperative stability scores between the two groups ( P>0.05). All fractures healed and there was no significant difference in fracture healing time between the two groups ( P>0.05). The incidence of complications was significantly lower in PFBN group (16.7%, 4/24) than in PFNA group (45.8%, 11/24) ( P<0.05).@*CONCLUSION@#Compared with PFNA, PFBN in the treatment of elderly intertrochanteric fractures can effectively relieve postoperative pain, shorten bed time, reduce the risk of complications, and facilitate the recovery of patients' hip joint function and walking ability.
Subject(s)
Humans , Aged , Retrospective Studies , Fracture Fixation, Intramedullary , Bionics , Blood Loss, Surgical , Treatment Outcome , Bone Nails , Hip Fractures/surgery , FemurABSTRACT
Intertrochanteric fractures have become a severe public health problem in elderly patients. Proximal femoral nail anti-rotation (PFNA) is a commonly used intramedullary fixation device for unstable intertrochanteric fractures. Pelvic perforation by cephalic screw is a rare complication. We reported an 84-year-old female who fell at home and sustained an intertrochanteric fracture. The patient underwent surgery with PFNA as the intramedullary fixation device. Routine postoperative examination revealed medial migration of the helical blade that eventually caused pelvic perforation. We performed a cemented total hip arthroplasty as the savage procedure. At the latest follow-up of 12 months after total hip arthroplasty, the patient had no pain or loosening of the prosthesis in the left hip. Pelvic perforation should be considered when choosing PFNA as the intramedullary fixation device, especially in patients with severe osteoporosis wherein the helical blade can be easily inserted during the operation. The lack of devices to avoid oversliding of the helical blade in PFNA is an unreported cause of this complication and should be considered in such cases.
Subject(s)
Aged , Aged, 80 and over , Female , Humans , Bone Nails/adverse effects , Femur , Fracture Fixation, Intramedullary/adverse effects , Hip Fractures/surgery , Retrospective Studies , Treatment OutcomeABSTRACT
Objective:To investigate the clinical effect of long-stem hemiarthroplasty in the treatment of unstable intertrochanteric fracture in elderly patients with severe osteoporosis.Methods:A retrospective analysis was performed on 48 elderly patients with unstable intertrochanteric fractures of the femur with severe osteoporosis in Liaocheng People′s Hospital from April 2017 to April 2019.Twenty three patients received long-stem hemiarthroplasty (LHA group). Twenty five patients were treated with proximal femoral nail anti-rotation (PFNA) (PFNA group). PFNA group was used as the control group.The operative time, intraoperative blood loss, perioperative blood transfusion volume, number of intraoperative fluoroscopy, weight-bearing time after operation, the incidence of postoperative complications, hospitalization time, and Harris hip score of 1, 3, 6, 12 months after surgery, to investigate the efficacy of the application of long-stem hemiarthroplasty.Results:In LHA group, 23 patients were followed up for (18.6±3.9) (range from 12.0 to 26.0) months, and 25 patients in the PFNA group were followed up for (17.8±3.3)(range from 12.0 to 24.0) months.There was no significant difference in follow-up time between the two groups ( Z=-0.552, P=0.581). The operation time of LHA Group (60 (55, 73) h) was longer than that of PFNA Group (55 (50, 60) h). The intraoperative blood loss in LHA Group ((179.35±63.47) mL) was more than that in PFNA Group ((122.80±49.03) mL). The number of fluoroscopy in LHA Group (2 (2, 2) times)was less than that in PFNA Group (16 (14.5, 19.5) times). The time of weight bearing in LHA Group (4 (3, 5) d) was earlier than that in PFNA Group (33 (30, 36) d), and the differences were statistically significant ( Z=2.459, t=3.470, Z=6.216, Z=5.959; all P<0.05). There were no significant differences in perioperative blood transfusion, hospital stay and postoperative complications between the two groups (all P>0.05). Harris hip function score was significantly higher in LHA Group ((76.70±5.96), (82.13±6.38), (85.96±7.16), (88.78±7.67) points) and PFNA Group ((63.80±3.46), (71.56±2.55), (81.60±3.38), (88.08±4.83) points) increased gradually with the increase of follow-up time ( Fintra-group=432.557, Pintra-group<0.001), and the score reached the highest 12 months after operation.Harris hip function score of LHA group was higher than that of PFNA group( Finter-group=25.437, Pinter-group<0.001). There was interaction effect between follow-up time point and operation mode( Finteraction=53.464, Pinteraction<0.001). Conclusion:For the elderly patients with unstable intertrochanteric fracture with severe osteoporosis, the application of lengthened stem hemiarthroplasty can get out of bed early, reduce the complications of bed rest, reduce the number of intraoperative fluoroscopy, and recover the function of hip joint earlier and better with satisfactory results.
ABSTRACT
@#Introduction: Both short and long PFNA are employed to treat intertrochanteric fractures. Controversy exists in the choice between the two nails as each implant has specific characteristics and theoretical advantages. This retrospective study seeks to examine the operative complication rates and clinical outcomes of short versus long (Proximal Femoral Nail Antirotation) PFNA in the treatment of intertrochanteric fractures. Materials and methods: Between July 2011 and February 2015, 155 patients underwent PFNA insertion. The decision on whether to use a short or long PFNA nail, locked or unlocked, was determined by the attending operating surgeon. Visual Analogue Pain Score (VAS) Harris Hip Scores (HHS), Short-form 36 Health Questionnaire (SF-36) and Parker Mobility Scores (PMS) were collected at six weeks, six months and one year post-operatively. Results: A total of 137 (88.4%) patients were successfully followed-up. Forty-two (30.7%) patients received a short PFNA. The patients were similar in baseline characteristics of age, gender, and comorbidities. Operative time was significantly longer in the short PFNA group (62 ±17 mins) versus the long PFNA group (56±17). While the patients in both groups achieved improvement in all outcome measures, there was no significant difference between the groups in terms of HHS (61.0 ±16.0 vs 63.0 ±16.8, p=0.443), PMS (2.3±1.5 vs 2.7±2.1, p=0.545) and VAS (1.7±2.9 vs 1.8 ±2.2 p=0.454). There were 3 (7.1%) and 7 (7.4%) complications in the short versus long PFNA group, respectively. Conclusion: Both short and long PFNA had similar clinical outcomes and complication rates in the treatment of intertrochanteric fractures in an Asian population.
ABSTRACT
Objective: To compare the effectiveness of proximal femoral nail anti-rotation (PFNA) combined with minimally invasive percutaneous plate osteosynthesis (MIPPO) and Intertan intramedullary nail fixation by closed reduction in the treatment of AO/Orthopaedic Trauma Association (AO/OTA) type 31-A3.3 intertrochanteric fracture with incomplete lateral wall. Methods: The clinical data of 54 patients with AO/OTA type 31-A3.3 intertrochanteric fracture who met the selection criteria and were admitted between January 2012 and January 2018 were retrospectively analyzed. According to different surgical methods, the patients were divided into group A (24 cases with lateral wall reconstruction by MIPPO combined with PFNA internal fixation) and group B (30 cases with Intertan intramedullary nail fixation by closed reduction only). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, side of injury, cause of injury, and combined medical diseases. The operation time, intraoperative blood loss, time to weight-bearing, fracture healing time, and postoperative complications were recorded and compared between the two groups. The tip apex distance (TAD) was measured at 2 days, 2 months, and 1 year after operation. At 12 months after operation, the hip joint function was evaluated according to Harris scoring standard, and the rate of conformity (Harris score were more than 70) was calculated. Results: The wounds of the two groups healed by first intention, without infection, skin deformity, and other incision complications. The operation time and intraoperative blood loss of group A were significantly more than those of group B, and the time to weight-bearing and fracture healing were significantly shorter than those of group B ( P0.05). There was 1 case of infection, 1 case of screw withdrawal, 2 cases of screw removal, and 1 case of bone nonunion in group B, the incidence of complications was 16.7%; there was only 1 case of screw withdrawal combined with screw blade withdrawal in group A, the incidence of complications was 4.2%; there was no significant difference between the two groups ( χ2=2.109, P=0.146). At 12 months after operation, the Harris scores of pain, function, malunion, range of motion, and total score in group A were significantly better than those in group B ( P<0.05). The rate of conformity of group A was 95.83% (23/24) and 76.67% (23/30) in group B, and the difference between the two groups was significant ( χ2=3.881, P=0.049). Conclusion: For the AO/OTA type 31-A3.3 intertrochanteric fracture with incomplete lateral wall, compared with the closed reduction Intertan intramedullary nail fixation, the incidence of internal fixation failure after MIPPO reconstruction with lateral wall combined with PFNA fixation was lower, the time to weight-bearing was earlier, and the postoperative function was better.
ABSTRACT
Objective: To investigate the effect of the screw blade position on the effectiveness of proximal femoral nail anti-rotation (PFNA) internal fixation for unstable intertrochanteric fractures in the elderly. Methods: A clinical data of 131 elderly patients with unstable intertrochanteric fractures who were treated with PFNA internal fixation between January 2010 and January 2017 was retrospectively analyzed. According to the anteroposterior X-ray films, the screw blades were placed in the middle of the femoral neck in 72 patients (group A) and at one-third of the femoral neck in 59 patients (group B). There was no significant difference between the two groups ( P>0.05) in the gender, age, bone density, classification of fractures, other medical diseases, and the time between injury and operation. Multiple treatment indexes were analyzed, including complications, hip Harris score, the healing status of fracture, tip-apex distance (TAD), and the height of the tail nail. Results: All patients were followed up 11-14 months, with an average of 12.1 months. All incisions healed by first intention with no complications. All fractures healed and no significant difference in bone healing time between the two groups ( Z=-0.190, P=0.849). At 6 months after operation, TAD was (2.23±0.07) cm in group A and (2.85±0.12) cm in group B, showing significant difference ( t=-47.643, P=0.000); and the height of the tail nail was (1.72±0.14) cm in group A and (0.53±0.26) cm in group B, showing significant difference ( t=31.031, P=0.000). According to the Harris score, the hip functions were rated as excellent in 48 cases, good in 15 cases, and poor in 9 cases in group A, while as excellent in 38 cases, good in 16 cases, and poor in 5 cases in group B, with no significant difference between the two groups ( Z=-0.075, P=0.941). Conclusion: For the unstable intertrochanteric fracture in the elderly, the PFNA internal fixation with appropriated TAD and the screw blades placed in the middle or at one-third of the femoral neck can obtain good effectiveness.
ABSTRACT
Objective: To compare the effectiveness of proximal femoral nail anti-rotation (PFNA) in the treatment of intertrochanteric fracture of femur in traction bed supine position and non-traction bed lateral position. Methods: A retrospective analysis of 102 elderly patients with intertrochanteric fracture of femur who met the selection criteria between January 2013 and April 2018 was made. According to the different operative positions, the patients were divided into two groups: group A (50 cases, PFNA internal fixation in traction bed supine position) and group B (52 cases, PFNA internal fixation in non-traction bed lateral position). There was no significant difference in age, gender, fracture side, cause of injury, AO classification, complications, and time from injury to operation between the two groups ( P>0.05). The preoperative preparation time, incision length, operation time, intraoperative blood loss, intraoperative X-ray fluoroscopy times, fracture healing time, and complications were recorded and compared between the two groups, and the effectiveness was evaluated by Harris hip score at 1 year after operation. Results: There was no significant difference in incision length between groups A and B ( t=1.116, P=0.268). In addition, the preoperative preparation time, operation time, intraoperative blood loss, and intraoperative X-ray fluoroscopy times in group A were significantly greater than those in group B ( P<0.05). Both groups were followed up 12-14 months, with an average of 13 months. There were 3 postoperative complications in group A and group B respectively. In group A, there were 2 cases of hip joint pain and 1 case of local fat liquefaction (healed after dressing change); in group B, there were 2 cases of hip joint pain and 1 case of deep vein thrombosis in lower extremity; there was no significant difference in the incidence of postoperative complications between the two groups ( P=0.642). The patients of the two groups had a good result of fracture reduction and the internal fixation quality, and there was no main nail loosening, screw fracture, spiral blade cutting, withdrawal, and the nail breakage occurred, and no nonunion of bone, coxa vara, and other complications occurred. X-ray showed that the fracture healed in both groups, and there was no significant difference in fracture healing time between the two groups ( t=1.515, P=0.133). There was no significant difference in Harris hip score between the two groups at 1 year after operation ( t=0.778, P=0.438). Conclusion: Compared with the traction bed supine position, PFNA internal fixation for intertrochanteric fracture of femur in the non-traction bed lateral position has the advantages of short preparation time, short operation time, less intraoperative blood loss, less X-ray fluoroscopy times, and satisfactory postoperative recovery effect.
ABSTRACT
BACKGROUND: Osteoporosis and fracture type are two important reasons for the failure of internal fixation of proximal femoral nail antirotation. Type AO31-A3.3 intertrochanteric fracture, because of its involvement in the lateral wall, greatly increased the instability of the fracture. In addition, the elderly are mostly osteoporosis patients, so failure and postoperative complications of internal fixation of proximal femoral nail antirotation in the elderly with type AO31-A3.3 intertrochanteric fracture are higher. OBJECTIVE: To explore the difference of biomechanics between bone cement augmented and common proximal femoral nail antirotation in the treatment of type AO31-A3.3 intertrochanteric fracture. METHODS: CT data of one 75-year-old volunteer with intertrochanteric fracture were selected to import into Mimics 19.0 and Geomagic studio 2017 software to extract and optimize the three-dimensional model of the right femur. SolidWorks 2017 software was used to draw the internal fixation model and assemble it with the femur model according to the standard operation technology. The model was imported into Hypermesh 14.0 software to cut the bone to obtain the type AO31-A3.3 model with common proximal femoral nail antirotation. The cancellous bone around the proximal end of the screw blade was redefined as bone cement, which is the model of bone cement augmented proximal femoral nail antirotation. The material property parameters, boundary conditions and applied loads were set up and stored as K files respectively and imported into LS-DYNA software for solution. RESULTS AND CONCLUSION: (1) Compared with the common proximal femoral nail antirotation, the treatment of the elderly type AO31-A3.3 intertrochanteric fracture with the bone cement augmented proximal femoral nail antirotation has the advantages of lighter cutting degree of the screw blade, smaller varus, rotation angle and displacement of the femoral head and neck bone block, and better biomechanical effect. (2) The complete lateral wall can effectively support the femoral head and neck bone block and resist the skull and neck bone block as the lateral action point of three-point support. The pronation and rotation tendency can effectively prevent the head and neck screws from withdrawing. (3) The strong anchoring force of bone cement can stabilize the screw blade, enhance the internal action point of three-point support, and conduct and disperse the pressure.
ABSTRACT
BACKGROUND: Proximal femoral anti-rotation intramedullary nail for treating intertrochanteric fracture is widely used in clinical practice, but there are still some cases of failure of internal fixation after operation, and osteoporosis of proximal femur is considered as an important reason. Singh index is an important index to evaluate the severity of osteoporosis in the proximal femur. Based on the Singh index, it is of great significance to explore the effect of different degrees of osteoporosis on the treatment of intertrochanteric fracture with anti-rotation intramedullary nail in the proximal femur, so as to reduce the failure rate of internal fixation and increase the success rate of operation. OBJECTIVE: To explore the effect of different osteoporosis on the treatment of intertrochanteric fracture with proximal femoral anti-rotation intramedullary nail, so as to provide new ideas and experimental basis for clinical treatment of intertrochanteric fracture. METHODS: CT data of one patient with intertrochanteric fracture of the left femur were imported into Mimics 19.0 and Geomagic studio 2017 software to extract and optimize the three-dimensional model of the right femur. SolidWorks 2017 software was used to draw the internal fixation model and assemble it with the femur model according to the standard operation technology, and import it into HyperMesh 14.0 software in STEP format to cut the bone according to AO-2.1 type of intertrochanteric fracture. Trabecular bone based on Singh index 1-6 was established to obtain six models of A-F. Material property parameters, boundary conditions and applied loads were set. Finally, the data were stored as K files and imported into LS-DYNA software for solution. RESULTS AND CONCLUSION: (1) When the femoral head was stressed, the spiral blade in the bone block of the femoral head and neck of Singh 6-Singh 1 was cut, the common bone trabecula disappeared, the stress bone trabecula wrapped with the spiral blade did not disappear, but loaded with certain stress, so that the spiral blade still had a large contact area and holding force, maintained the reduction of the fracture, and reduced the varus and rotation of the bone block of the femoral head and neck. (2) From Singh 6-Singh 1, with the disappearance of stress bone trabecula, the more serious osteoporosis is, the more likely failure will be in the treatment of intertrochanteric fracture with proximal femoral anti-rotation intramedullary nail. (3) The spongy bone trabeculae, especially the stress bone trabeculae, play an important role in maintaining the elastic stability of the proximal femur by resisting and buffering the bending strain.
ABSTRACT
BACKGROUND: Proximal femoral nail is the first choice for treating intertrochanteric fractures. The studies concerning proximal femoral nail for senile intertrochanteric fractures mainly focus on proximal femoral nail antirotation/proximal femoral nail antirotation II, Gamma 3 and intertrochanteric antegrade nail. OBJECTIVE: To investigate the clinical efficacy of proximal femoral nail antirotation II versus intertrochanteric antegrade nail in the treatment of intertrochanteric fracture in the elderly. METHODS: Forty-two cases of senile intertrochanteric fractures at Department of Orthopedics, First People’s Hospital of Xuancheng City from January 2016 to December 2018 were included, involving 15 males and 27 females, aged 65-90 years. Among which, 22 patients received internal fixation using proximal femoral nail antirotation II and 20 patients using intertrochanteric antegrade nail. The operation time, intraoperative blood loss, fracture healing time, postoperative complications and the hip function scores at last follow-up were compared. The study was approved by the Ethics Committee of First People’s Hospital of Xuancheng City, approval No. (2015)(17). RESULTS AND CONCLUSION: (1) The operation time in the proximal femoral nail antirotation group was shorter than that in the intertrochanteric antegrade nail group [(69.4±11.5), (90.0±9.7) minutes, P 0.05]. (3) In the proximal femoral nail antirotation group, three cases suffered from pain at the affected limb, and one case of coxa vara deformity. One case in the intertrochanteric antegrade nail group appeared with pain at the affected limb. The postoperative incidence of complications between two groups showed no significant difference (18.2%, 5.0%, P > 0.05). (4) No significant difference was found in the Harris scores at the last follow-up between two groups (90.3±2.8, 91.5±2.4, P > 0.05). (5) There were no fracture adverse reactions related to internal fixation materials in the two groups. (6) In summary, proximal femoral nail antirotation II and intertrochanteric antegrade nail internal fixation are effective methods for intertrochanteric fractures in the elderly. However, proximal femoral nail antirotation II has short operation time and few intraoperative blood losses.
ABSTRACT
BACKGROUND: In the elderly patients with intertrochanteric fractures, a large amount of hidden bleeding appears after surgery, so reducing hidden bleeding has become an important problem to be solved urgently. OBJECTIVE: To evaluate the effect of preoperative intravenous injection of tranexamic acid on the hidden blood loss after proximal femoral nail antirotation implantation. METHODS: Eighty-two cases of senile intertrochanteric fractures at Department of Traumatic Orthopedics of Guang’an People’s Hospital from July 2018 to July 2019 were selected, and all the patients underwent internal fixation with proximal femoral nail antirotation. The patients were allocated into two groups based on usage of tranexamic acid (n=41/group). In trial group, intravenous injection of tranexamic acid (10 mg/kg) was conducted during anesthesia, and control group was given the same volume of normal saline via vein. Blood routine examination was conducted at baseline and 1, 3 and 5 days postoperatively to count the level of hemoglobin and hematocrit. The total blood loss was calculated by Gross equation. The transfusion rate and postoperative incidence of thrombosis were recorded. RESULTS AND CONCLUSION: (1) There was no significant difference in the dominant blood loss between two groups (P > 0.05). (2) The perioperative actual total blood loss and postoperative hidden blood loss in the trial group were significantly lower than those in the control group (P < 0.05). (3) Three cases of blood transfusion (7%) in the trial group, and eight cases (24%) in the control group (P < 0.05). (4) No thrombosis occurred in both groups. (5) These findings suggest that preoperative intravenous infusion of tranexamic acid can effectively reduce the hidden blood loss after proximal femoral nail antirotation implantation, and does not increase the risk of postoperative thrombosis.
ABSTRACT
BACKGROUND: The proximal femur anti-rotation intramedullary nail is an ideal internal fixation method for the treatment of intertrochanteric fractures, but there is still a 6% to 21% failure rate of internal fixation. Tip-apex distance is considered as an important cause of postoperative proximal femur anti-rotation intramedullary nail failure. Tip-apex distance is the sum of the distance from the tip of lag screw to the vertex of femoral head measured on anteroposterior and lateral X-ray films. Most scholars now believe that the tip-apex distance of head pulp nail ≤ 25 mm has a good prognosis, but there is still a lot of controversy. OBJECTIVE: To investigate the biomechanical differences of the treatment of intertrochanteric femoral fractures by proximal femoral anti-rotation intramedullary nail with different tip-apex distances and provide a new idea and experimental basis for the clinical treatment of intertrochanteric fractures. METHODS: CT data of one volunteer were imported into Mimics 19.0 and Geomagic studio 2017 software to extract and optimize the three-dimensional model of the right femur. SolidWorks 2017 software was used to draw the internal fixation model and assemble it with the AO2.1 type fracture femur model in different tip-apex distance according to the standard operation technology. Totally four models with tip-apex distance of 15, 20, 25, and 30 mm were obtained and imported into HyperMesh 14.0 software to mesh. The four models were imported into Abaqus 2016 software in inp format to set up with material property parameters, boundary conditions and applied loads. Finally, operation results were viewed in the visualization module. RESULTS AND CONCLUSION: (1) When tip-apex distance was too large (30 mm) or too small (15 mm), the stress at the proximal femur was reduced, but the displacement of the femur head and neck fragment and the lesser trochanter fragment was larger and the inversion was more serious. When tip-apex distance was in the middle (20, 25 mm), the displacement and varus of femoral head and neck fragment were small, and the lesser trochanteric fragment was basically unshifted. (2) In the treatment of intertrochanteric femur fractures, tip-apex distance should be adjusted to 20-25 mm to reduce displacement and obtain a better biomechanical effect.