1.
Braz. oral res. (Online) ; 33: e097, 2019. tab, graf
Article in English | LILACS | ID: biblio-1039297

ABSTRACT

Abstract To evaluate the torsional properties of engine-driven pathfinding instruments manufactured from different NiTi alloys - R-Pilot (tip size 12.5;.04 taper; M-Wire) and One G (tip size 14;.03 taper; Conventional NiTi). A total of 40 NiTi instruments from engine-driven pathfinding instruments (n = 20) were used. The torsion tests followed ISO 3630-1 (1992). Three millimeters of each instrument tip was fastened to a small load cell by a lever arm linked to the axis of torsion. During the test, the torsion testing machine software measured the maximum torsional strength and angle of rotation (0) before instrument failure. The fractured surface of each instrument was assessed by scanning electron microscopy (SEM). In addition, a supplementary examination was performed to measure the cross-sectional area and the metal mass volume of each instrument 3 mm from the tip. Data were analyzed using a t-test, with significance level set at 5%. R-pilot had significantly higher torsional strength than did One G (p < 0.05). Regarding the angle of rotation to fracture, One G had higher angles than did R-Pilot (p < 0.05). The supplementary examination showed that R-Pilot had the highest cross-sectional area and volume of metal mass at 3 mm from the tip (p < 0.05). R-pilot (M-Wire NiTi alloy) had a significantly higher torsional strength and One-G (superelastic NiTi alloy) had the highest angle of rotation to fracture.


Subject(s)
Root Canal Preparation/instrumentation , Dental Alloys/chemistry , Dental Instruments , Alloys/chemistry , Reference Values , Stress, Mechanical , Surface Properties , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Equipment Failure Analysis , Torque , Equipment Design
2.
Braz. oral res. (Online) ; 32(supl.1): e67, 2018. tab, graf
Article in English | LILACS | ID: biblio-974471

ABSTRACT

Abstract: The introduction of automated instrumentation in endodontics represented a major advance in progress for this specialty, with improvements in the quality and predictability of root canal preparation and a significant reduction in procedural errors. In recent years, endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments. In addition, new movements have also been incorporated to offer greater safety and efficiency, optimizing the properties of the NiTi alloy, especially through eccentric rotary motion. An understanding of the mechanical properties of these new NiTi instruments and their effect on the clinical performance of root canal preparation is essential if dental practitioners are to select the instruments that provide optimal clinical outcomes, especially in curved or flattened canals. The objective of this literature review is to present and discuss the characteristics of the NiTi alloys used in the major instrumentation systems available in the market, as well as the influence of the metallurgical and mechanical properties of NiTi instruments and the movements that drive them, to enable more accurate and predictable planning of root canal preparation.


Subject(s)
Humans , Root Canal Preparation/instrumentation , Equipment Design , Alloys/chemistry , Surface Properties , Root Canal Preparation/methods , Dental Alloys/chemistry , Dental Instruments
3.
J. appl. oral sci ; 24(5): 496-502, Sept.-Oct. 2016. tab, graf
Article in English | LILACS, BBO | ID: lil-797980

ABSTRACT

ABSTRACT Objective: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires placed in different types of brackets: metallic, reinforced polycarbonate with metallic slots, sapphire, passive and active self-ligating, by assessing strength values variation according to gradual increase in wire diameter and deflection and comparing different combinations in the different deflections. Material and Methods: Specimens were set in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using the ISO 15841 protocol. Data were subjected to One-way ANOVA, followed by Tukey tests (p<0.05). Results: Self-ligating brackets presented the most similar behavior to each other. For conventional brackets there was no consistent behavior for any of the deflections studied. Conclusions: Self-ligating brackets presented the most consistent and predictable results while conventional brackets, as esthetic brackets, showed very different patterns of forces. Self-ligating brackets showed higher strength in all deflections when compared with the others, in 0.020-inch wires.


Subject(s)
Orthodontic Wires , Orthodontic Brackets , Alloys/chemistry , Polycarboxylate Cement/chemistry , Reference Values , Titanium/chemistry , Materials Testing , Analysis of Variance , Orthodontic Appliance Design , Friction , Statistics, Nonparametric , Elasticity , Nickel/chemistry
4.
Braz. oral res. (Online) ; 29(1): 1-8, 2015. tab, ilus
Article in English | LILACS | ID: lil-777219

ABSTRACT

This study aims at comparing conventional and nickel-free metal bracket surface characteristics with elemental composition by scanning electron microscopy (SEM), using energy dispersive spectroscopy (EDS). The sample consisted of 40 lower incisor brackets divided into four groups: ABZ = conventional brackets, Kirium Abzil 3M® (n = 10); RL = conventional brackets, Roth Light Morelli® (n = 10); NF = nickel-free brackets, Nickel-Free Morelli® (n = 10); and RM = nickel-free brackets, Roth Max Morelli® (n = 10). Qualitative evaluation of the bracket surface was performed using SEM, whereby surface features were described and compared. The elemental composition was analyzed by EDS. According to surface analysis,groups ABZ and RL showed a homogeneous surface, with better finishing, whereas the surfaces in groups NF and RM were rougher. The chemical components with the highest percentage were Fe, Cr and C. Groups NF and MR showed no nickel in their composition. In conclusion, the bracket surface of the ABZ and RL groups was more homogeneous, with grooves and pores, whereas the surfaces in groups NF and RM showed numerous flaws, cracks, pores and grooves. The chemical composition analysis confirmed that the nickel-free brackets had no Ni in their composition, as confirmed by the manufacturer’s specifications, and were therefore safe to use in patients with a medical history of allergy to this metal.


Subject(s)
Metals/chemistry , Nickel/chemistry , Orthodontic Brackets , Analysis of Variance , Alloys/chemistry , Corrosion , Materials Testing , Microscopy, Electron, Scanning , Reference Values , Spectrometry, X-Ray Emission , Statistics, Nonparametric , Surface Properties
5.
Dental press j. orthod. (Impr.) ; 19(3): 114-119, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-723151

ABSTRACT

OBJECTIVE: To compare the frictional resistance between self-ligating and conventional brackets tied to different types of wire. MATERIAL AND METHODS : Abzil Kirium Capelozza (Pattern I) and Easy Clip (Roth prescription) incisor brackets were used. An elastomeric ligature or a ligating wire 0.10-in was used to ligate the wire to the Abzil bracket. Three types of orthodontic archwire alloys were assessed: 0.016-in NiTi wire, 0.016 x 0.021-in NiTi wire and 0.019 x 0.025-in steel wire. Ten observations were carried out for each bracket-archwire angulation combination. Brackets were mounted in a special appliance, positioned at 90 degrees in relation to the wire and tested in two angulations. Frictional test was performed in a Universal Testing Machine at 5 mm/min and 10 mm of displacement. The means (MPa) were submitted to ANOVA and Tukey's test set at 5% of significance. The surfaces of wires and brackets were observed at SEM. RESULTS: Steel-tied brackets (16.48 ± 8.31) showed higher means of frictional resistance than elastomeric-tied brackets (4.29 ± 2.16 ) and self-ligating brackets (1.66 ± 1.57) (P < 0.05), which also differed from each other (P < 0.05). As for the type of wire, 0.019 x 0.025-in steel wire (5.67 ± 3.97) showed lower means (P < 0.05) than 0.16-in NiTi wire (8.26 ± 10.92) and 0.016 x 0.021-in NiTi wire (8.51 ± 7.95), which did not differ from each other (P > 0.05). No statistical differences (P > 0.05) were found between zero (7.76 ± 8.46) and five-degree (7.19 ± 7.93) angulations. CONCLUSIONS: Friction was influenced not only by the type of bracket, but also by the ligating systems. Different morphological aspects were observed for the brackets and wires studied .


OBJETIVO: comparar a resistência ao atrito entre braquetes autoligáveis e braquetes convencionais, variando o tipo de fio. MÉTODOS: foram usados braquetes incisivos Abzil Kirium Capelozza e Easy Clip. Uma ligadura elastomérica ou um fio ligável de 0,010" foi usado para ligação do fio no braquete Abzil. Três tipos de ligas de fio ortodôntico foram avaliadas: fio de NiTi de 0,016"; fio de NiTi de 0,016" x 0,022"; e fio de aço de 0,019" x 0,025". Dez observações foram feitas para cada combinação "braquete-fio-inclinação". Os braquetes foram montados em um aparelho especial, posicionados a 90° em relação ao fio, e testados em duas inclinações. O teste de atrito foi realizado na máquina universal de ensaios, a 5mm/min e com 10mm de deslocamento. As médias (em MPa) foram submetidas aos testes ANOVA e de Tukey, a 5% de significância. As superfícies dos fios e dos braquetes foram observadas no MEV. RESULTADOS: o braquete com amarrilhos metálicos (16,48 ± 8,31MPa) apresentou médias mais altas que o braquete com ligaduras elastoméricas (4,29 ± 2,16MPa) e o braquete autoligável (1,66 ± 1,57) (p < 0,05), os quais também diferiram entre si (p < 0,05). Quanto ao tipo do fio, o fio de aço de 0,019" x 0,025" (5,67 ± 3,97MPa) apresentou médias mais baixas (p < 0,05) que os fios de NiTi de 0,016" (8,26 ± 10,92MPa) e de 0,016" x 0,022" (8,51 ± 7,95), os quais não diferiram entre si (p > 0,05). Nenhuma diferença estatística (p > 0,05) foi encontrada entre inclinações de zero (7,76 ± 8,46) e cinco (7,19 ± 7,93) graus. Concluão: o atrito foi influenciado pelo tipo de braquete e sistemas de ligaduras. Diferentes aspectos morfológicos foram observados para os braquetes e fios estudados. .


Subject(s)
Humans , Dental Alloys/chemistry , Dental Materials/chemistry , Elastomers/chemistry , Orthodontic Appliance Design , Orthodontic Brackets , Orthodontic Wires , Alloys/chemistry , Dental Stress Analysis/instrumentation , Friction , Materials Testing , Microscopy, Electron, Scanning , Nickel/chemistry , Stress, Mechanical , Surface Properties , Stainless Steel/chemistry , Titanium/chemistry
6.
Braz. dent. j ; 23(4): 387-393, 2012. tab
Article in English | LILACS | ID: lil-658015

ABSTRACT

Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.


Desinfetantes químicos são normalmente associados a métodos mecânicos para remover manchas e reduzir a formação do biofilme. Este estudo avaliou o efeito de desinfetantes na liberação de íons metálicos e na rugosidade superficial do titânio comercialmente puro, ligas metálicas e resina acrílica termopolimerizável, simulando 180 ensaios de imersões. Espécimes em formato de discos foram confeccionados com titânio comercialmente puro (Tritan), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Os espécimes (n=5) foram imersos nestas soluções: hipoclorito de sódio a 0,05%, Periogard, Cepacol, Corega Tabs, Medical Interporous e Polident. Como controle, foi utilizada a água deionizada. A análise quantitativa de liberação de íons metálicos foi realizada por meio de espectrometria de massa com plasma indutivamente acoplado (ELAN DRC II). O rugosímetro (Surftest SJ-201P) foi utilizado para medir a rugosidade superficial (µm). Os dados foram registrados antes e depois das imersões e avaliados por ANOVA com dois fatores e teste de Tukey (α=0,05). A liberação de níquel provou ser mais expressiva nas ligas Vi-Star e Fit Cast-V após a imersão em Medical Interporous. Houve diferença significante na rugosidade superficial da resina (p=0,011) após a imersão. O Cepacol causou maior rugosidade superficial de forma significativa. Os produtos de imersão não influenciaram nos resultados da rugosidade do metal (p=0,388). Pode-se concluir que as ligas metálicas testadas podem ser consideradas seguras para a fabricação de próteses removíveis, mas as soluções desinfetantes como o Cepacol e a pastilha Medical Interporous para a imersão diária da prótese devem ser utilizados com cautela, pois causaram maior rugosidade superficial da resina e maior liberação de íons, respectivamente.


Subject(s)
Humans , Denture Bases , Dental Alloys/chemistry , Denture Cleansers/chemistry , Acrylic Resins/chemistry , Alloys/chemistry , Aluminum/analysis , Beryllium/analysis , Borates/chemistry , Cetylpyridinium/chemistry , Chlorhexidine/analogs & derivatives , Chlorhexidine/chemistry , Chromium Alloys/chemistry , Chromium/analysis , Citric Acid/chemistry , Dental Disinfectants/chemistry , Dental Materials/chemistry , Materials Testing , Metals/analysis , Metals/chemistry , Molybdenum/analysis , Nickel/analysis , Spectrophotometry, Atomic , Surface Properties , Sodium Hypochlorite/chemistry , Sulfates/chemistry , Titanium/analysis , Titanium/chemistry
7.
Journal of Korean Medical Science ; : 1170-1176, 2012.
Article in English | WPRIM | ID: wpr-164998

ABSTRACT

We investigated tissue responses to endoskeleton stent grafts for saccular abdominal aortic aneurysms (AAAs) in canines. Saccular AAAs were made with Dacron patch in 8 dogs, and were excluded by endoskeleton stent grafts composed of nitinol stent and expanded polytetrafluoroethylene graft. Animals were sacrificed at 2 months (Group 1; n = 3) or 6 months (Group 2; n = 5) after the placement, respectively. The aortas embedding stent grafts were excised en bloc for gross inspection and sliced at 5 to 8 mm intervals for histopathologic evaluation. Stent grafts were patent in all except a dog showing a thrombotic occlusion in Group 2. In the 7 dogs with patent lumen, the graft overhanging the saccular aneurysm was covered by thick or thin thrombi with no endothelial layer, and the graft over the aortic wall was completely covered by neointima with an endothelial layer. Transgraft cell migration was less active at an aneurysm than at adjacent normal aorta. In conclusion, endoskeleton stent grafts over saccular aneurysms show no endothelial coverage and poor transgraft cell migration in a canine model.


Subject(s)
Animals , Dogs , Alloys/chemistry , Angiography , Aortic Aneurysm, Abdominal/pathology , Cell Movement , Disease Models, Animal , Endothelial Cells/cytology , Neointima/etiology , Polytetrafluoroethylene/chemistry , Stents , Thrombosis/etiology , Tomography, X-Ray Computed
8.
Annals Abbassi Shaheed Hospital and Karachi Medical and Dental College. 2010; 15 (1): 58-62
in English | IMEMR | ID: emr-117871

ABSTRACT

Amalgam restorations often tarnish and corrode in a hostile oral environment. Corrosion of dental amalgam can produce galvanism in a mouth having amalgam restorations. Ion release as a result of corrosion is most important. Amalgams are categorized as high copper amalgam and conventional amalgam. The latter having copper content less than 6%, corrode more and have limited use nowadays. There are many factors that can produce corrosion in amalgam restorations. This study is performed to assess the effect of shape and size of the particles of an alloy on the corrodibility of various high copper amalgams. Samples were prepared using three high copper amalgams having particles of various size and shape. The samples were tested for rate of corrosion using electrochemical corrosion testing apparatus. The data was collected and analyzed applying ANOVA. The results reveal that corrosion resistance of lathecut amalgam was significantly higher than spherical and admixed amalgams. High copper Lathe-cut amalgam has higher corrosion resistance than other amalgams


Subject(s)
Alloys/chemistry , Corrosion , Chemistry, Physical , Copper
9.
Article in English | IMSEAR | ID: sea-139772

ABSTRACT

Objectives: This study aims to evaluate and compare the mechanical and metallurgical properties of stainless steel and titanium molybdenum alloy (TMA) archwires, with recently introduced timolium and titanium niobium arch wires. Materials and Methods: Archwires were categorized into four groups (group I to IV) with 10 samples in each group. They were evaluated for tensile strength, yield strength, modulus of elasticity, load deflection, frictional properties and weld characteristics. Results: The results were statistically analyzed using ANOVA test and it indicated that stainless steel has high strength, high stiffness and low friction compared to other arch wires, thereby proving that it is the best choice for both sliding as well as frictionless retraction mechanics. TMA with its high formability, low stiffness and low load deflection property is suited to apply consistent force in malaligned teeth but, high friction limits its use in retraction only with loop mechanics. Conclusion: Timolium possesses comparatively low stiffness, better strength and behaves as an intermediate between stainless steel and TMA and hence can be tried for almost all clinical situations. Low springback and high formability of titanium-niobium archwire allows creation of finishing bends and thus it can be used as finishing archwire.


Subject(s)
Alloys/chemistry , Dental Alloys/chemistry , Dental Soldering , Dental Stress Analysis/instrumentation , Elastic Modulus , Friction , Humans , Materials Testing , Metallurgy , Niobium/chemistry , Orthodontic Brackets , Orthodontic Wires , Pliability , Shear Strength , Stainless Steel/chemistry , Stress, Mechanical , Surface Properties , Tensile Strength , Titanium/chemistry
10.
J. appl. oral sci ; 17(5): 421-426, Sept.-Oct. 2009. ilus, graf
Article in English | LILACS | ID: lil-531390

ABSTRACT

Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. OBJECTIVE: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. MATERIAL AND METHODS: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37ºC and thermocycling (37ºC/5ºC/37ºC/55ºC/37ºC). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (α=0.05). RESULTS: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. CONCLUSION: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results.


Subject(s)
Humans , Dental Alloys/toxicity , Dental Casting Investment/toxicity , Dental Materials/toxicity , Titanium/toxicity , Alloys/chemistry , Alloys/toxicity , Aluminum Oxide/chemistry , Biocompatible Materials/chemistry , Biocompatible Materials/toxicity , Cell Count , Cell Line, Tumor , Carbon Compounds, Inorganic/chemistry , Cell Survival/drug effects , Chromium Alloys/chemistry , Chromium Alloys/toxicity , Dental Casting Technique , Dental Etching , Dental Alloys/chemistry , Dental Casting Investment/chemistry , Dental Materials/chemistry , Dental Polishing/methods , Diamond/chemistry , Materials Testing , Saliva, Artificial/chemistry , Silicon Compounds/chemistry , Silicon Dioxide/chemistry , Temperature , Titanium/chemistry
11.
Journal of Korean Medical Science ; : 315-319, 2008.
Article in English | WPRIM | ID: wpr-173547

ABSTRACT

Many patients are currently suffering from nickel (Ni)-induced allergic contact dermatitis (ACD). There have been few Korean studies dealing with the threshold of Ni-induced ACD and quantifying the total amount of Ni in the metal alloys. The aim of this study is to evaluate the amount of Ni leached from metal alloys and Ni contents in metal alloys, and to estimate the threshold of Ni-induced ACD. All the earrings we examined leached below 0.5 microgram/cm(2)/week, the upper limit of European Union (EU) regulation, but the other metal alloys leached a much higher amount of Ni than the limit. Likewise, all the earrings we examined contained less than 0.05% Ni (500 microgram/g), the upper limit of EU regulation, but the other metal alloys exceeded this limit. Twenty Ni-sensitive subjects, who were patch-tested with various concentrations of Ni sulphate, showed positive reactions to 5% and 1% Ni sulphate, 10 subjects showed positive reactions to 0.01%, and the most sensitive subject showed reaction even to 0.0001%. The subjects in this study were more sensitive to Ni than those in the previous studies done in Europe. Taken together, strictly regulating the Ni-containing alloys that are made in Korea is needed to lower the occurrence of Ni-induced ACD.


Subject(s)
Humans , Alloys/chemistry , Dermatitis, Allergic Contact/metabolism , Dermatitis, Contact/diagnosis , European Union , Irritants , Korea , Metals/chemistry , Nickel/analysis , Patch Tests , Petrolatum , Quality Control , Time Factors
12.
Braz. dent. j ; 14(1): 32-36, June 2003. ilus, tab
Article in English | LILACS | ID: lil-340486

ABSTRACT

Copper/aluminum alloys are largely utilized in odontological restorations because they are less expensive than gold or platinum. However, tarnishing and important corrosion in intrabuccal prostheses made with copper/aluminum alloys after 28 days of use have been reported. Several kinds of food and beverage may attack and corrode these alloys. Copper is an essential component of several important enzymes directly involved in mitochondrial respiratory metabolism. Aluminum, in contrast, is very toxic and, when absorbed, plasma values as small as 1.65 to 21.55 µg/dl can cause severe lesions to the nervous system, kidneys, and bone marrow. Because mitochondria are extremely sensitive to minimal variation of cellular physiology, the direct relationship between the mitocondrial respiratory chain and cell lesions has been used as a sensitive parameter to evaluate cellular aggression by external agents. This work consisted in the polarographic study of mitochondrial respiratory metabolism of livers and kidneys of rabbits with femoral implants of titanium or copper/aluminum alloy screws. The experimental results obtained did not show physiological modifications of hepatic or renal mitochondria isolated from animals of the three experimental groups, which indicate good biocompatibility of copper/aluminum alloys and suggest their odontological use


Subject(s)
Animals , Male , Rabbits , Alloys/chemistry , Aluminum/chemistry , Biocompatible Materials/chemistry , Copper/chemistry , Mitochondria/metabolism , Bone Screws , Corrosion , Dental Materials/chemistry , Femur/surgery , Kidney/drug effects , Kidney/metabolism , Mitochondria, Liver/drug effects , Mitochondria, Liver/metabolism , Mitochondria/drug effects , Oxygen Consumption/drug effects , Oxygen Consumption/physiology , Polarography , Statistics as Topic , Surface Properties , Subcellular Fractions/drug effects , Subcellular Fractions/metabolism , Titanium/chemistry
13.
J. bras. ortodontia ortop. maxilar ; 1(3): 29-41, maio-jun. 1996. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-203307

ABSTRACT

Este trabalho tem por objetivo levar aos profissionais da área da ortodontia, uma série de conceitos relacionados à estrutura interna dos materiais metálicos, propriedades mecânicas e fenômenos que levam à falha desses materiais. O trabalho aborda ainda, de maneira sucinta, alguns dos principais assuntos que estäo atualmente em destaque na área de Ortodontia


Subject(s)
Alloys/chemistry , Chromium Alloys/chemistry , In Vitro Techniques , Molecular Structure , Orthodontic Appliances , Stainless Steel/chemistry , Dental Instruments , Nickel/chemistry , Pliability
14.
Indian J Physiol Pharmacol ; 1994 Jul; 38(3): 197-201
Article in English | IMSEAR | ID: sea-108868

ABSTRACT

A method has been developed for the standardization of Indian ayurvedic drugs containing iron, using inorganic ion exchange material antimony (V) arsenosilicate cation exchanger. The iron present in the drug was absorbed quantitatively on the columns of the exchanger, eluted with a suitable solvent and then titrated against a standardized EDTA solution.


Subject(s)
Alloys/chemistry , Antimony/chemistry , Edetic Acid/chemistry , India , Ion Exchange Resins/chemistry , Iron/analysis , Medicine, Ayurvedic , Microspheres , Trace Elements/analysis
15.
Rev. estomatol. Hered ; 3(1): 25-8, ene.-jun. 1993. tab, ilus
Article in Spanish | LILACS, LIPECS | ID: lil-154659

ABSTRACT

Se evaluó visualmente la alteración de color y de brillo de aleaciones de Cu-Al y Cu-Al-Zn, sometiendo las muestras a la acción de diversos medios de inmersión, en función del tiempo. Se observaron también la infuencia de la presencia de una restauración de amalgama adyacente a la prótesis y el comportamiento de la unión soldada.


Subject(s)
Dental Alloys/analysis , Dental Alloys/therapeutic use , Dental Alloys/chemistry , In Vitro Techniques , Dental Soldering , Alloys/analysis , Alloys/chemistry