Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Rev. bras. oftalmol ; 78(4): 255-259, July-Aug. 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1013688

ABSTRACT

Resumo Objetivos: Comparar a aniseiconia e a estereopsia em escolares anisometropes do primeiro ano do ensino fundamental corrigidos com lentes oftálmicas de estoque com curvas-base selecionadas para minimizar a diferença de tamanho interocular das imagens retínicas e com lentes iseicônicas sugeridas pelo software Aniseikonia Inspector 3 e verificar a preferência dos escolares por uma destas formas de correção. Métodos: Dezenove escolares com anisometropia ≥ 1,5 D em meridianos correspondentes no uso de óculos com lentes oftálmicas de estoque e com lentes iseicônicas foram avaliados para aniseiconia (software Aniseikonia Inspector 3) e estereopsia (teste Stereo Fly test com símbolos LEA. A preferência por uma das formas de correção foi verificada após 40-50 dias de uso dos óculos. Resultados: As médias e os desvios-padrão das aniseiconias vertical e horizontal no uso de óculos com lentes oftálmicas de estoque e com lentes iseicônicas foram, respectivamente, -1,05% ± 2,20% e -1,37% ± 2,36% (p=0,82739) e -0,895% ± 2,23% e -1,16% ± 2,03% (p=0,77018). 31,6% dos escolares corrigidos com lentes iseicônicas e 21,1% dos escolares corrigidos com lentes oftálmicas de estoque identificaram os optotipos que sugerem estereopsia < 100 segundos de arco (p= 0,475). Em relação à preferência, 4/15 (26,7%) escolheram os óculos com lentes iseicônicas, 2/15 (13,3%) escolheram os óculos com lentes oftálmicas de estoque e para 9/15 (60%) a escolha foi indiferente. Conclusão: A aniseiconia induzida nos escolares anisometropes corrigidos com lentes iseicônicas sugeridas pelo software Aniseikonia Inspector 3 foi similar ao obtido na correção com lentes oftálmicas de estoque com curvas-base selecionadas para minimizar a diferença de tamanho interocular das imagens retínicas.


Abstract Objectives: To compare the aniseikonia and the stereopsis in school children anisometropes of the first-year of elementary school corrected with stock ophthalmic lenses with base curve selected to minimize the interocular size difference of retinal images and with size lenses suggested by the software Aniseikonia Inspector 3, and to check the preference of them for one of these forms of correction. Methods: Nineteen school children with anisometropia ≥ 1.5 D in corresponding meridians, in the use of glasses with stock ophthalmic lenses and with size lenses were evaluated for aniseikonia (software Aniseikonia Inspector 3) and stereopsis (Stereo Fly test with LEA symbols). The preference for one of the forms of correction was verified after 40-50 days of wearing glasses. Results: The mean and standard deviations of the vertical and horizontal aniseikonia in the use of glasses with stock ophthalmic lenses and with size lenses were, respectively, -1.05% ± 2.20% and-1.37% ± 2.36% (p = 0,82739) and -0.895% ± 2.23% and -1.16% ± 2.03% (p = 0,77018). 31.6% of the school children corrected with size lenses and 21.1% of the students corrected with stock ophthalmic lenses identified the optotypes that suggest stereopsis less than 100 seconds of arc (p = 0.475). Regarding the preference, 4/15 (26.7%) of the students chose the glasses with size lenses, 2/15 (13.3%) chose the glasses with stock ophthalmic lenses, and for 9/15 (60%) the choice was indifferent. Conclusion: The induced aniseikonia in school children with anisometropia corrected with size lenses suggested by the software Aniseikonia Inspector 3 was similar to that obtained in the correction with stock ophthalmic lenses with base curves selected to minimize the difference of interocular size of retinal images.


Subject(s)
Humans , Male , Female , Child , Anisometropia/therapy , Aniseikonia/therapy , Students , Student Health , Prospective Studies , Depth Perception , Eyeglasses , Lenses
2.
Journal of the Korean Ophthalmological Society ; : 99-104, 2004.
Article in Korean | WPRIM | ID: wpr-59763

ABSTRACT

PURPOSE: To study the effect of spherical lens induced aniseikonia on stereopsis and fusion. METHODS: One hundred subjects, with normal binocular function without any ophthalmic disease or surgery history, were examined. The aniseikonia was induced with spherical lenses in 1 diopter (D) stepwise manner from -2 D to +2 D. The amount of aniseikonia was measured by Awaya's New Aniseikonia Test. Stereopsis and fusion were determined with Titmus Stereo Test and fusion card of major amblyoscope respectively. RESULTS: As the amount of aniseikonia was increased, the stereopsis and fusion were decreased. The change was statistically significant (ANOVA, p<0.001). Aniseikonia was more correlated to fusion than stereopsis. A significant decline in the stereopsis was detected when the size of aniseikonia changed from 1% to 2%. A significant decline in fusion was noticed when aniseikonia changed from 2% to 3% (Independent t-test, p<0.01). CONCLUSIONS: Our study suggests that binocular function can be disturbed by experimentally induced aniseikonia in normal subjects and that stereoacuities and fusional amplitude can be decreased as the degree of aniseikonia becomes larger.


Subject(s)
Aniseikonia , Depth Perception , Telescopes
3.
Rev. cuba. oftalmol ; 11(1): 32-8, ene.-jun. 1998. tab
Article in Spanish | LILACS | ID: lil-249361

ABSTRACT

Mediante un programa automatizado, se evaluaron los resultados de la microcirugía de catarata con implantación de lente intraocular de cámara posterior, en 137 ojos. Este trabajo permitió analizar las diferentes variables que influyen en esta cirugía de forma individual y colectiva, así como la recolección de datos de forma uniforme. Los resultados de la agudeza visual alcanzada son notables: el 32,12 por ciento no presento defecto esférico, 31,39 por ciento alcanzó la agudeza visual de la unidad con refracción dinámica, 16,79 por ciento alcanzó una agudeza visual mayor a 0,8 y 9,49 por ciento obtuvo la agudeza visual mayor a 0,5. El 100 por ciento de los ojos presentó astigmatismo residual. Se definieron y evaluaron diferentes variables constantes que influyeron en el cálculo del poder dióptrico del lente intraocular (LIO). Los programas se encuentran a disposición de cualquier oftalmólogo que desee usar esta técnica


Subject(s)
Humans , Aniseikonia , Astigmatism , Cataract Extraction , Lenses, Intraocular , Microsurgery , Refraction, Ocular , Visual Acuity
4.
Indian J Ophthalmol ; 1991 Oct-Dec; 39(4): 170-3
Article in English | IMSEAR | ID: sea-70792

ABSTRACT

Physiological aniseikonia is the basis of stereopsis but beyond certain limits it becomes an obstacle to fusion. It is not well established as to how much aniseikonia can be tolerated by the fusional mechanism. Different tests under different testing conditions have given a wide range of variation. On the synoptophore we had observed tolerance upto 35% aniseikonia in some cases. Under more physiological conditions on a polaroid dissociation stereoprojector we observed lesser baseline fusional vergences but tolerance in about 70% of the cases upto 30% aniseikonia while 25% could tolerate even 35% aniseikonia. However we realise that these indicate the maximal potential and not the symptom free tolerable limits.


Subject(s)
Aniseikonia/physiopathology , Convergence, Ocular/physiology , Depth Perception/physiology , Humans , Vision Disparity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL