Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Rev. bras. oftalmol ; 77(5): 272-277, set.-out. 2018. tab, graf
Article in English | LILACS | ID: biblio-977871

ABSTRACT

Abstract Purpose: To report the prevalence and analyse corneal astigmatism patterns in cataract surgery candidates. Methods: Researchers examined 2136 eyes from 1204 patients for cataract surgery from 1 January to 31 December 2016. All the candidates were evaluated with partial coherence interferometry (IOLMaster). The results were analysed statistically in relation to qualitative and quantitative variables. Results: The mean age of the patients was 71.9 years with a female predominance. Mean corneal astigmatism was 1.0 dioptre (D). Against the rule (ATR) astigmatism increased with age. Women presented with steeper corneas than men. In those patients who had both eyes measured, we found strong correlations between amount of right and left eye astigmatism, axis and keratometry. Overall, 39% of the eyes had corneal astigmatism > 1.00 D and 19% >1.50 D. Conclusions: A significant percentage of our population presents with corneal astigmatism > 1.00 D with a shift from WTR (with the rule) to ATR with increasing age. Our findings, in a population that has never been described before, will be helpful to surgeons to enhance surgical techniques, patients to improve visual outcomes, IOL (intraocular lens) manufacturers to make better designs and health agents to optimise resources.


Resumo Objetivo: Relatar a prevalência e analisar os padrões de astigmatismo corneano em candidatos à cirurgia de catarata. Métodos: Os pesquisadores examinaram 2136 olhos de 1204 pacientes a cirurgia de catarata de 1 de janeiro a 31 de dezembro de 2016. Todos os candidatos foram avaliados com interferometria de coerência parcial (IOLMaster). Os resultados foram analisados estatisticamente em relação às variáveis qualitativa e quantitativa. Resultados: A média de idade dos pacientes foi de 71,9 anos, com predomínio do sexo feminino. A média de astigmatismo corneano foi de 1,0 dioptria (D). Contra a regra (ATR), o astigmatismo aumentou com a idade. As mulheres apresentaram córneas mais íngremes que os homens. Nos pacientes que tiveram os dois olhos medidos, encontramos fortes correlações entre quantidade de astigmatismo nos olhos direito e esquerdo, eixo e ceratometria. No geral, 39% dos olhos tinham astigmatismo corneano >1,00 D, e 19% > 1,50 D. Conclusões: Uma percentagem significativa da nossa população apresenta astigmatismo corneano >1,00, D com uma mudança de WTR (a favor da regra) para ATR (contra a regra) com o aumento da idade. Nossas descobertas em uma população que nunca foi descrita antes serão úteis para os cirurgiões melhorarem suas técnicas cirúrgicas, os pacientes melhorarem seus resultados visuais, os fabricantes de LIOs (lentes intraoculares) criarem projetos melhores, e os agentes de saúde otimizarem os recursos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Astigmatism/epidemiology , Phacoemulsification/statistics & numerical data , Cornea/diagnostic imaging , Interferometry , Astigmatism/physiopathology , Cataract Extraction/statistics & numerical data , Prevalence , Biometry/instrumentation , Axial Length, Eye , Optical Imaging/instrumentation , Anterior Chamber
2.
Korean Journal of Ophthalmology ; : 53-59, 2016.
Article in English | WPRIM | ID: wpr-197513

ABSTRACT

PURPOSE: To investigate the changes in corneal higher-order aberration (HOA) during amblyopia treatment and the correlation between HOA and astigmatism in hyperopic amblyopia children. METHODS: In this retrospective study, a total of 72 eyes from 72 patients ranging in age from 38 to 161 months were included. Patients were divided into two groups based on the degree of astigmatism. Corneal HOA was measured using a KR-1W aberrometer at the initial visit and at 3-, 6-, and 12-month follow-ups. Correlation analysis was performed to assess the association between HOA and astigmatism. RESULTS: A total of 72 patients were enrolled in this study, 37 of which were classified as belonging to the higher astigmatism group, while 35 were assigned to the lower astigmatism group. There was a statistically significant difference in success rate between the higher and lower astigmatism groups. In both groups, all corneal HOAs were significantly reduced during amblyopia treatment. When comparing the two groups, a significant difference in coma HOA at the 12-month follow-up was detected (p = 0.043). In the Pearson correlation test, coma HOA at the 12-month follow-up demonstrated a statistically significant correlation with astigmatism and a stronger correlation with astigmatism in the higher astigmatism group than in the lower astigmatism group (coefficient values, 0.383 and 0.284 as well as p = 0.021 and p = 0.038, respectively). CONCLUSIONS: HOA, particularly coma HOA, correlated with astigmatism and could exert effects in cases involving hyperopic amblyopia.


Subject(s)
Adolescent , Child , Child, Preschool , Humans , Aberrometry , Amblyopia/physiopathology , Astigmatism/physiopathology , Corneal Topography , Corneal Wavefront Aberration/diagnosis , Eyeglasses , Follow-Up Studies , Hyperopia/physiopathology , Retrospective Studies , Visual Acuity/physiology
3.
Yonsei Medical Journal ; : 1097-1105, 2015.
Article in English | WPRIM | ID: wpr-150473

ABSTRACT

PURPOSE: To compare the astigmatic power of toric intraocular lenses (IOLs) obtained from the AcrySof, TECNIS, and iTrace toric calculator in patients with preoperative with-the-rule (WTR) or against-the-rule (ATR) corneal astigmatism. MATERIALS AND METHODS: Fifty eyes with cataract and corneal astigmatism greater than 0.75 diopters were enrolled in each group (WTR and ATR). Keratometric values were measured using autokeratometry, an IOLMaster, and an iTrace, which incorporated corneal topography and ray-tracing aberrometry. Based on measured keratometric values, the astigmatic power of each toric IOL was calculated using three toric calculators. RESULTS: Bland-Altman plots showed good agreement between six pairwise corneal astigmatism values in both groups. The TECNIS calculator tended to suggest a higher astigmatic power of the toric IOL than the AcrySof calculator. With the higher astigmatism and keratometric values from the IOLMaster, in both groups, calculations from the AcrySof and TECNIS calculators resulted in higher calculated astigmatic powers than those from same calculators with autokeratometry-measured values, demonstrating good agreement. With the higher calculated astigmatic power values, the values from the iTrace toric calculator using keratometric values obtained from iTrace ray tracing wavefront aberrometry or iTrace simulated keratometry showed fair to moderate agreement with those from the other calculator-keratometry pairs in both groups. CONCLUSION: To achieve the best refractive outcome after toric IOL implantation, understanding the differences in keratometric values between instruments and in calculated astigmatic power among toric calculator programs is necessary. Moreover, systemic analysis of each toric calculator in conjunction with postoperative data is required.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aberrometry , Astigmatism/physiopathology , Cataract , Cornea/surgery , Corneal Topography , Eye , Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification/methods , Postoperative Period , Refraction, Ocular/physiology , Visual Acuity/physiology
4.
Arq. bras. oftalmol ; 77(3): 159-163, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-723831

ABSTRACT

Purpose: To assess the reliability and reproducibility of static cyclotorsion correction (SCC) measurements made using the Schwind Amaris Excimer laser in patients undergoing LASIK or PRK, and compare the outcomes of treating astigmatism with and without SCC. Methods: Eighty eyes of 40 patients were included in this study. All eyes underwent 2 or 3 sets of five measurements: before and after speculum placement, and after flap-lift (in LASIK cases). We assessed the reproducibility, accuracy, and the percentage of "no catch" measurements. The astigmatism was calculated pre-and 3-months-postoperatively by vector analysis. Results: The mean age of the patients was 23.67 ± 4.19 years. Preoperative spherical equivalent and astigmatism were -2.56 ± 2.86 D and +1.36 ± 0.98 D, respectively. The mean measurement time was 15.1 seconds per measurement. The percentages of "no catch" were: 63.8%, 14.9%, and 26.9%; pre-speculum, post-speculum, and post flap-lift, respectively. Cyclotorsion of ≥±2º was seen in 41.25% and 66% of the cases before and after the flap-lift, respectively. Significant cyclotorsion (≥±5º) was seen in 12.50% and 18% of the eyes pre and post flap-lift. The mean astigmatism dropped from +1.53 D@1º to +0.34D@3º when SCC was used and from +1.86D@1º to +0.23D@7º when SCC was not used. No statistical difference was noticed between the groups (p>0.05) in the postoperative residual astigmatism. A postoperative astigmatism of ≥1 D was seen in 10% and 20% of eyes with and without SCC, respectively (p<0.01). Conclusion: Although not always feasible, the SCC measurement is a simple and useful tool. Postoperative astigmatism showed less variability when SCC was used. .


Objetivo: Avaliar a confiabilidade e reprodutibilidade da correção da medida de ciclotorção estática (SCC), realizada com o excimer laser Schwind Amaris em pacientes submetidos a LASIK ou PRK, e comparar os resultados do tratamento de astigmatismo com e sem SCC. Método: Oitenta olhos (40 pacientes). Todos os olhos foram submetidos a 2 ou 3 séries de 5 medições: antes e após a colocação do espéculo, e depois do levantamento do flap (nos casos de LASIK). Foram avaliadas a reprodutibilidade, a precisão e a porcentagem de medições "não obtidas". O astigmatismo foi avaliado no pré-operatório e aos 3 meses de pós-operatório, por meio de análise vetorial. Resultados: A idade foi 23,67 ± 4,19 anos. O equivalente esférico e o astigmatismo pré-operatórios foram -2,56 ± 2,86 D, e 1,36 ± 0,98 D, respectivamente. O tempo de medição médio foi 15,1 segundos por medição; as porcentagens de medidas "não obtidas" foram: 63,8%, 14,9% e 26,9%; pré, pós-espéculo, e pós-levantamento do flap, respectivamente. Ciclotorção ≥±2º foi observada em 41,25% e 66 % dos casos pré e pós-levantamento do flap. Ciclotorção significativa (≥±5º) foi observada em 12,50% e 18% pré e pós-levantamento do flap. A média do astigmatismo diminuiu de 1,53D @ 1º para 0,34D @ 3º quando SCC foi usado e de 1,86D @ 1º a 0,23D @7º quando SCC não foi usado. O astigmatismo residual pós-operatório não foi estatisticamente diferente entre os grupos (p>0,05). O astigmatismo pós-operatório ≥1D foi observado em 10% e 20 % dos olhos com e sem SCC, respectivamente (p<0,01). Conclusão: A medição do SCC é fácil e útil, apesar de nem sempre ...


Subject(s)
Adult , Female , Humans , Male , Young Adult , Astigmatism/physiopathology , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Lasers, Excimer/therapeutic use , Torsion Abnormality/physiopathology , Torsion Abnormality/surgery , Cornea/surgery , Lasers, Excimer , Patient Positioning , Prospective Studies , Reproducibility of Results , Surgical Flaps , Time Factors , Treatment Outcome , Visual Acuity
5.
Rev. bras. oftalmol ; 73(1): 11-15, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-712759

ABSTRACT

Objective: To compare refractive and vectorial outcomes of limbal relaxing incisions (LRI) versus toric intraocular lenses (IOL) in the treatment of preexisting corneal astigmatism at the time of phacoemulsification. Methods: This longitudinal observational case series assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism between 0.75 and 2.50 diopters in both eyes. Patients were randomly assorted in two groups: one assigned to receive AcrySof Toric™ IOL in both eyes, and another one assigned to have AcrySof Natural™ IOL associated with LRI, also in both eyes. All patients were re-evaluated, postoperatively, at 1, 3 and 6 months, when refractive astigmatism analysis was performed using vectorial methods proposed by Thibos. Variability of outcomes within each group and between groups were assessed and compared. Results: Manifest refractive cylinder, in diopters (D), as means ± standard deviation, in the LRI group for 1-month, 3-month and 6-month re-evalutions were respectively -0.66 ± 0.30; -0.70 ± 0.21 and -0.74 ± 0.26 when compared to -0.58 ± 0.24; -0.63 ± 0.20, and -0.62 ± 0.17 in the toric IOL group. (p value ≥ 0.06). Vectorial analysis evidenced greater astigmatism reduction in the toric IOL group in the 6th postoperative month, when postoperative mean astigmatic power vector was 0.31 D, when compared to 0.37 D in the LRI group (p value = 0.00). Conclusions: A trend of slightly better refractive outcomes favoring toric IOL group was seen, although such a trend was not statistically significant. Vectorial analysis, however, suggests that the use of toric IOL may constitute a more advantageous approach in the treatment of pre-existing corneal astigmatism, simultaneously with phacoemulsification. .


Objetivo: Comparar os resultados refracionais e de análise vetorial, das incisões relaxantes limbares (IRL) versus lentes intraoculares (LIO) tóricas no tratamento do astigmatismo corneano pré-existente por ocasião da facoemulsificação. Métodos: Estudo observacional longitudinal (série de casos) no qual foram avaliados 62 olhos de 31 pacientes consecutivos de catarata com astigmatismo corneano pré-operatório entre 0,75 e 2,50 dioptrias para ambos os olhos. Os pacientes foram aleatoriamente distribuídos entre 2 grupos: um submetido a implante de LIO AcrySof Toric™ em ambos os olhos e outo grupo no qual seriam implantas LIO AcrySof Natural™ complementada por IRL, também em ambos os olhos. Todos os pacientes foram reavaliados com 1, 3 e 6 meses de pós-operatório, sendo feitas análises do astigmatismo refracional pelo métodos vetorial proposto por Alpins, interessando a variação de resultados dentro de cada grupo e entre os grupos. Resultados: O cilindro refracional manifesto, em dioptrias, expresso como média ± desvio padrão, para o grupo IRL, nas avaliações de 1, 3 e 6 meses, foram respectivamente -0,66 ± 0,30; -0,70 ± 0,21 e -0,74 ± 0,26 em comparação aos -0,58 ± 0,24; -0,63 ± 0,20 and -0,62 ± 0,17 do grupo LIO tórica (valor de p ≥ 0,06). A análise vetorial evidenciou maior redução no astigmatismo no grupo LIO tórica no 6º mês pós-operatório, para o qual vetor de poder astigmático médio foi de 0,31 D, comparado ao de 0,37 D do grupo IRL (valor de p = 0,00). Conclusões: Tendência a melhores resultados refracionais favorecendo o grupo LIO tórica foi encontrada, entretanto, significância estatística não foi evidenciada ao longo do estudo. A análise vetorial, sugere ...


Subject(s)
Humans , Male , Female , Aged , Astigmatism/surgery , Limbus Corneae/surgery , Phacoemulsification/methods , Cornea/surgery , Lens Implantation, Intraocular , Lenses, Intraocular , Refraction, Ocular/physiology , Astigmatism/physiopathology , Cataract , Visual Acuity/physiology , Longitudinal Studies , Cornea/physiopathology , Corneal Topography , Diagnostic Techniques, Ophthalmological , Observational Study
6.
Arq. bras. oftalmol ; 76(6): 339-340, nov.-dez. 2013. graf, tab
Article in English | LILACS | ID: lil-701282

ABSTRACT

PURPOSE: The aim of this study was to verify the presence of cyclotorsion in eyes that underwent laser refractive surgery. METHODS: This was a comparative observational study, which analyzed the medical records of 61 patients (104 eyes) who underwent laser refractive surgery and compared the axis of astigmatism of the sitting and the supine positions. Regarding the gender, 37.5% were male and 62.5% were female. The age ranged from 20 to 54 years old, with the median of 29 years. The lowest degree of astigmatism was -0.75 cylinder diopters (DC) and the highest was -6.50 DC, with a mean of -3.06 ± 1.16 DC. First, the axis of astigmatism of the seated patient was captured by the Schwind's ORK-CAM. In a second moment, inside the operating room, the axis of astigmatism of the patient in supine position was captured by the laser equipment's own camera (Schwind Amaris®), which was then compared with the previous measure. The incyclotorsion was defined by a minus sign (-) and the excyclotorsion, by a plus sign (+). RESULTS: The maximum excyclotorsion was +7.7 and the maximum incyclotorsion was -11.0 degrees. The mean torsion (excyclo or incyclo) was 2.74 (56.7%), with a standard deviation of 2.30 degrees. There was no statistically significant change (p=0.985) in the axis of astigmatism between patients sitting versus supine. CONCLUSION: There was clinically significant cyclotorsion in 36.5% of the eyes submitted to laser correction.


OBJETIVO: Verificar a presença de ciclotorção em olhos submetidos à cirurgia refrativa a laser. MÉTODOS: Realizou-se um estudo observacional comparativo, feito pela avaliação dos prontuários de 61 indivíduos (104 olhos) submetidos à cirurgia refrativa a laser, para comparar a orientação do astigmatismo ocular na posição sentada e em decúbito dorsal. Foram computados 37,5% de homens com idade variando de 20 a 54 anos, com mediana de 29 anos. O menor grau de astigmatismo avaliado foi de -0,75 e o maior de -6,50, com média de -3,06 ± 1,16 dioptrias cilíndricas (DC). A captação da orientação (eixo) do astigmatismo foi feita no primeiro momento (sentado) pelo aparelho ORK-CAM da empresa Schwind. Em um segundo momento (decúbito dorsal), na sala de cirurgia, o eixo foi captado pela câmera do próprio laser (Schwind Amaris®) para então comparar o eixo nos dois momentos. A inciclotorção foi identificada por um sinal negativo (-) e a exciclotorção por um sinal positivo (+). RESULTADOS: A exciclotorção máxima foi de +7,7 e a inciclotorção máxima de -11,0 graus. A média de torção (exciclo ou inciclo) foi de 2,74 (56,7%), com desvio padrão de 2,30 graus. Não houve variação estatisticamente significativa (p=0,985) no eixo do astigmatismo entre os indivíduos sentados versus decúbito dorsal. CONCLUSÃO: Houve ciclotorção clinicamente significativa em 36,5% dos olhos submetidos à cirurgia refrativa a laser.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Astigmatism/surgery , Cornea/surgery , Corneal Surgery, Laser/methods , Astigmatism/physiopathology , Cornea/physiopathology , Eye Movements , Medical Records , Reference Values , Severity of Illness Index , Statistics, Nonparametric , Supine Position , Torsion Abnormality , Treatment Outcome
7.
Arq. bras. oftalmol ; 76(4): 233-236, jul.-ago. 2013. graf, tab
Article in Portuguese | LILACS | ID: lil-686560

ABSTRACT

OBJETIVOS: Comparar a acuidade visual dos pacientes que foram submetidos à facoemulsificação com implante de LIO AcrySof® tórica versus LIO AcrySof® IQ e avaliar a redução da dioptria cilíndrica (DC) pós-operatória. MÉTODOS: Estudo analítico retrospectivo de 149 olhos submetidos à cirurgia de catarata por facoemulsificação, com astigmatismo ceratométrico regular, simétrico, com 1 dioptria ou mais. Foram divididos em dois grupos. O grupo tórica com 85 olhos e o grupo não tórica com 64 olhos. No pré-operatório foram avaliados dados topográficos do olho a ser operado e refração. No período pós-operatório foram revisados dados da refração e acuidades visuais com e sem correção. RESULTADOS: O astigmatismo corneano pré-operatório variou de 1,00 a 5,6 DC em ambos os grupos, sendo que no grupo tórica houve redução média de 1,37 DC (p<0,001), quando comparado ao refracional. O grupo não tórica apresentou redução média de 0,16 DC (p=0,057). Com relação a acuidade visual sem correção (AVSC), o grupo tórica apresentou 44 olhos (51,7%) com AVSC de 0 logMAR (20/20) ou 0,1 logMAR (20/25), e o grupo não tórica apenas 7 olhos (10,93%) com estas mesmas AVSC. DISCUSSÃO: Ficou bem evidenciado que os pacientes com astigmatismo ceratométrico significativo apresentam benefício visual com o implante de LIO tórica. A diminuição do uso de auxílios ópticos para distância pode ser possível a partir do momento que conseguimos corrigir com melhor precisão as aberrações do olho humano. Na atualidade, a facoemulsificação passou a ser além de uma cirurgia para restabelecimento funcional, um procedimento refracional.


PURPOSES: Compare the visual acuity of patients who underwent cataract surgery by phacoemulsification with IOL AcrySof® toric implantation versus AcrySof® IQ and evaluate the reduction of cylindrical diopters (CD) in the postoperative period. METHODS: Analytical and retrospective study of 149 eyes with 1 or more diopters of regular symmetrical keratometric astigmatism, which underwent cataract surgery by phacoemulsification. The eyes were divided into two groups: the toric group with 85 eyes and the non-toric group with 64 eyes. In the pre-operative phase, topographic data and refraction of each eye to be operated were assessed. In the postoperative phase, refraction and visual acuity with and without correction were measured. RESULTS: The preoperative topographic astigmatism ranged from 1.00 to 5.6 DC in both groups. Average reduction of 1.37 CD (p<0.001) and 0.16 CD (p=0.057) was obtained for the toric and non-toric group when compared to the refractive astigmatism, respectively. Considering visual acuity without correction (NCVA), the toric group presented 44 eyes (51.7%) with NCVA of 0 logMAR (20/20) or 0.1 logMAR (20/25) and the toric group presented 7 eyes (10.93%) with these same NCVA values. DISCUSSION: The results show that patients with a significant keratometric astigmatism presented visual benefits with the toric IOL implantation. The reduction of the use of optical aids may be obtained provided aberrations of the human eye are corrected more accurately. Currently, phacoemulsification surgery has been used not only for functional improvement, but also as a refraction procedure.


Subject(s)
Aged , Female , Humans , Male , Astigmatism/surgery , Lenses, Intraocular , Lens Implantation, Intraocular/methods , Phacoemulsification/methods , Visual Acuity/physiology , Astigmatism/physiopathology , Postoperative Period , Prosthesis Design , Reference Values , Retrospective Studies , Refraction, Ocular/physiology , Treatment Outcome
8.
Indian J Ophthalmol ; 2011 July; 59(4): 279-281
Article in English | IMSEAR | ID: sea-136189

ABSTRACT

Context: Boston ocular surface prosthesis (BOSP) is a scleral contact lens used in the management of patients who are rigid gas permeable (RGP) failures as with corneal ectasias such as keratoconus and in those patients who have ocular surface disease such as Stevens–Johnson syndrome (SJS). Aim: To report utilization of BOSP in a tertiary eye care center in India. Materials and Methods: We retrospectively reviewed charts of 32 patients who received BOSP from July 2008 to May 2009. Indications for fitting these lenses, improvement in visual acuity (VA) before and after lens fitting and relief of symptoms of pain and photophobia were noted. Paired t-test was used for statistical analysis using SPSS version 16.0 for Windows. Results: Thirty-two patients (43 eyes) received these lenses. These consisted of 23 eyes of 17 patients who failed RGP trials for irregular astigmatism and corneal ectasia such as keratoconus and post radial keratotomy and scar and 20 eyes of 15 patients with SJS. Mean age of RGP failures was 27.94 years. Pre- and post-BOSP wear mean LogMAR VA was 1.13 and 0.29, respectively, in RGP failures. The P value was statistically significant (P < 0.001). In patients with SJS, LogMAR VA was 0.84 ± 0.92 before and 0.56 ± 0.89 after lens wear. The P value was statistically significant (P < 0.001). VA improved by >2 lines in 7/20 eyes (35%) with SJS, with improvement in symptoms. Conclusion: BOSP improves VA in patients who have irregular astigmatism as in ectasias and RGP failures and improves vision and symptoms in patients with SJS.


Subject(s)
Adolescent , Adult , Astigmatism/physiopathology , Astigmatism/rehabilitation , Child , Contact Lenses/statistics & numerical data , Eye Diseases/etiology , Eye Diseases/physiopathology , Eye Diseases/rehabilitation , Humans , India , Keratoconus/physiopathology , Keratoconus/rehabilitation , Middle Aged , Retrospective Studies , Sclera , Stevens-Johnson Syndrome/complications , Vision, Ocular , Visual Acuity , Young Adult
9.
Arq. bras. oftalmol ; 72(6): 789-792, Nov.-Dec. 2009. tab
Article in Portuguese | LILACS | ID: lil-536772

ABSTRACT

OBJETIVO: Pesquisar um fator de correção para avaliação do erro refrativo sem a utilização da cicloplegia. MÉTODOS: Foram estudados 623 pacientes (1.246 olhos), de ambos os sexos, com idade entre 3 e 40 anos. As refratometrias estática e dinâmica foram obtidas usando-se o refrator automático Shin-Nippon Accuref-K 9001. A cicloplegia foi obtida com a instilação de uma gota de colírio ciclopentolato a 1 por cento, com refratometria estática 30 minutos após. Os dados foram submetidos à análise estatística usando a técnica do modelo de regressão linear e modelo de regressão múltipla do valor dióptrico com e sem cicloplegia, em função da idade. RESULTADOS: A correlação entre valores dióptricos sem e com cicloplegia quanto ao erro astigmático variou de 81,52 por cento a 92,27 por cento. Quanto ao valor dióptrico esférico, a correlação foi menor (53,57 por cento a 87,78 por cento). O mesmo se observou em relação ao eixo do astigmatismo (28,86 por cento a 58,80 por cento). O modelo de regressão múltipla em função da idade mostrou coeficiente de determinação múltiplo maior para a miopia (86,38 por cento) e astigmatismo (79,79 por cento). O menor coeficiente foi observado para o eixo do astigmatismo (17,70 por cento). CONCLUSÃO: Avaliando-se os erros refrativos com e sem cicloplegia, observou-se alta correlação nas ametropias cilíndricas. Foram desenvolvidas equações matemáticas como fator de correção para refratometrias dos pacientes sem cicloplegia, portadores de ametropias cilíndricas e esféricas.


PURPOSE: To determine a correction factor for refractive errors evaluated without cycloplegy effect. METHODS: A study was made with 623 patients (1,246 eyes) of both sexes, aging between 3 and 40 years old. The dynamic and static refractometries were obtained using the automated refractor Shin-Nippon Accuref-K 9001. 1 percent Cyclopentolate was dropped and the static refractometry was performed in 30 minutes. Data were analyzed using the linear regression model and the multiple regression model of the diopter values with and without cycloplegy effect according to age. RESULTS: The correlation between the astigmatism diopter values with and without cicloplegy ranged from 81.52 percent to 92.27 percent. Analyzing the spherical diopter values, the correlation was lower (53.57 percent to 87.78 percent). The astigmatism axis also revealed low correlation values (28.86 percent to 58.80 percent). The multiple regression model according to age demonstrated multiple determination coefficient with high values for myopia (86.38 percent) and astigmatism (79.79 percent). The lowest multiple determination coefficient was observed for astigmatism axis (17.70 percent). CONCLUSION: It was possible to demonstrate a high correlation in refractive errors with and without cycloplegy effect on the cylindrical ametropies. Mathematical formules, for cylindrical and spherical ametropies, were presented as a correction factor for refraction of the patients not submitted to cycloplegy.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Male , Young Adult , Accommodation, Ocular , Astigmatism/physiopathology , Myopia/physiopathology , Refraction, Ocular/physiology , Retinoscopy/methods , Accommodation, Ocular/drug effects , Accommodation, Ocular/physiology , Linear Models , Ophthalmic Solutions/administration & dosage , Young Adult
10.
Arq. bras. oftalmol ; 72(5): 687-693, set.-out. 2009. graf, tab
Article in Portuguese | LILACS | ID: lil-534193

ABSTRACT

OBJETIVO: Comparar a correção das aberrações oculares nos retratamentos de LASIK personalizado e convencional. MÉTODOS: Foi realizado um estudo prospectivo, randomizado, de 74 olhos de 37 pacientes submetidos ao retratamento de LASIK para correção de miopia e astigmatismo. Cada paciente foi submetido ao retratamento de LASIK personalizado Zyoptix (Bausch & Lomb) em um olho e convencional Planoscan (Bausch & Lomb) no olho contralateral. Foi comparada a correção das aberrações oculares nos retratamentos personalizado e convencional. RESULTADOS: No sexto mês pós-operatório, os olhos submetidos ao retratamento Zyoptix apresentaram diminuição estatisticamente significativa do defocus, astigmatismo, coma, aberração esférica, segunda ordem, terceira ordem, alta ordem e aberrações totais. Os olhos submetidos ao retratamento Planoscan apresentaram diminuição estatisticamente significativa do defocus, segunda ordem e aberrações totais. CONCLUSÕES: O retratamento personalizado foi superior ao retratamento convencional para a correção das aberrações oculares de baixa e alta ordens.


PURPOSE: To compare the correction of ocular aberrations between custom and standard LASIK retreatment. METHODS: Prospective, randomized trial with paired eye control of 74 eyes from 37 patients who underwent LASIK retreatment. Each patient underwent retreatment using Zyoptix LASIK (Bausch & Lomb) in 1 eye and Planoscan LASIK (Bausch & Lomb) in the fellow eye. Correction of ocular aberrations was compared between custom and standard LASIK retreatments. RESULTS: At 6 months, there was a statistically significant reduction in defocus, astigmatism, coma, spherical aberration, second, third, higher-order and total aberration in Zyoptix eyes. There was a statistically significant reduction in defocus, second-order and total aberration in Planoscan eyes. CONCLUSIONS: Custom retreatment was statistically superior than standard retreatment for correction of lower and higher ocular aberrations.


Subject(s)
Humans , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Astigmatism/physiopathology , Myopia/physiopathology , Prospective Studies , Retreatment , Statistics, Nonparametric , Time Factors
11.
Indian J Ophthalmol ; 2009 Jan-Feb; 57(1): 9-13
Article in English | IMSEAR | ID: sea-70449

ABSTRACT

The basis of manual small incision cataract surgery is the tunnel construction for entry to the anterior chamber. The parameters important for the structural integrity of the tunnel are the self-sealing property of the tunnel, the location of the wound on the sclera with respect to the limbus, and the shape of the wound. Cataract surgery has gone beyond just being a means to get the lens out of the eye. Postoperative astigmatism plays an important role in the evaluation of final outcome of surgery. Astigmatic consideration, hence, forms an integral part of incisional considerations prior to surgery.


Subject(s)
Astigmatism/physiopathology , Cataract Extraction/methods , Humans , Microsurgery/methods , Surgical Flaps , Wound Healing
12.
Indian J Ophthalmol ; 2009 Jan-Feb; 57(1): 31-3
Article in English | IMSEAR | ID: sea-70446

ABSTRACT

Manual chopping of the nucleus forms the backbone of nucleus reduction in manual small-incision cataract surgery (MSICS). The technique ("prechopping") described by Akahoshi has been modified so that it is safe, predictable, and easy to use in MSICS.


Subject(s)
Astigmatism/physiopathology , Cataract Extraction/methods , Humans , Lens Nucleus, Crystalline/surgery , Microsurgery/methods
13.
Arq. bras. oftalmol ; 71(6): 841-846, nov.-dez. 2008. graf, tab
Article in Portuguese | LILACS | ID: lil-503451

ABSTRACT

OBJETIVO: Avaliar a qualidade visual após retratamento personalizado e retratamento convencional em olhos submetidos a LASIK primário convencional. MÉTODOS: Foi realizado estudo prospectivo de 74 olhos submetidos ao retratamento de LASIK para correção de miopia e astigmatismo. Cada paciente foi submetido ao retratamento de LASIK com ablação personalizada (Zyoptix, Bausch & Lomb) em um olho e ablação convencional (Planoscan, Bausch & Lomb) no olho contralateral. Foram comparados os resultados do teste de ofuscamento e da sensibilidade ao contraste durante o acompanhamento de seis meses. RESULTADOS: Os olhos do grupo Zyoptix apresentaram melhores resultados no teste de ofuscamento e na sensibilidade ao contraste do que o olho contralateral, quando se compararam os resultados. CONCLUSÕES: O retratamento personalizado resultou em melhor qualidade visual pós-operatória do que o retratamento convencional de LASIK primário convencional.


PURPOSE: To evaluate visual quality after wavefront-guided LASIK versus standard LASIK in retreatment of primary LASIK for myopia and myopic astigmatism. METHODS: A prospective study was performed with paired eye control of 74 eyes with LASIK retreatment. Each patient underwent retreatment using custom ablation (Zyoptix, Bausch & Lomb) in 1 eye and standard ablation LASIK (PlanoScan, Bausch & Lomb) in the contralateral eye. A complete ophthalmologic examination was performed, including evaluation of glare test and contrast sensitivity test, with a follow-up of 6 months. RESULTS: Zyoptix eyes showed better results of glare test and contrast sensitivity test than the contralateral eyes. CONCLUSIONS: Wavefront-guided LASIK produces better visual quality than standard LASIK in the retreatment of refractive errors after primary LASIK.


Subject(s)
Humans , Astigmatism/surgery , Keratomileusis, Laser In Situ/methods , Myopia/surgery , Visual Acuity/physiology , Astigmatism/physiopathology , Contrast Sensitivity/physiology , Follow-Up Studies , Glare , Myopia/physiopathology , Prospective Studies , Retreatment , Statistics, Nonparametric , Treatment Outcome
14.
Arq. bras. oftalmol ; 70(6): 917-923, nov.-dez. 2007. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-474094

ABSTRACT

O objetivo principal deste trabalho foi o desenvolvimento e a implementação de um algoritmo para simulação de cirurgias foto-refrativas. Sabe-se que os atuais " flying-spot" lasers para cirurgia refrativa disponíveis no mercado ainda contêm limitações na correção de algumas aberrações de ordem alta. No entanto, há muito pouca informação quantitativa sobre os erros envolvidos em função da complexidade das aberrações. Aplicando-se superfícies objetivo descritas por uma série de coeficientes de Zernike e o conceito matemático de convolução, várias ablações personalizadas foram simuladas para várias aberrações, desde baixa ordem (esfero-cilíndricas) até aberrações de décima ordem (como coma, aberração esférica, entre outras). Os resultados mostram que o perfil de ablação de cada pulso do laser assim como seu diâmetro são fatores críticos quando o objetivo é corrigir aberrações de alta ordem. Além disso, outras conclusões foram possíveis, como por exemplo a de que nem todas as aberrações de alta ordem induzem aos mesmos erros na ablação. Também foi possível verificar que a correção de aberrações de alta ordem nos termos radiais (como aberração esférica) é bem mais difícil do que naqueles termos contendo alta frequência angular (como trefoil).


PURPOSE: To develop and implement an algorithm for simulation of photorefractive surgery. It is well known that many flying-spot lasers in the market have limitations in correcting higher order aberrations, but there is little quantitative information about errors related to aberration complexity. METHODS: By applying known surfaces described by Zernike polynomials of different orders it was possible to simulate several target surfaces that may well resemble in vivo cases of refractive surgery candidates. An algorithm that uses the mathematical concept of convolution was implemented and several simulated surfaces were tested, ranging from low order aberrations (sphere-cylinder) to 10th order aberrations, (high orders of coma, spherical aberration, trefoil, etc). RESULTS: the results show that the laser profile and diameter are critical factors when considering the correction of higher order aberrations. CONCLUSIONS: Not all aberrations of the same high order induce the same amount of error - spherical aberrations are shown to be far more difficult to correct than higher order aberrations related to angular frequency.


Subject(s)
Humans , Algorithms , Computer Simulation , Photorefractive Keratectomy/methods , Refractive Errors , Astigmatism/physiopathology , Astigmatism/surgery , Corneal Topography , Cornea/physiopathology , Cornea/surgery , Models, Theoretical , Refractive Surgical Procedures , Refraction, Ocular/physiology , Refractive Errors/physiopathology , Severity of Illness Index
15.
Arq. bras. oftalmol ; 70(6): 975-980, nov.-dez. 2007. graf, tab
Article in English | LILACS | ID: lil-474105

ABSTRACT

PURPOSE: To assess the long-term refractive outcomes of photorefractive keratectomy in myopia and myopic astigmatism. METHODS: A retrospective study of 120 photorefractive keratectomy operated eyes with at least four-year follow-up (maximum of 96 months, mean follow-up 55 months). We divided patients into group 1 (G1) spherical equivalent (SE) up to -4.00 diopters (D) and group 2 (G2) SE >-4.00 D. The Summit Apex Plus® excimer laser was used for ablation. All eyes were analyzed in terms of uncorrected and best spectacle corrected visual acuity (UCVA/BSCVA) and cycloplegic refraction. Data were analyzed using the Refractive Surgery Consultant Elite database software. RESULTS: G1 with 85 eyes (49 patients) presented mean SE -2.42 D and G2 with 35 eyes (22 patients) and mean SE of -4.45 D. Ninety-four percent of eyes in G1 and 82.9 percent of G2 were within ±1.00 D of emmetropia at 4 years. The UCVA was 20/30 or better in 82.0 percent of G1 eyes and 77.0 percent of G2 in the last postoperative follow-up. No patient lost more than one line in G2 compared to 13.0 percent in G1. Eyes that gained one or more lines after 4-year follow-up were 11.9 percent G1 and 2.9 percent in G2, respectively. A statistically significant positive correlation was found between achieved versus attempted refractive correction in both groups (r=0.925, p<0.0005). CONCLUSIONS: Photorefractive keratectomy was a safe and stable surgical procedure to correct myopic refractive errors, with no significant change in mean postoperative spherical equivalent refraction in the long-term follow-up.


OBJETIVO: Relatar os resultados a longo prazo da cirurgia de ceratectomia fotorefrativa em miopia e astigmatismo miópico. MÉTODOS: Estudo retrospectivo de120 olhos operados de ceratectomia fotorefrativa com um mínimo intervalo de 4 anos de seguimento pós-operatório (máximo de 96 meses e seguimento médio de 55 meses). Dividimos em grupo 1 (G1) com equivalente esférico (SE) até -4.00 dioptrias (D) e grupo 2(G2) SE > -4.00 D. O excimer laser Summit Apex Plus® foi usado na ablação. Foram obtidas acuidade visual não corrigida (UCVA) e melhor acuidade visual corrigida (BSCVA) e refração sob cicloplegia. Os dados foram analisados utilizando o programa Refractive Surgery Consultant Elite database®. RESULTADOS: G1 com 85 olhos (49 pacientes) apresentaram SE médio de -2.42 D e o G2 com 35 olhos (22 pacientes) e SE médio de -4,45 D. No G1 94 por cento e 82,9 por cento no G2 estavam entre ±1,00D de emetropia em 4 anos. A acuidade visual não corrigida foi de 20/30, ou melhor, em 82,0 por cento nos olhos de G1 e 77,0 por cento de G2 no último seguimento. Nenhum paciente perdeu mais do que uma linha de visão no G2 comparado com 13,0 por cento em G1. Ganho de linha de visão após 4 anos foi respectivamente 11,9 por cento em G1 e 2,9 por cento em G2. Correlação positiva estatisticamente significante foi encontrada entre correção refrativa programada versus atingida em ambos os grupos (r=0,925, p<0,0005). CONCLUSÃO: Ceratectomia fotorefrativa foi um procedimento cirúrgico seguro e estável para corrigir erros refracionais miópicos, sem mudança significativa no equivalente esférico médio da refração pós-operatória em longo prazo.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Astigmatism , Myopia , Photorefractive Keratectomy , Astigmatism/physiopathology , Astigmatism/surgery , Follow-Up Studies , Linear Models , Myopia/physiopathology , Myopia/surgery , Postoperative Period , Retrospective Studies , Refraction, Ocular/physiology , Safety , Time Factors , Treatment Outcome , Visual Acuity/physiology
16.
Arq. bras. oftalmol ; 70(6): 1040-1042, nov.-dez. 2007. ilus
Article in Portuguese | LILACS | ID: lil-474119

ABSTRACT

Atualmente tem-se desenvolvido novos tipos de lentes intra-oculares (LIO) que objetivam eliminar a presbiopia e o seu uso vem se popularizando. Descreve-se o caso de um paciente com catarata bilateral e irregularidades corneanas e astigmatismo maior que 2 D à topografia, no qual implantou-se a LIO AcrySof® ReSTOR® no olho esquerdo associado à realização de incisões limbares relaxantes para tentar diminuir o astigmatismo corneano observado. A acuidade visual pós-operatória, tanto para perto quanto para longe, ficou abaixo das expectativas, sem melhora à refração e sem uma outra alteração que a justificasse, além das citadas. Após 45 dias, sem melhora da acuidade visual, efetuou-se o explante desta LIO, seguindo-se de implante de uma monofocal, sendo observada melhora da acuidade visual corrigida final. Assim, o presente caso clínico reforça a necessidade de uma correta seleção pré-operatória dos pacientes candidatos ao implante deste tipo de LIO multifocal, atentando inclusive para os dados topográficos.


Currently, new types of intraocular lenses have been developed aiming to eliminate presbyopia and the use has become more popular. The authors report the case of a patient with bilateral cataract and corneal irregularities and astigmatism higher than 2D in the corneal topography, in which AcrySofTM ReSTOR TM intraocular lens was implanted in the left eye associated to relaxing limbal incisions trying to reduce corneal astigmatism. The near and distance postoperative visual acuity were worse than expected, with no improvement with refraction. Apparently, no other reason apart from irregular astigmatism/multifocal lens justified the low vision. After 45 days, with no visual acuity improvement, the intraocular lens was explanted and a monofocal one was implanted. The final corrected visual acuity improved. Thus, the present case emphasizes the need of a correct preoperative selection of patients to implant this type of multifocal lens, with special attention to corneal topography data.


Subject(s)
Aged , Humans , Male , Astigmatism/surgery , Lenses, Intraocular , Visual Acuity/physiology , Astigmatism/physiopathology , Corneal Topography , Lens Implantation, Intraocular , Preoperative Care , Reoperation
17.
Arq. bras. oftalmol ; 70(4): 609-614, jul.-ago. 2007. ilus, tab
Article in Portuguese | LILACS | ID: lil-461949

ABSTRACT

OBJETIVOS: Avaliar a eficácia das incisões periféricas relaxantes limbares (IPRL) na redução do astigmatismo pré-operatório durante a cirurgia de catarata. MÉTODOS: Foram estudados prospectivamente 103 olhos de 103 pacientes submetidos as IPRL, utilizando o nomograna de Nichamin durante a cirurgia de catarata pela facoemulsificação. Após o 1° e 6° mês foram avaliadas as mudanças no astigmatismo topográfico, na indução do astigmatismo e no índice de sucesso. Os pacientes foram separados em dois grupos segundo o tipo de astigmatismo no pré-operatório (a favor da regra e contra a regra) e estudados separadamente. RESULTADOS: Ocorreram diferenças estatisticamente significativas entre os valores dos astigmatismos topográficos no pré e pós-operatório nos dois grupos. Verificou-se indução de 1,10 ± 0,9 dioptrias e 37 por cento de índice de sucesso no grupo de astigmatismo a favor da regra e 1,70 ± 0,80 dioptrias e 51 por cento de índice de sucesso no grupo de astigmatismo contra a regra após o 6° mês de seguimento. CONCLUSÃO: A incisão periférica relaxante limbar é efetiva na redução do astigmatismo pré-existente durante a cirurgia da catarata. O procedimento mostrou ser seguro e de fácil realização. O nomograma de Nichamim na nossa experiência hipocorrige o astigmatismo planejado em ambos os grupos estudados.


PURPOSE: To evaluate the effect of peripheral limbar relaxing incisions (PLRI) in the reduction of the astigmatism during cataract surgery. METHODS: We studied prospectively 103 eyes of 103 patients submitted to PLRI, using the Nichamim nomogram during cataract surgery by phacoemulsification. After the first and sixth month we analized the changes in astigmatism topography, induction of astigmatism and sucess rate. The patients were divided into two groups according to the astigmatism (with-the-rule and against-the-rule), and studied separately. RESULTS: There was a statistically significant change in the mean astigmatism topography in the preoperative and postoperative periods in both groups. There was an induction of 1.10 ± 0.9 D and 37 percent of sucess rate in the with-the-rule group and 1.70 ± 0.80 D and 51 percent of sucess rate in the against-the-rule group after six months of follow-up. CONCLUSIONS: The peripherical relaxing limbal incisions (PLRI) are effective in reducing the preoperative astigmatism during cataract surgery. The procedure is safe and easy. The Nichamin nomogram caused hypocorrection in both types of preoperative astigmatism.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Astigmatism/surgery , Cataract Extraction , Corneal Topography/methods , Astigmatism/physiopathology , Linear Models , Limbus Corneae/surgery , Nomograms , Phacoemulsification , Prospective Studies , Refraction, Ocular/physiology , Time Factors
18.
Arq. bras. oftalmol ; 70(2): 225-228, mar.-abr. 2007. graf
Article in Portuguese | LILACS | ID: lil-453160

ABSTRACT

OBJETIVOS: Avaliar o efeito da facoemulsificação com incisão em córnea clara no meridiano mais curvo sobre a magnitude do astigmatismo ceratométrico pré-operatório. Mapear a magnitude do astigmatismo cirurgicamente induzido por incisões nas posições nasal (N), temporal (T), temporal superior (TS) e temporal inferior (TI). MÉTODOS: Foi realizado estudo ceratométrico prospectivo em 48 olhos de 48 pacientes, submetidos a facoemulsificação com incisão do meridiano mais curvo. As medidas ceratométricas foram realizadas no pré-operatório e um mês após a realização da cirurgia. O astigmatismo cirurgicamente induzido foi determinado pelo método das coordenadas retangulares em 10 passos, modificado. RESULTADOS: Foram operados 21 olhos direitos e 27 olhos esquerdos e, de acordo com a posição das incisões em córnea clara, foram divididos em: 16 olhos N, 4 olhos T, 22 olhos TS, 6 olhos TI. A média da ametropia cilíndrica pré-operatória foi de 1,06D ± 0,65 e a pós-operatória de 0,89D ± 0,80. Houve diminuição estatisticamente significativa no astigmatismo corneal preexistente (p=0,016). A média total de astigmatismo cirurgicamente induzido foi de 0,94D ± 0,56. Em relação aos grupos o astigmatismo cirurgicamente induzido foi de 1,06D ± 0,66 em N, 0,87D ± 0,20 em T, 0,95D ± 0,55 em TS e 0,61D ± 0,25 em TI. Não houve diferença estatística com relação ao astigmatismo cirurgicamente induzido nos grupos N, T, TS e TI (p=0,426). CONCLUSÃO: A técnica se mostrou efetiva na redução do astigmatismo ceratométrico pré-operatório. A média do astigmatismo cirurgicamente induzido foi de 1,06D ± 0,66 em N, 0,95D ± 0,55 em TS, 0,61D ± 0,25 em T e 0,87D ± 0,20 em TI.


PURPOSE: To evaluate the effect of phacoemulsification through clear cornea incision in the steepest meridian (ISM), on the magnitude of preoperative keratometric astigmatism. To map the magnitude of surgically induced astigmatism (SIA) by clear cornea incision in the positions: nasal (N), temporal (T), superior temporal (ST) and inferior temporal (IT). METHODS: A prospective keratometric study was performed in 48 eyes of 48 patients, submitted to phacoemulsification by incision in the steepest meridian. Keratometric measures were taken preoperatively and one month after surgery. Surgically induced astigmatism was determined by the rectangular coordinate by the modified ten-step method. RESULTS: There were 21 right eyes and 27 left eyes submitted to surgery, 16 eyes being N, 4 eyes T, 22 eyes TS, and 6 eyes TI. The average preoperative and postoperative cylindrical ametropias were, respectively, 1.06 ± 0.65 D and 0.89 ± 0.80 D. We found a statistical difference regarding decrease in the preoperative keratometric astigmatism (p=0.016). The total average of the surgically induced astigmatism was 0.94 ± 0.56 D. In relation to the groups, surgically induced astigmatism was 1.06 ± 0.66 D in N, 0.87 ± 0.20 D in T, 0.95 ± 0.55 D in TS and 0.61 ± 0.25 D in TI. There was no statistical difference in the surgically induced astigmatism between these groups (p=0.426). CONCLUSION: The technique was shown to be effective in decreasing the preoperative keratometric astigmatism. The surgically induced astigmatism was 1.06 ± 0.66 D in N, 0.95 ± 0.55 D in TS, 0.61 ± 0.25 D in T and 0.87 ± 0.20 D in TI.


Subject(s)
Humans , Male , Female , Middle Aged , Astigmatism/etiology , Astigmatism/physiopathology , Cornea/surgery , Phacoemulsification/adverse effects , Phacoemulsification/methods , Analysis of Variance , Astigmatism/surgery , Corneal Topography , Cataract/therapy , Lens Implantation, Intraocular , Preoperative Care , Prospective Studies , Severity of Illness Index , Statistics, Nonparametric
19.
Arq. bras. oftalmol ; 70(2): 247-254, mar.-abr. 2007. tab, graf
Article in Portuguese | LILACS | ID: lil-453164

ABSTRACT

OBJETIVOS: Avaliar o desempenho visual e o conforto de lentes de contato de material híbrido, quanto ao apresentado por pacientes portadores de ceratocone e astigmatismo miópico composto, e comparar com a lente de contato rígida-gás-permeável nos dois grupos de pacientes. MÉTODOS: Foram submetidos à adaptação com lentes de contato 22 pacientes, sendo 8 portadores de astigmatismo miópico composto e 14 com diagnóstico de ceratocone. Entre os pacientes, 7 eram do sexo masculino e 15 do feminino, com idade média de 32,13 anos ± 8,12. Cada paciente recebeu uma lente de contato de material híbrido e, no contralateral, uma lente rígida-gás-permeável. A escolha da lente a ser adaptada no olho direito ou esquerdo foi feita aleatoriamente, sendo o trabalho duplo-mascarado. Os pacientes foram submetidos aos seguintes exames: medida do conforto por meio da escala visual analógica, tempo de ruptura do filme lacrimal, acuidade visual pela escala de Bailey-Lovie adaptada para quatro metros, sensibilidade ao contraste pelo "functional acuity contrast test" e análise das aberrações oculares pela análise de frentes de onda. RESULTADOS: Com relação ao conforto não houve associação com o tipo de lente (p=0,350). Houve variação no conforto referido ao longo do tempo até 7 dias (p=0,001), estabilizando-se após este período. A medida da acuidade visual sofreu aumento entre a adaptação e a medida obtida aos 7 dias, bem como desta para a medida de 15 dias, estabilizando-se então. A acuidade visual não apresentou diferenças com relação ao tipo de lente estudada. Verificou-se que não houve diferença no tempo de ruptura do filme lacrimal (p=0,989) com relação aos tipos de lentes, porém houve diminuição deste (p=0,001) quando comparadas as medidas antes do início do uso das lentes e com dois meses de uso. Os tipos de lentes não revelaram associação com a sensibilidade ao contraste e não diferiram das medidas feitas com o uso de óculos, exceto para a freqüência...


PURPOSE: To evaluate comfort and visual performance in relation to two different used contact lens types: hybrid material (HM) and rigid-gas-permeable (RGP), in patients with regular myopic astigmatism and with keratoconus. METHODS: A randomized, double masked, prospective study of 22 patients with the diagnosis of myopic astigmatism (8 with myopic astigmatism and 14 with keratoconus) was conducted. Fifteen patients were female and 7 were male, and mean age was: 32.13 ± 8.12 years. In one of the eyes a rigid-gas-permeable contact lens was adapted (DK 30), and in the other a hybrid material contact lens was adapted (DK 23). All patients were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, tear break-up time, best corrected visual acuity with the Bailey-Lovie scale adapted for 4 meters, functional acuity contrast test (FACT) and wavefront analysis. RESULTS: In relation to comfort, there was no association with the evaluated contact lens type (p=0.350). There was a variation in comfort level during the first 7 days. The visual acuity increased between the 7th and the 15th day of adaptation. Visual acuity stabilized right after this period. The visual acuity did not show differences in relation to the studied lens type. It was verified that there was no difference in the tear break-up time (p=0.989) in relation to the studied lenses type and there was a decrease in the tear break-up time (p=0.001) when we compared the measurement before the use of the lenses and 2 months after their use. There was no difference in contrast sensitivity in the used lens type and between each type and the use of glasses (p<0.047). High order aberrations decreased significantly when comparing patients with and without contact lenses, except for spherical and coma aberrations (p=0.394). CONCLUSION: Comfort and visual performance when comparing hybrid material and rigid-gas-permeable contact lenses...


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Astigmatism/therapy , Contact Lenses , Keratoconus/therapy , Myopia/therapy , Visual Acuity/physiology , Astigmatism/physiopathology , Contact Lenses, Hydrophilic , Corneal Topography , Contrast Sensitivity/physiology , Epidemiologic Methods , Eyeglasses , Keratoconus/physiopathology , Myopia/physiopathology , Prosthesis Fitting , Refraction, Ocular/physiology , Time Factors , Treatment Outcome , Tears/metabolism
20.
Arq. bras. oftalmol ; 70(2): 290-297, mar.-abr. 2007. tab, graf
Article in Portuguese | LILACS | ID: lil-453171

ABSTRACT

OBJETIVO: Avaliar a relação entre aberrações de alta ordem e erros de refração e a relação entre aberrações de alta ordem e a idade. MÉTODOS: Realizou-se estudo retrospectivo analítico, de pacientes submetidos a exames de aberrometria. Foram incluídos neste estudo todos os indivíduos examinados com aberrômetro LadarWave® (Alcon, Fort Worth, Texas), no Hospital de Olhos do Paraná (Curitiba - Paraná) no período de abril de 2004 a abril de 2005, sendo o principal critério de inclusão acuidade visual corrigida ou não de 20/20 ou melhor e o principal critério de exclusão presença de cirurgia e/ou doença ocular prévia. Foram estudadas as seguintes variáveis: idade, grau de refração esféro-cilíndrica, medida do equivalente esférico, aberrações de alta ordem divididas em: coma, aberração esférica, outras e "root mean square" (RMS) de alta ordem. Todas as variáveis foram obtidas com exame de aberrometria realizado no aberrômetro LadarWave®, sob cicloplegia, considerando-se pupila de 6,5 mm. Foram avaliadas aberrações ópticas de alta ordem até a oitava ordem nos polinômios de Zernike. Os pacientes foram divididos em 6 grupos de acordo com o vício de refração e em 3 grupos de acordo com a idade. RESULTADOS: Foram avaliados no período estudado 312 olhos dos quais 201 foram incluídos no estudo. A idade média desses pacientes foi de 33,9 ± 10,1 anos variando de 7 a 62 anos. Na comparação geral entre os grupos de acordo com o vício de refração, foi observado que os pacientes hipermétropes com astigmatismo inferior a -0,75 D (Grupo 5) apresentaram maior quantidade de aberração esférica, e que os pacientes hipermétropes com astigmatismo superior a -0,75 D (Grupo 6) apresentaram maior quantidade de aberrações denominadas "outras" e RMS de alta ordem. Na comparação geral entre os grupos de idade, em relação as variáveis estudadas, o grupo de pacientes com 45 ou mais anos (Grupo C) apresentou maior quantidade de todas as aberrações estudadas. CONCLUSÕES:...


PURPOSE: To evaluate the relationship between high-order aberrations and refractive errors, and between high-order aberrations and age. METHODS: An analytic retrospective study of patients that underwent aberrometry examination was conducted. All subjects examined with LadarWave® aberrometer at the Hospital de Olhos do Paraná from April 2004 to April 2005 were included in this study. The major inclusion criterion was 20/20 or better - corrected or not - visual acuity; and the major exclusion criterion, the presence of previous eye surgery or disease. The following variables were analyzed: age, refraction, spherical equivalent, and high-order aberrations wich were: coma, spherical aberration, others, and high-order root mean square (RMS). All data were obtained by LadarWave® aberrometry examination, under cycloplegia, utilizing only 6.5 mm pupil results. High-order aberrations up to eight order Zernike's coefficients were evaluated. Patients were divided into 6 groups according to refraction error and into 3 groups according to age. RESULTS: Two hundred and one of 312 eyes were studied. The mean age was 33.9 ± 10.1, varying from 7 to 62 years of age. Among the refraction error groups hyperopic patients with less than -0.75 D astigmatism (Group 5) showed a higher amount of spherical aberration, and hyperopic patients with more than -0.75 D astigmatism (Group 6) showed a higher amount of other and high-order RMS aberrations. In the general comparison between the age groups, the 45 or older group (Group C) showed a higher amount of all the analyzed aberrations. CONCLUSION: a) There was a statistically significant positive relationship between hyperopia - with or without astigmatism - and spherical aberration and high-order RMS. b) There was a statistically significant positive relationship between age and all analyzed aberrations.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Contrast Sensitivity/physiology , Refraction, Ocular/physiology , Refractive Errors/physiopathology , Age Distribution , Age Factors , Astigmatism/physiopathology , Brazil/epidemiology , Diagnostic Techniques, Ophthalmological , Epidemiologic Methods , Mydriatics/administration & dosage , Pupil/physiology , Severity of Illness Index , Sex Distribution , Visual Acuity
SELECTION OF CITATIONS
SEARCH DETAIL