Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Prensa méd. argent ; 107(1): 47-51, 20210000. tab
Article in English | LILACS, BINACIS | ID: biblio-1362208

ABSTRACT

Objective: The normal morphology of femoral anteversion is an essential factor which determines the clinical results of hip replacement to achieve the normal activity and the length of the replaced joint. No previous study has been documented regarding normal value of femoral anteversion in Indonesian population and how they are different with Western, India and African population. This study aimed on measurement of normal femoral anteversion values of Indonesian population and compare it with existing data of Western, African and India values. Method: This cross-sectional study by measuring the femoral neck anteversion angle in 120 samples of Indonesians's cadaveric femur. Comparisons were made between Western, African and India. Result: The result showed that the average values of femoral neck anteversion angle in men were 11.60 ± 4.83 and 12.96 ± 5.1 in the right and left parts respectively, while in women, the results were 14.83+-5.14 and 13.37+-5.66 in right and left parts. The p value of ≤ 0.05 was considered to be significant. Conclusion: The mean femoral anteversion values of Indonesian population is 13.22. It is significantly different in comparison with Western, African, and Indian population.


Subject(s)
Humans , Population/genetics , Reference Values , Cadaver , Cross-Sectional Studies/statistics & numerical data , Femur , Femur Neck/growth & development , Bone Anteversion/pathology
3.
Annals of Rehabilitation Medicine ; : 137-144, 2018.
Article in English | WPRIM | ID: wpr-739814

ABSTRACT

OBJECTIVE: To evaluate femoral anteversion angle (FAA) change in children with intoeing gait depending on age, gender, and initial FAA using three-dimensional computed tomography (3D-CT). METHODS: The 3D-CT data acquired between 2006 and 2016 were retrospectively reviewed. Children 4 to 10 years of age with symptomatic intoeing gait with follow-up interval of at least 1 year without active treatment were enrolled. Subjects were divided into three groups based on age: group 1 (≥4 and <6 years), group 2 (≥6 and <8 years), and group 3 (≥8 and <10 years). Initial and follow-up FAAs were measured using 3D-CT. Mean changes in FAAs were calculated and compared. RESULTS: A total of 200 lower limbs of 100 children (48 males and 52 females, mean age of 6.1±1.6 years) were included. The mean follow-up period was 18.0±5.4 months. Average initial and follow-up FAA in children with intoeing gait was 31.1°±7.8° and 28.9°±8.2°, respectively. The initial FAA of group 1 was largest (33.5°±7.7°). Follow-up FAA of group 1 was significantly reduced to 28.7°±9.2° (p=0.000). FAA changes in groups 1, 2, and 3 were −6.5°±5.8°, −6.4°±5.1°, and −5.3°±4.0°, respectively. These changes of FAA were not significantly (p=0.355) different among the three age groups. However, FAA changes were higher (p=0.012) in females than those in males. In addition, FAA changes showed difference depending on initial FAA. When initial FAA was smaller than 30°, mean FAA change was −5.6°±4.9°. When initial FAA was more than 30°, mean FAA change was −6.8°±5.4° (p=0.019). CONCLUSION: FAA initial in children with intoeing gait was the greatest in age group 1 (4–6 years). This group also showed significant FAA decrease at follow-up. FAA changes were greater when the child was a female, younger, and had greater initial FAA.


Subject(s)
Child , Female , Humans , Male , Bone Anteversion , Follow-Up Studies , Gait , Imaging, Three-Dimensional , Lower Extremity , Retrospective Studies
4.
Annals of Rehabilitation Medicine ; : 277-285, 2018.
Article in English | WPRIM | ID: wpr-714273

ABSTRACT

OBJECTIVE: To find factors affecting hip and femoral deformities in children with spastic cerebral palsy (CP) by comparing various clinical findings with imaging studies including plain radiography and computed tomography (CT) imaging. METHODS: Medical records of 709 children with spastic CP who underwent thorough baseline physical examination and functional assessment between 2 to 6 years old were retrospectively reviewed. Fifty-seven children (31 boys and 26 girls) who had both plain radiography of the hip and three-dimensional CT of the lower extremities at least 5 years after baseline examination were included in this study. RESULTS: The mean age at physical examination was 3.6 years (SD=1.6; range, 2–5.2 years) and the duration of follow-up imaging after baseline examination was 68.4 months (SD=22.0; range, 60–124 months). The migration percentage correlated with motor impairment and the severity of hip adductor spasticity (R1 angle of hip abduction with knee flexion). The femoral neck and shaft angle correlated with the ambulation ability and severity of hip adductor spasticity (R1 and R2 angles of hip abduction with both knee flexion and extension). CONCLUSION: Hip subluxation and coxa valga deformity correlated with both dynamic spasticity and shortening of hip adductor muscles. However, we found no correlation between femoral deformities such as femoral anteversion, coxa valga, and hip subluxation.


Subject(s)
Child , Humans , Bone Anteversion , Cerebral Palsy , Congenital Abnormalities , Coxa Valga , Femur Neck , Follow-Up Studies , Hip Dislocation , Hip , Knee , Lower Extremity , Medical Records , Muscle Spasticity , Muscles , Physical Examination , Radiography , Retrospective Studies , Walking
5.
Annals of Rehabilitation Medicine ; : 441-449, 2017.
Article in English | WPRIM | ID: wpr-49269

ABSTRACT

OBJECTIVE: To develop and test the validity and reliability of a new instrument for measuring the thigh-foot angle (TFA) for the patients with in-toeing and out-toeing gait. METHODS: The new instrument (Thigh-Foot Supporter [TFS]) was developed by measuring the TFA during regular examination of the tibial torsional status. The study included 40 children who presented with in-toeing and out-toeing gaits. We took a picture of each case to measure photographic-TFA (P-TFA) in the proper position and to establish a criterion. Study participants were examined by three independent physicians (A, B, and C) who had one, three and ten years of experience in the field, respectively. Each examiner conducted a separate classical physical examination (CPE) of every participant using a gait goniometer followed by a TFA assessment of each pediatric patient with or without the TFS. Thirty minutes later, repeated in the same way was measured. RESULTS: Less experienced examiner A showed significant differences between the TFA values depending on whether TFS used (left p=0.003 and right p=0.008). However, experienced examiners B and C did not show significant differences. Using TFS, less experienced examiner A showed a high validity and all examiner's inter-test and the inter-personal reliabilities increased. CONCLUSION: TFS may increase validity and reliability in measuring tibial torsion in patients who has a rotational problem in lower extremities. It would be more useful in less experienced examiners.


Subject(s)
Child , Humans , Bone Anteversion , Gait , Lower Extremity , Physical Examination , Reproducibility of Results , Torsion Abnormality
6.
Annals of Rehabilitation Medicine ; : 104-112, 2017.
Article in English | WPRIM | ID: wpr-18253

ABSTRACT

OBJECTIVE: To investigate the efficacy of portable microcurrent therapy device (PMTD) of the hip internal rotators in the treatment of in-toeing gait caused by increased femoral anteversion in children over 8 years of age. METHODS: Eleven children (22 legs; 4 boys and 7 girls; mean age, 10.4±1.6 years) with in-toeing gait caused by increased femoral anteversion were included in the present study. All children received 60 minutes of PMTD (intensity, 25 µA; frequency, 8 Hz) applied to the hip internal rotators daily for 4 weeks. Hip internal rotation (IR) angle, external rotation (ER) angle, and midmalleolar-second toe angle (MSTA) measurement during stance phase at transverse plane and Family Satisfaction Questionnaire, frequency of tripping and fatigue like pains about the PMTD were performed before treatment and at 4 weeks after initial PMTD treatment. Paired t-test and Fisher exact test were used for statistical analysis. RESULTS: Hip IR/ER/MSTA was 70.3°±5.4°/20.1°±5.5°/–11.4°±2.7°, and 55.7°±7.8°/33.6°±8.2°/–2.6°±3.8° before treatment and at 4 weeks after initial PMTD treatment, respectively (p<0.01). Ten of 11 (91%) children's family stated that they were generally satisfied with the PMTD treatment. The frequency of tripping and fatigue like pains was significantly lower at 4 weeks after PMTD treatment (p<0.05). Excellent inter-rater and intra-rater reliability was observed for repeated MSTA measurements between the examiners (k=0.91–0.96 and k=0.93–0.99), respectively. CONCLUSION: PMTD of the hip internal rotators can be effective in improving the gait pattern of children with in-toeing gait caused by increased femoral anteversion.


Subject(s)
Child , Female , Humans , Bone Anteversion , Electric Stimulation Therapy , Fatigue , Gait , Hip , Leg , Pilot Projects , Toes
7.
Annals of Rehabilitation Medicine ; : 237-243, 2016.
Article in English | WPRIM | ID: wpr-39561

ABSTRACT

OBJECTIVE: To assess the intra-rater and inter-rater reliability for measuring femoral anteversion angle (FAA) by a radiographic method using three-dimensional computed tomography reconstruction (3D-CT). METHODS: The study included 82 children who presented with intoeing gait. 3D-CT data taken between 2006 and 2014 were retrospectively reviewed. FAA was measured by 3D-CT. FAA is defined as the angle between the long axis of the femur neck and condylar axis of the distal femur. FAA measurement was performed twice at both lower extremities by each rater. The intra-rater and inter-rater reliability were calculated by intraclass correlation coefficient (ICC). RESULTS: One hundred and sixty-four lower limbs of 82 children (31 boys and 51 girls, 6.3±3.2 years old) were included. The ICCs of intra-rater measurement for the angle of femoral neck axis (NA) were 0.89 for rater A and 0.96 for rater B, and those of condylar axis (CA) were 0.99 for rater A and 0.99 for rater B, respectively. The ICC of inter-rater measurement for the angle of NA was 0.89 and that of CA was 0.92. By each rater, the ICCs of the intrarater measurement for FAA were 0.97 for rater A and 0.95 for rater B, respectively and the ICC of the inter-rater measurement for FAA was 0.89. CONCLUSION: The 3D-CT measures for FAA are reliable within individual raters and between different raters. The 3D-CT measures of FAA can be a useful method for accurate diagnosis and follow-up of femoral anteversion.


Subject(s)
Child , Female , Humans , Axis, Cervical Vertebra , Bone Anteversion , Diagnosis , Femur , Femur Neck , Follow-Up Studies , Gait , Imaging, Three-Dimensional , Lower Extremity , Retrospective Studies
8.
Chinese Medical Journal ; (24): 1584-1591, 2016.
Article in English | WPRIM | ID: wpr-251336

ABSTRACT

<p><b>BACKGROUND</b>The accurate measurement of the femoral anteversion (FA) angle is always a topic of much debate in the orthopedic surgery and radiology research. We aimed to explore a new FA measurement method to acquire accurate results without radiation damage using piglet model.</p><p><b>METHODS</b>A total of thirty piglets were assigned to two groups based on the age. Bilateral femora were imaged with 3.0-T magnetic resonance (MR) and 64-slice computed tomography (CT) examinations on all piglets. FA was measured on MR-three-dimensional (3D) postprocessing software with a four-step method: initial validation of the femoral condylar axis, validation of the condylar plane, validation of the femoral neck axis, and line-plane angle measurement of FA. After MR and CT examinations, all piglets were sacrificed and their degree of FA was measured using their excised, dried femora. MR, CT, and dried-femur measurement results were analyzed statistically; MR and CT measurements were compared for accuracy against each other and against the gold standard dried femur measurement.</p><p><b>RESULTS</b>In both groups, the mean FA value measured by MR was lower than that measured by CT. A statistically significant difference was observed between CT- and dried-femur measurements but not between MR- and dried-femur measurements. A higher correlation (0.783 vs. 0.408) and a higher consistency (0.863 vs. 0.578) with dried-femur measurement results were seen for MR measurements than CT measurements in the 1-week age group. However, in the 8-week age group, similar correlations (0.707 vs. 0.669) and consistencies (0.864 vs. 0.821) were observed.</p><p><b>CONCLUSIONS</b>Noninvasive MR-3D-Cube reconstruction was able to accurately measure FA in piglets. Particularly in the 1-week age group with a larger proportion of cartilaginous structures, the correlation and consistency between MR- and dried-femur measurement results were higher than those between CT- and dried-femur measurements, suggesting that MR may be a new useful examination tool for FA-related diseases in children.</p>


Subject(s)
Animals , Bone Anteversion , Diagnosis , Femur Neck , Pathology , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Methods , Swine , Tomography, X-Ray Computed
9.
Yonsei Medical Journal ; : 225-231, 2016.
Article in English | WPRIM | ID: wpr-220778

ABSTRACT

PURPOSE: To identify the accuracy of postoperative implant alignment in minimally invasive surgery total knee arthroplasty (MIS-TKA), based on the degree of varus deformity. MATERIALS AND METHODS: The research examined 627 cases of MIS-TKA from November 2005 to December 2007. The cases were categorized according to the preoperative degree of varus deformity in the knee joint in order to compare the postoperative alignment of the implant: less than 5degrees varus (Group 1, 351 cases), 5degrees to less than 10degrees varus (Group 2, 189 cases), 10degrees to less than 15degrees varus (Group 3, 59 cases), and 15degrees varus or more (Group 4, 28 cases). RESULTS: On average, the alignment of the tibial implant was 0.2+/-1.4degrees, 0.1+/-1.3degrees, 0.1+/-1.6degrees, and 0.3+/-1.7degrees varus, and the tibiofemoral alignment was 5.2+/-1.9degrees, 4.7+/-1.9degrees, 4.9+/-1.9degrees, and 5.1+/-2.0degrees valgus for Groups 1, 2, 3, and 4, respectively, in the preoperative stage, indicating no difference between the groups (p>0.05). With respect to the accuracy of the tibial implant alignment, 98.1%, 97.6%, 87.5%, and 86.7% of Groups 1, 2, 3, and 4, respectively, had 0+/-3degrees varus angulation, demonstrating a reduced level of accuracy in Groups 3 and 4 (p0.05). CONCLUSION: Satisfactory component alignment was achieved in minimally invasive surgery in total knee arthroplasty, regardless of the degree of varus deformity.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee/methods , Bone Anteversion/complications , Bone Malalignment/etiology , Joint Deformities, Acquired/surgery , Knee Joint/diagnostic imaging , Knee Prosthesis , Minimally Invasive Surgical Procedures/methods , Osteoarthritis, Knee/complications , Postoperative Period , Preoperative Period , Range of Motion, Articular , Tibia/surgery , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL