Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Clinics in Orthopedic Surgery ; : 191-201, 2011.
Article in English | WPRIM | ID: wpr-102718

ABSTRACT

BACKGROUND: Injectable calcium sulfate is a clinically proven osteoconductive biomaterial, and it is an injectable, resorbable and semi-structural bone graft material. The purpose of this study was to validate the clinical outcomes of injectable calcium sulfate (ICS) grafts as compared with those of a demineralized bone matrix (DBM)-based graft for filling in contained bony defects created by tumor surgery. METHODS: Fifty-six patients (41 males and 15 females) with various bone tumors and who were surgically treated between September 2003 and October 2007 were included for this study. The patients were randomly allocated into two groups, and either an ICS graft (28 patients) or a DBM-based graft (28 patients) was implanted into each contained defect that was developed by the surgery. The radiographic outcomes were compared between the two groups and various clinical factors were included for the statistical analysis. RESULTS: When one case with early postoperative pathologic fracture in the DBM group was excluded, the overall success rates of the ICS and DBM grafting were 85.7% (24/28) and 88.9% (24/27) (p > 0.05), respectively. The average time to complete healing was 17.3 weeks in the ICS group and 14.9 weeks in the DBM group (p > 0.05). Additionally, the ICS was completely resorbed within 3 months, except for one case. CONCLUSIONS: Although the rate of resorption of ICS is a concern, the injectable calcium sulfate appears to be a comparable bone graft substitute for a DBM-based graft, with a lower cost, for the treatment of the bone defects created during surgery for various bone tumors.


Subject(s)
Adolescent , Adult , Child , Child, Preschool , Female , Humans , Infant , Male , Middle Aged , Young Adult , Absorbable Implants , Biocompatible Materials/administration & dosage , Bone Demineralization Technique , Bone Matrix/transplantation , Bone Neoplasms/diagnostic imaging , Bone Substitutes/administration & dosage , Calcium Sulfate/administration & dosage , Curettage , Injections , Wound Healing
2.
Arq. odontol ; 46(1): 17-21, 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-583636

ABSTRACT

Este estudo avaliou o comportamento mecânico de uma resina de poliuretano Quartz-die (Zermack - Itália) empregada na modelagem odontológica comparando-a com o gesso tipo IV Durone (Dentsply - Brasil). Uma matriz metálica moldada com silicona de condensação Speedex (Coltène - Suiça) proporcionou corpos de prova com 12mm de altura por 6mm de diâmetro. Oito corpos de prova em resina de poliuretano e oito em gesso tipo IV (Durone) foram submetidos a ensaio de compressão na máquina de ensaios universal EMIC DL 2000, com célula de carga de 2000Kgf e velocidade de 0,05mm/min. Oito corpos de prova em resina de poliuretano e oito em gesso tipo IV obtidos a partir de uma matriz metálica hexagonal foram ensaiados noDurômetro Sussen Wolpert tipo Testor HTl, empregando penetrador esférico de 12,7mm, estabelecendo valores para dureza Rockwell. Os valores obtidos foram submetidos ao teste não-paramétrico de Kruskall-Walliscom p<0,05. Dentro dos parâmetros adotados neste estudo pôde-se concluir que a resina de poliuretano Quartz-die apresentou menor resistência à compressão e menor dureza superficial que o gesso tipo IV Durone.


Subject(s)
Dental Impression Materials/analysis , Resins, Synthetic/analysis , Calcium Sulfate/administration & dosage , Hardness Tests/methods
3.
Braz. j. biol ; 66(2a): 493-502, May 2006. tab, graf
Article in English | LILACS | ID: lil-431537

ABSTRACT

O objetivo deste estudo foi investigar o efeito da densidade, duração e do uso de aditivos na água durante o transporte de juvenis de tambaqui (Colossoma macropomum) e usar estes resultados para estabelecer um protocolo seguro de transporte para esta espécie. Os produtos testados e suas doses foram: sal de mesa (1000, 2000 e 3000 mg/L), gesso (100, 300 e 500 mg/L) e benzocaína (10, 20 e 30 mg/L). Os peixes foram transportados em sistema fechado (saco plástico) em diferentes densidades e por diferentes tempos por até 24 h de transporte. A sobrevivência e os parâmetros de qualidade da água foram monitorados imediatamente após o transporte. Os peixes que sobreviveram ao transporte foram colocados em tanques-rede para avaliar a mortalidade após 96 h. A melhor densidade, tempo de transporte e aditivo foram estimados por modelo linear geral. O efeito do fator de condição na sobrevivência após o transporte e na sobrevivência de 96 h também foi avaliado. Como esperado, a sobrevivência após o transporte e a sobrevivência de 96 h foram significativamente correlacionados com o tempo e a densidade. A sobrevivência após o transporte, mas não a sobrevivência de 96 h, também tem correlação com os aditivos testados. A sobrevivência após o transporte é significativamente igual para o tratamento controle e para os tratamentos que receberam gesso e significativamente menor para os tratamentos que receberam sal e benzocaína. O fator de condição não tem correlação com a sobrevivência após o transporte e a sobrevivência de 96 h. É conclusivo que os aditivos testados não melhoram a sobrevivência de juvenis de tambaqui após o transporte. Modelos lineares foram desenvolvidos para predizer a melhor densidade de transporte em função do tempo.


Subject(s)
Animals , Aquaculture/methods , Fishes , Transportation/standards , Water/standards , Benzocaine/administration & dosage , Calcium Sulfate/administration & dosage , Sodium Chloride/administration & dosage , Time Factors , Transportation/methods , Water/chemistry
4.
Ciênc. odontol. bras ; 6(1): 31-35, jan.-mar. 2003. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-407291

ABSTRACT

Neste estudo foram avaliados a estabilidade dimensional e a rugosidade superficial de espécimes em gesso tipo IV quando imersos em hipoclorito de sódio a 0,5 por cento e glutaraldeído alcalino a 2 por cento, ambos durante 10 minutos. A estabilidade dimensional foi mensurada por um programa de computador (Imagetools). As faces dos espécimes foram varridas e digitalizadas, e suas imagens mensuradas, enquanto a rugosidade foi registrada com o auxílio de um rugosímetro (T 1000 Hommel testing machine). Com base nos resultados dos testes físico-mecânicos realizados, e seus valores analisados estatisticamente, concluiu-se que os métodos usuais de desinfecção de modelos de gesso alteraram, por desgaste, as dimensões originais dos espécimes após a imersão nos dois desinfetantes. Esse desgaste, entretanto, não provocou uma alteração significante da rugosidade superficial


Subject(s)
Calcium Sulfate/administration & dosage , Calcium Sulfate/analysis , Disinfection/methods
5.
Rev. venez. cir. ortop. traumatol ; 31(1): 30-6, mar. 1999. tab
Article in Spanish | LILACS | ID: lil-264245

ABSTRACT

En este estudio observacional analítico prospectivo no concurrente, se revisaron 107 historias clínicas de pacientes con el diagnóstico de fractura diafisiaria de tibia, tratados en la Unidad de Ortopedia y Traumatología del Hospital Universitario de Los Andesdurante el período comprendido de enero de 1978 a diciembre 1994. En esta serie el promedio de edad fue de 26 años (rango entre 14 y 66 años), predominó el sexo masculino sobre el femenino con un 86,9 por ciento. El factor etiológico más frecuente correspondio a los accidentes de tránsito con el 84 por ciento de la serie. El tratamiento con yeso tipo sarmiento se realizó en 40 pacientes (40/107) con la placa DCP se trataron 33 pacientes (33/107); y (34/107) fueron tratados con el clavo endomedular simple convencional tipo Kuntscher. Se compararon los resultados de los diferentes tipos de tratamiento observándose: se tuvieron 42,5 por ciento (17/40) de resultados satisfactorios con el yeso tipo sarmiento y 57,5 por ciento de resultados no satisfactorios (23/40). El 48,5 por ciento (16/33) de los pacientes tratados con placas de comprensión dinámica (DCP) evolucionaron bien y el 51,5 por ciento (17/33) evolucionaron. El 76.5 por ciento (26/34) de los pacientes tratados con clavo endomedular evolucionaron satisfactorios mientras el 23,5 por ciento (8/33 evolucionaron insatisfactoriamente). Existe una asociación estadísticamente significativa entre el tratamiento con yeso tipo sarmiento y clavo endomedular simple convencional tipo kuntscher a favor de este último. También existe asociación estadísticamente significativa si se compra el clavo con la placa de compresión dinámica (DCP), evolucionando mejor los enclavamientos endomedulares. No existe diferencia estadísticamente significativa si se comparan las placas de comprensión dinámica (DCP) con el yeso sarmiento. Finalmente si se agrupan los tratamientos quirúrgicos (placa de comprensión dinámica más enclavamiento endomedular), y se compara con el tratamiento ortópedico no existe una diferencia estadísticamente significativa. Los resultados globales son de un 55,1 por ciento de resultados satisfactorio para los tres grupos de tratamiento contra un 44,9 por ciento de resultados no satisfactorios según criterios de evaluación propia


Subject(s)
Humans , Female , Male , Calcium Sulfate/administration & dosage , Calcium Sulfate/adverse effects , Diaphyses/anatomy & histology , Diaphyses/surgery , Fractures, Bone
6.
Rev. odontol. UNESP ; 12(1/2): 133-6, jan.-dez. 1983. tab
Article in Portuguese | LILACS, BBO | ID: lil-187476

ABSTRACT

O efeito da fluidez de uma soluçäo endurecedora na expansäo de presa do gesso pedra melhorado, foi estudado em 2 marcas comerciais usando-se espatulaçäo manual e mecânica e 4 diferentes líquidos de mistura: água de abastecimento, água mineral e duas soluçöes endurecedoras de fluidez diferentes. Foram usados 80 corpos de prova nos 4 grupos, formando 16 subgrupos. A expansäo média apresentou diferenças quanto ao tipo de espatulaçäo e o líquido usado, mas näo quanto à marca comercial. A expansäo média obtida com os diferentes líquidos apresentou a seguinte ordem soluçäo endurecedora fluída (0,1375), água de abastecimento (0,1078), água mineral (0,0999) e soluçäo endurecedora menos fluída (0,0782). É possível concluir que uma soluçäo endurecedora menos fluída diminui a expansäo de presa do gesso estudado


Subject(s)
Calcium Sulfate/administration & dosage , Calcium Sulfate/analysis , Dental Materials/analysis
7.
Rev. odontol. UNESP ; 11(1/2): 59-63, jan.-dez. 1982. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-187534

ABSTRACT

Determinou-se o ângulo de contacto formado pelos gessos comum, pedra e especial sobre diferentes materiais de moldagem comumente utilizados em prótese dental. Para a avaliaçäo deste ângulo foi utilizado um microscópio Carl Zeiss, com dispositivo apropriado para este fim. Os resultados mostraram que o ângulo de contacto, formado pelos diferentes tipos de gesso, depende do tipo de material de moldagem empregado, sendo este ângulo tanto menor quanto maior a quantidade de água requerida na mistura dos gessos


Subject(s)
Calcium Sulfate/administration & dosage , Calcium Sulfate/analysis , Dental Impression Materials/administration & dosage , Dental Impression Materials/analysis
8.
Rev. odontol. UNESP ; 11(1/2): 65-71, jan.-dez. 1982. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-187535

ABSTRACT

O autor investigou o efeito de uma soluçäo endurecedora sobre a expansäo de duas marcas comerciais de gesso pedra melhorado. Utilizando duas técnicas de manipulaçäo (manual a céu aberto e mecânica a vácuo) concluiu que os líquidos usados na espatulaçäo (água corrente e a soluçäo Gipsum-hardner) tiveram pronunciado efeito sobre a expansäo de presa dos gessos estudados. Constatou que a soluçäo endurecedora determinou uma expansäo de presa menor do que a água


Subject(s)
Calcium Sulfate/administration & dosage , Dental Impression Materials/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL