Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Arq. bras. oftalmol ; 82(1): 56-61, Jan.-Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-973867

ABSTRACT

ABSTRACT Purpose: The porcine eye is frequently used as a research model. This paper analyzes the effect of different storage methods on the transparency of pig crystalline lens. Methods: A spectral transmission curve (from 220 to 780 nm) for the crystalline lens was determined experimentally after storage in different conditions: saline solution, formalin, castor oil, and freezing at -80°C. The total transmission in the visible spectrum, which was used as an index of transparency, was calculated from these curves. For comparative purposes, fresh lenses were evaluated and used as controls. Results: Storing the porcine crystalline lens in saline solution or castor oil resulted in a transparency loss of approximately 10% after 24 h and storage in formalin resulted in a loss of nearly 30%. Storage by freezing at -80°C for 4 weeks maintained the transparency of the crystalline lens; the spectral transmission measured immediately after defrosting at room temperature coincided exactly with that of the freshly extracted lens. Conclusions: The transparency of porcine crystalline lens is affected by the storage method. The visible spectrum is the most affected, evidenced by the effect on the transparency and consequently the amount of light transmitted. The results show that freezing at -80°C maintains the transpa rency of the crystalline lens for at least 4 weeks.


RESUMO Objetivos: Olho de porco é frequentemente usa do como modelos de pesquisa. Este estudo analisa o efeito de di ferentes métodos de armazenamento na preservação da transparência do cristalino de porco. Métodos: Uma curva de transmissão espectral (de 220 até 780 nm) para o cristalino foi experimentalmente determinada após armazenamento em diferentes condições: solução salina, formol, óleo de mamona e congelamento a -80°C. Transmissão total do espectro visível, que foi usada como um índice de transparência foi calculada a partir dessas curvas. Para fins comparativos, lentes frescas foram avaliadas e usadas como controles. Resultados: O armazenamento do cristalino suíno em solução salina ou óleo de mamona resultou uma perda de transparência de aproximadamente 10% após 24 h e o armazenamento em formol resultou uma perda de quase 30%. O armazenamento por congelamento a -80°C durante 4 semanas manteve a transparência do cristalino; a transmissão espectral medida imediatamente após o descongelamen to à temperatura ambiente coincidiu exatamente com a da lente extraída recentemente. Conclusão: A transparência do cristalino suíno é afetada pelo método de armazenamento. O espectro visível é o mais afetado, evidenciado pelo efeito sobre a transparência e consequentemente a quantidade de luz transmitida. Os resultados mostram que o congelamento a -80°C mantém a transparência do cristalino suíno por pelo menos 4 semanas.


Subject(s)
Animals , Organ Preservation/methods , Lens, Crystalline/anatomy & histology , Reference Values , Spectrophotometry/instrumentation , Spectrophotometry/methods , Swine , Time Factors , Ultraviolet Rays , Castor Oil/chemistry , Reproducibility of Results , Models, Animal , Formaldehyde/chemistry , Freezing , Lens, Crystalline/physiology , Lens, Crystalline/diagnostic imaging , Light
2.
Acta cir. bras ; 32(2): 116-124, Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-837684

ABSTRACT

Abstract Purpose To evaluate the polymer doped rods behavior with bioactive glass and hydroxyapatite for possible application as a fracture fixing method. Methods Twenty eight Rattus norvegicus Wistar underwent bone defect for access to the femoral medullary canal and distributed into three experimental groups: group A - doped castor bean polymer with bioactive glass; group B - castor bean polymer and; group C - castor bean polymer doped with bioactive glass and hydroxyapatite. After 15 and 60 evaluation days, the femurs were removed and sent for histology and scanning electron microscopy. Results Initially mild and moderate inflammatory infiltrate is observed that decreases as time goes by, and the presence of connective tissue capsule around the graft in all groups. Regarding the biomaterials resorption little was observed. The implanted rods did not favor the osteoconductive process in the femoral medullary canal which was observed only in the C15 group. Conclusions The association of castor bean polymer, bioactive glass and hydroxyapatite was biocompatible and osteointegrable. The osteoconductive only occurred in the presence of hydroxyapatite and bioactive glass (C15 Group) and little biodegradation was observed.


Subject(s)
Animals , Rats , Biocompatible Materials/therapeutic use , Bone Regeneration , Castor Oil/chemistry , Durapatite/therapeutic use , Durapatite/chemistry , Femur , Fracture Fixation, Internal/methods , Glass/chemistry , Biocompatible Materials/chemistry , Random Allocation , Internal Fixators , Rats, Wistar , Models, Animal
3.
J. appl. oral sci ; 22(6): 496-501, Nov-Dec/2014. tab, graf
Article in English | LILACS, BBO | ID: lil-732584

ABSTRACT

Favorable results in the use of castor oil polyurethane (COP) as pulp capping, membrane material, sealer, mouthwash and in bone repair, associated with the fact that Ricinus communis is not derived from petroleum and it is abundant in Brazil, encourage researches in the development of luting agents. Objectives This study compared the flexural strength (FS) of a castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate (COP10) with RelyX ARC (RX) after mechanical cycling (MC) and distilled water storage. Material and Methods Sixty-four specimens (25x2x2 mm) were fabricated and divided into two groups, COP10 and RX (control). Each group was divided into 4 subgroups (n=8) according to the storage time, 24 hours (24 h) or 60 days (60 d), and the performance (MC+FS) or not (only FS) of the mechanical cycling test. The FS (10 kN; 0.5 mm/min) and MC tests (10,000 cycles, 5 Hz, 0.5 mm/min) were carried out using an MTS-810 machine. The data were analyzed using ANOVA (α=0.05). Results The obtained FS (MPa) values were: COP10 24h- 19.04±2.41; COP10 60d- 17.92±3.54; RX 24h- 75.19±3.43; RX 60d- 88.77±6.89. All the RX specimens submitted to MC fractured, while the values for COP10 after MC were as follows: COP10 24h- 17.90±1.87 and COP10 60d- 18.60±1.60. Conclusions A castor oil-containing dental luting agent with a weight percentage of 10% (wt%) of calcium carbonate is resistant to mechanical cycling without decreases in flexural strength. However, mean COP10 showed only about 25% of the RelyX ARC mean flexural strength. .


Subject(s)
Bisphenol A-Glycidyl Methacrylate/chemistry , Calcium Carbonate/chemistry , Castor Oil/chemistry , Dental Cements/chemistry , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Polyurethanes/chemistry , Analysis of Variance , Dental Stress Analysis , Immersion , Materials Testing , Pliability , Reference Values , Stress, Mechanical , Time Factors , Water/chemistry
4.
Rev. bras. cir. cardiovasc ; 29(2): 272-278, Apr-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-719402

ABSTRACT

Objective: The aim of the present investigation was to determine whether the difference in inflammatory tissue reaction between the Riccinus communis (castor) polymer with calcium carbonate and the titanium implant is statistically significant. Methods: Thirty-two Cavia porcellus were allocated into four groups of eight animals each. We implanted the two types of materials in the retroperitoneal space of all the animals. They were euthanized at 7, 20, 30 and 40 days after surgery, and an histological study of the samples was conducted. Results: All implants showed characteristics of chronic inflammation regardless of the material and timepoint of evaluation. There was no statistically significant difference between Pm+CaCO3 and Ti with regard to the presence of granulation tissue, tissue congestion, histiocytes, lymphocytes, neutrophils, giant cells, and fibrosis (P> 0.05). Conclusion: The castor oil polymer plus calcium carbonate implant was not statistically different from the titanium implant regarding inflammatory tissue reaction. .


Objetivo: Determinar se a reação tecidual do implante retroperitoneal do polímero de óleo de mamona com acréscimo de carbonato de cálcio (Pm+CaCO3) é significativa, por meio de análise histopatológica, tendo como controle o implante de titânio não tratado (Ti). Métodos: Estudo experimental, intervencionista e randomizado com 32 cobaias. Os animais foram separados em quatro grupos iguais e eutanasiados com 7, 20, 30 e 40 dias após o ato cirúrgico. Foram confeccionadas lâminas em hematoxilina-eosina e em tricrômio de Masson. Em relação a variáveis qualitativas dicotômicas, para análise da diferença entre o Pm+CaCO3 e o Ti em cada momento de avaliação foi usado o teste binomial. Considerando os materiais separadamente, a comparação dos quatro grupos foi feita utilizandose o teste exato de Fisher. Valores de P<0,05 indicaram significância estatística. Resultados: Todos os implantes apresentaram características de inflamação crônica, independente do material e do momento de avaliação. Não houve diferença estatisticamente significativa entre o Pm+CaCO3 e o Ti considerando a presença de tecido de granulação, congestão tecidual, histiócitos, linfócitos, neutrófilos, células gigantes e fibrose (P>0,05). Conclusão: Não foi encontrada diferença significativa entre a reação tecidual do Pm+CaCO3 e a do Ti. .


Subject(s)
Animals , Guinea Pigs , Male , Calcium Carbonate/pharmacology , Castor Oil/pharmacology , Polymers/pharmacology , Ricinus/chemistry , Subcutaneous Tissue/drug effects , Titanium/pharmacology , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Calcium Carbonate/chemistry , Castor Oil/chemistry , Granulation Tissue/drug effects , Implants, Experimental , Materials Testing , Models, Animal , Prostheses and Implants , Polymers/chemistry , Random Allocation , Reproducibility of Results , Subcutaneous Tissue/pathology , Time Factors , Titanium/chemistry
5.
J. appl. oral sci ; 20(1): 16-20, Jan.-Feb. 2012. ilus, tab
Article in English | LILACS | ID: lil-618147

ABSTRACT

The need to develop new dental luting agents in order to improve the success of treatments has greatly motivated research. OBJECTIVE: The aim of this study was to evaluate the diametral tensile strength (DTS) and film thickness (FT) of an experimental dental luting agent derived from castor oil (COP) with or without addition of different quantities of filler (calcium carbonate - CaCO3). MATERIAL AND METHODS: Eighty specimens were manufactured (DTS N=40; FT N=40) and divided into 4 groups: Pure COP; COP 10 percent; COP 50 percent and zinc phosphate (control). The cements were mixed according to the manufacturers' recommendations and submitted to the tests. The DTS test was performed in the MTS 810 testing machine (10 KN, 0.5 mm/min). For FT test, the cements were sandwiched between two glass plates (2 cm²) and a load of 15 kg was applied vertically on the top of the specimen for 10 min. The data were analyzed by means of one-way ANOVA and Tukey's test (α=0.05). RESULTS: The values of DTS (MPa) were: Pure COP- 10.94±1.30; COP 10 percent- 30.06±0.64; COP 50 percent- 29.87±0.27; zinc phosphate- 4.88±0.96. The values of FT (µm) were: Pure COP- 31.09±3.16; COP 10 percent- 17.05±4.83; COP 50 percent- 13.03±4.83; Zinc Phosphate- 20.00±0.12. One-way ANOVA showed statistically significant differences among the groups (DTS - p=1.01E-40; FT - p=2.4E-10). CONCLUSION: The experimental dental luting agent with 50 percent of filler showed the best diametral tensile strength and film thickness.


Subject(s)
Humans , Castor Oil/chemistry , Dental Cements/chemistry , Analysis of Variance , Calcium Carbonate/chemistry , Dental Materials , Dental Stress Analysis , Materials Testing , Tensile Strength
6.
Acta cir. bras ; 27(1): 56-62, Jan. 2012. ilus, tab
Article in English | LILACS | ID: lil-607997

ABSTRACT

PURPOSE: To evaluate the biologic behavior of the castor polymer containing silica nanoparticles as a bone substitute in diafisary defect. METHODS: Twenty seven male rattus norvegicus albinus wistar lineage were submitted to bone defect filled with castor oil polymer. Three experimental groups had been formed with nine animals each: (1) castor oil polymer containing only calcium carbonate; (2) castor oil polymer with calcium carbonate and doped with 5 percent of silica nanoparticles; (3) castor polymer with calcium carbonate doped with 10 percent of silica nanoparticles; 3 animals of each group were submitted to euthanasia 15, 30 and 60 days after experimental procedure, and their femurs were removed to histological evaluation. RESULTS: there was bone growth in all the studied groups, with a greater tendency of growth in the group 1. After 30 days all the groups presented similar results. After 60 days a greater amount of fibroblasts, osteoblasts, osteocytes and osteoclasts in group 3 was observed, with integrated activity of 3 kinds of cells involved in the bone activation-reabsorption-formation. CONCLUSIONS: The castor polymer associated to the silica nanoparticles is biocompatible and allows osteoconduction. The presence of osteoprogenitors cells suggests silica osteoinduction capacity.


OBJETIVO: Avaliar o comportamento biológico do polímero de mamona contendo nanopartículas de sílica como substituto ósseo. MÉTODOS: Vinte e sete rattus norvergicus albinus, Wistar foram submetidos a defeito ósseo preenchido com polímero de mamona. Foram formados três grupos experimentais, com nove ratos cada: (1) Polímero com carbonato de cálcio; (2) Polímero com carbonato de cálcio dopado com 5 por cento de nanopartículas de sílica; (3) Polímero com carbonato de cálcio dopado com 10 por cento de nanopartículas de sílica; três animais de cada grupo foram submetidos à eutanásia 15, 30 e 60 dias após o procedimento experimental e os fêmures removidos e submetidos à avaliação histológica. RESULTADOS: Houve crescimento ósseo em todos os grupos estudados, com maior tendência de crescimento no grupo contendo polímero de mamona acrescido apenas por carbonato de cálcio. Aos 30 dias, todos os grupos apresentaram resultados semelhantes. Aos 60 dias, notou-se maior presença de fibroblastos, osteoblastos, osteócitos e osteoclastos no grupo 3, com persistência da atividade integrada dos três tipos de células envolvidas no processo de ativação-reabsorção-formação óssea. CONCLUSÕES: O polímero de mamona associado com nanopartículas de sílica é biocompatível e permite a osteocondução. A presença de células osteoprogenitoras nos implantes contendo 10 por cento de sílica indica sua capacidade osteoindutora.


Subject(s)
Animals , Male , Rats , Bone Regeneration/drug effects , Bone Substitutes/therapeutic use , Castor Oil/therapeutic use , Nanoparticles/chemistry , Polyurethanes/chemistry , Silicon Dioxide/chemistry , Bone Regeneration/physiology , Castor Oil/chemistry , Materials Testing , Osteoblasts/drug effects , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL