Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Rev. odonto ciênc ; 23(3): 220-224, jul.-set. 2008. graf, tab
Article in English | LILACS, BBO | ID: lil-494939

ABSTRACT

Purpose: Two single-bottle dentin adhesive systems, Single-Bond and Prime and Bond NT, containing ethanol-water or acetone as solvents, respectively, were investigated for their chemical stability regarding solvent loss. Methods: Stability was measured by the adhesive weight changes in accelerated degradation tests under higher room temperature and relative humidity (RH) than normal conditions over 15 days: 25±2ºC / 60±5% RH, 30±2ºC / 65±5% RH, 40±2ºC / 70±5% RH, and 50±2ºC / 75±5% RH. For each temperature the slope and the constant rate for weight loss were recorded to obtain the Arrhenius plot. Water content in Single Bond was determined by K Fisher Titration, and total solvent amount was obtained by subtraction from total weight. Results: The results for Single Bond indicated water content of 5.90±0.08% and alcohol content of 39.14±1.19%. For Prime and Bond NT the acetone percentage was 43.08±1.15%. Weight changes after the accelerated degradation tests revealed that solvent loss in Single-Bond adhesive was lower than in Prime and Bond NT adhesive. Conclusion: The results suggest that chemical stability of adhesives containing ethanolwater is greater than formulations containing acetone.


Objetivo: Dois sistemas adesivos de frasco único, Single-Bond e Prime and Bond NT, contendo etanol-água e acetona como solventes, respectivamente, foram avaliados quanto à sua estabilidade química devido à perda de solvente. Metodologia: A estabilidade foi medida pelas alterações de peso do adesivo em ensaios de degradação acelerada sob condições de temperatura e umidade acima das condições normais ao longo de 15 dias: 25±2ºC / 60±5% RH, 30±2ºC / 65±5% RH, 40±2ºC / 70±5% RH, e 50±2ºC / 75±5% RH. Para cada temperatura, a inclinação e a taxa constante de perda de peso foram registradas para obter o gráfico de Arrhenius. O conteúdo de água no adesivo Single Bond foi determinado por ensaio K Fisher e a quantidade total de solvente foi obtida pela diferença com o peso total. Resultados: Os resultados para Single Bond indicaram conteúdo de 5,90±0,08% de água e 39,14±1,19%de álcool. Para Prime and Bond NT a porcentagem de acetona foi de 43,08±1,15%. As alterações de peso depois dos ensaios de degradação acelerada mostraram que a perda de solvente no adesivo Single-Bond foi menor que no adesivo Prime and Bond NT. Conclusão: Os resultados sugerem que a estabilidade química do adesivo contendo etanolágua é maior que da formulação contendo acetona.


Subject(s)
Dentin-Bonding Agents/pharmacokinetics , Solvents
2.
Pesqui. odontol. bras ; 17(2): 109-112, Apr.-Jun. 2003. tab
Article in English | LILACS | ID: lil-347419

ABSTRACT

The vascular changes in the subcutaneous connective tissue of rats induced by dentin bonding systems (one step) was studied and compared to those induced by saline solution (negative control) and Furacin (positive control), during the exudative phase of the inflammatory process. Twenty mg/kg of Evan's blue were injected intravenously in the vein of the rats' penises; 0.1 ml of each substance tested was inoculated in the subcutaneous tissue. After a 3 hour period the animals were sacrificed and their skins were excised and punched out with a standard steel 2.5 cm in diameter. The specimens were immediately immersed in 8 ml of formamide and taken to a double boiler for 72 hours at 37ºC, to remove the dye. The liquid containing the overflowed dye was filtered, analyzed in the spectrophotometer (620 nm) and classified according to the criteria established by Nagem-Filho, Pereira (1976). After statistical analysis, the irritative potential of the substances was ranked as follows: Furacin (severe) > Single Bond and Bond 1 (moderate - no significant differences between the dentin bonding systems tested) > saline solution (not significant as regards the irritation degree)


Subject(s)
Animals , Rats , Dentin-Bonding Agents/adverse effects , Subcutaneous Tissue/drug effects , Anti-Infective Agents, Local/adverse effects , Anti-Infective Agents, Local/pharmacokinetics , Bisphenol A-Glycidyl Methacrylate/adverse effects , Bisphenol A-Glycidyl Methacrylate/pharmacokinetics , Capillary Permeability/drug effects , Dentin-Bonding Agents/pharmacokinetics , Inflammation/metabolism , Nitrofurazone/adverse effects , Nitrofurazone/pharmacokinetics , Subcutaneous Tissue/blood supply
3.
Rev. bras. odontol ; 58(5): 309-311, set.-out. 2001. graf
Article in Portuguese | LILACS, BBO | ID: lil-302490

ABSTRACT

Este estudo, vi vitro, teve por objetivo de avaliar o efeito de dois dessensibilizadores dentinários: Gluma (Kulzer) e Pain-Free (Parkell) na adesäo de uma resina restauradora e no vedamento dos túbulos dentinários. As amostras foram submetidas ao teste de traçäo e levadas ao MEV. Näo houve diferença significativa entre os três grupos estudados, de onde concluiu-se: 1) näo ocorreu alteraçäo na força de adesäo da resina restauradora; 2) näo interferiram nos processos de adesäo ao substrato dentinário; 3) o Pain-Free mostrou ao MEV melhoria no vedamento dos túbulos dentinários


Subject(s)
Dentin-Bonding Agents/pharmacokinetics , Dentin-Bonding Agents/therapeutic use , Dental Cements/therapeutic use , Dentin Sensitivity , In Vitro Techniques , Dental Cavity Preparation/methods , Tensile Strength , Tooth
4.
Rev. bras. odontol ; 58(4): 275-9, jul.-ago. 2001. ilus
Article in Portuguese | LILACS, BBO | ID: lil-296792

ABSTRACT

O objetivo desse trabalho é relatar um caso clínico, no qual foi utilizado um cimento de ionômero de vidro modificado por resina como suporte para o esmalte socavado, tendo a funçäo de dentina artificial, para posteriormente ser restaurado com amálgama de prata. Devido a esse procedimento, o preparo cavitário realizado foi mais conservador, ao mesmo tempo que se promoveu um esforço das estruturas dentais, as quais se encontravam friáveis


Subject(s)
Humans , Male , Adult , Dentin-Bonding Agents/pharmacokinetics , Dentin-Bonding Agents/therapeutic use , Glass Ionomer Cements/pharmacokinetics , Glass Ionomer Cements/therapeutic use , Composite Resins/pharmacokinetics , Composite Resins/therapeutic use , Dental Enamel/metabolism , Dentin/metabolism , Dental Amalgam , Dental Restoration, Permanent
5.
Säo Paulo; s.n; 1998. 117 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: lil-211205

ABSTRACT

A biocompatibilidade de dois sistemas adesivos, Clearfil Liner Bond 2 (CLB2) e Scotchbond Multipurpose Plus (SBMP) foi avaliada quando os mesmos foram aplicados diretamente sobre polpas humanas e em culturas de células. Foram realizadas cavidades de Classe I e V com exposiçöes pulpares em 20 terceiros molares. Em 4 dentes o capeamento foi realizado com Ca(OH)² e a cavidade foi preenchida com IRM. Metade das polpas restantes foi capeada com SBMP e metade com CLB2, sendo todas as cavidades restauradas com resina composta Z100. Os dentes foram extraídos após 30 e 90 dias, sendo processados para análise histológica (Hematoxilina-Eosina) e detecçäo bacteriana (Brown & Hopps). No estudo in vitro, os mesmos materiais foram previamente aplicados em placas de Petri...


Subject(s)
Dentin-Bonding Agents/analysis , Dentin-Bonding Agents/pharmacokinetics , Biocompatible Materials , Dental Pulp Capping , In Vitro Techniques , Dental Pulp , Dentistry, Operative
6.
Rev. Assoc. Paul. Cir. Dent ; 51(3): 251-5, maio-jun. 1997. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-872211

ABSTRACT

Avaliou-se a resistência de união ao cisalhamento de 11 sistemas adesivos sobre dentina e a união na interface compósito-dente. Condicionou-se a superfície da dentina de 88 dentes e aplicou-se o sistema adesivo selecionado. Depois, foi aplicado e polimerizado o comósito restaurador, submetendo-se os espécimes ao ensaio de resistência ao cisalhamento. Todos os sistemas adesivos apresentaram resistência de união superior estatisticamente ao sistema convencional Heliobond. A resistência de união do All Bond 2, ScotchBond Multi-Purpose e Optibond foi superior estatisticamente a dos demais produtos. Houve falha coesiva nos sistemas OptiBond, ScotchBond Multi-Purpose e All Bond 2 e, nos demais sistemas adesiva


Subject(s)
Dentin-Bonding Agents/analysis , Dentin-Bonding Agents/pharmacokinetics , Dentin-Bonding Agents/chemistry , Dentin/ultrastructure , Dental Materials/analysis