Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Neurol India ; 2002 Mar; 50(1): 17-22
Article in English | IMSEAR | ID: sea-121433

ABSTRACT

Serial roentgenograms of 40 patients who had 70 cervical intervertebral spaces grafted with ethylene oxide sterilized cadaver bone and 28 patients who received 44 iliac crest auto grafts for anterior cervical spine fusion, were studied. The radiological evaluation was made on the basis of settlement of intervertebral spaces, fusion rate, delayed union, non-union, graft collapse and extrusion of the graft. Indigenous methodologies were designed for the assessment of settlement of grafted intervertebral spaces in percentage. Disc space settlement was more common in autografts (93% cases) than in allografts (80% cases). The average percentage of settlement of intervertebral disc space (S%) was 22 in autografts and 28 in allografts during the first four months. By the end of eight months, allograft disc spaces settle more. No significant difference was noted in fusion rate at the end of one year viz. allografts (90% cases) and autografts (93% cases). Autograft and allograft (ethylene oxide sterilized cadaver bone) are equally useful in anterior cervical spine fusions.


Subject(s)
Bone Transplantation , Bone and Bones/drug effects , Disinfectants/pharmacology , Ethylene Oxide/pharmacology , Humans , Myelography , Spinal Fusion , Spine/diagnostic imaging , Transplantation, Autologous
2.
RBCF, Rev. bras. ciênc. farm. (Impr.) ; 37(2): 203-209, maio-ago. 2001. tab, graf
Article in Portuguese | LILACS | ID: lil-314046

ABSTRACT

A esterilização por óxido de etileno consiste no principal método esterilizante aplicado à esterilização de materiais termossensíveis. O óxido de etileno pode ser usado puro ou em misturas com gases inertes, a fim de diminuir suas características de inflamabilidade e explosividade. O presente trabalho objetivou o estudo da influência da concentração gasosa sobre a efetividade esterilizante da mistura de óxido de etileno com HCFCs 22 e 124 (Oxyfume 2002R), sob distintas temperaturas (45, 55 e 65ºC). Procedeu-se a desafios sub-letais (3, 6, 9, 12 e 15 minutos), empregando indicadores biológicos Attest 1264R da 3M, contendo Bacilus subtilus var. niger ATCC 9372. A eficácia esterilizante da mistura...


Subject(s)
Bacillus subtilis , Sterilization/methods , Chemosterilants/pharmacology , Gases , In Vitro Techniques , Ethylene Oxide/analysis , Ethylene Oxide/pharmacology , Analysis of Variance , Indicators and Reagents , Laminar Flow , Spores
3.
Acta bioquím. clín. latinoam ; 32(3): 333-61, sept. 1998. ilus, tab
Article in Spanish | LILACS | ID: lil-235064

ABSTRACT

El óxido de etileno (OE), compuesto de amplio uso en la esterilización de materiales médico-quirúrgicos, es un agente alquilante con actividad mutagénica en distintos sistemas experimentales y probable carcinógeno en humanos. El objetivo de este trabajo es evaluar la sensibilidad de parámetros bioquímicos y citogenéticos en la determinación de daño inducido por OE en 12 técnicos de una central de esterilización con sus correspondientes controles. Los marcadores biológicos incluyeron: hemograma; electroforesis de hemoglobina; separación electroforética de proteínas séricas; determinación de la concentración sérica de bilirrubina: total y directa; determinación de la actividad de aminotransferasas: ALAT y ASAT, lactato deshidrogenasa y fosfatasa alcalina; fraccionamiento electroforético de fosfatasa alcalina. Al mismo tiempo en cultivo de linfocitos de sangre periférica se determinó la frecuencia de aberraciones cromosómicas/célula (AC), la variación del índice mitótico (IM) y la cinética de proliferación celular expresado como índice de replicación (IR). El análisis del fraccionamiento de la fosfatasa alcalina, reveló la presencia de fosfatasa alcalina placentaria en seis de los individuos expuestos. Asimismo, en los estudios de genotoxicidad, se observó un incremento estadísticamente significativo de la frecuencia de AC (p < 0,01) y una disminución tanto del IM (p < 0,0001) como del IR (0,001). Estos datos corroboran los efectos tóxicos del OE y demuestran la importancia de implementar una batería de marcadores biológicos en los estudios de monitoreo humano


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Occupational Exposure/adverse effects , In Vitro Techniques , Biomarkers/blood , Ethylene Oxide/adverse effects , Alkaline Phosphatase/drug effects , Blood/drug effects , Carcinogens/analysis , Chemistry, Clinical , Chromosome Aberrations , Cytogenetics/trends , Sterilization/instrumentation , Mitotic Index , Sister Chromatid Exchange , Biomarkers/analysis , Mutagenicity Tests , Mutagens/adverse effects , Ethylene Oxide/pharmacology , Liver Function Tests
SELECTION OF CITATIONS