Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Gac. méd. Caracas ; 122(1): 29-33, ene.-mar. 2014. ilus, tab
Article in Spanish | LILACS | ID: lil-772735

ABSTRACT

Las estrias angioides de la retina se aprecian como líneas dentelladas rosadas u oscuras radiando irregularmente en todas direcciones desde el área peripapilar hacia la periferia de la retina. Corresponden a roturas del componente elástico de la membrana de Bruch. Su presencia indica una enfermedad sistémica siendo las más importantes el pseudoxantoma elástico, la enfermedad de Paget ósea y la drepanocitosis, Los tumores hipofisiarios raramente se han asociado a está condición existiendo apenas tres descriptores en la literatura. A estas adicionamos tres pacientes más, no obstante, aun no puede asegurarse si se trata de una asociación o de un simple hallazgo incidental.


Retinal angioid streaks can be seen as rough lines pink or dark, irregularly radiating in all directions from the peripapilar area to the periphery of the retina. They correspond of breaks in the elastic component of the Bruch membrane. Its presence indicates a systemic disease being the most important pseudoxanthoma elasticum, bone Paget's disease and sickle cell disease. Pituitary tumors have rarely been associated with this condition and exist just three descriptions in the literature. To these we add three more patients, however, still not be tightened if it's an association or a simple incidental finding.


Subject(s)
Humans , Male , Adult , Middle Aged , Headache/diagnosis , Angioid Streaks/complications , Bruch Membrane/anatomy & histology , Nausea/diagnosis , Osteitis Deformans/etiology , Diplopia/physiopathology , Hemianopsia/physiopathology , Ophthalmology , Visual Acuity
2.
Arq. bras. oftalmol ; 73(5): 409-413, Sept.-Oct. 2010. ilus, graf, tab
Article in English | LILACS | ID: lil-570500

ABSTRACT

PURPOSE: To correlate visual field sensitivity (VFS) loss on standard automated perimetry (SAP) and quadrantic macular thickness on optical coherence tomography (OCT) in patients with permanent temporal hemianopia from chiasmal compression. METHODS: Forty eyes from 40 patients with chiasmal compression and 40 healthy eyes were submitted to standard automated perimetry and Stratus-OCT scanning. Raw data of the fast macular thickness scanning protocol were exported and macular thickness measurements were recorded and averaged for each quadrant and half of the central area. The correlation between visual field sensitivity loss and optical coherence tomography measurements was tested with Pearson's correlation coefficients and with linear regression analysis. RESULTS: A significant association was found between each macular thickness parameter and the corresponding central VF mean sensitivity. The strongest association was observed between superonasal macular thickness and the inferotemporal mean defect measured both in decibel (R=0.47; p=0.001) and in 1/Lambert (R=0.59; p<0.0001) units. CONCLUSION: Stratus-OCT-measured macular thickness was topographically related with visual field sensitivity loss in patients with temporal hemianopia from chiasmal compression. Such measurements could prove clinically useful in the diagnosis and follow-up of patients with chiasmal compression. ClinicalTrial.gov identifier number: NCT0039122.


OBJETIVO: Avaliar a correlação entre o defeito de campo visual ao exame de perimetria computadorizada e a espessura macular quadrântica ao exame de tomografia de coerência óptica (OCT) em pacientes com hemianopsia temporal permanente causada por compressão quiasmática. MÉTODOS: Quarenta olhos de 40 pacientes com compressão quiasmática e 40 olhos de 40 indivíduos controles foram submetidos aos exames de perimetria computadorizada e tomografia de coerência óptica. Dados não processados foram exportados e as medidas de espessura macular foram calculadas para cada quadrante e metade da área macular central. A correlação entre o defeito campimétrico e as medidas de espessura macular foi avaliada por coeficiente de correlação de Pearson e por análise de regressão linear. RESULTADOS: Associação significante foi encontrada entre os parâmetros de espessura macular e seus respectivos defeitos campimétricos. A correlação mais forte foi encontrada entre o parâmetro espessura macular nasal superior e o defeito campimétrico médio temporal inferior medido em decibel (R=0,47; p=0,001) e em 1/Lambert (R=0,59; p<0,0001). CONCLUSÃO: Medidas de espessura macular avaliada através da tomografia de coerência óptica foi topograficamente relacionada ao defeito campimétrico em pacientes com hemianopsia temporal por compressão quiasmática. Estas medidas podem provar a importância clínica no diagnóstico e seguimento dos pacientes com compressão quiasmática. ClinicalTrial.gov identifier number: NCT0039122.


Subject(s)
Adult , Female , Humans , Male , Hemianopsia/physiopathology , Macula Lutea/pathology , Nerve Compression Syndromes/complications , Optic Chiasm/pathology , Visual Fields/physiology , Epidemiologic Methods , Hemianopsia/etiology , Hemianopsia/pathology , Tomography, Optical Coherence
SELECTION OF CITATIONS
SEARCH DETAIL