Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. Asoc. Argent. Ortop. Traumatol ; 85(4): 403-417, dic. 2020.
Article in Spanish | LILACS, BINACIS | ID: biblio-1351416

ABSTRACT

El tratamiento de la osteomielitis asociada a la falla de la osteosíntesis representa un verdadero desafío para el cirujano ortopédico. El retiro del implante, la limpieza quirúrgica del área afectada y la fijación externa como métodos de estabilidad transitoria, sumados a la administración de antibióticos por vía sistémica son conductas habituales en el manejo inicial de la infección asociada a la falla del implante. No obstante, la suma de estas medidas puede no ser suficiente para controlar completamente el cuadro. El agregado local de cemento con antibiótico permite la liberación continua y sostenida del agente que alcanza una concentración local significativamente más alta que las concentraciones inhibitorias bacterianas mínimas necesarias, a expensas de una menor toxicidad sistémica. Se presentan dos casos de osteomielitis asociada a la falla de la osteosíntesis tratados mediante una nueva síntesis con placa revestida de cemento con antibiótico. Se logró controlar la infección y la consolidación ósea en ambos casos. El resultado funcional fue excelente con un puntaje QuickDASH de 6,3 y 4,5, respectivamente. Nivel de Evidencia: IV


Treatment of osteomyelitis associated with osteosynthesis failure represents a real challenge for the orthopedic surgeon. Implant removal, surgical debridement of the affected area, and external fixation as a temporary stabilization method coupled with antibiotic therapy administered by the systemic route constitute the basis for the initial management of infections associated with implant failure. However, this combined management may prove inadequate to achieve complete control of the infection. The local use of antibiotic-loaded cement allows for maintaining a sustained agent release that reaches significantly higher concentrations than the minimum required bacterial inhibitory concentrations while reducing the associated systemic toxicity. We present two cases of osteomyelitis associated with osteosynthesis failure treated with a second osteosynthesis procedure with an antibiotic cement-coated plate. Infection control and bone union were achieved in both cases. The functional outcome was excellent with Quick-DASH scores of 6.3 and 4.5 points, respectively. Level of Evidence: IV


Subject(s)
Middle Aged , Osteomyelitis , Bone Cements , Internal Fixators/adverse effects , Anti-Bacterial Agents
2.
Rev. Asoc. Argent. Ortop. Traumatol ; 84(2): 105-111, jun. 2019.
Article in Spanish | LILACS, BINACIS | ID: biblio-1003018

ABSTRACT

Objetivo: Evaluar si la colocación de los dispositivos interespinosos siliconados tipo DIAM favorecen una tasa más alta de recidiva de la hernia discal homolateral clínica y por imágenes comparada con la discectomía pura. Materiales y Métodos: Se realizó un estudio prospectivo, observacional, aleatorizado desde mayo de 2009 hasta mayo de 2013, en nuestro Centro. Se evaluó a 123 pacientes, 3 se perdieron en el seguimiento; la muestra incluyó 120 sujetos. Todos fueron operados por el mismo equipo quirúrgico. Se formaron dos grupos: grupo A: discectomía más colocación de dispositivo interespinoso siliconado, 30 pacientes (16 mujeres y 14 hombres), con mayor frecuencia L4-L5 (27 pacientes, 90%) y grupo B: discectomías puras, 90 pacientes (53 mujeres y 37 hombres) con más frecuencia L4 y L5 (72 pacientes, 80%). Resultados: Seis de los pacientes del grupo A (20%) tuvieron una recidiva clínica y por imágenes, y 3 (10%) fueron operados nuevamente; en el grupo B, hubo 4 recidivas discales (4,4%), uno fue operado nuevamente (1,1%). Se hallaron diferencias significativas en las tasas de recidiva y reintervención entre los grupos (p = 0,0073 y p = 0,0188, respectivamente). Conclusiones: Los beneficios de los dispositivos interespinosos para tratar el canal estrecho lumbar secundario a hernia de disco son controvertidos, pero en nuestro estudio, se halló una diferencia significativa según el grupo. Al mantener el movimiento del segmento y cambiar ligeramente las cargas fisiológicas aumentarían la tasa de recidiva discal; no obstante, son necesarios estudios con mayor evidencia científica para corroborar estas tendencias. Nivel de Evidencia: III


Objective: The objective of this study was to determine if discectomy with placement of an interspinous DIAM silicon spacer is associated with a different rate of clinical and radiological recurrent ipsilateral disc herniation compared to discectomy alone. Methods: A prospective, observational, randomized study was performed from May 2009 to May 2013 at our center. Of the 123 patients included in the study, 3 were lost to follow-up, leaving 120 patients for data analysis. All patients were operated on by the same surgical team. Patients received one of two types of treatment. Group A consisted of 30 patients (16 women and 14 ment) who underwent discectomy with placement of an interspinous DIAM silicone spacer. Group B was comprised of 90 patients (53 women and 37 men) treated by discectomy alone. Results: Discectomy at L4-L5 level was the most common approach, being performed in 90% (27) of Group A patients and 80% (72) of Group B patients. Group A demonstrated clinical and radiological recurrent disc herniation in 6/30 (20%) patients. Recurrent disc herniation developed in 4/90 (4.4%) of Group B patients. One patient underwent surgical revision (1.1%). Both recurrence and surgical revision were significantly higher in Group A (p = 0.007 and p = 0.019, respectively). Conclusions: The benefits of interspinous devices for the treatment of the lumbar spinal stenosis secondary to disc herniation are controversial, and this study showed a significant intergroup difference. In this study, patients that underwent discectomy and interspinous spacer placement had higher revision and recurrence rates than discectomy patients that did not receive an interspinous spacer. Interspinous spacers may increase the rate of disc herniation by preserving movement at the level of the original disc herniation and changing the physiologic load. Further studies are needed to corroborate and evaluate these trends. Level of Evidence: III


Subject(s)
Adult , Middle Aged , Recurrence , Internal Fixators/adverse effects , Diskectomy , Intervertebral Disc Displacement/complications , Lumbar Vertebrae/surgery , Follow-Up Studies , Treatment Failure
3.
Acta ortop. bras ; 13(3): 134-136, 2005. ilus
Article in Portuguese | LILACS | ID: lil-410760

ABSTRACT

Estudamos os resultados clínicos e radiográficos de 31 pacientes portadores de fraturas diafisárias do úmero que foram operados com hastes intramedulares. Destes quatro apresentaram fraturas no local da inserção da haste e foram tratados com outro método. Dos 27 pacientes restantes o índice de consolidação foi de 96,1 por cento e que durou em média de 63,4 dias. Cinco queixaram-se de dor no ombro e em apenas um apresentou limitação da abdução. Paralisia temporária do nervo radial foi constatada em dois pacientes e pseudartrose em um que após 5 meses da cirurgia foi submetido a nova intervenção cirúrgica com o emprego de placa e enxerto ósseo autólogo. Concluímos que embora o emprego de hastes intramedulares bloqueadas apresentou alto índice de a via de acesso retrógrada pode levar a fraturas no seu ponto de entrada e via anterógrada com violação do manguito rotador pode gerar dores no ombro.


Subject(s)
Male , Female , Humans , Humeral Fractures/surgery , Humeral Fractures/complications , Humeral Fractures/rehabilitation , Internal Fixators , Rotator Cuff , Internal Fixators/adverse effects , Shoulder Pain
4.
Acta ortop. bras ; 8(4): 192-201, out.-dez. 2000. tab, graf
Article in Portuguese | LILACS | ID: lil-283812

ABSTRACT

Os autores desenvolveram um novo implante para osteotomia proximal de tíbia como alternativa para tratamento da osteoartrose do joelho com deformidade em varo. O objetivo do trabalho foi desenvolver uma placa para fixaçäo simples, de fácil manejo, e menor custo, propiciando baixa morbidade em relaçäo aos métodos existentes, e compará-la com o método idealizado por BRUNNER e WEBER (1982)² que utilizaram a placa semitubular. Os testes mecânicos foram realizados em máquina universal de ensaios do Laboratório de Bioengenharia da Faculdade de Medicina de Ribeiräo Preto, Campus Universitário, Universidade de Säo Paulo. Nos parâmetros analisados como limite de proporcionalidade, módulo de elasticidade observaram-se valores diferentes entre as duas placas mostrando que o novo implante apresentou resistência e estabilidade superior à placa semitubular quando submetidos a testes de flexäo.


Subject(s)
Humans , Internal Fixators/adverse effects , Knee/surgery , Osteotomy , Osteoarthritis
5.
Cir. & cir ; 62(6): 205-9, nov.-dic. 1994. tab, ilus
Article in Spanish | LILACS | ID: lil-143100

ABSTRACT

Se presentan 722 casos de no unión ósea (en tibia 344, en fémur 292 y en húmero 86) tratados por medio del clavo Colchero intramedular con pernos. En 382 pacientes el padecimiento fue aséptico y en 340 infectados por lo cual hubo que retirar la sepsis por el método de escarificación, para convertir la falta de unión en aséptica y dejarla preparada para la osteosíntesis. En las no uniones atróficas se utilizó hueso esponjoso autólogo y en las hipertróficas no hubo que recurrir a este procedimiento. La unión se logró con una cirugía en 720 casos, existiendo 2 no uniones que se volvieron a operar por el mismo método y se resolvieron. La marcha con apoyo total se inició a los tres días de la cirugía; con ello, la consolidación fue rápida, el enfermo pudo volver al trabajo pronto y a una vida social activa


Subject(s)
Adolescent , Adult , Middle Aged , Humans , Male , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/rehabilitation , Femoral Fractures/surgery , Femoral Fractures/complications , Fractures, Ununited/complications , Fractures, Ununited/rehabilitation , Surgical Wound Infection/rehabilitation , Internal Fixators/adverse effects , Tibial Fractures/complications , Tibial Fractures/surgery
SELECTION OF CITATIONS