Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Rev. bras. cir. cardiovasc ; 26(4): 597-603, out.-dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-614752

ABSTRACT

OBJETIVOS: Analisar a correlação entre a SvO2 (indicador do débito cardíaco) e a SjO2 (indicador da oxigenação cerebral) durante cirurgias cardíacas com circulação extracorpórea (CEC) em crianças. MÉTODOS: Estudo retrospectivo. Dados da SjO2, SvO2 e SaO2, mensurados simultaneamente em momentos críticos da cirurgia cardíaca com CEC, em 12 crianças, foram analisados pelo teste de correlação de Spearman e pela representação gráfica de Bland-Altman. RESULTADOS: Foram encontrados baixa correlação entre a SjO2 e a SvO2 (r²=0,14, P=0,03) e um viés alto (-7,8) na plotagem de Bland-Altman, indicando independência entre as duas variáveis. SjO2 < 50 por cento (indicativo de isquemia-hipoxia cerebral) foi observada em cerca de 50 por cento das medidas após o reaquecimento no final da CEC hipotérmica. CONCLUSÕES: A medida de SvO2 não é preditiva da SjO2 durante a cirurgia cardíaca com CEC em crianças e baixa SjO2 pode deixar de ser detectada medindo-se apenas a SvO2.


OBJECTIVES: To compare the SjO2 (cerebral oxygenation indicator) and SvO2 (cardiac output indicator) during pediatric cardiac surgery with cardiopulmonary bypass (CPB). METHODS: Retrospective study. Data of SjO2 and SvO2 measured simultaneously at critical time periods during cardiac surgery with CPB were analyzed by the Spearman correlation test and Bland- Altman plot. RESULTS:Regression analysis of the pooled data showed poor correlation between SjO2 and SvO2 (r²=0.14, P=0.03) and Bland- Altman plot had a high bias (-7.9), indicating independency of the two variables. SjO2<50 percent (indicative of cerebral ischemia-hypoxia) were observed in 50 percent of the measurements after rewarming during hypothermic CPB. CONCLUSIONS: SvO2 is not a good predictor of SjO2 during pediatric cardiac surgery with CPB, and low SjO2 can be undetected measuring SvO2 only.


Subject(s)
Child, Preschool , Humans , Infant , Brain/metabolism , Cardiac Output/physiology , Cardiopulmonary Bypass/methods , Cerebrovascular Circulation/physiology , Jugular Veins/physiology , Oxygen Consumption/physiology , Blood Glucose/metabolism , Epidemiologic Methods , Heart Defects, Congenital/surgery
2.
Arq. neuropsiquiatr ; 68(4): 567-572, Aug. 2010. tab
Article in English | LILACS | ID: lil-555236

ABSTRACT

OBJECTIVE: To observe the repercussion of respiratory physiotherapy techniques on the mean arterial pressure (MBP), intracranial pressure (ICP), cerebral perfusion pressure (CPP), jugular venous oxygen pressure (PjvO2) and jugular venous oxygen saturation (SjvO2). METHOD: The sample consisted of 20 patients with head trauma. The protocol consisted of physiotherapy techniques application of vibrocompression (VBC), expiratory flow increase (EFI) and suction. RESULTS: The results show the maintenance on variables of cerebral hemodynamics during the techniques of VBC and EFI. However, in relation to suction, there was an increase of MBP, ICP, with maintenance of CPP, PjvO2 and SjvO2 and return to baseline of MBP and ICP 10 minutes after the end of suction. CONCLUSION: The respiratory physiotherapy techniques (VBC, EFI) do not promote cerebral hemodynamic repercussion, unlike suction, in severe head injury patients, mechanically ventilated, sedated and paralyzed.


OBJETIVO: Observar a repercussão das técnicas de fisioterapia respiratória na pressão arterial média (PAM), pressão intracraniana (PIC), pressão de perfusão cerebral (PPC), pressão venosa jugular de oxigênio (PjO2) e saturação venosa jugular de oxigênio (SjO2). MÉTODO: Foram incluídos no estudo 20 pacientes com traumatismo cranioencefálico. O protocolo consistiu na aplicação das manobras fisioterapêuticas de vibrocompressão (VBC), aumento de fluxo expiratório (AFE) e aspiração (ASP). RESULTADOS: Os resultados mostraram a manutenção das variáveis da hemodinâmica cerebral durante as manobras de VBC e AFE. Porém, em relação à ASP, houve uma elevação da PAM e PIC, com manutenção da PPC, PjO2 e SjO2 e retorno aos valores basais da PAM e PIC dez minutos após o final da aspiração. CONCLUSÃO: As manobras de fisioterapia respiratória (VBC, AFE) não promovem alterações sobre a hemodinâmica cerebral, ao contrário da ASP traqueal, em pacientes com traumatismo cranioencefálico grave, em ventilação mecânica, sedados e curarizados.


Subject(s)
Adult , Female , Humans , Male , Blood Pressure/physiology , Brain/blood supply , Craniocerebral Trauma/therapy , Intracranial Pressure/physiology , Jugular Veins/physiology , Oxygen/blood , Respiratory Therapy/methods , Craniocerebral Trauma/physiopathology , Prospective Studies , Valsalva Maneuver
3.
Rev. bras. cir. cardiovasc ; 23(4): 488-493, out.-dez. 2008. graf, tab
Article in English, Portuguese | LILACS | ID: lil-506031

ABSTRACT

OBJETIVO: É comum a obtenção de acesso venoso femoral em pacientes submetidos a cirurgia cardíaca em associação ou como alternativa ao acesso superior (veia jugular interna ou veia subclávia). O objetivo deste estudo foi comparar as medidas de pressão venosa central (PVC) em dois sítios diferentes (superior vs. femoral). MÉTODOS: Estudo prospectivo e aberto com 60 pacientes submetidos a cirurgia cardíaca no período de julho a novembro de 2006. Foram obtidas três medidas de cada paciente em cada sítio (admissão, 6 e 12 horas após a cirurgia) em duas inclinações diferentes da cabeceira do leito (zero e 30 graus), totalizando 720 medidas. RESULTADOS: Cinqüenta e cinco por cento dos pacientes foram submetidos a revascularização do miocárdio, 38 por cento a cirurgia valvar e 7 por cento a outras cirurgias. A média de PVC ± desvio padrão (DP) medida no acesso superior foi de 13,0 ± 5,5 mmHg (zero grau) e 13,3 ± 6,1 mmHg (30 graus), enquanto que as medidas no acesso inferior foram 11,1 ± 4,9 mmHg (zero grau) e 13,7 ± 4,6 mmHg (30 graus). A correlação linear (r) entre as medidas nos dois sítios foi de 0,66 (zero grau) e 0,53 (30 graus), ambas com p < 0,0001. CONCLUSÃO: A PVC pode ser medida com acurácia no acesso venoso femoral no pós-operatório imediato de cirurgia cardíaca, com melhor correlação linear obtida com as medidas feitas com a cabeceira do leito posicionada em zero grau.


OBJECTIVE: It is common to obtain femoral venous approach in patients undergoing combined heart surgery or as an alternative to superior approach (internal jugular vein or subclavian vein). The aim of this study was to compare the measures of central venous pressure (CVP) at two different sites (superior versus femoral). METHODS: We prospectively and openly allocated 60 patients who underwent heart surgery between July from November 2006. Three measures were obtained from each patient at each site (admission, 6 and 12 hours after surgery) in two different inclinations of the headboard (zero and 30 degrees) totaling 720 measures. RESULTS: Fifty five percent of patients who underwent coronary artery bypass grafting, 38 percent heart valve surgery and 7 percent other surgeries. The mean of CVP ± standard deviation (SD) measured in superior approach was 13.0 ± 5.5 mmHg (zero degree) and 13.3 ± 6.1 mmHg (30 degrees) while the measures in inferior approach were 11.1 ± 4.9 mmHg (zero degree) and 13.7 ± 4.6 mmHg (30 degrees). The linear correlation (r) between the measures in both sites was 0.66 (zero degree) and 0.53 (30 degrees), both with p value<0.0001. CONCLUSION: The CVP can be measured with accuracy in the femoral venous approach in the immediate postoperative period of heart surgery with better linear correlation obtained with the measures made with the headboard positioned at zero degree.


Subject(s)
Female , Humans , Male , Middle Aged , Cardiac Surgical Procedures , Catheterization, Central Venous/methods , Central Venous Pressure/physiology , Femoral Vein/physiology , Jugular Veins/physiology , Subclavian Vein/physiology , Beds , Epidemiologic Methods , Postoperative Period , Posture , Preoperative Care , Time Factors
4.
Biol. Res ; 41(2): 227-233, 2008. tab, graf
Article in English | LILACS | ID: lil-495757

ABSTRACT

Background: The characterization of the dynamic process of veins walls is essential to understand venous functioning under normal and pathological conditions. However, little work has been done on dynamic venous properties. Aim: To characterize vein compliance (C), viscosity (η), peak-strain (W St) and dissipated (W D) energy, damping (ξ), and their regional differences in order to evalúate their role in venous functioning during volume-pressure overloads. Methods: In a mock circulation, pressure (P) and diameter (D) of different veins (anterior cava, jugular and femoral; from 7 sheep), were registered during cyclical volume-pressure pulses. From the P-D relationship, C, W St and ξ (at low and high P-D leveis), η and W D were calculated. Resulls: For each vein there were P-dependent differences in biomechanical, energetics, and damping capability. There were regional-differences in C, η), W St and W D (p<0.05), but not in ξ. Conclusión: The regional-dependent differences in dynamics and energetics, and regional-similitude in damping could be important to ensure venous functioning during acute overloads. The lower C and higher W St and W D found in back-limb veins (femoral), commonly submitted to high volume-pressure loads (i.e. during walking), could be considered relevant to ensure adequate venous system functionality and venous wall protection simultaneously.


Subject(s)
Animals , Blood Pressure/physiology , Blood Volume/physiology , Femoral Vein/physiology , Jugular Veins/physiology , Vena Cava, Inferior/physiology , Biomechanical Phenomena , Compliance , Femoral Vein/anatomy & histology , Jugular Veins/anatomy & histology , Sheep , Viscosity , Vena Cava, Inferior/anatomy & histology
6.
Acta cir. bras ; 14(1): 35-42, mar. 1999. ilus, tab
Article in Portuguese | LILACS | ID: lil-233805

ABSTRACT

Os principais objetivos dos desvios veno-venosos durante o transplante ortotópico de fígado são: atenuação da estase venosa subdiafragmática, manutenção do retorno satisfatório de sangue ao coração e perfusão tissular eficiente. Investigações sobre PP, PVCIIH, PVC, PAM e PPR, bem como DPP e DPVCIIH foram conduzidas em seis cães, sob anestesia geral, com fígados perfundidos pela Artéria Hepática, submetidos a desvios porta-jugular e cava-jugular passivos durante 2 horas. Estes desvios não foram capazes de evitar estagnação de sangue na VP e VCIIH, acarretando estase e menor retorno sangüíneo ao coração, sugeridos por aumentos significativos de PP e PVCIIH e quedas significantes nos níveis de PVC. Os valores de PAM não apresentaram diferenças significativas em relação ao tempo T0, na maior parte dos tempos avaliados, enquanto que os valores de PPR foram significativamente menores que os verificados no tempo T0, na maioria dos tempos estudados. Tais pressões mantiveram-se, respectivamente, acima de 100 e 50 mm de Hg, atribuindo-se tais resultados, em parte, à vasoconstricção arteriolar generalizada. Incrementos de pressão na VP (DPP) foram significativamente menos elevados que aqueles verificados na VCIIH (DPVCIIH), atribuindo-se tal diferença à complacência esplâncnica. Decréscimos ulteriores dos níveis de PP e PVCIIH sugerem queda do fluxo arterial para os territórios esplâncnico e sistêmico, decorrente de diminuição do retorno sangüíneo ao coração. Determinações de PP, PVCIIH, PVC, PAM e PPR podem constituir meio prático de avaliação hemodinâmica do desvio veno-venoso.


Subject(s)
Animals , Dogs , Male , Female , Arteriovenous Shunt, Surgical , Jugular Veins/physiology , Portal Vein/physiology , Liver Transplantation/physiology , Vena Cava, Inferior/physiology , Arterial Pressure
9.
Bulletin of Alexandria Faculty of Medicine. 1992; 28 (1): 45-53
in English | IMEMR | ID: emr-120797

ABSTRACT

Distensibility study was done on isolated segments of the saphenous, the cephalic, and the jugular veins. All veins were found to be normally, in a state of tension and to retract [recoil] after being cut. The recoil varies in the different veins. The saphenous vein possessed the narrowest lumen and the thickest wall, while the jugular vein showed the reverse situation, and the cephalic vein stands midway between both. At pressures below 100 mmHg, the highest distensibility was encountered in the jugular vein, while the least was in the saphenous vein, but at pressures above 100 mmHg, the reverse was true. Also, the cephalic vein stands midway between both veins


Subject(s)
Humans , Male , Jugular Veins/physiology
11.
Ars cvrandi cardiol ; 8(65): 40-1,43,46,passim, out. 1986. ilus
Article in Portuguese | LILACS | ID: lil-35984
SELECTION OF CITATIONS
SEARCH DETAIL