Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
China Journal of Orthopaedics and Traumatology ; (12): 7-14, 2024.
Article in Chinese | WPRIM | ID: wpr-1009216

ABSTRACT

OBJECTIVE@#To investigate the clinical effect of unilateral percutaneous vertebroplasty (PVP) combined with 3D printing technology for the treatment of thoracolumbar osteoporotic compression fracture.@*METHODS@#A total of 77 patients with thoracolumbar osteoporotic compression fractures from October 2020 to April 2022 were included in the study, all of which were vertebral body compression fractures caused by trauma. According to different treatment methods, they were divided into experimental group and control group. Thirty-two patients used 3D printing technology to improve unilateral transpedicle puncture vertebroplasty in the experimental group, there were 5 males and 27 females, aged from 63 to 91 years old with an average of (77.59±8.75) years old. Forty-five patients were treated with traditional bilateral pedicle puncture vertebroplasty, including 7 males and 38 females, aged from 60 to 88 years old with an average of(74.89±7.37) years old. Operation time, intraoperative C-arm X-ray times, anesthetic dosage, bone cement injection amount, bone cement diffusion good and good rate, complications, vertebral height, kyphotic angle (Cobb angle), visual analogue scale(VAS), Oswestry disability index (ODI) and other indicators were recorded before and after surgery, and statistically analyzed.@*RESULTS@#All patients were followed up for 6 to 23 months, with preoperative imaging studies, confirmed for thoracolumbar osteoporosis compression fractures, two groups of patients with postoperative complications, no special two groups of patients' age, gender, body mass index (BMI), time were injured, the injured vertebral distribution had no statistical difference(P>0.05), comparable data. Two groups of patients with bone cement injection, bone cement dispersion rate, preoperative and postoperative vertebral body height, protruding after spine angle(Cobb angle), VAS, ODI had no statistical difference(P>0.05). The operative time, intraoperative fluoroscopy times and anesthetic dosage were statistically different between the two groups(P<0.05). Compared with the traditional bilateral puncture group, the modified unilateral puncture group combined with 3D printing technology had shorter operation time, fewer intraoperative fluoroscopy times and less anesthetic dosage. The height of anterior vertebral edge, kyphosis angle (Cobb angle), VAS score and ODI of the affected vertebrae were statistically different between two groups at each time point after surgery(P<0.05).@*CONCLUSION@#In the treatment of thoracolumbar osteoporotic compression fractures, 3D printing technology is used to improve unilateral puncture PVP, which is convenient and simple, less trauma, short operation time, fewer fluoroscopy times, satisfactory distribution of bone cement, vertebral height recovery and kyphotic Angle correction, and good functional improvement.


Subject(s)
Male , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Fractures, Compression/surgery , Spinal Fractures/surgery , Bone Cements , Treatment Outcome , Vertebroplasty/methods , Kyphosis/surgery , Punctures , Printing, Three-Dimensional , Technology , Osteoporotic Fractures/surgery , Anesthetics , Retrospective Studies , Kyphoplasty/methods
2.
China Journal of Orthopaedics and Traumatology ; (12): 445-449, 2023.
Article in Chinese | WPRIM | ID: wpr-981713

ABSTRACT

OBJECTIVE@#To verify the safety of three dimensional printing percutaneous guide plate assisted percutaneous kyphoplasty(PKP) in the treatment of osteoporotic vertebral compression fractures(OVCFs).@*METHODS@#The clinical data of 60 patients with OVCFs treated by PKP from November 2020 to August 2021 were retrospectively analyzed. There were 24 males and 36 females, aged from 72 to 86 years old with an average of (76.5±7.9) years. Routine percutaneous kyphoplasty was performed in 30 cases (conventional group) and three dimensional printing percutaneous guide plate assisted PKP was performed in 30 cases (guide plate group). Intraoperative pedicle puncture time (puncture needle to posterior vertebral body edge) and number of fluoroscopy, total operation time, total number of fluoroscopy, amount of bone cement injection, and complication (spinal canal leakage of bone cement) were observed. The visual analogue scale (VAS) and the anterior edge compression rate of the injured vertebra were compared before operation and 3 days after operation between two groups.@*RESULTS@#All 60 patients were successfully operated without complication of spinal canal leakage of bone cement. In the guide plate group, the pedicle puncture time was(10.23±3.15) min and the number of fluoroscopy was(4.77±1.07) times, the total operation time was (33.83±4.21) min, the total number of fluoroscopy was(12.27±2.61) times;and in the conventional group, the pedicle puncture time was (22.83±3.09) min and the number of fluoroscopy was (10.93±1.62) times, the total operation time was(44.33±3.57) min, the total number of fluoroscopy was(19.20±2.67) times. There were statistically significant differences in the pedicle puncture time, intraoperative number of fluoroscopy, the total operation time, and the total number of fluoroscopy between the two groups(P<0.05). There was no significant difference in amount of bone cement injection between the two groups(P>0.05). There were no significant differences in VAS and the anterior edge compression rate of the injured vertebra at 3 days after operation between two groups(P>0.05).@*CONCLUSION@#Three dimensional printing percutaneous guide plate assisted percutaneous kyphoplasty is safe and reliable, which can reduce the number of fluoroscopy, shorten the operation time, and decrease the radiation exposure of patients and medical staff, and conforms to the concept of precise orthopaedic management.


Subject(s)
Male , Female , Humans , Aged , Aged, 80 and over , Kyphoplasty/methods , Fractures, Compression/surgery , Spinal Fractures/surgery , Bone Cements , Retrospective Studies , Treatment Outcome , Osteoporotic Fractures/surgery
3.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 452-456, 2023.
Article in Chinese | WPRIM | ID: wpr-981614

ABSTRACT

OBJECTIVE@#To analyze the correlation between bone cement cortical leakage and injury degree of osteoporotic vertebral compression fracture (OVCF) after percutaneous kyphoplasty (PKP), and to provide guidance for reducing clinical complications.@*METHODS@#A clinical data of 125 patients with OVCF who received PKP between November 2019 and December 2021 and met the selection criteria was selected and analyzed. There were 20 males and 105 females. The median age was 72 years (range, 55-96 years). There were 108 single-segment fractures, 16 two-segment fractures, and 1 three-segment fracture. The disease duration ranged from 1 to 20 days (mean, 7.2 days). The amount of bone cement injected during operation was 2.5-8.0 mL, with an average of 6.04 mL. Based on the preoperative CT images, the standard S/H ratio of the injured vertebra was measured (S: the standard maximum rectangular area of the cross-section of the injured vertebral body, H: the standard minimum height of the sagittal position of the injured vertebral body). Based on postoperative X-ray films and CT images, the occurrence of bone cement leakage after operation and the cortical rupture at the cortical leakage site before operation were recorded. The correlation between the standard S/H ratio of the injured vertebra and the number of cortical leakage was analyzed.@*RESULTS@#Vascular leakage occurred in 67 patients at 123 sites of injured vertebrae, and cortical leakage in 97 patients at 299 sites. Preoperative CT image analysis showed that there were 287 sites (95.99%, 287/299) of cortical leakage had cortical rupture before operation. Thirteen patients were excluded because of vertebral compression of adjacent vertebrae. The standard S/H ratio of 112 injured vertebrae was 1.12-3.17 (mean, 1.67), of which 87 cases (268 sites) had cortical leakage. The Spearman correlation analysis showed a positive correlation between the number of cortical leakage of injured vertebra and the standard S/H ratio of injured vertebra ( r=0.493, P<0.001).@*CONCLUSION@#The incidence of cortical leakage of bone cement after PKP in OVCF patients is high, and cortical rupture is the basis of cortical leakage. The more severe the vertebral injury, the greater the probability of cortical leakage.


Subject(s)
Male , Female , Humans , Aged , Kyphoplasty/methods , Bone Cements , Fractures, Compression/surgery , Spinal Fractures/surgery , Retrospective Studies , Osteoporotic Fractures/etiology , Treatment Outcome , Vertebroplasty/methods
4.
China Journal of Orthopaedics and Traumatology ; (12): 429-434, 2022.
Article in Chinese | WPRIM | ID: wpr-928336

ABSTRACT

OBJECTIVE@#To compare the efficacy between vesselplasty and percutanous kyphoplasty (PKP) in the treatment of Kümmell disease.@*METHODS@#The clinical data of patients with Kümmell disease from July 2018 to December 2019 were retrospectively analyzed. According to the different therapeutic methods, the patients were divided into vesselplasty group and PKP group. There were 20 patients in vesselplasty group, including 2 males and 18 females, aged from 54 to 83 years with an average of (67.40±7.44)years, 1 case of T10 fracture, 3 cases of T12 fracture, 9 cases of L1 fractures, 5 cases of L2 fractures and 2 cases of L3 fractures. There were 20 patients in PKP group, including 3 males and 17 females, aged from 56 to 81 with an average of(67.20±7.01) years, 2 cases of T10 fracture, 1 case of T11 fracture, 6 cases of T12 fracture, 10 cases of L1 fracture and 1 case of L3 fracture. Visual analogue scale(VAS), Cobb angle, anterior vertebral height were recorded before operation, 1 day after operation and 1 year after operation. Oswestry Disability Index(ODI) was recorded before operation, 1 month after operation and 1 year after operation. And bone cement leakage rate was compared between two groups after operation.@*RESULTS@#All the patient were followed up for more than 1 year. In vesselplasty group, VAS score was 1.20±0.41, ODI was(13.50±3.10)%, Cobb angle was(17.20±3.12)° and anterior vertebral height was(20.20±1.35) mm at 1 year after operation. In PKP group, VAS score was 1.15±0.40, ODI was (13.20±3.00)%, Cobb angle was (17.10±3.19)° and anterior vertebral height was (20.10±1.37) mm at 1 year after operation. These index was significantly better than pre-operation through intra-group comparison(P<0.05), and there was no statistically difference between the two groups(P>0.05). There were 20 cases (20 vertebrae) in vesselplasty group, of which 1 case had bone cement leakage at the upper endplate, with a leakage rate of 5%(1/20). In PKP group, there were 20 cases (20 vertebrae), 3 cases of upward endplate leakage(3/7), 1 case of downward endplate leakage(1/7), 1 case of leakage to the front of the vertebral body(1/7), 2 cases of leakage to the side of the vertebral body(2/7), with a leakage rate of 35% (7/20). The difference between two groups was statistically significant(P<0.05).@*CONCLUSION@#Vesselplasty in the treatment of Kümmell disease can better reduce leakage rate of bone cement and reduce complications.


Subject(s)
Female , Humans , Male , Bone Cements , Fractures, Compression/surgery , Kyphoplasty/methods , Osteoporotic Fractures/surgery , Retrospective Studies , Spinal Fractures/surgery , Spondylosis , Treatment Outcome , Vertebroplasty
5.
Rev. chil. radiol ; 19(4): 150-155, 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-701724

ABSTRACT

Pathological vertebral fractures are caused by various entities. They cause significant pain and impaired quality of life of patients. The CT-guided kyphoplasty relieves or eliminates pain and stabilizes the fractured vertebral bodies. 49 patients were treated. The procedure is performed percutaneously by inserting a needle that is subsequently removed, leaving a cannula. Through this a balloon-like device is introduced and subsequently inflated to create a cavity, which is then filled with polymethylmethacrylate (PMMA). The technique was performed successfully in all cases without serious complications, with good results. Its advantages are that the needle placement as well as the injection of PMMA can be correctly visualized using real-time CT fluoroscopy. In addition a single needle is used throughout the entire procedure, which minimizes the risk of complications as it is less traumatic.


Las fracturas vertebrales patológicas se originan por diversas entidades. Producen dolor importante y deterioro de la calidad de vida de los pacientes. La cifoplastia guiada por tomografía computarizada (TC) alivia o elimina el dolor y estabiliza los cuerpos vertebrales fracturados. Se han tratado 49 pacientes. El procedimiento se realiza por vía percutánea, mediante la inserción de una aguja que posteriormente se retira dejando una cánula. A través de la misma se introduce un dispositivo que lleva incorporado un balón que se infla creando una cavidad, que se rellena con polimetilmetacrilato (PMMA). La técnica se practicó con éxito en todos los casos sin complicaciones graves, con buenos resultados. Sus ventajas son visualizar correctamente la posición de la aguja y la inyección del PMMA mediante la escopia del TC en tiempo real. Además se utiliza una sola aguja para todo el procedimiento, lo cual minimiza el riesgo de complicaciones siendo menos traumático.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Tomography, X-Ray Computed/methods , Spinal Fractures/therapy , Spinal Fractures/diagnostic imaging , Polymethyl Methacrylate/administration & dosage , Kyphoplasty/methods , Radiography, Interventional , Spinal Fractures/etiology
SELECTION OF CITATIONS
SEARCH DETAIL