Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Korean Journal of Ophthalmology ; : 271-276, 2012.
Article in English | WPRIM | ID: wpr-194322

ABSTRACT

PURPOSE: To evaluate the effect of axial length on the variability of retinal nerve fiber layer (RNFL) thickness measurements using the Stratus optical coherence tomography (OCT) in normal and glaucomatous eyes. METHODS: We measured the RNFL thickness in 474 subjects using the Stratus OCT twice during the same day. Axial length was measured with the IOLMaster, and refractive error was the absolute value of the spherical equivalent measured with an auto ref-keratometer. Standard deviation in overall mean RNFL thickness was used as the dependent variable to identify significant correlations. RESULTS: Long axial length affected the variability in the RNFL thickness value by stratus OCT at the temporal quadrant (p = 0.006) and clock-hour sector 9 (p = 0.001). Refractive error also affected the variability of the RNFL thickness value by stratus OCT at the temporal quadrant (p = 0.025) and clock-hour sector 9 (p = 0.024). CONCLUSIONS: It is clinically significant that longer axial length demonstrates greater variability in temporal area as detected by OCT, a measurement which correlates with the preferably damaged position in the myopic glaucoma eye.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Glaucoma/pathology , Myopia, Degenerative/pathology , Nerve Fibers/pathology , Prospective Studies , Refractive Errors , Retinal Ganglion Cells/pathology , Tomography, Optical Coherence/methods
2.
Arq. bras. oftalmol ; 69(2): 203-206, mar.-abr. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-426717

ABSTRACT

OBJETIVO: Avaliar a presença de alterações fundoscópicas em pacientes portadores de miopia degenerativa. MÉTODOS: Quarenta pacientes com erro refrativo de pelo menos -6,00 dioptrias foram selecionados para exame oftalmológico, complementado por retinografia do pólo posterior e ecobiometria. RESULTADOS: Foram estudados 57 olhos de 37 pacientes com erro refrativo de -6,25 a -28,50 dioptrias, com média de -14,05, e comprimento axial de 26,06 a 32,86 mm, com média de 28,01. Encontramos crescente temporal em 36,5 por cento e circunferencial em 21 por cento dos olhos. Vasos da coróide foram visualizados em 35 por cento dos olhos. As alterações do pólo posterior foram as seguintes: estafiloma posterior em 10,5 por cento, mancha de Fuchs em 3,5 por cento e "lacquer cracks" em 1,5 por cento. O exame da periferia retiniana evidenciou atrofia corio-retiniana tipo pavimentosa em 17,5 por cento, branco sem pressão em 10,5 por cento, degeneração "lattice" em 5 por cento, ruptura retiniana em 3,5 por cento e retinosquise em 1,5 por cento dos olhos examinados. CONCLUSÕES: Alterações fundoscópicas que levam à baixa visual são freqüentes em pacientes com miopia degenerativa. O exame da periferia retiniana é muito importante nestes pacientes devido ao risco aumentado de descolamento de retina.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Fundus Oculi , Myopia, Degenerative/pathology , Myopia, Degenerative/complications , Retina , Retinal Degeneration/etiology , Retinal Detachment/etiology
3.
Rev. oftalmol. venez ; 61(3): 147-152, jul.-sept. 2005. ilus, tab
Article in Spanish | LILACS | ID: lil-517145

ABSTRACT

Evaluar si la remoción de la membrana limitante interna (MLI) en la cirugía de agujero macular idiopático mejora los resultados anatómicos y funcionales de la cirugía. Estudio comparativo retrospectivo, no randomizado, sobre 10 ojos de 10 pacientes con agujero macular estadio III y IV de Gass, operados todos ellos con la misma técnica. En 5 ojos se realizó remoción de la MLI (grupo A) y en los otros 5 sin remoción de la MLI (grupo B). Se evalua la recuperación anatómica y funcional, y las complicaciones de la cirugía en ambos grupos. De los 10 ojos operados se consigue la recuperación anatómica (cierre del agujero) en el 80 por ciento (8 ojos). En el grupo A la recuperación anatómica fue del 100 por ciento los casos, y del 60 por ciento en el grupo B (p=0,016). De todos los ojos operados mejoraron la agudeza visual en una o más líneas de Snellen, 6 ojos (60 por ciento). Se observó mejoría de la agudeza visual en 3 de los 5 ojos del grupo A (60 por ciento), y en el 3 de los 5 ojos del grupo B (60 por ciento). Las complicaciones más importantes fueron el desprendimiento de retina en dos casos del grupo A y un caso del grupo B, la catarata y los cambios a nivel del epitelio pigmentario de retina. En nuestra experiencia la remoción de la MLI en la cirugía del agujero macular mejora los resultados anatómicos, pero no la agudeza visual final. Otros estudios que incluyan un mayor número de pacientes son necesarios para comparar esta técnica de tratamiento con las técnicas convencionales en cuanto a la mejoría de agudeza visual final.


Subject(s)
Humans , Male , Female , Aged , Visual Acuity/physiology , Cataract/physiopathology , Myopia, Degenerative/pathology , Retinal Perforations/surgery , Retinal Perforations/pathology , Retinal Perforations/therapy , Macular Degeneration/surgery
SELECTION OF CITATIONS
SEARCH DETAIL