Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. bras. cardiol. invasiva ; 20(4): 413-419, out.-dez. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-666142

ABSTRACT

INTRODUÇÃO: Baseados na hipótese de que a neoíntima encontrada em stents farmacológicos (SFs) com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva e de que a tomografia de coerência óptica (TCO) é um método eficaz para a avaliação sequencial da neoíntima, objetivamos, neste estudo experimental, comparar os achados da TCO aos 28 dias e aos 90 dias em dois tipos de SF com polímeros biodegradáveis: o stent liberador de sirolimus (Inspiron®, Scitech) e o stent liberador de biolimus A9 (Biomatrix®, Biosensors International). MÉTODOS: No total, 6 porcos não-ateroscleróticos foram submetidos a implante de 6 stents Inspiron® e de 6 stents Biomatrix®. Cada porco recebeu os dois tipos de stent, um em cada artéria coronária (descendente anterior e circunflexa) e após 28 dias e 90 dias foram realizadas avaliações qualitativas intrastent a cada milímetro com TCO. RESULTADOS: A avaliação qualitativa, feita por pareamento milímetro a milímetro intrastent, evidenciou neoíntima heterogênea em 39% aos 28 dias e em 0% aos 90 dias, presença de tecido intraluminal em 18% aos 28 dias e em 0% aos 90 dias, irregularidade luminal em 62% aos 28 dias e em 2% aos 90 dias (P < 0,005). Não houve diferença entre os grupos quanto à qualidade da neoíntima ao longo do tempo (P > 0,05). CONCLUSÕES: Os achados à TCO corroboram a hipótese de que a neoíntima encontrada em SFs com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva. A evidência experimental mais significativa é a mudança das características da neoíntima observada à TCO sequencial.


BACKGROUND: Based on the hypothesis that the neointima found in drug-eluting stents (DES) with biodegradable polymers at 28 days is not a definitive neointima and that optical coherence tomography (OCT) is an effective method for sequential neointimal evaluation, we aim, in this experimental study, to compare OCT findings at 28 and 90 days, in two different DES with biodegradable polymers: the sirolimus-eluting stent (Inspiron®, Scitech) and the biolimus A9-eluting stent (Biomatrix®, Biosensors International). METHODS: Overall, 6 non-atherosclerotic pigs were submitted to the implantation of 6 Inspiron® stents and 6 Biomatrix® stents. Each pig received both stent types, one in each coronary artery (left anterior descending artery and circumflex artery) and after 28 and 90 days qualitative in-stent OCT analyses were performed at 1-millimeter intervals. RESULTS: Qualitative assessment was performed in-stent pairing millimeter by millimeter. Heterogeneous neointimal tissue was evidenced in 39% at 28 days and in 0% at 90 days, the presence of intraluminal tissue in 18% at 28 days and in 0% at 90 days, luminal irregularity in 62% at 28 days and in 2% at 90 days (P < 0.005). There was no difference between groups regarding the quality of the neointima over time (P > 0.05). CONCLUSIONS: The OCT findings corroborate the hypothesis that the neointima found in DES with biodegradable polymers at 28 days is not a definitive neointima. The most significant experimental evidence is the change in the neointimal characteristics observed at sequential OCT.


Subject(s)
Animals , Angioplasty/methods , Angioplasty , Neointima/complications , Polymers , Drug-Eluting Stents , Tomography, Optical Coherence/methods , Tomography, Optical Coherence
SELECTION OF CITATIONS
SEARCH DETAIL