1.
Clinics ; 74: e781, 2019. tab, graf
Article in English | LILACS | ID: biblio-989636

ABSTRACT

OBJECTIVES: The halo ring can be applied in children, through skeletal traction or a halo vest device, to treat many cervical spine pathologies, including traumatic injuries and pathologies related to deformities. However, the procedure is associated with various complications, such as infection, pin loosening, and respiratory and neurological problems. Although widely studied in adults, the best pin insertion site in children and the correlations of pin insertion sites with outcomes and complications have not been completely elucidated. This study aimed to determine alternative pin placement sites based on a morphological analysis of the infant skull by computerized tomography (CT). METHODS: An analytical-descriptive study was performed using 50 CT scans from children. The Wilcoxon and Friedman tests were used. RESULTS: A linear and directly proportional relation was found between cranial thickness and patient age. The average thicknesses of the anterior points across all ages analyzed ranged from 4.16 mm to 4.98 mm. The thicknesses of the posterior points varied from 3.94 mm to 4.27 mm. Within each age range, points 1 cm above the standard insertion sites had thicknesses similar to those of the standard sites, and points 2 cm above the standard insertion sites had thicknesses greater than those of the standard sites. CONCLUSIONS: The cranial thickness at all points increases linearly with age. Points 1 and 2 cm above the standard insertion sites are viable alternatives for the placement of halo pins. Preoperative CT can aid in choosing the best positioning sites for pins in the skull.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Orthotic Devices/standards , Skull/diagnostic imaging , Bone Nails/standards , Tomography, X-Ray Computed/methods , Skull/anatomy & histology , Preoperative Care/methods , Cervical Vertebrae/injuries , Age Factors , Imaging, Three-Dimensional/methods
2.
Rev. bras. med. trab ; 16(4): 524-531, dez-2018.
Article in English, Portuguese | LILACS | ID: biblio-980493

ABSTRACT

Introdução: Lombalgia é um problema internacional importante de saúde pública. O uso de cinta lombar no meio ocupacional emerge da expectativa de inúmeros benefícios biomecânicos que, em conjunto, promoveriam a prevenção desse problema. Objetivo: Orientar estudantes, médicos e estabelecimentos de saúde sobre o uso de cinta lombar, suporte ou órtese lombar como prevenção da lombalgia ou de lesões lombares em trabalhadores sem sintomatologia atual. Método: Ela foi desenvolvida a partir da revisão sistemática da literatura: da base de dados MEDLINE, foram recuperados 809 trabalhos e das bases EMBASE e Central Cochrane, 571. Avaliar a cinta lombar como intervenção preventiva de lombalgia envolve a quantificação de benefícios, malefícios e facilidade de sua implementação, assim como a qualidade metodológica dos estudos primários. Conclusão: Apesar do benefício demonstrado fracamente em resultados individuais, parciais e isolados em poucos estudos, não há evidência consistente que sustente a utilização de cinta lombar, suporte ou órtese lombar na prevenção primária da lombalgia ou de lesões lombares ocupacionais em trabalhadores. As evidências, agrupadas, apontam para ausência de redução de absenteísmo com o uso da cinta lombar.


Background: Low back pain is a considerable global public health problem. Use of back belts in occupational settings arises from the expectation of countless biomechanical benefits, which together would contribute to the prevention of this problem. Objective: To orient students, physicians and health institutions on the use of back belts, lumbar support or braces for prevention of low back pain or injury among asymptomatic workers. Method: The present guideline was developed based on a systematic literature review; 809 studies were located in database MEDLINE and 571 in EMBASE and Cochrane CENTRAL. Evaluating back-belt use as preventive intervention against low back pain demands quantifying benefits, harms and difficulties to implementation, as well as the methodological quality of primary studies. Conclusion: Despite the weak benefits reflected in the individual, partial and isolated results of a few studies, there is no consistent evidence for the use of back belts, lumbar supports or braces for primary prevention of low back pain or occupational low back injury among workers. According to the available evidence, back-belt use is not associated with reduction of absenteeism


Subject(s)
Orthotic Devices/standards , Low Back Pain/prevention & control , Occupational Diseases , Absenteeism , Health Facilities/standards
3.
Rev. bras. enferm ; 71(3): 1099-1105, May-June 2018. graf
Article in English | LILACS, BDENF | ID: biblio-958640

ABSTRACT

ABSTRACT Objective: to assess potential failures in the care process with orthotics, prosthetics and special materials in a high-complexity hospital. Method: an intervention study conducted from March to October 2013. This process was assessed with the Failure Mode and Effects Analysis (FMEA) service tool. The data were analysed according to the risk and the corrective measures were defined. Results: no failure was classified as high risk and the corrective measures indicated as low and moderate risk had the following improvement initiatives suggested: standardize the material records in the information system; create a specific form to require materials; hire specialized technical personnel and create a continuous education program. Conclusion: all the suggested initiatives were implemented and helped to reduce the assistance risks for patients due to failures in this process. The actions increase safety levels and provide higher quality of service.


RESUMEN Objetivo: evaluar las fallas potenciales en el proceso de trabajo del cuidado con ortesis, prótesis y materiales especiales en un hospital de alta complejidad. Método: estudio de intervención realizado de marzo a octubre de 2013. El proceso fue evaluado utilizando la herramienta de Análisis del Modo y Efecto de Fallas del tipo servicio. Los datos fueron analizados conforme el riesgo y se definieron las medidas correctivas. Resultados: ninguna falla fue clasificada como alto riesgo y las medidas correctivas apuntadas como de bajo y moderado riesgo han tenido propuestas de acciones de perfeccionamiento: estandarización de los registros de materiales en el sistema de información; creación de un formulario específico para la solicitud de material; contratación de personal técnico especializado y creación de un programa de educación permanente. Conclusión: todas las acciones propuestas fueron implantadas y ayudaron en la reducción del riesgo asistencial a los pacientes por fallas en este proceso, aumentando los niveles de seguridad y proporcionando más calidad en el servicio.


RESUMO Objetivo: avaliar as falhas potenciais, no processo de trabalho do cuidado com órteses, próteses e materiais especiais em um hospital de alta complexidade. Método: estudo de intervenção realizado de março a outubro de 2013. O processo foi avaliado utilizando a ferramenta de Análise de Modos de Falhas e Efeitos do tipo serviço. Os dados foram analisados conforme o risco e foram definidas as medidas corretivas. Resultados: nenhuma falha foi classificada de alto risco e as medidas corretivas apontadas como de baixo e moderado risco tiveram propostas de ações de melhoria, como: padronização dos cadastros de materiais no sistema de informação; criação de um formulário específico para a solicitação de material; contratação de pessoal técnico especializado e criação de um programa de educação permanente. Conclusão: todas as ações propostas foram implantadas e auxiliaram na redução do risco assistencial aos pacientes por falhas neste processo, aumentando os níveis de segurança e proporcionando maior qualidade no serviço.


Subject(s)
Humans , Orthotic Devices/standards , Prostheses and Implants/standards , Risk Assessment/methods , Nursing Care/standards , Brazil , Medical Errors/prevention & control , National Health Programs/organization & administration
4.
Acta fisiátrica ; 24(3): 154-159, set. 2017.
Article in English, Portuguese | LILACS | ID: biblio-968429

ABSTRACT

Subluxação do ombro é a complicação musculoesquelética mais comum das afecções do Sistema Nervoso Central e Periférico, que leva a diminuição do movimento, da função e aumento de dor. Órtese é um dos recursos auxiliares utilizados no tratamento desta patologia e visa corrigir deformidade, diminuir dor e proporcionar função ao membro acometido. Objetivo: Este trabalho propõe uma nova metodologia para projetar e fabricar órteses customizadas estabilizadoras de ombro utilizando as tecnologias de aquisição 3D por escaneamento e de fabricação por Impressão 3D, e assegurar melhor adaptabilidade e maior conforto para o usuário. Método: A metodologia utilizada neste estudo foi dividida em cinco fases: estudo de caso, escaneamento, modelagem e impressão em 3D; e acabamento. O estudo de caso do usuário com lesão de plexo braquial motivou o projeto de desenho original de órtese híbrida, personalizada e manufaturada em 3D, usando estrutura rígida e faixas de tração, com objetivo de estabilizar o ombro, diminuir a dor e permitir função. Resultados: Após escaneamento em 3D utilizou-se softwares especializados para processar a imagem tridimensional STL. Realizaram-se otimizações do projeto com geração de modelos e peças prototipadas em FDM; avaliada pelo usuário. O conceito desenvolvido foi: órtese personalizada, fácil de higienizar e vestir, resistente, articulada, veste nos dois braços com faixas de tração em tecido rígido acoplado à cintura. Conclusão: O teste com usuário corroborou com o conceito projetado e mostrou um protótipo preliminar com bom acoplamento ao tronco, tração satisfatória e possibilidade de realizar um maior número de AVD´s com menos dor e/ou sensação de cansaço


Subluxation of the shoulder is the most common musculoskeletal complication of Central and Peripheral Nervous System disorders, which leads to decreased movement, function, and increased pain. Objective: Orthosis is one of the assistive devices used in the treatment of this pathology and it focuses in correcting deformity, decreasing pain and providing function to the affected member. This study proposes a new methodology for designing and manufacturing customized shoulder stabilization orthoses with 3D scan image acquisition and 3D printing technologies, for ensuring better adaptability and comfort for the user. Method: The methodology used in this study was divided into five phases: case study, scanning, modeling and 3D printing; and finishing. The case study included a user with brachial plexus injury that motivated the original design of hybrid orthosis, personalized and manufactured in 3D, with rigid structure and traction straps, for stabilizing the shoulder, reduce pain and allowing function. Results: After 3D scanning, we used specialized software to process the three-dimensional STL image. Optimization of the project with generation of models and prototyped parts in FDM based on the user evaluations was performed. The developed concept was: personalized orthosis, easy to clean and wear, resistant, articulated, for wearing in both arms with traction straps in rigid fabric coupled to the waist. Conclusion: The user test corroborated with the designed concept and showed a preliminary prototype with good trunk coupling, satisfactory traction and possibility of performing a greater number of ADLs with less pain and/or tiredness


Subject(s)
Humans , Orthotic Devices/standards , Shoulder/physiopathology , Technological Development , Printing, Three-Dimensional/standards , Upper Extremity/physiopathology
5.
Bauru; s.n; 2017. 86 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-880013

ABSTRACT

A expansão de maxila cirurgicamente assistida (EMCA) é a modalidade de tratamento que tem como objetivo romper as regiões de reforço maxilar permitindo seu movimento expansivo gradativamente. Tal movimento pode ser realizado às custas de aparelhos dento-suportado, dento-muco-suportado, implanto-suportados ou ósseo-suportado. Os efeitos produzidos pelo tratamento vão desde alterações esqueléticas (aumento da base, cavidade e do espaço aéreo nasais) até inclinações dentárias (principalmente nos dentes de suporte do aparelho expansor), dentre outras. O objetivo desta pesquisa foi avaliar, por meio do Método de Elementos Finitos (MEF), a distribuição das tensões produzidas pela EMCA nas estruturas maxilares utilizando-se aparelho expansor ósseo-suportado. Material e métodos: Foi confeccionado um modelo tridimensional de maxila para simulação da EMCA com osteotomia tipo LeFort I descendente sem degrau, com disjunção pterigomaxilar utilizando um modelo de aparelho ósseo-suportado para o teste com a simulação de abertura de 1mm. Os resultados mostraram maior abertura da maxila na região anterior de incisivos a pré-molar (1 mm) e em menor quantidade (0,6mm) na região de molares. A tensão máxima principal (TMXP) mostrou a concentração de tensões principalmente em toda face palatina da maxila de pré-molar ao túber maxilar. Pela face lateral, ficou mais evidente a TMXP nas região de osso alveolar posterior ao pré-molar, molares e túber, assim como na região de pilar zigomático acima da osteotomia. Pelo plano transversal foi possível observar a transmissão de tensões ao longo das estruturas ósseas mostrando pouca dissipação para as raízes do molar. Enquanto que as forças de compressão (Tensão Mínima Principal), evidenciadas pela tensão mínima principal, se manifestaram nas áreas de pilar zigomático e adjacentes as osteotomias, assim como na áreas de contato do apoio do aparelho com o osso palatino. Tensões de tração e compressão também foram evidenciadas na região de processo pterigoide. A análise de tensão de Von Mises mostrou que a parte que mais sofre estresse é a haste que liga o módulo do aparelho com a plataforma de apoio. Conclusão: Houve maior abertura da maxila na região anterior e as tensões resultantes de forças transmitidas ao osso alveolar dos dentes adjacentes ao aparelho, parecem não ser suficientes para deslocar os dentes.(AU)


Surgically assisted maxillary expansion (SARME) is the modality of treatment that aims to weaken the points of maxillary reinforcement allowing its gradual expansion. Such movement can be performed at the expense of dento-supported, dento-muco-supported, implanto-supported or bony-backed devices. The effects produced by the treatment range from skeletal changes (increase of nasal base, cavity and nasal air space) to dental inclinations (mainly in the supporting teeth of the expander apparatus), among others. The objective of the present research was to evaluate the distribution of stress produced by SARME in the maxillary structures using the bone-supported expander apparatus by the Finite Element Method (FEM). Material and methods: A three-dimensional hemi-maxilla model was simulated for SARME with a non-step descending LeFort I osteotomy with pterygomaxillary disjunction using a bone-supported device model for the 1mm aperture simulation test. The results showed a greater opening of the maxilla in the anterior region of the incisors to the premolar (1 mm) and smaller (0.6 mm) in the molar region. The principal maximal stress (TMXP) showed the concentration of the tension forces mainly in all the palatine face of the pre-molar maxilla to the maxillary tuft. Due to the lateral aspect, the TMXP was more evident in the posterior alveolar bone region, the molars and tuber, as well as in the epilating zygomatic region above the osteotomy. From the transversal plane, it was possible to observe the transmission of stress along the bony structures showing little dissipation for the roots of the molar. Meanwhile, the forces of compression (Principal Minimum Tension) evidenced by the principal minimal stress, were manifested in the areas of the zygomatic pillar adjacent to the osteotomies, as well as in the areas of contact of the support of the apparatus with the palatine bone. Tension and compression forces were also evidenced in the pterygoid process region. Von Mises' stress analysis showed that the most stressed part is the rod connecting the device module to the support platform. Conclusion: There was a greater opening of the maxilla in the anterior region and the resulting forces of tension transmitted to the alveolar bone of the teeth adjacent to the appliance did not seem to be sufficient to displace the teeth.(AU)


Subject(s)
Humans , Finite Element Analysis , Maxilla/physiopathology , Maxilla/surgery , Orthotic Devices/standards , Osteotomy, Le Fort/methods , Palatal Expansion Technique/instrumentation , Equipment Design , Reference Standards , Reference Values , Reproducibility of Results
8.
Brasília; CONITEC; 2015.
Non-conventional in Portuguese | LILACS, BRISA | ID: biblio-874951

ABSTRACT

INTRODUÇÃO: Tendo em vista a estrutura do Sistema Nacional de Vigilância Sanitária (SNVS), em que as ações de inspeção sanitária são descentralizadas, a fim de assegurar resultados consistentes nas atividades de inspeção em indústrias fabricantes de produtos de interesse à saúde, é fundamental que haja uniformidade nas ações desenvolvidas pela autoridade sanitária brasileira, independentemente do ente do SNVS executor da ação. Neste sentido, buscando a harmonização das práticas de inspeção sanitária, a Portaria n° 511, de 14 de Abril de 2010, instituiu um Grupo de Trabalho Tripartite, com representantes da Agência Nacional de Vigilância Sanitária (Anvisa) e dos órgãos estaduais e municipais de vigilância sanitária, cujo objeto de trabalho constituía-se na elaboração de procedimentos e demais documentos necessários ao processo de inspeção sanitária na indústria de medicamentos. O referido grupo de trabalho pactuou entre as três esferas, não só procedimentos operacionais, relacionados ao processo de inspeção sanitária, mas também documentos basilares, necessários à implementação de um Sistema de Gestão da Qualidade (SGQ), como Manual da Qualidade, procedimentos operacionais (POP) para controle de documentos, para treinamentos internos, dentre outros. A fim de dar continuidade ao trabalho do GT Tripartite, cuja duração era de 90 dias, foi instituído o GT de Gestão de Documentos, conforme Portaria nº 999 de 22 de Junho de 2012. Com caráter permanente, este último tem como responsabilidade a revisão e manutenção dos procedimentos já estabelecidos relacionados ao Sistema da Qualidade e às atividades de inspeção sanitária. Adicionalmente, tendo em vista a necessidade de ampliar o escopo de atividades coberto pelos procedimentos operacionais harmonizados, dois outros Grupos de Trabalho específicos foram instituídos. Um deles, publicado por meio da Portaria nº. 1001, de 22 de junho de 2012, responsável pelo desenvolvimento de procedimentos relacionados a distribuidoras e armazenadoras de medicamentos, bem como indústrias de insumos farmacêuticos; e o segundo, instituído por meio da Portaria 1002, de 22 de junho de 2012, responsável pelo desenvolvimento de procedimentos relacionados a inspeções em indústrias de produtos para saúde. As portarias nº. 1001 e nº. 1002 estabeleceram, respectivamente, prazos de 90 e 120 dias para conclusão dos trabalhos pelos GTs. Tendo em vista a identificação de novos temas para harmonização, um novo GT de Produtos para Saúde foi posteriormente instituído por meio da publicação da Portaria nº. 1232, de 25 de Julho de 2014, que estabeleceu prazo de um ano para conclusão dos trabalhos. Com o intuito de formalizar a adoção dos documentos padronizados pelos órgãos de vigilância sanitária que constituem as esferas federal, estadual e municipal do Sistema Nacional de Vigilância Sanitária (SNVS), foi publicada a Resolução RDC nº 47 de 19 de Setembro de 2011, posteriormente substituída pela Resolução RDC nº 34, de 8 de julho de 2013. foi implementado em 2014 um programa de Auditorias Técnicas do SNVS que tem como objetivo o melhoramento contínuo das atividades dos diferentes órgãos de vigilância sanitária estaduais, distrital e municipais no que se refere aos seus SGQ e aos seus sistemas de inspeção de empresas fabricantes de medicamentos, insumos farmacêuticos e produtos para saúde. Tendo em vista a complexidade do SNVS, e que a execução da inspeção que faz parte do escopo das Auditorias Técnicas muitas vezes está a cargo do município, as informações coletadas durante as Auditorias realizadas pela Anvisa, representam apenas uma pequena amostra sobre a realidade da implementação do SGQ nos órgãos que executam ações de inspeção sanitária em indústrias de medicamentos, insumos farmacêuticos e produtos para saúde. PROCEDIMENTOS: Desta forma, a inclusão dos procedimentos propostos no Sistema de Informação Ambulatorial (SIA/SUS), tem por finalidade servir como fonte de dados que poderão ser utilizados tanto pelos gestores em nível estadual quanto pela Anvisa, enquanto coordenadora do SNVS, com o objetivo de verificar o nível de implementação do SGQ nos órgãos que executam atividades de inspeção nas industrias de produtos de interesse à saúde. Primeiramente, propõe-se uma complementação nos procedimentos já existentes de forma a assegurar o levantamento das informações relativas aos estabelecimentos cadastrados e às inspeções realizadas nos estabelecimentos que são objeto de interesse no atual contexto. RECOMENDAÇÃO DA CONITEC: Os membros da CONITEC presentes na 34ª reunião do plenário, realizada nos dias 1 e 2/4/2015, recomendaram, por unanimidade, a incorporação dos seguintes procedimentos de Vigilância Sanitária na Tabela de Procedimentos, Medicamentos, Órteses, Próteses e Materiais Especiais do SUS: -Cadastro de indústrias de insumos farmacêuticos; -Cadastro de indústrias de produtos para saúde; -Inspeção sanitária de indústrias de insumos farmacêuticos; -Inspeção sanitária de indústrias de produtos para saúde; -Implementação de procedimentos harmonizados em nível tripartite relacionados à inspeção em estabelecimentos fabricantes de medicamentos; -Implementação de procedimentos harmonizados em nível tripartite relacionados a insumos farmacêuticos; -Implementação de procedimentos harmonizados em nível tripartite relacionados a produtos para saúde; -Envio de relatórios de inspeção de estabelecimentos fabricantes de medicamentos à ANVISA; -Envio de relatórios de inspeção de estabelecimentos fabricantes de insumos farmacêuticos à ANVISA; -Envio de relatórios de inspeção de estabelecimentos fabricantes de produtos para a saúde à ANVISA; Auditorias internas realizadas no departamento responsável pelas atividades de inspeção de estabelecimentos fabricantes de medicamentos; -Auditorias internas realizadas no departamento responsável pelas atividades de inspeção de estabelecimentos fabricantes de insumos farmacêuticos; -Auditorias internas realizadas no departamento responsável pelas atividades de inspeção de estabelecimentos fabricantes de produtos para saúde. DECISÃO: PORTARIA Nº 44, 16 de setembro de 2015 - Torna pública a decisão de incorporar no âmbito do Sistema Único de Saúde - SUS procedimentos de Vigilância Sanitária na Tabela de Procedimentos, Medicamentos, Órteses, Prótese e Materiais Especiais do SUS.


Subject(s)
Orthotic Devices/standards , Prostheses and Implants/standards , Health Surveillance/standards , Pharmaceutical Preparations/standards , Health Surveillance Services , Quality Control , Unified Health System , Brazil , Cost-Benefit Analysis
9.
Rev. Clín. Ortod. Dent. Press ; 13(3): 48-60, jun.-jul. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-855992

ABSTRACT

A inclinação do plano frontal da maxila, quando presente na má oclusão, é, para a maioria dos pacientes, a queixa mais comum, pois causa um impacto negativo na estética facial, e a principal referência estética do paciente é, sem dúvida, seu sorriso. / Objetivo / O presente artigo relata um caso clínico de uma paciente adulta jovem, com má oclusão de Classe II, com acentuada inclinação do plano frontal da maxila. / Métodos / O caso foi, inicialmente, tratado com aparelho de Herbst e finalizado com aparelho fixo e elásticos de Classe II, segundo o protocolo da técnica Straight-Wire Simplificada (SSW). / Conclusão / Essa opção clínica se mostrou uma excelente alternativa para a correção da Classe II com plano oclusal inclinado.


Subject(s)
Humans , Female , Young Adult , Orthodontic Appliances/standards , Facial Asymmetry/therapy , Malocclusion, Angle Class II/therapy , Orthotic Devices/standards , Mandibular Advancement/methods , Gingivoplasty/methods
10.
Clinics ; 62(1): 63-68, Feb. 2007. ilus, tab
Article in English | LILACS | ID: lil-441827

ABSTRACT

INTRODUCTION: The floor reaction ankle-foot orthosis is commonly prescribed in the attempt to decrease knee flexion during the stance phase in the cerebral palsy (CP) gait. Reported information about this type of orthosis is insufficient. PURPOSE: The purpose of this study was to determine the effect of clinically prescribed floor reaction ankle-foot orthosis on kinematic parameters of the hip, knee and ankle in the stance phase of the gait cycle, compared to barefoot walking on children with cerebral palsy. METHODS: A retrospective chart review of 2200 patients revealed that 71 patients (142 limbs) had a diagnosis of diplegia, with no contractures in hip, knee or ankle flexion. Their average age was 12.2 ± 3.9. All of them were wearing clinically prescribed hinged floor reaction ankle-foot orthosis undergoing a three dimensional gait analysis. We divided the patients in three groups: Group I, with limited extension (maximum knee extension less than 15°); Group II, with moderate limited extension (maximum knee extension between 15° and 30°) and Group III Crouch (maximum knee extension in stance more than 30°). RESULTS: Results indicate the parameters maximum knee extension and ankle dorsiflexion were significant in Group II e III; no change was observed in Group I. The maximum hip extension was not significant in all three groups. Conclusion: when indicated to improve the extension of the knees and ankle in the stance of the CP patients floor reaction ankle-foot orthosis was effective.


INTRODUÇÃO: A órtese de reação ao solo é freqüentemente prescrita com o objetivo de reduzir a flexão do joelho durante a fase de apoio na marcha de pacientes com paralisia cerebral. Não há informações suficientes relatadas na literature sobre este tipo de órteses. OBJETIVOS: O objetivo deste estudo foi determinar o efeito que a órtese de reação ao solo tem na cinamática angular das articulações do quadril, joelho e tornozelo durante a fase de apoio da marcha de crianças com paralisia cerebral, comparando a marcha descalça e com o uso das órteses MÉTODOS: Após um estudo retrospectivo de 2200 pacientes avaliados no laboratório de marcha, 71 pacientes com diagnóstico de paralisia cerebral do tipo diparesia espástica e idade média de 12.2 ± 3.9 foram selecionados (142 membros). Nenhum deles apresentou contratura em flexão dos quadris, joelhos e tornozelos. Todos usavam órteses do tipo reação ao solo articulada durante a avaliação da marcha. Os pacientes foram divididos em três grupos: Grupo I Extensão Limitada (pico de extensão do joelho menor que 15°); Grupo II Extenão Moderadamente Limitada (pico de extensão do joelho entre 15° e 30°) e Grupo III Agachamento (pico de extensão do joelho no apoio maior que 30°). RESULTADOS: Os resultados demostraram que o pico de extensão do joelho e o pico de dorsiflexão tiveram alterações significantes nos grupos II e III enquanto que o grupo I não apresentou alteração. O pico de extensão do quadril não mostrou alteração nos três grupos CONCLUSÃO: A órtese de reação ao solo é eficaz quando indicada para aumentar a extensão do joelho e tornozelo durante a fase de apoio da marcha de crianças com paralisia cerebral.


Subject(s)
Humans , Child , Adolescent , Ankle Joint/physiopathology , Cerebral Palsy/physiopathology , Gait/physiology , Orthotic Devices/standards , Range of Motion, Articular/physiology , Biomechanical Phenomena , Hip Joint/physiopathology , Knee Joint/physiopathology , Retrospective Studies
11.
Arq. neuropsiquiatr ; 64(1): 20-23, mar. 2006. tab
Article in English | LILACS | ID: lil-425265

ABSTRACT

CONTEXTO: A hemiparesia altera a qualidade de vida de pacientes com acidente vascular encefálico (AVE) dificultando uma vida normal. OBJETIVO: Avaliar o efeito da Órtese Elétrica Funcional (OEF) colocada na perna parética, sobre a qualidade de vida de pacientes com AVE. MÉTODO: A qualidade de vida de 50 pacientes da AACD foi avaliada pelo questionário SF-36 antes e após o tratamento com OEF. Os dados foram analisados segundo sexo e lado do corpo acometido pelo AVE. RESULTADOS: As médias em todas as categorias do SF-36 foram significantemente maiores após tratamento com OEF (p<0,001). Pacientes do sexo feminino apresentaram resultados superiores aos do sexo masculino nos Aspectos Emocionais (p=0,04) e apresentaram tendência a melhora em Dor e Aspectos Sociais. Pacientes com hemiparesia direita obtiveram resultados superiores aos com hemiparesia esquerda nos Aspectos Emocionais (p=0,02). CONCLUSÃO: A utilização da OEF na perna parética por AVE é eficaz em melhorar a qualidade de vida dos pacientes.


Subject(s)
Female , Humans , Male , Leg/physiology , Motor Skills/physiology , Orthotic Devices/standards , Paresis/rehabilitation , Quality of Life , Stroke/rehabilitation , Activities of Daily Living , Electric Stimulation , Outcome Assessment, Health Care , Paresis/physiopathology , Sex Factors , Social Adjustment , Surveys and Questionnaires , Stroke/physiopathology , Treatment Outcome , Walking/physiology
SELECTION OF CITATIONS