Braz. dent. sci ; 13(3/4): 15-21, 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-642717

ABSTRACT

Este estudo in vitro analisou, por meio da extensometria, as micro deformações que ocorreram ao redor de implantes de hexágono externo ao variar o tipo de coifa, plástica e usinada, após o aperto dos parafusos de retenção da prótese. No bloco de poliuretano três implantes de hexágono externo foram inseridos linearmente. Pilares protéticos Microunit foram conectados aos implantes com torque de 20 Ncm. Coifas plásticas (n=5) e usinadas (n=5) receberam enceramentos padronizados e foram fundidos em monobloco em liga de cobalto-cromo. No bloco de poliuretano, tangenciando os implantes foram colados os extensômetros, sendo dois para o central. As estruturas metálicas foram fixadas aos pilares protéticos com parafusos de retenção com torque de 10 Ncm, quando foram registradas as micro deformações (με) em cada extensômetro. Os valores médios obtidos dos extensômetros para as coifas plásticas foram de 363,37 με ± 237,66 e para as usinadas de 338,12 με ± 223,01. Estes foram avaliados pelo teste t-Student, que demonstrou não haver diferença estatística significante ao variar o tipo de coifa (p=0,867). Concluiu-se que, para implantes de hexágono externo posicionados linearmente, o tipo de coifa não influenciou na quantidade de micro deformação gerada após o aperto dos parafusos de retenção da prótese.


The objective of this in vitro study was quantify the micro strain development around the external hexagon implants, varying the type of prosthetic coping. Three implants of external hexagon were inserted into one polyurethane block. Microunit abutments were screwed onto the implants, applying a torque of 20Ncm. Plastic prosthetic copings (n=5) and machined copings (n=5) which received standard wax patterns were cast in Co-Cr alloy. On the surface of poliurtehane block tangentially the implants were bonded the strain gauges, two to the center implant. The super structure’s occlusal screws were tightened onto microunit abutments with 10 Ncm torque, the magnitude of micro strain was recorded. The mean values of each strain gauge of each plastic copings were 363,37 με ± 237,66 and the machined copings were 338,12 με ± 223,01. The data were analyzed statistically by t-Student test. No statistically significant difference was found between the prosthetic copings (p=0,867) It was concluded that to external hexagon implants in line placement, the type of coping presented similar magnitude of micro strain after prosthetic occlusal screw was tightened


Subject(s)
Dental Prosthesis, Implant-Supported , Plant Root Cap , Biomechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL