Braz. dent. j ; 23(6): 703-706, 2012. ilus, tab
Article in English | LILACS | ID: lil-662430

ABSTRACT

The aim of this study was to assess the applicability of gray scale inversion in performing digital linear endodontic measurements. Standardized digital images were taken of 40 extracted human permanent single-rooted teeth with K-files size 15 placed at different lengths in the root canal, using the CDR Wireless® digital system. All images were treated with Positive, a digital tool that inverts the grayscale value. Eight radiologists measured the distance between the lower limit of the rubber stop and the tip of the file on both original and positive images. After 15 days, they repeated this procedure in 50% of the image samples. The intra- and inter-examiner agreement was analyzed by intraclass correlation test, and the comparison between the two image groups and the actual lengths by the Student's t-test (α=0.05). Intra- and inter-examiner evaluation showed high reproducibility (r>0.95) of both original and positive images. No statistically significant differences (p>0.05) were found between measurements performed on original and positive images, but both differed significantly from the actual lengths (p<0.05). Gray scale inversion has low applicability in measuring endodontic files, since it did not improve the accuracy of measurements.


O objetivo deste estudo foi avaliar a aplicabilidade da inversão da escala de cinza na realização de mensurações endodônticas lineares digitais. Quarenta dentes unirradiculares humanos extraídos foram radiografados com limas K tamanho 15 posicionadas no canal radicular em diferentes comprimentos, usando o sistema digital CDR Wireless®. Todas as imagens foram tratadas com Positive, uma ferramenta digital que inverte os valores da escala de cinza. Oito radiologistas mediram a distância entre o limite inferior do stop de borracha e a ponta da lima endodôntica nas imagens originais e positivas. Após quinze dias, eles repetiram esse procedimento em 50% da amostra. A concordância intra- e interobservador foi analisada pelo teste de correlação intraclasse e a comparação entre os dois grupos de imagem e os valores reais, pelo teste t-Student (α=0,05). A análise intra- e interobservador apresentou elevada reprodutibilidade (r>0,95) das imagens original e Positive. Não foi encontrada diferença (p>0,05) entre as medidas realizadas nas imagens original e positiva, mas ambas diferiram dos valores reais (p<0,05). A inversão da escala de cinza tem baixa aplicabilidade na realização de mensuração endodôntica, considerando que as medidas não se apresentaram mais acuradas.


Subject(s)
Humans , Dental Pulp Cavity , Odontometry/methods , Radiography, Dental, Digital/methods , Tooth Apex , Dental Pulp Cavity/anatomy & histology , Image Processing, Computer-Assisted/methods , Image Processing, Computer-Assisted/statistics & numerical data , Observer Variation , Odontometry/statistics & numerical data , Phantoms, Imaging , Reproducibility of Results , Radiography, Dental, Digital/statistics & numerical data , Root Canal Preparation/instrumentation , Software , Tooth Apex/anatomy & histology
2.
Article in English | IMSEAR | ID: sea-140020

ABSTRACT

Background: Digital radiography has so far not resulted in improved rates of proximal caries detection. Historically, automated caries detection tools have been largely academic. Opinions regarding the performance of the only such commercially available tool, viz., Logicon caries Detector (LCD) have been equivocal. This study was conducted to evaluate the reliability of LCD in the detection and depth assessment of proximal caries. Materials and Methods: Digital images were obtained of 100 proximal tooth surfaces using the Kodak RVG 5000 sensor and analyzed by three observers. The images were then analyzed by the principal investigator using the LCD software. The teeth were then sectioned and magnified photographic images were obtained which were taken as the gold standard. All the grades were entered in proformas and the data were statistically analyzed using the chi-square test. Five parameters of reliability were calculated. Results: The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of LCD for the grade No caries were 33, 96, 73, 82, and 81%, respectively; for the grade Enamel caries were 5, 97, 33, 80, and 79%, respectively; and for the grade Dentin caries were 100, 96, 50, 100, and 96%, respectively. Conclusions: In conclusion, LCD appears to be more reliable in ruling out (both enamel and dentin) caries than in detecting caries.


Subject(s)
Bicuspid/pathology , Bicuspid/diagnostic imaging , Dental Caries/pathology , Dental Caries/diagnostic imaging , Dental Enamel/pathology , Dental Enamel/diagnostic imaging , Dentin/pathology , Dentin/diagnostic imaging , Humans , Image Processing, Computer-Assisted/standards , Image Processing, Computer-Assisted/statistics & numerical data , Molar/pathology , Molar/diagnostic imaging , Observer Variation , Photography, Dental , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted/standards , Radiography, Dental, Digital/standards , Radiography, Dental, Digital/statistics & numerical data , Sensitivity and Specificity , Software Validation
3.
Braz. dent. j ; 22(5): 404-409, 2011. ilus, graf, tab
Article in English | LILACS | ID: lil-601842

ABSTRACT

The aim of this study was to evaluate the accuracy of linear measurements made on conventional and digitized periapical and panoramic radiographic images of dry human hemi-mandibles. Images from the posterior region of 22 dry human hemi-mandibles were obtained by conventional panoramic and periapical radiography technique. Using a digital caliper, 3 vertical measurements were marked directly on the dry hemi-mandibles (reference measurements) as well as on the tracing from the conventional radiographic images of the specimens made onto acetate paper sheet: Distance 1: between the upper limit of the alveolar ridge and the lower limit at the mandible base; Distance 2: between the upper limit of the alveolar ridge and the upper limit of the mandibular canal; Distance 3: between the lower limit of the mandibular canal and the lower limit of the mandible base. Next, the radiographs were digitized and the three measurements were made on the digital images using UTHSCSA Image Tool software. Data were analyzed statistically by one-way ANOVA (α=0.05). There was no statistically significant differences (p>0.05) between periapical and panoramic radiographs or between the measurements recorded using the digital caliper and UTHSCSA software compared with dry mandible specimens for Distances 1 (p=0.783), 2 (p=0.986) and 3 (p=0.129). In conclusion, the radiographic techniques evaluated in this study are reliable for vertical bone measurements on selected areas and the UTHSCA Image Tool software is an appropriate measurement method.


O objetivo deste estudo foi avaliar a acurácia de medidas lineares realizadas em radiografias panorâmicas e periapicais convencionais e digitalizadas de hemimandíbulas humanas secas. Imagens da região posterior de 22 hemimandíbulas humanas secas foram obtidas pelas técnicas panorâmica e periapical convencionais. Com o paquímetro eletrônico digital, foram realizadas três medições verticais diretamente sobre as hemimandíbulas (medidas referenciais), bem como sobre o decalque das imagens convencionais, em papel de acetato: Distância 1: Distância entre o limite superior do rebordo alveolar e o limite inferior da base da mandíbula; Distância 2: Distância entre o limite superior do rebordo alveolar e o limite superior do canal mandibular e Distância 3: Distância entre o limite inferior do canal mandibular e o limite inferior da base da mandíbula. Posteriormente, as radiografias foram digitalizadas e as três medidas foram realizadas nas imagens digitais utilizando o programa UTHSCSA Image Tool. Os dados foram analisados estatisticamente pelo teste ANOVA a um critério (α=0,05). Não houve diferenças estatisticamente significantes (p>0,05) entre as radiografias panorâmicas e periapicais, assim como para as medidas obtidas com o paquímetro e pelo programa UTHSCSA Image Tool, quando comparados aos espécimes mandibulares, avaliando as distâncias 1 (p=0,783), 2 (p=0,986) e 3 (p=0,129). Em conclusão, as técnicas radiográficas avaliadas neste estudo mostraram-se confiáveis para mensurações ósseas verticais na área selecionada e o programa de digitalização de imagens UTHSCSA Image Tool é um método adequado de aferição.


Subject(s)
Humans , Cephalometry/standards , Mandible , Radiography, Bitewing/standards , Radiography, Dental, Digital/standards , Radiography, Panoramic/standards , Alveolar Process , Anatomic Landmarks , Cephalometry/statistics & numerical data , Image Processing, Computer-Assisted/standards , Image Processing, Computer-Assisted/statistics & numerical data , Reproducibility of Results , Radiography, Bitewing/statistics & numerical data , Radiography, Dental, Digital/statistics & numerical data , Radiography, Panoramic/statistics & numerical data , Software/standards , Software/statistics & numerical data
5.
Braz. oral res ; 20(2): 162-166, Apr.-June 2006. tab
Article in English | LILACS | ID: lil-432194

ABSTRACT

A documentação ortodôntica realizada em clínicas radiológicas é essencial para diagnóstico, planejamento e controle do tratamento ortodôntico. Dentre os elementos de diagnóstico utilizados estão as grandezas cefalométricas, e erros podem ser incorporados durante a obtenção das mesmas. O objetivo deste trabalho foi avaliar os valores de algumas grandezas cefalométricas obtidas em três clínicas radiológicas, utilizando-se 30 telerradiografias da cabeça em norma lateral, escolhidas ao acaso, do arquivo do Departamento de Clínica Infantil (Disciplina de Ortodontia) da Faculdade de Odontologia de Piracicaba - UNICAMP. Esses valores foram comparados com os das grandezas obtidas manualmente (grupo controle), utilizando-se a análise de variância e os testes de Tukey e Friedman. Os resultados demonstraram que das 14 medidas cefalométricas avaliadas, apenas 4 apresentaram diferenças estatisticamente significantes: IMPA, 1-NA, FMA, e H-nariz. Concluímos que apesar de a maioria dos valores médios das grandezas cefalométricas não apresentarem diferenças estatisticamente significantes, ao compararmos todos os valores obtidos em cada uma das radiografias, encontramos grande variabilidade nos resultados, o que pode interferir na interpretação das grandezas cefalométricas. Assim, os autores sugerem ao ortodontista, quando receber a documentação ortodôntica, realizar novamente as análises cefalométricas para comparar os valores das grandezas, e utilizar outros elementos para diagnóstico, planejamento e controle do tratamento ortodôntico.


Subject(s)
Humans , Cephalometry/standards , Orthodontics, Corrective , Radiography, Dental, Digital/standards , Analysis of Variance , Case-Control Studies , Cephalometry/statistics & numerical data , Data Interpretation, Statistical , Observer Variation , Reproducibility of Results , Radiography, Dental, Digital/statistics & numerical data
6.
Rev. dent. press ortodon. ortopedi. facial ; 11(1): 60-71, jan.-fev. 2006. tab
Article in Portuguese | LILACS | ID: lil-423307

ABSTRACT

OBJETIVO: avaliar cefalometricamente os efeitos da expansão rápida da sutura palatina mediana sobre o posicionamento vertical e sagital da maxila, comparando os aparelhos de Haas e Hyrax. METODOLOGIA: a amostra consistiu de 93 telerradiografias obtidas de 31 pacientes jovens, brasileiros, de ambos os gêneros, na faixa etária inicial média de 13 anos e 2 meses. As radiografias foram tomadas ao início do tratamento (pré-disjunção), imediatamente após a disjunção (pós-disjunção) e ao final do nivelamento. RESULTADOS E CONCLUSÕES: constatou-se que os dois aparelhos disjuntores apresentaram resultados semelhantes, com a ocorrência de deslocamento da maxila em direção inferior, sem rotação, que se manteve ao final do nivelamento e ocorrência de um deslocamento anterior logo após a disjunção, que retornou aos valores pré-disjunção ao final do nivelamento.


Subject(s)
Humans , Male , Female , Adolescent , Activator Appliances , Palatal Expansion Technique , Cephalometry , Radiography, Dental, Digital/statistics & numerical data