Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Repert. med. cir ; 19(3): 220-230, 2010. ilus
Article in Spanish | LILACS, COLNAL | ID: lil-585626

ABSTRACT

Nos proponemos enmarcar en la historia del Hospital de San José los orígenes y evolución del servicio de Imágenes Diagnósticas, uno de los primeros que hubo en el país.


We intend to frame in the history of Hospital de San José the origins and evolution of Diagnostic Imaging Services, one of the first that occurred in the country.


Subject(s)
History, 19th Century , History, 20th Century , Radiology/history , Radiology Department, Hospital/history , Colombia , History of Medicine
3.
Radiol. bras ; 37(4): 271-278, jul.-ago. 2004. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-364712

ABSTRACT

Foram realizados testes de controle de qualidade, descritos na Portaria 453/98 do Ministério da Saúde, em sete hospitais públicos do Rio de Janeiro, em um total de 29 tubos de raios X, 30 chassis e 20 vestimentas de proteção individual. Os testes avaliaram o desempenho do gerador de raios X e a geometria do feixe. Foram verificados, também, chassis, "écrans" e negatoscópios, assim como as câmaras claras e escuras. Alguns dos resultados encontrados foram: 55 por cento dos tubos foram reprovados em exatidão e 15 por cento em reprodutibilidade de kVp; 53 por cento foram reprovados em exatidão e 31 por cento em reprodutibilidade de tempo de exposição; 30 por cento foram reprovados em camada semi-redutora; 18 por cento foram reprovados no alinhamento do feixe central; 30 por cento foram reprovados em coincidência de campos; 40 por cento foram reprovados na linearidade de exposição; 64 por cento foram rejeitados no teste de ponto focal. Foram verificadas a guarda inadequada e a falta de recomendação para uso dos aventais plumbíferos. Os resultados dos testes sugerem a necessidade da implementação sistemática de controle de qualidade por um profissional qualificado. A relação de custo-benefício reforça a implantação e a manutenção dos procedimentos contidos e executados neste trabalho, pois tais procedimentos garantiriam a diminuição do custo final do serviço e da dose nos pacientes.


Quality control tests, according to "Portaria 453/98" of the Brazilian Health Ministry, were applied in seven public hospitals of Rio de Janeiro including 29 X-ray tubes, 30 cassettes and 20 individual protection garments. These tests evaluate mainly the X-ray generator and system geometry. Other tests in the accessories were also performed, such as: cassettes, screens, viewing boxes, darkrooms and clear rooms. In the kVp tests, 55% of the equipments were disapproved in exactitude and 15% in reproducibility. Time exactitude and reproducibility were not approved in 53% and 31% of the equipments, respectively. The percentages of disapprovement were: for the HVL (half-value layer) 30%, for beam alignment 18%, for field coincidence 30%, for exposure linearity 40% and for focal spot 64%. It has also been observed that frequently the lead aprons were not kept in appropriate hangers and this procedure may cause damage to these accessories. The results of the test suggest the need of implementation of quality assurance tests in these services. The cost benefit analysis of the results reinforces the importance of the implementation of the recommendations contained in this paper.


Subject(s)
Humans , Radiology Department, Hospital , Radiology Information Systems , Radiology Department, Hospital , Quality Control , Radiography/instrumentation , Radiology Department, Hospital/history , Radiology Information Systems/classification
5.
Rev. med. (Säo Paulo) ; 81(n.esp): 38-43, nov. 2002. ilus
Article in Portuguese | LILACS | ID: lil-324838

ABSTRACT

Ao inaugurar-se o ensino da Faculdade de Medicina de Sao Paulo em 1913, a fisica medica foi instituida como disciplina basica, sendo provido na catedra o Dr. Edmundo Xavier, estabelecendo-se o programa do curso nos moldes...


Subject(s)
Radiology , Schools, Medical/history , Radiology Department, Hospital/history
SELECTION OF CITATIONS
SEARCH DETAIL