1.
Journal of Biomedical Engineering ; (6): 1200-1208, 2023.
Article in Chinese | WPRIM | ID: wpr-1008951

ABSTRACT

For the transportation process of rescuing wounded personnel on naval vessels, a new type of shoulder type exoskeleton stretcher for individual soldier was designed in this paper. The three-dimensional model of the shoulder type exoskeleton stretcher for individual soldier was constructed using three dimensional modeling software. Finite element analysis technique was employed to conduct statics simulation, modal analysis, and transient dynamics analysis on the designed exoskeleton stretcher. The results show that the maximum stress of the exoskeleton stretcher for walking on flat ground is 265.55 MPa, which is lower than the allowable strength of the fabrication material. Furthermore, the overall deformation of the structure is small. Modal analysis reveals that the natural frequency range of the exoskeleton stretcher under different gait conditions is 1.96 Hz to 28.70 Hz, which differs significantly from the swing frequency of 1 Hz during walking. This indicates that the designed structure can effectively avoid resonance. The transient dynamics analysis results show that the maximum deformation and stress of exoskeleton stretcher remain within the safety range, which meets the expected performance requirements. In summary, the shoulder type exoskeleton stretcher for individual soldier designed in this study can solve the problem of requiring more than 2 people to carry for the existing stretcher, especially suitable for narrow spaces of naval vessels. The research results of this paper can provide a new solution for the rescue of wounded personnel on naval vessels.


Subject(s)
Humans , Stretchers , Military Personnel , Shoulder , Exoskeleton Device , Walking , Gait , Biomechanical Phenomena
2.
Chinese Journal of Contemporary Pediatrics ; (12): 435-440, 2020.
Article in Chinese | WPRIM | ID: wpr-828726

ABSTRACT

OBJECTIVE@#To study the effect and safety of vacuum stretcher combined with feeding in cranial magnetic resonance imaging (MRI) examination for neonates.@*METHODS@#A prospective study was performed for the neonates with hyperbilirubinemia, with a gestational age of >34 weeks and stable vital signs, who needed cranial MRI examination and did not need oxygen inhalation hospitalized in the Department of Neonatology, Children's Hospital of Zhejiang University School of Medicine, from September to November, 2019. The neonates were randomly divided into a vacuum stretcher combined with feeding group and a conventional sedation group. Vital signs were monitored before, during, and after MRI examination. The success rate of MRI procedure was recorded.@*RESULTS@#A total of 80 neonates were enrolled in the study, with 40 neonates in the vacuum stretcher combined with feeding group and 40 in the conventional sedation group. The vacuum stretcher combined with feeding group had a significantly higher success rate of MRI procedure than the conventional sedation group (P0.05). No complications, such as apnea, acute allergic reactions, and malignant fever, were observed.@*CONCLUSIONS@#Vacuum stretcher combined with feeding can improve the success rate of MRI procedure and reduce the use of sedatives, and meanwhile, it does not increase related risks.


Subject(s)
Humans , Infant, Newborn , Hypnotics and Sedatives , Magnetic Resonance Imaging , Prospective Studies , Stretchers , Vacuum
5.
Clinics ; 72(6): 325-332, June 2017. tab, graf
Article in English | LILACS | ID: biblio-840090

ABSTRACT

OBJECTIVES: To analyze the influence of lying in prone position on a specially designed stretcher on the maternal-fetal hemodynamic parameters and comfort of pregnant women. METHODS: A randomized, controlled trial with 33 pregnant women divided into 2 groups: pregnant group sequence 1 and pregnant group sequence 2. The order of positions used in sequence 1 was Fowler’s position, prone position, supine position, left lateral, Fowler’s position 2, supine position 2, prone position 2 and left lateral 2. The order of positions used in sequence 2 was Fowler’s position, prone position, left lateral, supine position, Fowler’s position 2, left lateral 2, prone position 2 and supine position 2. Each woman remained in each position for 6 minutes. For the statistical analyses, we used Wilcoxon’s test for 2 paired samples when comparing the prone position with the other positions. The variables are presented in graphs showing the means and 95% confidence intervals. Trial Registration: Clinical Trial No. ISRCTN41359519 RESULTS: All the parameters were within the standards of normality. There were no differences between positions in terms of maternal heart rate, diastolic blood pressure, oxygen saturation and fetal heart rate. However, there were significant decreases in respiratory rate and systolic blood pressure in prone position 2 compared with left lateral 2. There was an increase in oxygen saturation in prone position compared with Fowler’s position and supine position 2 in both sequences. All the women reported feeling comfortable in the prone position. CONCLUSIONS: The prone position was considered safe and comfortable and could be advantageous for improving oxygen saturation and reducing the systolic blood pressure and respiratory rate.


Subject(s)
Humans , Female , Adult , Young Adult , Hemodynamics/physiology , Pregnancy/physiology , Prone Position/physiology , Stretchers , Patient Comfort
6.
Recife; s.n; 2017. 45 p.
Thesis in Portuguese | ColecionaSUS, CONASS, LILACS, SES-PE | ID: biblio-1121596

ABSTRACT

Este trabalho de intervenção propõe implantação de um fluxo funcional para os serviços de urgência/emergência hospitalar, que compõem a rede de referência macrorregional em Pernambuco. Aborda critérios relativos à estrutura (física-organizacional, recursos materiais e humanos) e ao processo (atividades de rotina), apontando que as Unidades Hospitalares devem possuir um fluxo de rotina funcional para a liberação das macas dos serviços de atendimento móvel de urgência como as viaturas do SAMU 192 e do Corpo de Bombeiros Militar de Pernambuco (CBMPE). Como também a buscativa de melhorar o desempenho quanto ao processo de trabalho (resgate, admissão no hospital e liberação da maca de resgate); Os resultados nesse trabalho evidenciam sua racionalidade, coerência, consistência e factibilidade (termos técnicos, econômicos e políticos) considerando-o válido e aceito pelos envolvidos no processo e na sua execução em todos os espaços possíveis, pois segue na direção da resolução do problema, contribuindo para o debate e o desenvolvimento de políticas públicas intersetoriais.(AU)


Subject(s)
Emergency Service, Hospital , Workflow , Stretchers , Hospital Administration
7.
Hist. ciênc. saúde-Manguinhos ; 23(3): 887-897, jul.-set. 2016.
Article in Spanish | LILACS | ID: lil-792561

ABSTRACT

Resumen En mayo de 1875, en medio de una sangrienta contienda civil en España conocida como Tercera Guerra Carlista, Nicasio Landa, oficial médico de Sanidad Militar redactó un informe demandando autorización a sus superiores para que Cruz Roja Española, de la que era inspector general, pudiera adoptar un nuevo sistema de suspensión elástica para camillas que había diseñado, desarrollado y probado. Destinado ante todo a carretas de labranza – el medio de transporte de heridos aún más frecuente entonces – se presentaba como un mecanismo económico y resistente para mejorar el confort de los trasladados, que podía también instalarse en carruajes de ambulancia, vagones de ferrocarril y buques-hospitales. Se publica una edición anotada del informe precedida de una presentación del mismo.


Abstract In May 1875, in the midst of a bloody civil conflict in Spain known as the Third Carlist War, Nicasio Landa, a medical officer with Military Health, wrote a report requesting authorization for the Spanish Red Cross, of which he was Inspector General, to adopt a new elastic suspension system for stretchers that he had designed, developed and tested. Intended above all for use in farm wagons – still the most widely-used method of transporting the wounded at the time – it was an inexpensive, sturdy mechanism that improved patient comfort and could also be installed in ambulance carriages, railway carriages and hospital ships. An annotated version of the report is included, preceded by a presentation of its contents.


Subject(s)
Humans , History, 21st Century , Military Medicine/history , Stretchers/history , Transportation of Patients/history , Armed Conflicts/history , Inventions/history , Military Personnel/history , Wounds and Injuries/history
8.
Health SA Gesondheid (Print) ; 17(1): 1-7, 2012.
Article in English | AIM | ID: biblio-1262506

ABSTRACT

Cardiac arrest is a life-threatening emergency situation. The outcome depends on timely and effective cardio-pulmonary resuscitation (CPR). Successful CPR attempts in hospitals require well-equipped emergency trolleys and properly functioning equipment; as well as staff members skilled in performing CPR. The study aimed to determine whether the emergency trolleys in Botswana's hospitals' wards or units met the expected standards. The contents of the emergency trolleys in 20 wards or units of two referral government hospitals in Botswana were audited by using a standardised checklist. No hospital ward or unit had all the expected equipment or drugs on its emergency trolley; some units failed to check their emergency trolleys' contents daily. All 20 hospital wards or units that participated in this study; needed to improve the contents and maintenance of their emergency trolleys; otherwise in-hospital CPR efforts in Botswana might be doomed to failure; losing lives that could have been saved if emergency trolleys' equipment and supplies had been up to standard


Subject(s)
Cardiopulmonary Resuscitation , Equipment and Supplies , Heart Arrest , Medical Audit , Patients , Stretchers