Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Braz. j. otorhinolaryngol. (Impr.) ; 85(4): 502-509, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019574

ABSTRACT

Abstract Introduction: The conventional evaluation of neural telemetry and impedance requires the use of the computer coupled to an interface, with software that provides visualization of the stimulus and response. Recently, a remote control (CR220®) was launched in the market, that allows the performance of intraoperative tests with minimal instrumentation. Objective: To evaluate the agreement of the impedance values and neural telemetry thresholds, and the time of performance in the conventional procedure and by the remote control. Methods: Multicentric prospective cross-sectional study. Intraoperative evaluations of cochlear implants compatible with the use of CR220® were included. The tests were carried out in the 22 electrodes to compare the time of performance in the two situations. The agreement of the neural telemetry threshold values obtained from five electrodes was analyzed, and the agreement of impedance was evaluated by the number of electrodes with altered values in each procedure. Results: There were no significant difference between the impedance values. There was a moderate to strong correlation between the electrically-evoked compound action potential thresholds. The mean time to perform the procedures using the CR220 was significantly lower than that with the conventional procedure. Conclusion: The use of the CR220 provided successful records for impedance telemetry and automatic neural response telemetry.


Resumo Introdução: A avaliação convencional da telemetria neural e de impedâncias implica o uso do computador acoplado a uma interface, o software fornece o estímulo e a visualização das respostas. Recentemente, foi lançado um controle remoto (CR220®), que possibilita testes intraoperatórios com instrumental mínimo. Objetivo: Avaliar a concordância dos valores das impedâncias e dos limiares da telemetria neural e o tempo de execução no procedimento convencional e pelo controle remoto. Método: Estudo prospectivo transversal multicêntrico. Foram incluídas as avaliações intraoperatórias de implante coclear compatível com o uso do CR220®. Os testes foram realizados nos 22 eletrodos para comparar os tempos de execução nas duas situações. Foi analisada a concordância dos valores do limiar da telemetria neural obtidos em cinco eletrodos e a concordância das impedâncias foi avaliada pelo número de eletrodos com valores alterados em cada procedimento. Resultados: Não houve diferença significante entre as impedâncias. Obteve-se moderada a forte correlação entre os limiares do potencial de ação composto eletricamente evocado. O tempo médio para os procedimentos com o CR220 foi significativamente menor do que com o procedimento convencional. Conclusão: O uso do CR220 proporcionou registros bem-sucedidos para a telemetria de impedância e a telemetria automática de respostas neurais.


Subject(s)
Humans , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Telemetry/instrumentation , Cochlear Implants , Cochlear Implantation/instrumentation , Deafness/surgery , Auditory Threshold , Acoustic Impedance Tests , Cross-Sectional Studies , Prospective Studies , Cochlear Implantation/methods , Deafness/etiology , Evoked Potentials, Auditory
2.
Rev. biol. trop ; 64(4): 1441-1450, oct.-dic. 2016. tab, ilus
Article in English | LILACS | ID: biblio-958225

ABSTRACT

Abstract:Telemetry based on Global Positioning Systems (GPS) makes possible to gather large quantities of information in a very fine scale and work with species that were impossible to study in the past. When working with GPS telemetry, the option of storing data on board could be more desirable than the sole satellite transmitted data, due to the increase in the amount of locations available for analysis. Nonetheless, the uncertainty in the retrieving of the collar unit makes satellite-transmitted technologies something to take into account. Therefore, differences between store-on-board (SoB) and satellite-transmitted (IT) data sets need to be considered. Differences between SoB and IT data collected from two lowland tapirs (Tapirus terrestris), were explored by means of the calculation of home range areas by three different methods: the Minimum Convex Polygon (MCP), the Fixed Kernel Density Estimator (KDE) and the Brownian Bridges (BB). Results showed that SoB and IT data sets for the same individual were similar, with fix ranging from 63 % to 85 % respectively, and 16 m to 17 m horizontal errors. Depending on the total number of locations available for each individual, the home ranges estimated showed differences between 2.7 % and 79.3 %, for the 50 % probability contour and between 9.9 % and 61.8 % for the 95 % probability contour. These differences imply variations in the spatial coincidence of the estimated home ranges. We concluded that the use of IT data is not a good option for the estimation of home range areas if the collar settings have not been designed specifically for this use. Nonetheless, geographical representations of the IT based estimators could be of great help to identify areas of use, besides its assistance to locate the collar for its retrieval at the end of the field season and as a proximate backup when collars disappear. Rev. Biol. Trop. 64 (4): 1441-1450. Epub 2016 December 01.


Resumen:La telemetría basada en los sistemas de geopocisionamiento global (GPS) hace posible recopilar gran cantidad de información a escalas muy finas, y trabajar con especies imposibles de estudiar en el pasado. Al trabajar con telemetría de GPS, la opción de guardar información en la memoria interna del instrumento puede ser más deseable que sólo tener acceso a la información enviada vía satélite, debido a la mayor cantidad de localizaciones disponibles para analizar. No obstante, la incertidumbre de recuperar el collar hace que las tecnología de trasmisión vía satélite deba ser tenida en cuenta. Diferencias entre las bases de datos almacenadas en el collar (SoB) y las trasmitidas vía satélite (IT), recolectadas de dos individuos de Tapir de tierras bajas (Tapirus terrestris), son consideradas, en términos de las áreas de los rangos de hogar calculados con cada uno y mediante el uso de tres metodologías diferentes: Mínimo Polígono Convexo (MCP), Estimador de Densidad de Kernel Fijo (KDE) y los Puentes Brownianos (BB). Las bases de datos SoB e IT son similares, con tasas de acierto de localizaciones que oscilan entre 63 % to 85 % y errores horizontales de 16 m y 17 m respectivamente. Dependiendo del número total de localizaciones disponibles para cada individuo, los rangos de hogar estimados muestran diferencias entre 2.7 % y 79.3 %, para el contorno del 50 % de probabilidades, y entre 9.9 % y 61.8 % para el contorno del 95 % de probabilidades. Estas diferencias implican variaciones en la coincidencia espacial de los rangos de hogar estimados. Concluimos que el uso de la información trasmitida vía satélite no es una buena opción para la estimación de rangos de hogar, si la programción de los collares no ha sido diseñada específicamente para tal fin. Sin embargo, las representaciones geográficas de los estimados a partir de las bases de datos IT pueden ser de gran ayuda para la identificación de áreas de uso, además de su utilidad para la localización y recuperación de collares tras su liberación de los individuos monitoreados y como una base de datos de soporte en caso de pérdida del collar.


Subject(s)
Animals , Male , Female , Perissodactyla , Telemetry/instrumentation , Telemetry/methods , Satellite Communications/instrumentation , Geographic Information Systems/instrumentation , Homing Behavior , Time Factors , Sex Factors , Reproducibility of Results , Colombia , Animal Distribution , Datasets as Topic , Iridium
4.
Rev. bras. eng. biomed ; 23(3): 231-244, dez. 2007. ilus, graf
Article in Portuguese | LILACS | ID: lil-507729

ABSTRACT

Este trabalho apresenta uma rede de sensores utilizada para monitoração de variáveis fisiológicas do corpo humano com suporte à programação. A tarefa de configuração dese tipo de sistema é usualmente realizada por desenvolvedores especializados, profissionais da computação com grande conhecimento de linguagens de programação. Entretanto, para que essa tecnologia se torne clinicamente viável, é necessário que os próprios profissionais da área de saúde possam fazê-lo. A programação e a reconfiguração à distância de uma rede de sensores sem fios é o principal objetivo deste trabalho. Como contribuição maior é apresentada uma arquitetura de software denominada SOAB (Software Architecture for Bodyworn Sensor Networks Project). Concebida com base em uma abordagem top-down, a arquitetura SOAB é constituída por quatro camadas independentes: i)uma interface gráfica direcionada aos profissionais de saúde; ii)middleware para interconexão da rede de sensores para monitoração do corpo humano com a Internet;iii)um servidor para execução dos serviços solicitados pelos programadores; e iv)um sistema operacional com suporte para multitarefa que será embutido nos sós-sensores. Esse sistema operacional foi denominado MedOS e visa aumentar a sobrevida dos nós-sensores (tempo de operação), promovendo a redução do consumo de energia elétrica por meio do escalonamento de tarefas com base em políticas adaptadas para aplicações biomédicas. A sistematização dessas políticas foi obtida por meio da utilização de um modelo baseado em autômatos. Para avaliar a arquitetura SOAB foi elaborado e aplicado um teste de carga, cujo objetivo foi quantificar o tempo gasto para programação de um nó-sensor do eletrocardiograma (ECG). Os resultados dos testes mostraram que o sistema proposto tem um bom potencial para se tornar uma ferramenta eficiente para a programação de redes de sensores para monitoração do corpo humano por profissionais não-especializados na área de informática.


Subject(s)
Biological Factors , Medical Informatics/trends , Neural Networks, Computer , Networks on Water Quality Monitoring/methods , Computer Graphics , Signal Processing, Computer-Assisted/instrumentation , Telemetry/instrumentation , Telemetry/methods , Telemetry
5.
Neotrop. ichthyol ; 5(2): 103-108, 2007. ilus, tab
Article in English | LILACS | ID: lil-457666

ABSTRACT

A preliminary study on the application of radio-telemetry techniques to describe the movements of fish in a bypass channel at Itaipu Dam (Paraná River), known as "Canal da Piracema," was carried out between January and February of 2004. Fourteen individuals of six species (Prochilodus lineatus, Leporinus friderici, Schizodon borellii, Pseudoplatystoma fasciatum, Pterodoras granulosus and Cichla kelberi) were intragastrically and surgically radiotagged and monitored by three experimental fixed radio-telemetry stations installed in the upper portion of the Canal. The surgical implantation of transmitters and the anesthesia using clove oil proved to be more efficient and allowed easier handling in comparison to intragastric implantation and electronarcosis immobilization. The use of fixed stations to obtain data was found to be very suitable for tracking movements of several different fish species in the Itaipu lateral channel. Three species (P. granulosus, S. borellii and C. kelberi) moved downstream after release. Two individuals of P. fasciatum and two of P. lineatus migrated upstream, leaving the channel 7 and 10 days and 2 and 24 days after release, respectively. Leporinus friderici was the only species that did not leave the release site until the end of the study period


Um estudo preliminar sobre a aplicação de técnicas de radiotelemetria para descrever os movimentos de peixes no canal de transposição da UHE Itaipu (Rio Paraná), conhecido como "Canal da Piracema", foi realizado entre janeiro e fevereiro de 2004. Seis espécies (Prochilodus lineatus, Leporinus friderici, Schizodon borellii, Pseudoplatystoma fasciatum, Pterodoras granulosus e Cichla kelberi) totalizando 14 indivíduos foram marcadas com radiotransmissores via cirúrgica e esofágica e rastreados através de três estações fixas experimentais de radiotelemetria instaladas na porção superior do Canal. A implantação de transmissores através de cirurgia e a anestesia por óleo de cravo mostraram-se mais eficientes e de fácil manejo do que a imobilização por eletronarcose e a implantação intragástrica. A utilização de estações fixas para obtenção dos dados mostrou-se apropriada para rastrear os movimentos de diferentes espécies no canal de transposição de Itaipu. Três espécies (P. granulosus, S. borellii e C. kelberi) movimentaram-se para jusante após a soltura. Dois indivíduos de P. fasciatum e dois de P. lineatus migraram para montante, deixando o canal 7 e 10 dias e 2 e 24 dias após a soltura, respectivamente. Leporinus friderici foi a única espécie que não deixou o local de soltura até o final do estudo


Subject(s)
Animals , Animal Migration , Biodiversity , Environmental Monitoring , Fishes/metabolism , Dams/prevention & control , Telemetry/instrumentation
6.
Neotrop. ichthyol ; 5(2): 229-232, 2007. tab, graf
Article in English | LILACS | ID: lil-457681

ABSTRACT

Jaú, Zungaro jahu (Ihering, 1898), a large migratory catfish endemic to the rio da Prata basin, has a fragile conservation status and its ecology is poorly known. We radio-tracked a female jaú with a total length of 1.5 m that was passed upstream of Funil Dam, rio Grande, to describe its migratory movements, habitat use, linear home range, and diel activity. To track the fish, we made five tracking trips in the period from April, 2003 to January, 2004. In addition to the main body of Funil Reservoir, the fish also used a reservoir-river transition zone located in a branch of Funil Reservoir that flooded part of rio das Mortes. Most of the times, we found the fish in the former beds of streams flooded by the reservoir, at depths that ranged from 8-9 m in the reservoir-river transition zone to 18-21 m in Funil Reservoir. Linear home range of the fish was 31.4 km. The onset of activity occurred early in the evening, but we also detected daytime activity. The conclusion from our study was that the passed adult female jaú used reservoir habitats, migrated between the main body and the reservoir-river transition zone, preferred deep habitats, showed a relatively short home range, and had diurnal and nocturnal activities


O jaú, Zungaro jahu (Ihering, 1898), é um bagre migrador de grande porte endêmico da bacia do rio da Prata, possui frágil status de conservação e sua ecologia é pouco conhecida. Nós rastreamos uma fêmea adulta de 1,5 m de comprimento total transposta para montante da barragem de Funil, rio Grande, para descrever movimentos migratórios, uso do hábitat, área de vida e atividade circadiana. Fizemos cinco viagens, de abril de 2003 a janeiro de 2004, para localização do peixe marcado. O indivíduo utilizou a zona de transição reservatório-rio, localizada no braço do reservatório de Funil que alagou parte do rio das Mortes. O peixe também utilizou o corpo principal do reservatório. Nós o encontramos principalmente nos antigos leitos dos rios que foram alagados em profundidades que variaram de 8-9 m, na zona de transição reservatório-rio, a 18-21 m, no corpo principal do reservatório de Funil. A área de vida linear foi de 31,4 km. O período de atividade ocorreu no início da noite mas também encontramos atividade durante o dia. Concluindo, este estudo demonstrou que a fêmea adulta de jaú transposta usou hábitats do reservatório, migrando entre o corpo principal e a zona de transição reservatório-rio, preferiu ambientes profundos, apresentou área de vida pequena, e mostrou atividade diurna e noturna


Subject(s)
Animals , Female , Adult , Animal Migration , Endangered Species/analysis , Fishes , Ecosystem/adverse effects , Telemetry/instrumentation , Telemetry/methods
7.
Article in English | IMSEAR | ID: sea-90624

ABSTRACT

Due to the rapid growth of mobile telecommunications it is predicted that by 2005 there will be 1.6 billion mobile phone users worldwide. The usage of cellphones in Intensive Care Units carries with it a high incidence of interference with a number of medical devices like implantable defibrillators, cardioverters, pacemakers, monitors and other important devices like ventilators. It is in this context that this article will throw a light on complications of cellphones use in the Intensive Care Units and various strategies that can be taken to restrict their use in the Intensive Care Units.


Subject(s)
Cell Phone/statistics & numerical data , Defibrillators, Implantable , Electromagnetic Fields/adverse effects , Equipment Failure , Equipment Failure Analysis , Humans , Intensive Care Units/standards , Microwaves/adverse effects , Organizational Policy , Pacemaker, Artificial , Telemetry/instrumentation
8.
Indian Heart J ; 1998 Jan-Feb; 50(1): 55-8
Article in English | IMSEAR | ID: sea-3560

ABSTRACT

Between May 1996 and May 1997, a total of 398 patients (321 males, 77 females) were registered at our institute for trans-telephonic electro-cardiographic monitoring (TTEM). Their age ranged from one month to 95 years. Almost two-third (67%) of patients were from Delhi and one-third (33%) from other places in India and neighbouring countries. Clinical profile of these patients was post-bypass surgery, post-myocardial infarction, chest pain for evaluation, post-percutaneous transluminal coronary angioplasty, chronic stable angina, evaluation of palpitations, arrhythmias, and pace-maker follow-up. Out of 664 symptomatic transmissions, 568 (86%) were received for cardiac symptoms and 96 (14%) for non-cardiac symptoms. Seventy-nine percent patients had chest pain or palpitations at the time of transmission, whereas 21 percent had other symptoms like chest discomfort, breathlessness or dizziness. The electro-cardiograms were transmitted within one hour of the onset of chest pain in 84 percent, palpitations in 78 percent and dizziness in 75 percent. Of patients with symptomatic transmissions, 628 (95%) required either reassurance or drug-dose adjustment and outpatient department review. Only 36 (5%) patients were hospitalised as an emergency, and out of these only 19 (3%) needed acute management. In conclusion, trans-telephonic electro-cardiographic monitoring is a very convenient and an 'all-time-available' monitoring facility for establishing patient-physician contact in the shortest time. It is useful in rendering instant advice for hospitalisation in emergency situations while avoiding unnecessary visits to the hospital.


Subject(s)
Adolescent , Adult , Aged , Aged, 80 and over , Cardiology/methods , Cardiovascular Diseases/diagnosis , Child , Child, Preschool , Electrocardiography/instrumentation , Female , Humans , India , Infant , Male , Middle Aged , Rural Population , Sensitivity and Specificity , Telemedicine/instrumentation , Telemetry/instrumentation
9.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.267-268, ilus, graf.
Monography in Portuguese | LILACS | ID: lil-236349

ABSTRACT

Métodos simplificados para o cálculo de mútua indutância entre uma bobina circular e solemóide, visando a otimização de sistemas de comunicação aplicados à biotelemetria, são apresentados e discutidos em detalhes. Resultados experimentais, mostrando o grau de validade da análise desenvolvida, são também apresentados.


Simplified methods for calculation of the mutual inductance between a circular coil and solenoid, devised to optimize the communication systems applied in biotelemetry, are presented and discussed in details. Experimental results, showing the degree of validation of the developed analysis, are also presented.


Subject(s)
Research Design , Telemetry/instrumentation
10.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.265-266, ilus, graf.
Monography in Portuguese | LILACS | ID: lil-236348

ABSTRACT

Métodos simplificados para o cálculo da mútua indutância entre duas bobinas circulares coaxiais, visando a otimização de sistemas de comunicação aplicados à biotelemetria, são apresentados e discutidos em detalhes. Resultados experimentais, mostrando o grau de validade de análise desenvolvida, são também apresentados.


Simplified methods for calculation of the mutual inductance between two circular coaxial coils, devised to optimize the communication systems applied in biotelemetry, are presented and discussed in details. Experimental results, showing the degree of validation of the developed analysis, are also presented.


Subject(s)
Research Design , Telemetry/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL