Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add filters








Year range
1.
Journal of Mashhad Dental School. 2005; 28 (3-4): 269-274
in Persian | IMEMR | ID: emr-72026

ABSTRACT

Dental radiography has a major role in diagnosis of oral and dental diseases. Different technical methods are used to obtain high quality image in radiography and reduce X-Ray exposure in the patients. In this research modified techniques for periapical intraoral radiography with parallel technique by using XCP and Snap-A-Ray film holders had been used to overcome technical errors. With the use of XCP and Snap-A-Ray film holders, 96 parallel periapical intraoral radiographs were taken from 96 patients who were reffered to the radiology department of Isfahan dental school with the same condition of operation such as voltage [70 kvp]. Amp [8 mA]. The type of radiography films was E speed. From 96 radiographs, 6 of them were included in the pilot study and 90 radiographs were processed automatically [processor] in the same condition and after observation by the radiologist, the reports were written in the checklist. Evaluation of intraoral radiographs obtained by use of Snap-A-Ray film holder, showed technical errors of cone cutting [26.7%], displacement [15.6%], foreshortening [13.3%], elongation [8.9%] and overlapping [2.2%] whereas none of these technical errors were observed in intraoral radiographs obtained by use of XCP film holders. Totally the XCP film holders are easier to use and image quality of radiographs are better than those of Snap-A-Ray film holders. Regarding to the absence of technical errors and better image quality using XCP film holders, these film holders are preferrred which prevents repetition of radiography and reduces patient x-ray exposure dosage


Subject(s)
Humans , Radiography, Dental/methods , X-Rays , X-Ray Film/classification , Radiation Dosage , Diagnostic Errors
2.
Rev. Fac. Odontol. Bauru ; 8(1/2): 51-7, jan.-jun. 2000. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-298441

ABSTRACT

Analisou-se a utilizaçäo da densidade radiográfica (D.R.) como substituto da densidade ótica (D.O.) no controle de processamento radiográfico de filmes periapicais DF-58 que foram sensibilizados pelo aparelho de raios X GE 100. Os filmes foram divididos em cinco faixas, sendo que uma näo foi exposta, servindo para avaliaçäo da densidade base e velamento e as outras quatro faixas foram expostas com 1, 10, 60 e 300 impulsos, os quais foram processados manualmente em soluçäo Kodak em grupos de três nas temperaturas de 20º, 25ºC e 30ºC, com diferentes tempos. Para se avaliar a densidade ótica utilizou-se o fotodensitômetro MRA e para a avaliaçäo das densidades radiográficas escanearam-se as radiografias e utilizou-se o programa Digora for Windows 1.51 que forneceu dados, que puderam ser comparados com aqueles obtidos pelo método tradicional. Os resultados mostraram que a densidade ótica medida pelo fotodensitômetro, apresentou uma variaçäo correspondente aos níveis de cinza e variou conforme o número de impulsos nas faixas. Concluiu-se que as imagens das radiografias digitalizadas nas diferentes combinaçöes de temperatura/tempo nos fornecem uma grande precisäo de resultados e rapidez no controle de qualidade e podem substituir o fotodensitômetro na avaliaçäo das imagens de filmes radiográficos processados manualmente


Subject(s)
X-Ray Film/classification , X-Ray Film/standards , Diagnostic Imaging/methods , Image Processing, Computer-Assisted , Radiographic Image Interpretation, Computer-Assisted , Technology, Radiologic/classification , Technology, Radiologic/methods , Technology, Radiologic/trends
3.
Rev. Fac. Odontol. Bauru ; 7(3/4): 39-45, jul.-dez. 1999. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-298405

ABSTRACT

Analisou-se a utilizaçäo das Densidades Radiográfica (DR) e Densidade Radiográfica invertida (DRi), obtidas pelo uso do programa de imagem Adobe Photoshop 4.0, para substituir a Densidade Óptica (DO) na avaliaçäo dos filmes e soluçöes de processamento. Utilizamos tiras de filme TMS-1 que após serem expostas no sensitômetro MRA por 0,5 segundo, foram processadas na soluçäo RP X-Omat da Kodak na processadora automática CRONEX T4, na temperatura de 34ºC. Utilizamos o fotodensitômetro MRA para avaliar a Densidade Óptica (DO). Para analisar a DR e DRi, as tiras de filmes foram escaneadas (Scanjet HP 4C/T), e utilizamos o programa Adobe Photoshop 4.0, para obtençäo dos resultados (DR e DRi). Esses dados serviram para avaliar a soluçäo de processamento radiográfico quanto a sua atividade e degradaçäo. Pelos resultados, concluímos que a Densidade Óptica, Densidade Radiográfica e Densidade Radiográfica invertida tiveram resultados semelhantes variando com valores mais altos quando a soluçäo era nova e valores mais baixos quando da degradaçäo da soluçäo. Ainda podemos concluir que as leituras das tiras realizadas no fotodensitômetro podem ser substituídas pelas leituras digitalizadas com a vantagem de ser mais objetiva, de diminuir o tempo para obtençäo dos dados de Densidade Radiográfica e Densidade Radiográfica invertida


Subject(s)
X-Ray Film/adverse effects , X-Ray Film/classification , X-Ray Film/standards , Radiography, Dental, Digital/classification , Radiography, Dental, Digital/instrumentation , Radiography, Dental, Digital/methods , Radiographic Image Interpretation, Computer-Assisted , Signal Processing, Computer-Assisted/instrumentation , Software/classification , Software/standards
5.
Bauru; s.n; 1999. 113 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-250831

ABSTRACT

Este trabalho teve o objetivo de analisar a utilizaçäo das Densidades Radiográfica (D.R) e Radiográfica invertida (D.Ri), obtidas pelo uso do "software"de imagem Adobe Photoshop 4.0, para substituir a Densidade Óptica (D.O) na avaliaçäo dos filmes e soluçöes de processamento. Utilizamos tiras de filmes extrabucais TMS-1 que após serem expostas no sensitômetro MRA por 0,5 segundo, foram processadas na soluçäo RP X-OMAT da Kodak na processadora automática CRONEX T4 da DU PONT, nas temperaturas de 27ºC, 29ºC, 31ºC e 34ºC. Utilizamos o fotodensitômetro M R A para avaliar a Densidade Óptica (D.O). Para analisar a Densidade Rdaiográfica (D.R) e Densidade Radiográfica invertida (D.Ri), as tiras de filmes foram escaneadas (Scanjet HP 4C/T), e utilizamos o "software" Adobe Photoshop 4.0, para a obtençäo dos resultados (D.R e D.Ri). Esses dados serviram para avaliar a soluçäo de processamento radiográfica, quanto a sua atividade, degradaçäo e uso em diferentes temperaturas. A análise dos resultados demonstrou que os processamentos foram mais eficientes nas temperaturas de 31º e 34ºC. Em relaçäo à Densidade Óptica quando comparada à Densidade Radiográfica e Densidade Radiográfica invertida, observamos que estas demonstraram maior equilíbrio e resultados menos discrepantes. A análise estatística dos resultados obtidos pela correlaçäo de Pearson, demonstrou em relaçäo à Densidade Óptica, alta correlaçäo em todas as temperaturas avaliadas e uma correlaçäo ainda maior nas temperaturas de 31ºC e 34ºC quando comparamos com a Densidade Radiográfica e Densidade Radiográfica invertida...


Subject(s)
Absorptiometry, Photon , Absorptiometry, Photon/classification , Absorptiometry, Photon/instrumentation , X-Ray Film/classification , X-Ray Film/standards , Radiography, Dental, Digital/classification , Radiography, Dental, Digital/instrumentation , Radiography, Dental, Digital/methods , Radiographic Image Interpretation, Computer-Assisted , Software Validation , Software/classification
6.
In. Alvares, Luiz Casati; Tavano, Orivaldo. Curso de radiologia em odontologia. Säo Paulo, Santos, 4 ed; 1998. p.17-43, ilus, tab.
Monography in Portuguese | LILACS, BBO | ID: lil-246531
8.
In. Freitas, Aguinaldo de; Rosa, José Edu; Souza, Icléo Faria e. Radiologia odontológica. Säo Paulo, Artes Médicas, 4 ed; 1998. p.3-13, ilus.
Monography in Portuguese | LILACS, BBO | ID: lil-246539
10.
11.
In. Freitas, Aguinaldo de; Rosa, José Edu; Souza, Icléo Faria e. Radiologia odontológica. Säo Paulo, Artes Médicas, 4 ed; 1998. p.167-87, ilus.
Monography in Portuguese | LILACS, BBO | ID: lil-246547
14.
In. Alvares, Sérgio. Endodontia clínica. Säo Paulo, Santos, 2.ed; 1991. p.357-69, ilus.
Monography in Portuguese | LILACS, BBO | ID: lil-250711
15.
Bauru; s.n; 1988. 218 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-222773

ABSTRACT

Para esta pesquisa foi selecionado o filme Ektaspeed (EP-21) processado nas soluçöes Kodak (convencional) e Inodon (monobanho), tendo como meios de avaliaçäo métodos consagrados em radiologia odontológica, tais como densidade óptica, avaliaçäo subjetiva, medidas de pH e cor, utilizando ainda metodologia introduzida recentemente, que é a quantificaçäo de prata metálica na emulsäo radiográfica pela densidade de volume. Os propósitos básicos deste trabalho foram, verificar o tempo de processamento adequado e a atividade química (exaustäo) das soluçöes utilizando a quantidade de 25 ml. O tempo de processamento adequado quando a temperatura era mantida em 22ºC em ambas as soluçöes foi de 4 minutos, embora com tempos de 2 e 3 minutos, obteve-se radiografias com qualidade satisfatória para o diagnóstico. Os resultados de densidade óptica permitiram a representaçäo gráfica através de um traçado característico e serviram para controle e comparaçäo com a densidade de volume de prata, tanto no experimento de processamento, quanto para o teste com fins de verificar a exaustäo destas soluçöes. Com referência à ativiadde química das soluçöes (exaustäo), a soluçäo Kodak foi a que apresentou resultados mais satisfatórios quando comparada à Inodon, provavelmente devido à perda muito rápida da atividade fixadora da soluçäo monobanho. Verificamos que na 45ª radiografia do simulador de mandíbula no processamento Kodak já mostrava sinais indicativos de exaustäo pelo aparecimento de estrias na imagem radiográfica. No processamento da soluçäo Inodon, a partir da 10ª radiografia do simulador percebia-se uma certa dificuldade de fixaçäo da imagem e ainda uma boa atividade de revelaçäo do líquido monobanho. Através da análise microscópica dos filmes radiográficos foram constatadas alteraçöes morfológicas e quantitativas de prata metálica formada em funçäo do tempo de exposiçäo, tempo de processamento e exaustäo das soluçöes empregadas neste estudo...


Subject(s)
Radiography, Dental/methods , X-Ray Film/classification , Diagnosis, Oral/methods , Silver/analysis , Technology, Radiologic/methods
SELECTION OF CITATIONS
SEARCH DETAIL