Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 78
Filter
1.
Int. j. morphol ; 42(3): 554-560, jun. 2024. ilus, tab
Article in English | LILACS | ID: biblio-1564614

ABSTRACT

SUMMARY: The average volumes of normal heart chambers in computed tomography (CT) are used not only as clinical criterions for heart disease diagnosis, but also as references in cardiology. With the development of artificial intelligence (AI), numerous CT data can be analyzed and segmented automatically. This study aimed to determine the average volumes of the four chambers in healthy adult hearts and present surface models with the average volume. Coronary CT angiographs of 508 Korean individuals (330 men and 178 women, 20 - 39 years old) were obtained. An automatic segmentation module for 3D Slicer was developed using machine learning in Anatomage KoreaTM. Using the module, the four chambers and heart valves in the CT were segmented and reconstructed into surface models. Surface models of the four chambers of identical hearts in the CT were produced using SimplewareTM. The volumes of structures were measured using Sim4life Light and statistically analyzed. After determining the average volumes of the four chambers, surface models of the average volumes were constructed. In both software measurements, the atrial volumes of females increased with age, and the ventricular volumes of males decreased significantly with age. The atrial and ventricular volumes of Simpleware were larger and smaller than those of Anatomage, respectively, because of errors in the Simpleware. Regarding the volume measurement, our module developed in this study was more accurate than the Simpleware. The average volume and three-dimensional models used in this study can be used not only for clinical purposes, but also for educational or industrial purposes.


Los volúmenes medios de las cámaras cardíacas normales en la tomografía computarizada (TC) se utilizan no sólo como criterios clínicos para el diagnóstico de enfermedades cardíacas, sino también como referencia en cardiología. Con el desarrollo de la inteligencia artificial (IA), numerosos datos de TC se pueden analizar y segmentar automáticamente. Este estudio tuvo como objetivo determinar los volúmenes promedio de las cuatro cámaras en corazones adultos sanos y presentar modelos de superficie con el volumen promedio. Se obtuvieron angiografías coronarias por TC de 508 individuos coreanos (330 hombres y 178 mujeres, de 20 a 39 años). Se desarrolló un módulo de segmentación automática para 3D Slicer utilizando aprendizaje automático en Anatomage KoreaTM. Utilizando el módulo, las cuatro cámaras y valvas cardíacas de la TC se segmentaron y reconstruyeron en modelos de superficie. Se produjeron modelos de superficie de las cuatro cámaras de corazones idénticos en la TC utilizando SimplewareTM. Los volúmenes de las estructuras se midieron utilizando Sim4life Light y se analizaron estadísticamente. Después de determinar los volúmenes promedio de las cuatro cámaras, se construyeron modelos de superficie de los volúmenes promedio. En ambas mediciones de software, los volúmenes atriales de las mujeres aumentaron con la edad y los volúmenes ventriculares de los hombres disminuyeron significativamente con la edad. Los volúmenes atrial y ventricular de Simpleware eran mayores y menores que los de Anatomage, respectivamente, debido a errores en Simpleware. En cuanto a la medición de volumen, nuestro módulo desarrollado en este estudio fue más preciso que el Simpleware. Los modelos tridimensionales y de volumen medio utilizados en este estudio se pueden utilizar no solo con fines clínicos, sino también con fines educativos o industriales.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Artificial Intelligence , Cardiac Volume , Computed Tomography Angiography , Heart/diagnostic imaging , Imaging, Three-Dimensional
2.
Korean Circulation Journal ; : 146-159, 2019.
Article in English | WPRIM | ID: wpr-738770

ABSTRACT

Cardiac magnetic resonance (CMR) imaging provides accurate anatomic information and advanced soft contrast, making it the reference standard for assessing cardiac volumes and systolic function. In this review, we summarize the recent advances in CMR sequences. New technical development has widened the use of CMR imaging beyond the simple characterization of myocardial scars and assessment of contractility. These novel CMR sequences offer comprehensive assessments of coronary plaque characterization, myocardial fiber orientation, and even metabolic activity, and they can be readily applied in clinical settings. CMR imaging is able to provide new insights into understanding the pathophysiologic process of underlying cardiac disease, and it can help physicians choose the best treatment strategies. Although several limitations, including the high cost and time-consuming process, have limited the widespread clinical use of CMR imaging so far, recent advances in software and hardware technologies have made the future more promising.


Subject(s)
Cardiac Volume , Cardiology , Cicatrix , Heart Diseases , Magnetic Resonance Imaging
4.
Article in English | WPRIM | ID: wpr-716541

ABSTRACT

OBJECTIVE: To investigate changes of cardiac and muscle damage markers in exercise-induced hypertension (EIH) runners before running (pre-race), immediately after completing a 100-km ultramarathon race, and during the recovery period (24, 72, and 120 hours post-race). METHODS: In this observational study, volunteers were divided into EIH group (n=11) whose maximum systolic blood pressure was ≥210 mmHg in graded exercise testing and normal exercise blood pressure response (NEBPR) group (n=11). Their blood samples were collected at pre-race, immediately after race, and at 24, 72, and 120 hours post-race. RESULTS: Creatine kinase (CK) and cardiac troponin I (cTnI) levels were significantly higher in EIH group than those in the NEBPR group immediately after race and at 24 hours post-race (all p < 0.05). However, lactate dehydrogenase (LDH), creatine kinase-myocardial band (CKMB), or CKMB/CK levels did not show any significant differences between the two groups in each period. N-terminal pro-brain natriuretic peptide (NT-proBNP) levels were significantly higher in EIH group than those in NEBPR group immediately after race and at 24 and 72 hours post-race (all p < 0.05). A high sensitivity C-reactive protein (hs-CRP) level was significantly higher in EIH group than that in NEBPR group at 24 hours post-race (p < 0.05). CONCLUSION: The phenomenon of higher inflammatory and cardiac marker levels in EIH group may exaggerate cardiac volume pressure and blood flow restrictions which in turn can result in cardiac muscle damage. Further prospective studies are needed to investigate the chronic effect of such phenomenon on the cardiovascular system in EIH runners.


Subject(s)
Humans , Biomarkers , Blood Pressure , C-Reactive Protein , Cardiac Volume , Cardiovascular System , Racial Groups , Creatine , Creatine Kinase , Exercise Test , Hypertension , L-Lactate Dehydrogenase , Myocardium , Observational Study , Prospective Studies , Running , Troponin I , Volunteers
5.
Arq. bras. cardiol ; 108(3): 246-254, Mar. 2017. tab, graf
Article in English | LILACS | ID: biblio-838703

ABSTRACT

Abstract Background: Prognostic factors are extensively studied in heart failure; however, their role in severe Chagasic heart failure have not been established. Objectives: To identify the association of clinical and laboratory factors with the prognosis of severe Chagasic heart failure, as well as the association of these factors with mortality and survival in a 7.5-year follow-up. Methods: 60 patients with severe Chagasic heart failure were evaluated regarding the following variables: age, blood pressure, ejection fraction, serum sodium, creatinine, 6-minute walk test, non-sustained ventricular tachycardia, QRS width, indexed left atrial volume, and functional class. Results: 53 (88.3%) patients died during follow-up, and 7 (11.7%) remained alive. Cumulative overall survival probability was approximately 11%. Non-sustained ventricular tachycardia (HR = 2.11; 95% CI: 1.04 - 4.31; p<0.05) and indexed left atrial volume ≥ 72 mL/m2 (HR = 3.51; 95% CI: 1.63 - 7.52; p<0.05) were the only variables that remained as independent predictors of mortality. Conclusions: The presence of non-sustained ventricular tachycardia on Holter and indexed left atrial volume > 72 mL/m2 are independent predictors of mortality in severe Chagasic heart failure, with cumulative survival probability of only 11% in 7.5 years.


Resumo Fundamento: Fatores prognósticos são bastante estudados na insuficiência cardíaca (IC), mas ainda não possuem um papel estabelecido na IC grave de etiologia chagásica. Objetivo: Identificar a associação de fatores clínicos e laboratoriais com o prognóstico da IC grave de etiologia chagásica, bem como a associação desses fatores com a taxa de mortalidade e a sobrevida em um seguimento de 7,5 anos. Métodos: 60 pacientes portadores de IC grave de etiologia chagásica foram avaliados com relação às seguintes variáveis: idade, pressão arterial, fração de ejeção, sódio plasmático, creatinina, teste de caminhada de 6 minutos, taquicardia ventricular não sustentada, largura do QRS, volume do átrio esquerdo indexado e classe funcional. Resultados: 53 (88,3%) pacientes foram a óbito durante o período de seguimento e 7 (11,7%) permaneceram vivos. A probabilidade de sobrevida geral acumulada foi de aproximadamente 11%. Taquicardia ventricular não sustentada (HR = 2,11; IC 95%: 1,04 - 4,31; p<0,05) e volume do átrio esquerdo indexado ≥ 72 ml/m2 (HR = 3,51; IC 95%: 1,63 - 7,52; p<0,05) foram as únicas variáveis que permaneceram como preditores independentes de mortalidade. Conclusão: A presença de taquicardia ventricular não sustentada ao Holter e o volume do átrio esquerdo indexado > 72 ml/m2 são preditores independentes de mortalidade na IC chagásica grave, com probabilidade de sobrevida acumulada de apenas 11% em 7,5 anos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Chagas Cardiomyopathy/complications , Chagas Cardiomyopathy/mortality , Heart Failure/etiology , Heart Failure/mortality , Prognosis , Sodium/blood , Stroke Volume/physiology , Time Factors , Blood Pressure/physiology , Cardiac Volume/physiology , Chagas Cardiomyopathy/physiopathology , Epidemiologic Methods , Atrial Function, Left/physiology , Age Factors , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/mortality , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/mortality , Creatinine/blood , Walk Test , Heart Failure/physiopathology
6.
Arq. bras. cardiol ; 105(1): 65-70, July 2015. tab, ilus
Article in English | LILACS | ID: lil-754999

ABSTRACT

Background:

Left atrial volume (LAV) is a predictor of prognosis in patients with heart failure.

Objective:

We aimed to evaluate the determinants of LAV in patients with dilated cardiomyopathy (DCM).

Methods:

Ninety patients with DCM and left ventricular (LV) ejection fraction ≤ 0.50 were included. LAV was measured with real-time three-dimensional echocardiography (eco3D). The variables evaluated were heart rate, systolic blood pressure, LV end-diastolic volume and end-systolic volume and ejection fraction (eco3D), mitral inflow E wave, tissue Doppler e´ wave, E/e´ ratio, intraventricular dyssynchrony, 3D dyssynchrony index and mitral regurgitation vena contracta. Pearson´s coefficient was used to identify the correlation of the LAV with the assessed variables. A multiple linear regression model was developed that included LAV as the dependent variable and the variables correlated with it as the predictive variables.

Results:

Mean age was 52 ± 11 years-old, LV ejection fraction: 31.5 ± 8.0% (16-50%) and LAV: 39.2±15.7 ml/m2. The variables that correlated with the LAV were LV end-diastolic volume (r = 0.38; p < 0.01), LV end-systolic volume (r = 0.43; p < 0.001), LV ejection fraction (r = -0.36; p < 0.01), E wave (r = 0.50; p < 0.01), E/e´ ratio (r = 0.51; p < 0.01) and mitral regurgitation (r = 0.53; p < 0.01). A multivariate analysis identified the E/e´ ratio (p = 0.02) and mitral regurgitation (p = 0.02) as the only independent variables associated with LAV increase.

Conclusion:

The LAV is independently determined by LV filling pressures (E/e´ ratio) and mitral regurgitation in DCM.

.

Fundamento:

O Volume do Átrio Esquerdo (VAE) é preditor prognóstico em pacientes com insuficiência cardíaca.

Objetivo:

O objetivo do estudo foi avaliar os determinantes do VAE em pacientes com Cardiomiopatia Dilatada (CMD).

Métodos:

Incluídos 90 pacientes com CMD e fração de ejeção do Ventrículo Esquerdo (VE) ≤ 0,50. O VAE foi medido pela ecocardiografia tridimensional (eco3D). Foram avaliados frequência cardíaca, pressão arterial sistólica, volume diastólico e sistólico final do VE, fração de ejeção do VE, onda E mitral, onda e´ do anel mitral (Doppler tecidual), relação E/e´, dissincronia intraventricular, índice de dissincronia tridimensional e insuficiência mitral. O coeficiente de correlação de Pearson analisou a correlação do VAE com as variáveis avaliadas e a regressão linear múltipla as variáveis independentes associadas ao VAE.

Resultados:

A idade média foi 53 ± 11 anos, fração de ejeção do VE: 31,5 ± 8,0% e VAE: 39,2 ± 15,7 ml/m2. As variáveis que se correlacionaram com o VAE foram: volume diastólico final do VE (r = 0,38; p < 0,01), volume sistólico final do VE (r = 0,43; p < 0,001), fração de ejeção do VE (r = -0,36; p v 0,01), onda E (r = 0,50; p < 0,01), relação E/e´ (r = 0,51; p < 0,01) e insuficiência mitral (r = 0,53; p < 0,01). A análise multivariada identificou relação E/e´ (p = 0,02) e insuficiência mitral (p = 0,02) como os únicos preditores independentes do aumento do VAE.

Conclusão:

O VAE na CMD é determinado independentemente pelas pressões de enchimento do VE (relação E/e´) e insuficiência mitral.

.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Atrial Function, Left/physiology , Cardiac Volume/physiology , Cardiomyopathy, Dilated/physiopathology , Cardiomyopathy, Dilated , Blood Pressure/physiology , Echocardiography, Doppler , Echocardiography, Three-Dimensional , Heart Atria/physiopathology , Heart Atria , Predictive Value of Tests , Prognosis , Statistics, Nonparametric , Stroke Volume/physiology , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left
8.
Rev. méd. Chile ; 143(4): 415-423, abr. 2015. ilus, tab
Article in Spanish | LILACS | ID: lil-747546

ABSTRACT

Background: Intracoronary delivery of autologous bone marrow mononuclear cells is an interesting therapeutic promise for patients with heart failure of different etiologies. Aim: To evaluate the long-term safety and efficacy of this therapy in patients with dilated cardiomyopathy of different etiologies under optimal medical treatment. Patients and Methods: Prospective, open-label, controlled clinical trial. Of 23 consecutive patients, 12 were assigned to autologous bone marrow mononuclear cell intracoronary transplantation, receiving a mean dose of 8.19 ± 4.43 x 10(6) CD34+ cells. Mortality, cardiovascular readmissions and cancer incidence rate, changes in functional capacity, quality of life questionnaires and echocardiographic measures from baseline, were assessed at long-term follow-up (37.7 ± 9.7 months) in patients receiving or not the cells. Results: No significant differences were observed in mortality, cardiovascular readmissions or cancer incidence rate amongst groups. An improvement in functional class and quality of life questionnaires in the transplanted group was observed (p < 0.01). The treated group showed a non-significant increase in left ventricular ejection fraction at long-term follow-up (from 26.75 ± 4.85% to 34.90 ± 8.57%, p = 0.059 compared to baseline). There were no changes in left ventricular volumes. We observed no improvement of these variables in the control group. Conclusions: Intracoronary transplantation of autologous bone marrow mononuclear cells is feasible and safe in patients with dilated cardiomyopathy of diverse etiologies. This therapy was associated to persistent improvements in functional class and quality of life. There was also a non-significant long-term improvement of left ventricular function.


Subject(s)
Female , Humans , Male , Middle Aged , Bone Marrow Transplantation/methods , Cardiomyopathy, Dilated/surgery , Bone Marrow Transplantation/mortality , Cardiac Volume/physiology , Cardiomyopathy, Dilated/mortality , Cardiomyopathy, Dilated , Follow-Up Studies , Patient Readmission/statistics & numerical data , Prospective Studies , Quality of Life , Stroke Volume/physiology , Surveys and Questionnaires , Time Factors , Transplantation, Autologous , Treatment Outcome , Ventricular Function/physiology
9.
Arq. bras. cardiol ; 103(4): 282-291, 10/2014. tab, graf
Article in English | LILACS | ID: lil-725319

ABSTRACT

Background: According to some international studies, patients with acute coronary syndrome (ACS) and increased left atrial volume index (LAVI) have worse long-term prognosis. However, national Brazilian studies confirming this prediction are still lacking. Objective: To evaluate LAVI as a predictor of major cardiovascular events (MCE) in patients with ACS during a 365-day follow-up. Methods: Prospective cohort of 171 patients diagnosed with ACS whose LAVI was calculated within 48 hours after hospital admission. According to LAVI, two groups were categorized: normal LAVI (≤ 32 mL/m2) and increased LAVI (> 32 mL/m2). Both groups were compared regarding clinical and echocardiographic characteristics, in- and out-of-hospital outcomes, and occurrence of ECM in up to 365 days. Results: Increased LAVI was observed in 78 patients (45%), and was associated with older age, higher body mass index, hypertension, history of myocardial infarction and previous angioplasty, and lower creatinine clearance and ejection fraction. During hospitalization, acute pulmonary edema was more frequent in patients with increased LAVI (14.1% vs. 4.3%, p = 0.024). After discharge, the occurrence of combined outcome for MCE was higher (p = 0.001) in the group with increased LAVI (26%) as compared to the normal LAVI group (7%) [RR (95% CI) = 3.46 (1.54-7.73) vs. 0.80 (0.69-0.92)]. After Cox regression, increased LAVI increased the probability of MCE (HR = 3.08, 95% CI = 1.28-7.40, p = 0.012). Conclusion: Increased LAVI is an important predictor of MCE in a one-year follow-up. .


Fundamento: Portadores de síndrome coronária aguda (SCA) com aumento do índice de volume atrial esquerdo (IVAE) apresentam pior prognóstico em longo prazo segundo alguns estudos internacionais. Todavia, há carência de estudos nacionais ratificando esta predição. Objetivo: Avaliar o IVAE como preditor de evento cardiovascular maior (ECM) em seguimento tardio de pacientes com SCA. Métodos: Coorte prospectiva de 171 pacientes com diagnóstico de SCA e com IVAE calculado dentro de 48 horas após evento índice. Portadores de IVAE normal (≤ 32 ml/m2) e de IVAE aumentado (> 32 ml/m2) foram comparados quanto às características clínicas e ecocardiográficas, evolução intra e extra-hospitalar e ocorrência, em até 365 dias, de ECM. Resultados: Um total de 78 pacientes (45%) apresentaram IVAE > 32 ml/m2. Ocorreu associação entre IVAE aumentado e maior idade, índice de massa corpórea, hipertensão arterial, história de infarto agudo do miocárdio e angioplastia prévia, assim como menor clearance de creatinina e fração de ejeção. Na evolução hospitalar, o edema agudo de pulmão foi mais frequente em pacientes com IVAE aumentado (14,1% vs. 4,3%, p = 0,024). Após a alta hospitalar, a ocorrência do desfecho composto para ECM foi significativamente superior (p = 0,001) no grupo com IVAE aumentado (26%) quando comparado ao grupo de IVAE normal (7%) [RR (IC 95%) = 3,46 (1,54-7,73) vs. 0,80 (0,69-0,92)]. Na regressão de Cox, IVAE aumentado elevou a probabilidade de ECM (HR = 3,08; IC 95% = 1,28-7,40; p = 0,012). Conclusão: O aumento do IVAE é importante preditor de ECM em um ano de seguimento. .


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Acute Coronary Syndrome/physiopathology , Atrial Function, Left/physiology , Cardiac Volume/physiology , Acute Coronary Syndrome/mortality , Acute Coronary Syndrome/therapy , Echocardiography , Follow-Up Studies , Heart Atria/physiopathology , Kaplan-Meier Estimate , Prognosis , Prospective Studies , Registries , Risk Assessment , Risk Factors , Statistics, Nonparametric , Time Factors , Treatment Outcome , Ventricular Dysfunction, Left/physiopathology
10.
Rev. bras. cir. cardiovasc ; 29(3): 426-431, Jul-Sep/2014. tab, graf
Article in English | LILACS | ID: lil-727156

ABSTRACT

Congenital heart disease is the most common fetal congenital malformations; however, the prenatal rate detection still is low. The two-dimensional echocardiography is the "gold standard" exam to screening and diagnosis of congenital heart disease during the prenatal; however, this exam is operator-depending and it is realized only in high risk pregnancies. Spatio-temporal image correlation is a three-dimensional ultrasound software that analyses the fetal heart and your connections in the multiplanar and rendering modes; however, spatio-temporal image correlation too is operator-depending and time-consuming. We presenting a new three-dimensional software named Sonocubic fine to the screening of congenital heart disease. This software applies intelligent navigation technology to spatio-temporal image correlation volume datasets to automatically generate nine fetal echocardiography standard views. Thus, this new software tends to be less operator-depending and time-consuming.


Doenças cardíacas congênitas são as malformações congênitas mais frequentes, entretanto, a detecção pré-natal ainda permanece baixa. A ecocardiografia bidimensional é o "padrão-ouro" para o rastreamento e diagnóstico das doenças cardíacas congênitas durante o pré-natal, entretanto, é operador dependente e realizada somente em gestantes de alto risco. Spatio-temporal image correlation é um software de ultrassonografia tridimensional que analisa o coração fetal e suas conexões vasculares nos modos multiplanar e superfície, contudo, também é operador dependente e consome muito tempo. Apresentamos um novo software: Sonocubic fine para o rastreamento das doenças cardíacas congênitas. Este software aplica a inteligência da tecnologia de navegação em volumes de spatio-temporal image correlation para automaticamente gerar nove planos ecocardiográficos padrões. Além disso, esta técnica tende a ser menos operador dependente e consumir menor tempo.


Subject(s)
Female , Humans , Pregnancy , Echocardiography, Three-Dimensional/methods , Fetal Heart , Heart Defects, Congenital , Imaging, Three-Dimensional/methods , Software/standards , Ultrasonography, Prenatal/methods , Cardiac Volume , Echocardiography, Three-Dimensional/standards , Imaging, Three-Dimensional/standards , Mass Screening , Reproducibility of Results , Ultrasonography, Prenatal/standards
SELECTION OF CITATIONS
SEARCH DETAIL