Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 92
Filter
1.
Rev. bras. oftalmol ; 83: e0042, 2024. tab, graf
Article in English | LILACS | ID: biblio-1569748

ABSTRACT

ABSTRACT Objective: To evaluate the long-term safety and efficacy of repeated corneal cross-linking in eyes of children and adolescents with progressive keratoconus. Methods: This retrospective study included nine eyes of nine consecutive patients with progressive keratoconus who underwent repeated corneal cross-linking 3.9 (range of 1.6 to 5.6) years after a primary one. All patients were followed for a mean period of 9.11 (range of 6 to 11) years after first treatment and 5.44 (range of 4 to 9) years, after corneal cross-linking retreatment. Results: Nine eyes of nine patients (six male) with progressive keratoconus underwent primary corneal cross-linking from 2009 to 2011. Despite the stability achieved with the epi-off corneal cross-linking, keratoconus continued to progress after some time. Mean time to documented evidence of keratoconus progression after primary corneal cross-linking was 3.9 (range of 1.6 to 5.6) years. All eyes were retreated as soon as progression was noted. At the last follow-up visit, 5.44 (range of 4 to 9) years after repeated corneal cross-linking, there was a significant decrease of 2.02 D in mean maximum topographic K-value (p = 0.045) and 1.95D in mean topographic K-value (p = 0.007). Conclusion: Repeated corneal cross-linking seems to be a safe and effective procedure to halt keratoconus progression after a primary corneal cross-linking failure.


RESUMO Objetivo: Avaliar a segurança e a eficácia a longo prazo da repetição do cross-linking corneano em olhos de crianças e adolescentes com ceratocone progressivo. Métodos: Estudo retrospectivo que incluiu nove olhos de nove pacientes consecutivos com ceratocone progressivo, que foram submetidos a retratamento com cross-linking corneano de 3,9 (variação de 1,6 a 5,6) anos após tratamento primário com cross-linking corneano. Todos os pacientes foram acompanhados por um período médio de 9,11 (variação de 6 a 11) anos após o primeiro tratamento e 5,44 (variação de 4 a 9) anos após retratamento com cross-linking corneano. Resultados: Nove olhos de nove pacientes (seis homens) com progressão do ceratocone foram submetidos a cross-linking corneano primário de 2009 a 2011. Apesar da estabilidade alcançada com o epi-off cross-linking corneano, o ceratocone continuou a progredir após algum tempo. O tempo médio para evidência documentada de progressão do ceratocone após cross-linking corneano primário foi de 3,9 (intervalo de 1,6 a 5,6) anos. Todos os olhos foram retratados com cross-linking corneano, assim que a progressão foi observada. Na última consulta de acompanhamento, 5,44 (variação de 4 a 9) anos após a repetição do cross-linking corneano, houve diminuição significativa de 2,02 D na média da curvatura máxima (p = 0,045) e 1,95 D na média da curvatura média (p = 0,007). Conclusão: O retratamento com cross-linking corneano parece ser um procedimento seguro e eficaz para interromper a progressão do ceratocone após falha primária do cross-linking corneano.


Subject(s)
Humans , Male , Female , Child , Adolescent , Corneal Cross-Linking/methods , Keratoconus/drug therapy , Riboflavin/therapeutic use , Ultraviolet Rays , Retrospective Studies , Follow-Up Studies , Photosensitizing Agents/therapeutic use , Retreatment , Cross-Linking Reagents/therapeutic use , Corneal Pachymetry , Keratoconus/diagnosis
2.
Rev. bras. oftalmol ; 83: e0040, 2024. tab, graf
Article in English | LILACS | ID: biblio-1569741

ABSTRACT

ABSTRACT Objective: To verify whether there are pathological dysfunctions in the cornea of patients with endometriosis. Methods: Case-control research with a quantitative approach that compared topographic and tomographic examinations of the cornea of patients with a laparoscopic diagnosis of endometriosis, without the use of hormonal medications, to the control group. Results: We analyzed 78 eyes, 34 from the endometriosis group and 44 from the control group. The loss of orthogonality between the axes of the corneal curvatures was more frequent in the group with endometriosis (p = 0.0744). The difference between the mean keratometric measurements of the two eyes was significantly greater in the control group (p = 0.0204). In the tomographic findings, the group with endometriosis presented higher means of posterior elevation compared to the control group (p = 0.0060). Conclusion: The results do not allow us to conclude that women with endometriosis have a higher risk of developing corneal ectasia, although the posterior elevation map demonstrated a greater posterior curvature of the cornea in this group, with a statistically significant difference. However, an isolated increase in the posterior elevation map does not have good diagnostic accuracy.


RESUMO Objetivo: Verificar se há disfunções patológicas na córnea de pacientes portadoras de endometriose. Métodos: Pesquisa do tipo caso-controle de abordagem quantitativa, que comparou exames topográficos e tomográficos da córnea de pacientes com diagnóstico laparoscópico de endometriose, sem uso de medicações hormonais, ao grupo controle. Resultados: Foram analisados 78 olhos, 34 do grupo com endometriose e 44 do grupo controle. A perda da ortogonalidade entre os eixos das curvaturas corneanas foi mais frequente no grupo com endometriose (p = 0,0744). A diferença entre as médias das medidas ceratométricas dos dois olhos foi significativamente maior no grupo controle (p = 0,0204). Nos achados tomográficos, o grupo com endometriose apresentou maiores médias de elevação posterior em relação ao controle (p = 0,0060). Conclusão: Os resultados não permitem concluir que portadoras de endometriose têm maior risco de desenvolver ectasia corneana, embora o mapa de elevação posterior tenha demonstrado maior curvatura posterior da córnea nesse grupo, com diferença estatisticamente significativa. Contudo, um aumento isolado no mapa de elevação posterior não possui boa acurácia diagnóstica.


Subject(s)
Humans , Female , Adult , Middle Aged , Cornea/pathology , Corneal Topography/methods , Endometriosis , Case-Control Studies , Estrogens , Corneal Pachymetry
3.
Rev. bras. oftalmol ; 82: e0037, 2023. tab
Article in Portuguese | LILACS | ID: biblio-1449771

ABSTRACT

RESUMO Objetivo Identificar alterações de aberrometria de alta ordem em diferentes graus de ceratocone. Métodos Estudo transversal, retrospectivo, observacional. Foram analisados 54 pacientes (108 olhos) diagnosticados com ceratocone pelo mesmo especialista em córnea por meio dos critérios ABCD de Belin/Ambrósio Enhanced Ectasia, utilizando-se o tomógrafo Pentacam® HR 70900 (Oculus Wetzlar, Alemanha). Além disso, foram feitas análises qualitativa e quantitativa das aberrações de alta ordem desses mesmos pacientes por meio do OPD-Scan III-NIDEK. Resultados Por meio da avaliação de ambos os olhos dos pacientes com os critérios de Belin-Ambrósio, constatou-se presença de ceratocone em 34 pacientes. Ademais, por meio da análise estatística, constatou-se relação direta entre a asfericidade posterior e o desenvolvimento do ceratocone, com p<0,001 (referência: p<0,05). Por meio da análise do OPD-Scan III-NIDEK, as principais aberrações de alta ordem encontradas nos pacientes com ceratocone foram coma, trefoil e aberração esférica. Conclusão O raio da curvatura posterior é a primeira variável a se alterar com o desenvolvimento do ceratocone, o que se faz perceptível na análise da asfericidade posterior por meio o Pentacam®. Além disso, a alteração da paquimetria e da asfericidade posterior influencia diretamente o desenvolvimento de aberrações de alta ordem em pacientes com ceratocone.


ABSTRACT Objective To identify higher order aberrometry changes in different degrees of keratoconus. Methods Cross-sectional, retrospective, observational study. Fifty-four patients (108 eyes) diagnosed with keratoconus by the same corneal specialist using the Belin/Ambrósio Enhanced Ectasia ABCD criteria were analyzed, using the Pentacam® HR 70900 tomograph (Oculus Wetzlar, Germany). In addition, qualitative and quantitative analysis of higher order aberrations in these patients was performed using the OPD-Scan III-NIDEK. Results Through the evaluation of both eyes of the patients according to the criteria of Benin Ambrósio, the presence of KCN was verified in 34 patients. Furthermore, through statistical analysis, a direct relationship was found between posterior asphericity and the development of KCN; p<0.001 (reference: p<0.05). Through the analysis of the OPD scan, the main higher order aberrations found in patients with KCN were Coma, Trefoil and Spherical Aberration (AE). Conclusion The posterior curvature radius is the first variable to change with the development of the KCN, which is noticeable in the analysis of posterior asphericity in Pentacam. In addition, alterations in pachymetry and posterior asphericity directly influence the development of higher order aberrations in patients with KCN.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aberrometry/methods , Keratoconus/diagnosis , Visual Acuity , Medical Records , Cross-Sectional Studies , Retrospective Studies , Dilatation, Pathologic , Corneal Pachymetry , Observational Study
4.
Rev. bras. oftalmol ; 82: e0016, 2023. graf
Article in Portuguese | LILACS | ID: biblio-1431669

ABSTRACT

RESUMO Objetivo: Analisar retrospectivamente as alterações na ceratometria e no astigmatismo corneano obtidas após cirurgia de implante de anel intraestromal, comparando o uso de um segmento de arco longo versus o implante de dois segmentos de comprimento de arco tradicional. Métodos: A partir de um estudo transversal, obtivemos os dados de 94 olhos de pacientes diagnosticados com ceratocone, que foram submetidos ao implante de anel corneano. Eles foram divididos em dois grupos, dependendo do tipo de implante recebido: Grupo A, um segmento de arco longo; Grupo B, dois segmentos tradicionais. Todos os segmentos implantados possuíam 250µ de espessura. Os dados do pré-operatório dos dois grupos foram comparados, para garantir que as amostras eram similares (as diferenças encontradas entre os dois grupos não eram estatisticamente significativas). As variáveis analisadas no pré e no pós-operatório foram acuidade visual com correção, ceratometria, astigmatismo corneano e refração. Resultados: A amostra que recebeu apenas um segmento de arco longo (Grupo A) obteve redução da ceratometria média de 4,42D (8,7%) e do astigmatismo corneano de 2,43D (40,4%). Já na amostra dos olhos que receberam dois segmentos de arco tradicional (Grupo B), houve redução média de 2,66D (5,1%) em relação à ceratometria média e redução média de 2,11D (34,8%) em relação ao astigmatismo corneano. A redução obtida na ceratometria média no Grupo A foi maior que a obtida no Grupo B (diferença estatisticamente significativa). A redução obtida no astigmatismo do Grupo A não foi estatisticamente significante, se comparada com o resultado obtido no Grupo B (considerando p≤0,05). Conclusão: Foi demonstrado que o uso de um segmento de arco longo possui maior capacidade de aplanação corneana, se comparado com o uso de dois segmentos com comprimento de arco tradicional. Em relação à redução do astigmatismo, os dois grupos mostraram resultados equivalentes.


ABSTRACT Purpose: To retrospectively analyze the changes in corneal keratometry and astigmatism after intrastromal ring surgery, comparing the use of one long arch segment versus two traditional arc length segments. Methods: A cross-sectional study obtained data from 94 eyes of patients diagnosed with keratoconus that underwent surgical treatment with corneal ring implant. They were divided into two groups according to the type of implant received: one long-arch segment (Group A) or two traditional segments (Group B), both 250 microns thick. Preoperative data from the two groups were compared to ensure that the samples were similar (the differences between the two groups were not statistically significant). The variables (pre and post-operatively) analyzed were: best corrected visual acuity, keratometry, corneal astigmatism and refraction. Results: Group A, which received one long arch segment, showed a Km decrease of 4.42D (8.7%) and a corneal astigmatism reduction of 2.43D (40.4%). Group B, where the eyes acquired two traditional arch segments, showed an average Km decrease of 2.66D (5.1%) and corneal astigmatism reduction of 2.11D (34.8%). The mean keratometry (Km) reduction obtained was statistically significant (p≤0.05) when comparing both groups (A and B). The mean corneal astigmatism reduction was not statistically significant (p≤0.05) when comparing both groups (A and B). Conclusions: One long-arch segment has been demonstrated to have a greater capacity to reduce corneal curvature when compared to the use of two traditional-sized arch segments. No significant differences were found regarding the reduction of corneal astigmatism after comparing the results obtained in both groups.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Prostheses and Implants , Corneal Stroma/surgery , Prosthesis Implantation/methods , Keratoconus/surgery , Refraction, Ocular , Astigmatism , Visual Acuity , Cross-Sectional Studies , Treatment Outcome , Corneal Topography , Corneal Pachymetry
5.
Rev. bras. oftalmol ; 81: e0058, 2022. tab
Article in English | LILACS | ID: biblio-1394861

ABSTRACT

ABSTRACT Objective To analyze and describe the coefficients found on maximum Ambrósio Relational Thickness-Maximum (ART-Max) and Belin/Ambrósio Enhanced Ectasia Display total deviation (BAD-D) in eyes with normal corneal topography subjected to cataract surgery with premium intraocular lens implantation and correlated these data with final visual acuity. Methods ART-Max and BAD-D data from 103 eyes of patients subjected to implantation of diffractive bifocal intraocular lens, with normal corneal topography who achieved visual acuity of 20/20 or 20/25 without correction after cataract surgery were analyzed. The groups with normal and abnormal values were compared using the chi-square test. Results Thirty-two (31.1%) and 71 (68.9%) eyes presented normal and abnormal ART-Max values, respectively. The difference between these groups was significant (p=0.0002). Fifty-five (53.4%) and 48 (46.6%) eyes had normal and abnormal BAD-D, respectively, and intergroup difference was not significant (p=0.9576). Conclusion Among patients with normal corneal topography who underwent premium intraocular and had good final visual acuity of 20/20 or 20/25, suspicious or abnormal indices of ART-Max and BAD-D were frequent, providing evidence that it possibly should not be a contraindication.


RESUMO Objetivo Analisar e descrever os coeficientes numéricos encontrados nos exames Ambrósio Relational Thickness-Maximum (ART-Max) e desvio total do Belin/Ambrósio Enhanced Ectasia Display (BAD-D) em olhos com topografia normal submetidos ao implante de lente intraocular premium na cirurgia de catarata, correlacionando-os com a acuidade visual final pós-operatória. Métodos Foram analisados os resultados de ART-Max e BAD-D de 103 olhos de pacientes submetidos ao implante de lentes bifocais difrativas, que apresentavam exame topográficos normal e alcançaram acuidade visual 20/20 ou 20/25 sem correção visual no pós-operatório final. Para a análise estatística entre os grupos normais e anormais ou suspeitos, utilizou-se o teste do qui-quadrado. Resultados Foram encontrados 32 (31,1%) olhos com ART-Max normal e 71 (68,9%) com ART-Max suspeito/anormal. A diferença entre os grupos foi significativa (p=0,0002). Quanto ao BAD-D, foram encontrados 55 (53,4%) olhos com resultados normais e 48 (46,6%) com resultados suspeitos/anormais. A diferença entre os grupos não foi significativa (p=0,9576). Conclusão Entre os pacientes com topografia normal submetidos ao implante de lentes premium e que alcançaram acuidade visual 20/20 ou 20/25, os índices suspeitos ou anormais de ART-Max e BAD-D eram frequentes, não se configurando em contraindicação para a realização do implante.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Refractive Errors/prevention & control , Visual Acuity/physiology , Cornea/pathology , Corneal Diseases/diagnosis , Corneal Topography/methods , Dilatation, Pathologic/diagnosis , Postoperative Complications , Cataract Extraction/adverse effects , Retrospective Studies , ROC Curve , Corneal Diseases/etiology , Lens Implantation, Intraocular/adverse effects , Corneal Pachymetry/methods
6.
Rev. cuba. oftalmol ; 34(3): e973, 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1352020

ABSTRACT

Objetivo: Comparar las mediciones biométricas realizadas con el IOL Master 700 y el Pentacam AXL en pacientes miopes con cirugía fotoablativa previa. Métodos: Se realizó un estudio transversal en 103 ojos de 103 pacientes miopes con cirugía fotoablativa previa, atendidos en el período de enero 2019 a enero 2020, en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer". Las variables estudiadas fueron: edad, sexo, equivalente esférico y características biométricas posoperatorias (longitud axial, profundidad de la cámara anterior y queratometrías), así como su relación, aportadas automáticamente por el IOL master 700 y el pentacam AXL para evitar los factores dependientes del operador, tres meses después de la cirugía. El análisis estadístico se realizó con la prueba t para datos pareados, utilizando una significación del 95 por ciento. Resultados: La edad promedio fue de 25,72 ± 4,26 años. Se analizaron 53 ojos derechos y 50 izquierdos, todos tratados con láser de superficie. El equivalente esférico medio fue de -0,06 ± 0,34 dioptrías y el tiempo entre la cirugía y los exámenes fue de 6,32 ± 3,56 meses. No hubo diferencia estadísticamente significativa (p > 0,05) entre la longitud axial y la profundidad de la cámara anterior; mientras que sí la hubo (p < 0,01) con las queratometrías obtenidas con el IOL Master 700, en comparación con los del pentacam AXL. Conclusión: En pacientes miopes con cirugía fotoablativa previa, el IOL Master 700 y el pentacam AXL proveen mediciones biométricas similares, como la longitud axial y la profundidad de la cámara anterior, no así con la queratometría, la cual es diferente(AU)


Objective: Compare the biometric measurements taken with IOL Master 700 and Pentacam AXL in myopic patients with previous photoablative surgery. Methods: A cross-sectional study was conducted of 103 eyes of 103 myopic patients undergoing photoablative surgery at Ramón Pando Ferrer Cuban Institute of Ophthalmology from January 2019 to January 2020. The variables analyzed were age, sex, spherical equivalent and preoperative biometric characteristics (axial length, anterior chamber depth and keratometries) and the relationship to one another, automatically supplied by IOL Master 700 and Pentacam AXL to avoid operator-dependent factors. The analysis was performed three months after surgery. Statistical analysis was based on the paired Student's t-test with a significance level of 95 percent. Results: Mean age was 25.72 ± 4.26 years. Fifty-three right eyes and 50 left eyes were studied, all of them treated with surface laser. Mean spherical equivalent was -0.06 ± 0.34 diopters; the time elapsed between surgery and the tests was 6.32 ± 3.56 months. No statistically significant differences (p > 0.05) were found between axial length and anterior chamber depth, but statistically significant differences (p < 0.01) were observed between the keratometries obtained with IOL Master 700 and Pentacam AXL. Conclusion: IOL Master 700 and Pentacam AXL provide similar biometric measurements for axial length and anterior chamber depth in myopic patients with previous photoablative surgery, but keratometric measurements are different(AU)


Subject(s)
Humans , Adult , Data Interpretation, Statistical , Corneal Pachymetry/methods , Lasers , Myopia/etiology , Cross-Sectional Studies
7.
Arq. bras. oftalmol ; Arq. bras. oftalmol;84(4): 324-329, July-Aug. 2021. tab, graf
Article in English | LILACS | ID: biblio-1285298

ABSTRACT

ABSTRACT Purpose: Keratoconus presents certain specificities in pediatric patients compared with adults. The greatest challenge is because the disease is typically more severe and progresses faster in children. This retrospective study aimed to report crosslinking procedure in patients under 18 years of age and their follow-up for at least 24 months after the procedure. Methods: Overall, 12 eyes from 10 patients were studied and data, such as visual acuity with and without correction, maximum keratometry, corneal thickness, foveal thickness, and endothelial microscopy, were assessed at both preoperative and postoperative visits. Corneal crosslinking was performed in all patients. Results: A tendency toward reduced Kmax and improved Corrected Distance Visual Acuity at all postoperative moments. Only one of the 12 eyes exhibited increased Kmax of more than 1 D during a time frame longer than 12 months. Regarding pachymetry, a tendency for corneal thinning was observed in the first four months after surgery. Conclusion: Encouraging results were obtained regarding the stabilization of the disease, progression, and procedural safety, corroborating to other authors' findings. The significance of early diagnosis and short-term follow-up were highlighted.


RESUMO Objetivo: O ceratocone na população pediátrica apresenta algumas particularidades em relação à população adulta. O maior desafio é devido à doença ser geralmente mais severa e rapidamente progressiva em crianças. Métodos: Este artigo utiliza uma análise retrospectiva para relatar o uso do crosslinking em jovens menores de 18 anos e sua evolução pelo menos 24 meses após o procedimento. Foram estudados 12 olhos de 10 pacientes, e dados como acuidade visual com e sem correção, ceratometria máxima, espessura corneana, espessura foveal e microscopia endotelial avaliados no pré e pós-operatórios. O crosslinking corneano foi realizado em todos os pacientes pelo mesmo cirurgião. Resultados: Observou-se uma tendência de redução do valor do Kmax e melhora da acuidade visual corrigida em todos os momentos de pós operatório. Com relação à paquimetria, observou-se afinamento corneano do ponto mais fino, nos primeiros quatro meses de pós-operatório. Conclusão: Resultados encorajadores foram obtidos com relação à estabilização da doença, progressão e segurança do procedimento, corroborando com as conclusões de outros autores. A importância do diagnóstico precoce e do acompanhamento a curto prazo do paciente deve ser destacada.


Subject(s)
Adolescent , Adult , Child , Humans , Photochemotherapy , Keratoconus , Riboflavin/therapeutic use , Ultraviolet Rays , Retrospective Studies , Collagen/therapeutic use , Photosensitizing Agents/therapeutic use , Cornea , Corneal Topography , Cross-Linking Reagents/therapeutic use , Corneal Pachymetry , Keratoconus/surgery , Keratoconus/drug therapy
8.
Rev. cuba. oftalmol ; 34(2): e969, 2021. graf
Article in Spanish | LILACS, CUMED | ID: biblio-1341458

ABSTRACT

El ojo humano es un instrumento óptico simple, pero extremadamente robusto. Los sistemas de imágenes para el diagnóstico y evaluación del segmento anterior del ojo constituyen una herramienta fundamental para el oftalmólogo. Hasta hace poco, el uso de estas técnicas proporcionaba fundamentalmente información cualitativa sobre ciertas enfermedades; sin embargo, el desarrollo de nuevas técnicas de cuantificación abre una nueva Era de evaluación y tratamiento basado en imagen. La tomografía de coherencia óptica de segmento anterior se ha convertido en una herramienta crucial en la Oftalmología. El MS-39 es un topógrafo que usa el dominio espectral y la topografía con disco de Plácido para obtener mediciones del segmento anterior del ojo. Brinda información sobre paquimetría, elevación, curvatura y poder dióptrico de ambas caras de la córnea. Además, permite realizar mapas epiteliales y biometría del cristalino. La alta repetibilidad de esta tecnología justifica su uso en la práctica clínica. De ahí la motivación para realizar una búsqueda de diversos artículos publicados, con el objetivo de describir las características y la utilidad del MS-39 para el estudio del segmento anterior del ojo. Se utilizó la plataforma Infomed, específicamente la Biblioteca Virtual de Salud, con todos sus buscadores(AU)


The human eye is a simple but extremely robust optical tool. Imaging systems for the diagnosis and evaluation of the anterior segment of the eye are a fundamental tool for ophthalmologists. Until recently, use of these techniques mainly provided qualitative information about certain diseases; however, the current development of quantification techniques has paved the way for a new era in image-based evaluation and treatment. Optical coherence tomography of the anterior segment has gained crucial importance in ophthalmology. MS-39 is a topograph that uses the spectral domain and Placido disc topography to obtain measurements of the anterior segment of the eye. This tool provides information about the pachymetry, elevation, curvature and dioptric power of both sides of the cornea. It also permits the development of epithelial maps and crystalline lens biometry. The great repeatability of this technology justifies its use in clinical practice. Hence the motivation to conduct a search for a variety of published papers, with the purpose of describing the characteristics and usefulness of the MS-39 for the study of the anterior segment of the eye. Use was made of the Infomed platform, particularly the Virtual Health Library with all its search engines(AU)


Subject(s)
Humans , Topography/methods , Tomography, Optical Coherence/methods , Corneal Pachymetry/methods , Anterior Eye Segment/diagnostic imaging , Review Literature as Topic , Databases, Bibliographic
9.
Rev. bras. oftalmol ; 80(2): 107-110, Mar.-Apr. 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1280108

ABSTRACT

RESUMO Objetivo: Avaliar a contagem endotelial da córnea em pacientes com ceratocone (KCN) por microscopia especular e correlacionar com o estágio do ceratocone. Métodos: Noventa e três olhos de 61 pacientes com KCN foram incluídos neste estudo transversal. Os olhos foram classificados nos estágios 1 a 4 de KCN de acordo com a classificação de Amsler-Krumeich utilizando ceratometria obtida pela topografia de córnea e leituras de paquimetria obtidas pela microscopia especular. Resultados: A idade variou de 12 a 43 anos, média ± (desvio padrão) 22,1 ± 6,7 anos. A ceratometria média variou de 42,25 a 71,4 D (53,0 ± 6,1 D). A paquimetria variou de 350 a 606 µm, (461,7 ± 47,1 µm). Em relação a classificação, 23 pacientes (24,7%) apresentavam estágio 1, 24 (25,8%) estágio 2, 5 (6,5%) estágio 3 e 41 pacientes (44,1%) estágio 4. Não foi observada correlação linear entre ceratometria média e contagem de células endoteliais (Coeficiente de correlação de Pearson = -0,05). Nos estágios iniciais a moderados de KCN, a média da contagem de células endoteliais foi 2738,3 ± 285,4 cel/mm2, enquanto no grupo de KCN avançado (estágios 3 e 4) foi 2670,6 ± 262,7 cel/mm2, p= 0,24. Conclusões: Não há correlação entre a contagem de células endoteliais e o estágio do KCN.


ABSTRACT Objective: To evaluate the corneal endothelial count in patients with keratoconus (KCN) by specular microscopy and correlate with the stage of keratoconus. Methods: Ninety-three eyes from 61 patients with KCN were included in this cross-sectional study. The eyes were classified into KCN stages 1 to 4 according to the Amsler-Krumeich classification using keratometry obtained by corneal topography and pachymetry readings obtained by specular microscopy. Results: Age ranged from 12 to 43 years, mean ± (standard deviation) 22.1 ± 6.7 years. The average keratometry ranged from 42.25 to 71.4 D, (53.0 ± 6.1 D). Pachymetry ranged from 350 to 606 µm, (461.7 ± 47.1 µm). Regarding the Amsler classification, 23 patients (24.7%) had stage 1, 24 (25.8%) stage 2, 5 (6.5%) stage 3 and 41 patients (44.1%) stage 4. No linear correlation was observed between mean keratometry and endothelial cell count (Pearson's correlation coefficient = -0.05). In the early to moderate stages of KCN, the mean endothelial cell count was 2738.3 ± 285.4 cell / mm2, while in the advanced KCN group (stages 3 and 4) it was 2670.6 ± 262.7 cell / mm2 , p = 0.24. Conclusions: No correlation was found between the endothelial cell count and the KCN stage.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Endothelial Cells , Keratoconus/diagnosis , Microscopy , Endothelium, Corneal , Cell Count , Cross-Sectional Studies , Corneal Topography , Corneal Pachymetry
10.
Rev. cuba. oftalmol ; 34(1): e964, 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1289523

ABSTRACT

Objetivo: Comparar las características de la córnea entre individuos chinos y cubanos adultos sanos. Métodos: Se realizó un estudio observacional, descriptivo, transversal, en 120 ojos de individuos sanos (60 chinos y 60 cubanos), entre 18 y 29 años de edad, entre septiembre del año 2016 y diciembre de 2017 en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer". Se evaluó la edad, el sexo, la queratometría, la paquimetría y las características del endotelio corneal. Resultados: Predominó el sexo femenino (53,3 por ciento en los cubanos y 66,6 por ciento en los chinos). La edad promedio fue de 24,4 años en ambos grupos. La queratometría promedio resultó mayor en el grupo de estudio de cubanos, con un valor de 44,7 y 44,6 dioptrías en ambos ojos, respectivamente. El espesor corneal fue de 607,3-629,9 en los cubanos y de 575,4-607,2 en los chinos. El coeficiente de variación, la desviación estándar y la densidad celular se diferenciaron mínimamente en ambos ojos para ambas nacionalidades, y resultaron superiores en los ojos izquierdos con un coeficiente de 32,0 (±11,0) en los chinos. La desviación estándar promedio fue de 112,0 (± 36,5) en ambos grupos y en el ojo derecho la densidad celular fue 2 857,1 (± 240,0 cél/mm2) en los chinos y 2 760,0 (± 367,2) en los cubanos. El average de los cubanos estuvo entre 369,0 y 380, y para los chinos entre 352,4 y 358,4 en los ojos derecho e izquierdo. Conclusiones: Existen diferencias significativas en los valores queratométricos. El espesor corneal resulta discretamente más reducido en los chinos. El coeficiente de variación, la densidad celular, el average y la desviación estándar no presentan diferencias estadísticamente significativas(AU)


Objective: Compare the corneal features of Chinese and Cuban healthy adult subjects. Methods: A cross-sectional observational descriptive study was conducted of 120 eyes of healthy 18-29 year old individuals (60 Chinese and 60 Cuban) from September 2016 to December 2017 at Ramón Pando Ferrer Cuban Institute of Ophthalmology. The variables analyzed were sex, keratometry, pachymetry and characteristics of the corneal endothelium. Results: Female sex prevailed (53.3 percent among Cuban and 66.6 percent among Chinese subjects). Mean age was 24.4 years in both groups. Mean keratometry was higher in the Cuban group, with values of 44.7 and 44.6 diopters for both eyes, respectively. Corneal thickness was 607.3-629.9 among Cuban and 575.4-607.2 among Chinese subjects. Variation coefficient, standard deviation and cell density were minimally different between the two eyes in both groups, and were higher in left eyes of Chinese subjects with a coefficient of 32.0 (±11.0). Mean standard deviation was 112.0 (± 36.5) in both groups, whereas right eye cell density was 2 857.1 (± 240.0 cell/mm2) among Chinese and 2 760.0 (± 367.2) among Cuban subjects. Average between right and left eyes ranged from 369.0 to 380 for the Cubans and from 352.4 to 358.4 for the Chinese. Conclusions: Significant differences were found between keratometric values. Corneal thickness was slightly lower among Chinese subjects. Variation coefficient, cell density, average and standard deviation did not show any statistically significant differences(AU)


Subject(s)
Humans , Male , Female , Adult , Endothelium, Corneal/diagnostic imaging , Cell Count/methods , Corneal Pachymetry/methods , China , Epidemiology, Descriptive , Cross-Sectional Studies , Cuba , Observational Studies as Topic
11.
Rev. bras. oftalmol ; 80(3): e0011, 2021. graf
Article in English | LILACS | ID: biblio-1280118

ABSTRACT

ABSTRACT The authors report the case of a male adult presenting significant ocular complications and irreversible visual impairment, resulting from the long-term progression and late diagnosis of an iris cyst in the right eye, probably secondary to trauma. The patient was admitted to Hospital Universitário Antonio Pedro with a total corneal opacity that blocked direct visualization of the anterior chamber. Ultrasound biomicroscopy was crucial for the anatomic study, and the patient was submitted to enucleation for aesthetic improvement and clarifying diagnosis. We concluded athalamia and deformation of the anterior segment, due to expansion of the cyst, led to gradual elevation of the intraocular pressure and damage of the optic nerve, resulting in visual loss.


RESUMO Relatamos o caso de um paciente com evolução e diagnóstico tardios de cisto de íris no olho direito, provavelmente secundário a trauma, com complicações importantes e baixa irreversível da visão, tendo sido admitido no Hospital Universitário Antônio Pedro já com leucoma total da córnea e câmara anterior indevassável. A biomicroscopia ultrassônica se mostrou imprescindível para o estudo anatômico, sendo o paciente finalmente submetido à enucleação, para melhora estética e elucidação diagnóstica. Concluímos que a atalamia e a desestruturação do segmento anterior, consequentes ao crescimento cístico, levaram a um gradativo aumento da pressão intraocular e lesão do nervo óptico, com consequente perda da visão.


Subject(s)
Humans , Male , Middle Aged , Cysts/complications , Cysts/diagnosis , Iris Diseases/diagnosis , Ophthalmoscopy , Tonometry, Ocular/methods , Magnetic Resonance Imaging , Eye Enucleation , Visual Acuity , Iris/diagnostic imaging , Ocular Hypertension/diagnosis , Ocular Hypertension/etiology , Blindness/etiology , Corneal Topography , Cysts/surgery , Cysts/pathology , Corneal Pachymetry , Slit Lamp Microscopy/methods , Iris Diseases/surgery , Iris Diseases/complications , Iris Diseases/pathology
12.
Arq. bras. oftalmol ; Arq. bras. oftalmol;83(3): 225-228, May-June 2020. tab
Article in English | LILACS | ID: biblio-1131584

ABSTRACT

ABSTRACT Purpose: A significant transient increase in intraocular pressure in individuals wearing swimming goggles has been demonstrated in previous studies. These findings suggested that wearing swimming goggles could represent a significant risk factor for worsening of corneal parameters in patients with keratoconus who swim regularly. The aim of this study was to investigate corneal parameters in patients with keratoconus after wearing swimming goggles. Methods: Comprehensive ocular examinations were performed on 74 eyes of 37 patients with keratoconus. Measurements of the corneal front keratometry values (Kflat, Ksteep, and Kmax), central corneal thickness, corneal apex thickness, thinnest corneal thickness, corneal volume, anterior chamber volume, anterior chamber depth, and iridocorneal angle were performed in outpatient clinics using a Pentacam® Scheimpflug camera (Oculus, Wetzlar, Germany) before the patients wore swimming goggles and after they wore swimming goggles for 1, 10, and 20 min. A p-value of <0.05 was regarded as statistically significant. Results: The average values before and after wearing swimming goggles for 1, 10, and 20 min were 52.72 ± 5.36, 52.64 ± 5.52, 52.62 ± 5.38, and 52.22 ± 4.86, respectively (p=0.257). The average values before and after wearing swimming goggles for 1, 10, and 20 min were 46.01 ± 3.17, 46.09 ± 3.17, 46.06 ± 3.26, and 46.04 ± 3.17, respectively (p=0.426). The average values before and after wearing swimming goggles for 1, 10, and 20 min were 49.02 ± 3.56, 49.06 ± 3.61, 49.08 ± 3.62, and 49.07 ± 3.61, respectively (p=0.750). No other corneal parameters showed changes after wearing swimming goggles (p>0.05). However, the anterior chamber volume markedly decreased after wearing swimming goggles (p<0.001). Conclusions: These findings suggested that the short-term use of swimming goggles does not increase the risk of corneal parameter worsening in patients with keratoconus.


RESUMO Objetivo: Um aumento transitório significativo da pressão intraocular em indivíduos usando óculos de natação foi demonstrado em estudos anteriores. Esses achados sugerem que o uso de óculos de natação pode representar um fator de risco significativo para o agravamento dos parâmetros corneanos em pacientes com ceratocone que nadam regularmente. O objetivo deste estudo foi investigar os parâmetros corneanos em pacientes com ceratocone após o uso de óculos de natação. Métodos: Foram realizados exames oftalmológicos completos em 74 olhos de 37 pacientes com ceratocone. As medidas dos valores de ceratometria frontal da córnea (Kflat, Ksteep e Kmax), espessura corneana central, espessura apical da córnea, espessura corneana mais fina, volume da córnea, volume da câmara anterior, profundidade da câmara anterior e ângulo iridocorneano foram realizados em ambulatórios usando câmera Pentacam® Scheimpflug (Oculus, Wetzlar, Alemanha) antes dos pacientes usarem óculos de natação por 1, 10 e 20 min. Um valor p<0,05 foi considerado estatisticamente significativo. Resultados: Os valores médios de antes e após o uso de óculos de natação por 1, 10 e 20 min foram: 52,72 ± 5,36, 52,64 ± 5,52, 52,62 ± 5,38 e 52,22 ± 4,86, respectivamente (p=0,257). Os valores médios do (antes e após o uso de óculos de natação por 1, 10 e 20 min foram: 46,01 ± 3,17, 46,09 ± 3,17, 46,06 ± 3,26 e 46,04 ± 3,17, respectivamente (p=0,426). Os valores médios de antes e após o uso de óculos de natação por 1, 10 e 20 min foram: 49,02 ± 3,56, 49,06 ± 3,61, 49,08 ± 3,62 e 49,07 ± 3,61, respectivamente (p=0,750). Nenhum outro parâmetro da córnea apresentou alterações após o uso de óculos de natação (p>0,05). No entanto, o volume da câmara anterior diminuiu acentuadamente após o uso de óculos de natação (p<0,001). Conclusões: Esses achados sugerem que o uso de óculos de natação a curto prazo não aumenta o risco de piora dos parâmetros corneanos em pacientes com ceratocone.


Subject(s)
Humans , Cornea , Corneal Topography , Eye Protective Devices , Corneal Pachymetry , Keratoconus , Swimming , Tonometry, Ocular
13.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(6): 507-510, Nov.-Dec. 2019. tab
Article in English | LILACS | ID: biblio-1038689

ABSTRACT

ABSTRACT Purpose: The aim of this study was to evaluate anterior segment parameters and corneal aberrations in patients with retinitis pigmentosa using Scheimpflug imaging and to compare the findings with those for healthy controls. Methods: This single-center, case-control study included patients diagnosed with retinitis pigmentosa who were followed up at the Department of Ophthalmology of Kayseri Training and Research Hospital between February and June 2018. Age- and sex-matched healthy individuals with no known ophthalmologic disease formed the control group. Both patients with retinitis pigmentosa and controls underwent comprehensive ophthalmic assessments, including the measurement of the best-corrected visual acuity calculation of the spherical equivalent, slit-lamp examination, stereoscopic fundus examination, computerized visual field test, and electroretinography. Topographic and aberrometric values were measured using Scheimpflug-based tomography. Results: This study was performed on 52 eyes of 26 patients with retinitis pigmentosa (14 men) and 52 eyes of 26 healthy controls (11 men). The average keratometry (K avg) values for the patient and control groups were similar (43.87 ± 2.23 versus 43.61 ± 1.68; p=0.546), but the maximum keratometry (K max) value was significantly higher in the patient group (45.85 ± 2.35 and 44.69 ± 1.86; p=0.015). Patients with retinitis pigmentosa had a significantly lower central corneal thickness (518.5 ± 42.3 versus 534.1 ± 24.5, respectively; p=0.042) and maximal corneal thickness (509.1 ± 50.5 versus 530.5 ± 24.1, respectively; p=0.015). Additionally, the iridocorneal angle for the patients was significantly lower (31.6 ± 9.2 versus 35.9 ± 7.7, p=0.025). The aberrometric findings indicated that patients with retinitis pigmentosa had significantly more higher-order aberrations than those in the healthy controls (0.794 ± 51 and 0.398 ± 08, respectively; p<0.001). Conclusions: The results of the present study demonstrated that patients with retinitis pigmentosa have different anterior segment parameters and corneal aberrations compared to healthy controls. These results should be supported by further studies.


RESUMO Objetivo: Este estudo visou avaliar parâmetros do segmento anterior e aberrações corneanas em pacientes com retinite pigmentosa através de imagens de Scheimpflug e comparar os achados com os de controles saudáveis. Métodos: Este foi um estudo caso-controle unicêntrico que incluiu pacientes com o diagnóstico de retinite pigmentosa em acompanhamento no Departamento de Oftalmologia do Hospital de Treinamento e Pesquisa de Kayseri, entre fevereiro e junho de 2018. Indivíduos saudáveis pareados por idade e sexo, sem nenhum conhecimento da doença oftalmológica formou o grupo controle. Ambos os pacientes com retinite pigmentosa quanto os controles foram submetidos a avaliações oftalmológicas abrangentes, incluindo a medição do cálculo da acuidade visual melhor corrigida, o cálculo do equivalente esférico, biomicroscopia, fundoscopia estereoscópica, campimetria computadorizada e eletrorretinografia. Os valores topográficos e de aberrometria foram medidos através de tomografia baseada no sistema Scheimpflug. Resultados: O estudo incluiu 52 olhos de 26 pacientes com retinite pigmentosa (14 homens) e 52 olhos de 26 controles saudáveis (11 homens). Os valores médios da ceratometria (K avg) para grupos dos pacientes e controle foram semelhantes (43,87 ± 2,23 versus 43,61 ± 1,68, p=0,546), mas o valor máximo da ceratometria (K max) foi significativamente maior no grupo de pacientes (45,85 ± 2,35 e 44,69 ± 1,86; p=0,015). Pacientes com retinite pigmentosa apresentaram uma espessura corneana central significativamente menor (518,5 ± 42,3 versus 534,1 ± 24,5, respectivamente; p=0,042) e espessura corneana máxima (509,1 ± 50,5 verus 530,5 ± 24,1, respectivamente; p=0,015). Além disso, o ângulo iridocorneano para os pacientes foi significativamente menor (31,6 ± 9,2 versus 35,9 ± 7,7; p=0,025). Os achados da aberrometria indicaram que os pacientes com retinite pigmentosa apresentaram significativamente mais aberrações de ordem superior em comparação com os controles saudáveis (respectivamente 0,794 ± 51 e 0,398 ± 08, respectivamente; p<0,001). Conclusões: Os resultados do presente estudo demonstraram que pacientes com retinite pigmentosa têm diferentes parâmetros do segmento anterior e aberrações corneanas em comparação com controles saudáveis. Estes resultados precisam ser confirmados por novos estudos.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Retinitis Pigmentosa/pathology , Cornea/pathology , Anterior Chamber/pathology , Reference Values , Case-Control Studies , Retinitis Pigmentosa/diagnostic imaging , Statistics, Nonparametric , Cornea/abnormalities , Cornea/diagnostic imaging , Corneal Topography/methods , Aberrometry/methods , Corneal Pachymetry/methods , Anterior Chamber/diagnostic imaging
14.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(6): 488-494, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1038692

ABSTRACT

ABSTRACT Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes.


RESUMO Objetivos: Este estudo aborda os resultados refrativos, topográficos, acuidade visual e tomografia de coerência óptica, 12 meses após a inserção do segmento de Anel de Ferrara em túnel corneano a 60% de profundidade com o laser de femtosegundo, em pacientes com ceratocone. Métodos: Série de casos não comparativos, prospectivos e intervencionistas. Realizamos a inserção do Anel de Ferrara através de incisão com o laser de femtosegundo em 15 olhos ceratocônicos. Foram incluídos pacientes com ceratocone documentado que voluntariamente assinaram consentimentos informados que tivessem melhor acuidade visual corrigida ≥0.30 tabela logMAR, espessura corneana ≥400µm. Foram excluídos pacientes com cirurgia ocular prévia ou curvatura corneana > 65 dioptrias (D). As principais variáveis medidas foram acuidade visual corrigida e os parâmetros topográficos da córnea (ceratometria mais plana (K1), mais curva (K2) e ceratometria média (K médio), avaliadas no pré-operatório e com 1, 3, 6 e 12 meses de seguimento. Resultados: A média ± desvio padrão da acuidade visual sem correção e acuidade visual corrigida foi 1.03 ± 0.46 e 0.42 ± 0.13, respectivamente; o desvio padrão médio de 12 meses, a acuidade visual sem correção e acuidade visual corrigida foram de 0.72 ± 0.37 e 0.31 ± 0.16, respectivamente, sem diferenças significativas (p=0,05 para ambos). A melhora da acuidade visual corrigida foi estatisticamente significante após 3 meses (p=0,02), e após 6 meses (p=0,02). Os valores médios da linha de base K1, K2, e média (K médio) foram 48,35 ± 3,65D, 53,67 ± 3,38D, e 50,84 ± 3,36D, respectivamente. A média de 12 meses ± desvio padrão para K1, K2, e K médio foi 46,53 ± 3,70D, 49,83 ± 3,50 D, e 48,12 ± 3,49D respectivamente, com diferença estatisticamente significativas para todos os 3 parâmetros topográficos (p=0,01). Conclusões: A inserção do Anel de Ferrara a uma profundidade de 60% no estroma corneano produz resultados visuais, refracionais e ceratométricos satisfatórios em olhos com ceratocone.


Subject(s)
Humans , Male , Female , Adult , Refraction, Ocular/physiology , Visual Acuity/physiology , Corneal Stroma/surgery , Prosthesis Implantation/methods , Keratoconus/surgery , Keratoconus/physiopathology , Reference Values , Time Factors , Tonometry, Ocular/methods , Prospective Studies , Treatment Outcome , Statistics, Nonparametric , Corneal Topography/methods , Tomography, Optical Coherence , Corneal Surgery, Laser/methods , Corneal Pachymetry/methods
15.
Rev. bras. oftalmol ; 78(3): 162-165, May-June 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1013675

ABSTRACT

RESUMO Objetivo: Comparar o resultado entre dois tipos de tonômetros, tendo como padrão ouro a tonometria de aplanação, relacionando com a espessura corneana e suas validações como instrumentos de rastreio populacional. Métodos: Estudo transversal comparativo, realizado com 400 olhos do ambulatório de oftalmologia da Adachi Oftalmologia, em Macapá (Amapá), entre os valores médios da pressão ocular medidos pelo tonômetro Icare®, o Tonômetro Pneumático e o Tonômetro de Aplanação de Goldmann em função da espessura corneana. Foram divididos conforme a ECC em 3 grupos. Grupo 1: 260 olhos com ECC< 530µ; grupo 2: 217 olhos com ECC entre 530µ e 590µ; e, grupo 3: 157 olhos com ECC>590µ. Resultados: A ECC média obtida na paquimetria foi de 557µ, variando de 651µ a 477µ (desvio padrão de 32.9). A PIO média obtida pela TP foi de 19,4 mmHg (com desvio padrão de 2,32); pelo Icare® foi de 16,7mmHg (desvio padrão de 2,12); e, na TAG foi de 15.5 mmHg (desvio padrão de 2,02). Para paquimetrias inferiores a 530µ e superiores a 590µ a PIOm não diferiu significativamente entre a TAG e Icare® (p = 0,232), sendo estatisticamente significativa diferença obtida para córneas com ECC entre 530 e 590 µ. A PIOm obtida pelo TP foi significativamente maior do que a pressão ocular média dos TAG e Icare® (p < 0,001 para ambos) em todos os grupos. Conclusões: Os três métodos podem ser utilizados em campanhas de rastreamento, porém o Icare® se mostrou mais confiável que a TP, com valores obtidos estatisticamente mais confiáveis quando comparados à TP. Existe suficiente concordância entre o Icare e a TAG para recomendar o seu uso.


ABSTRACT Objective: To compare the result between two types of tonometres, using as gold standard the aplanation tonometry, relating to the corneal thickness and its validations as instruments of population screening. Methods: A comparative cross-sectional study was carried out with 400 eyes from the ophthalmology clinic of Adachi Ophthalmology, in Macapá (Amapá), between the mean values of ocular pressure measured by the Icare® tonometro, the Pneumatic Tonometer and the Goldmann Flattening Tonometro as a function of corneal thickness. They were divided according to ECC in 3 groups. Group 1: 260 eyes with ECC <530µ; group 2: 217 eyes with ECC between 530µ and 590µ; and, group 3: 157 eyes with ECC> 590µ. Results: The mean ECC obtained in pachymetry was 557µ, ranging from 651µ to 477µ (standard deviation of 32.9). The mean IOP obtained by PT was 19.4 mmHg (with a standard deviation of 2.32); by Icare® was 16.7mmHg (standard deviation of 2.12); and in the TAG it was 15.5 mmHg (standard deviation of 2.02). For pachymetry less than 530µ and greater than 590µ, PIOm did not differ significantly between TAG and Icare® (p = 0.232), and a statistically significant difference was obtained for corneas with ECC between 530 and 590 µ. The IOP obtained by the PT was significantly higher than the mean ocular pressure of the TAG and Icare® (p <0.001 for both) in all groups. Conclusions: All three methods can be used in screening campaigns, but Icare® proved to be more reliable than TP, with values obtained statistically more reliable when compared to TP. There is sufficient agreement between Icare and TAG to recommend its use.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Glaucoma/diagnosis , Ocular Hypertension/diagnosis , Intraocular Pressure/physiology , Glaucoma/physiopathology , Cross-Sectional Studies , Air , Equipment Design , Corneal Pachymetry
16.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(1): 6-11, Jan.-Feb. 2019. tab
Article in English | LILACS | ID: biblio-973873

ABSTRACT

ABSTRACT Purpose: Obesity is associated with eye diseases, but the underlying structural changes and pathogenic mechanisms have not been examined in detail. Here, we assessed the effects of morbid obesity on the morphometric indices of eye disease. Methods: Morbidly obese volunteers (n=101, body mass index [BMI] ³40) and healthy individuals (n=95, BMI: 18.50-24.99) were examined by Goldman applanation tonometry, pachymetry, and spectral domain optical coherence tomography. Intraocular pressure, anterior chamber depth, axial length, central corneal thickness, retinal nerve fiber layer thickness, central foveal thickness, and choroidal thickness were compared between groups. Results: Uncorrected intraocular pressure was significantly greater in the morbidly obese group than in the healthy control group (15.5 ± 2.5 vs. 14.5 ± 2.6 mmHg, p=0.009), whereas axial length, anterior chamber depth, and central corneal thickness did not differ between the groups. The mean retinal nerve fiber layer thickness at the temporal quadrant was reduced in the morbidly obese group (72.7 ± 13.6 vs. 85.05 ± 52.6 mm, p=0.024). Similarly, the mean retinal thicknesses at nasal and temporal 1500-mm locations were lower in the morbidly obese group (346.6 ± 18.2 vs. 353.7 ± 18.8 mm, p=0.008; 323.1 ± 20.3 vs. 330.0 ± 18.9 mm, p=0.001). The mean choroidal thickness was also reduced in almost all measurement locations (fovea, temporal 500 and 1000 mm, and nasal 500, 1000, and 1500 mm) of the obese group (p<0.05). Weight and BMI were negatively correlated with subfoveal choroidal thickness (r=-0.186, p=0.009; r=-0.173, p=0.015). Conclusion: Morbid obesity is associated with elevated uncorrected intraocular pressure and signs of neuropathy and retinopathy. Obesity may thus increase the risks of glaucoma and glaucomatous optic neuropathy.


RESUMO Objetivo: A obesidade está associada a doenças oulares, mas as mudanças estruturais subjacentes e os mecanismos patogênicos não foram examinados detalhadamente. Aqui avaliamos os efeitos da obesidade mórbida nos índices morfométricos da doença ocular. Métodos: Voluntários obesos mórbidos (n=101, índice de massa corporal ³40) e indivíduos saudáveis (n=95, índice de massa corporal 18,50 a 24,99) foram examinados por tonometria de aplanação de Goldman, paquimetria e tomografia de coerência óptica de domício espectral. A pressão intraocular, profundidade da câmara anterior, comprimento axial, espessura central da córnea, espessura da camada de fibras nervosas da retina, espessura foveal central e espessura da coroide foram comparadas entre os grupos. Resultados: A pressão intraocular não corrigida foi significativamente maior no grupo com obesidade mórbida do que no grupo controle saudável (15,5 ± 2,5 vs. 14,5 ± 2,6 mmHg, p=0,009), enquanto que o comprimento axial, profundidade da câmara anterior e espessura central da córnea não diferiram entre os grupos. A espessura média da camada de fibras nervosas da retina no quadrante temporal foi reduzida no grupo com obesidade mórbida (72,7 ± 13,6 vs. 85,05 ± 52,6 mm, p=0,024). Da mesma forma, a média das espesuras da retinianas nas localizações nasal e temporal de 1500 m foi menor no grupo com obesidade mórbida (346,6 ± 18,2 mm vs. 353,7 ± 18,8 mm, p=0,008; 323,1 ± 20,3 mm vs. 330,0 ± 18,9 mm, p=0,001). A espessura média da coroide também foi reduzida em quase todos os locais de mensuração (fóvea, temporal 500 e 1000 mm, nasal 500, 1000 e 1500 mm) do grupo obeso (p<0,05). Peso e índice de massa corporal foram negativamente correlacionados com a espessura da coroide subfoveal (r=-0,186, p=0,009; r=-0,173, p=0,015). Conclusão: A obesidade mórbida está associada à elevada pressão intraocular não corrigida e a sinais de neuropatia e retinopatia. A obesidade pode, assim, aumentar os riscos de glaucoma e neuropatia óptica glaucomatosa.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Young Adult , Retinal Diseases/etiology , Obesity, Morbid/complications , Choroid Diseases/etiology , Retina/pathology , Retinal Diseases/physiopathology , Tonometry, Ocular/methods , Obesity, Morbid/physiopathology , Body Mass Index , Case-Control Studies , Choroid Diseases/physiopathology , Glaucoma/etiology , Glaucoma/physiopathology , Choroid/pathology , Statistics, Nonparametric , Tomography, Optical Coherence/methods , Corneal Pachymetry/methods , Intraocular Pressure
17.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(1): 18-24, Jan.-Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-973865

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of accelerated corneal crosslinking on corneal biomechanics with an ocular response analyzer in patients with progressive keratoconus. Methods: In this retrospective study, 50 eyes of 45 patients with progressive keratoconus who underwent accelerated corneal crosslinking were evaluated with ocular response analyzer waveform parameters before and one year after corneal crosslinking. Paired two-tailed Student's t-test was performed to compare the parameters before vs. after corneal crosslinking. Results: Mean patient age was 17.6 ± 3.6 (range 9-25) years. A significant increase was observed in p1 area, p2 area, h2, and dive2 values. No significant difference in corneal hysteresis, corneal resistance factor, or other waveform-derived parameters was observed at one year postoperatively. Conclusion: For estimating the effect of accelerated corneal crosslinking on corneal biomechanics, parameters such as p1 area, p2 area, h2, and dive2 are more sensitive than corneal hysteresis and corneal resistance factor. These results may help us to find out which corneal crosslinking method is most effective for stiffening the cornea.


RESUMO Objetivo: Avaliar o efeito do cross-linking corneano acelerado na biomecânica corneana com analisador de resposta ocular em pacientes com ceratocone progressivo. Métodos: Neste estudo retrospectivo, 50 olhos de 45 pacientes com ceratocone progressivo submetidos à cross-linking corneano acelerado foram avaliados com os parâmetros da forma de onda do analisador de resposta ocular antes e um ano após o tratamento com cross-linking corneano. O teste t de Student pareado bicaudal foi realizado para comparar os parâmetros antes e depois do cross-linking corneano. Resultados: A média de idade dos pacientes foi de 17,6 ± 3,6 (variação de 9 a 25) anos. Um aumento significativo foi observado nos valores de p1area, p2area, h2 e dive2. Nenhuma diferença significativa foi encontrada na histerese da córnea, fator de resistência da córnea ou outros parâmetros derivados da forma de onda foi observada em um ano de pós-operatório. Conclusão: Para estimar o efeito do cross-linking corneano acelerado na biomecânica corneana, parâmentros como p1area, p2area, h2 e dive2 são mais sensíveis que histerese da córnea e fator de resistência corneana. Esses resultados podem nos ajudar a descobrir qual método cross-linking corneano é mais eficaz no enrijecimento da córnea.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Keratoconus/surgery , Keratoconus/pathology , Reference Values , Riboflavin/therapeutic use , Vitamin B Complex/therapeutic use , Biomechanical Phenomena , Visual Acuity , Linear Models , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Cornea/surgery , Cornea/pathology , Corneal Topography/instrumentation , Cross-Linking Reagents/therapeutic use , Corneal Pachymetry/methods , Keratoconus/physiopathology
18.
Arq. bras. oftalmol ; Arq. bras. oftalmol;82(1): 68-71, Jan.-Feb. 2019. graf
Article in English | LILACS | ID: biblio-973863

ABSTRACT

ABSTRACT The authors describe an unusual association between posterior keratoconus and iris atrophy, confirmed by a complete ocular evaluation, scheimpflug imaging and pachymetric curve. A hypothesis for concomitant findings is discussed.


RESUMO Os autores descrevem a rara associação entre ceratocone posterior e atrofia de íris, confirmada por avaliação oftalmológica completa, imagens de scheimpflug e curva paquimétrica. Sugere-se uma hipótese que explique a concomitância de ambas as alterações.


Subject(s)
Humans , Female , Middle Aged , Iris/pathology , Iris Diseases/complications , Keratoconus/complications , Astigmatism/complications , Astigmatism/pathology , Atrophy , Amblyopia/complications , Amblyopia/pathology , Corneal Topography/methods , Corneal Pachymetry/methods , Keratoconus/pathology
19.
Article in Korean | WPRIM | ID: wpr-766884

ABSTRACT

PURPOSE: We compared and analyzed central corneal thickness (CCT) measurements according to the corneal thickness obtained with noncontact specular microscopy (NCSM) and ultrasound pachymetry (USP). METHODS: CCT was measured in the order of NCSM and USP by a single optometrist in 120 eyes of 120 healthy subjects. The measurements were compared between the devices and the measurement agreements and correlations between the devices were analyzed. To determine if the measurements differed depending on the thickness of the cornea, the patients were divided into three tertile groups from the thinnest patient by CCT measurement using USP, and then the differences in CCT measured by the two devices were analyzed. RESULTS: The CCT measurements using NCSM and USP were 548.25 ± 4.64 µm and 533.09 ± 35.96 µm, respectively. NCSM measurements were found to be thicker, showing statistically significant differences between the measurements (p < 0.001). The two examinations showed a high degree of correlation (r = 0.878; p < 0.01). In the three groups, the differences in CCT measurements between NCSM and USP were 12.93 ± 21.88 µm, 16.85 ± 15.89 µm, and 15.70 ± 20.46 µm, respectively, but the differences between the three groups were not statistically significant (p = 0.655). CONCLUSIONS: Our results show that although the differences in CCT measurements using NCSM and USP were consistent regardless of the corneal thickness, the CCT measurements by NCSM and USP were highly correlated.


Subject(s)
Humans , Cornea , Corneal Pachymetry , Healthy Volunteers , Microscopy , Ultrasonography
20.
Arq. bras. oftalmol ; Arq. bras. oftalmol;81(4): 310-315, July-Aug. 2018. tab, graf
Article in English | LILACS | ID: biblio-950468

ABSTRACT

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodology. Subjective comfort, visual acuity, central corneal thickness, endothelial cell count, and corneal-compensated intraocular pressure were evaluated. The follow-up period was one year. Results: Contact lens use was discontinued in 3 patients, thus leaving 24 eyes from 8 females and 7 males for analysis. The fitting characteristics were optimal in terms of lens position and movement. Statistically significant improvements were found in the best spectacle-corrected vision from before fitting to the visual acuity after fitting (p<0.001). Moreover, the patients reported high subjective comfort ratings and usage times (12.98 ± 2.3 hours/day). After one year of wear, visual acuity, subjective comfort, and usage time were maintained. No statistically significant adverse changes developed in the corneas over this period. Conclusion: Corneoscleral contact lenses with a multi-aspherical geometry design provide optimal visual acuity, improved comfort, and prolonged usage times in patients with irregular corneas after LASIK.


RESUMO Objetivo: Descrever os resultados do ajuste de lentes de contato corneoesclerais com geometria multiasférica em pacientes com córneas irregulares após cirurgia de ceratomileuse in situ assistida por laser (LASIK). Métodos: Esta foi uma série retrospectiva de 18 pacientes (idade, 26-38 anos) selecionados a partir de um banco de dados de uma clínica oftalmológica. Os participantes foram escolhidos ao manifestaram acuidade visual insatisfatória com suas lentes de contato ou óculos atuais depois de terem sido submetidos à LASIK para correção de miopia. Todos os pacientes receberam lentes de contato corneoesclerais projetadas para corrigir irregularidades na superficie da córnea. Um conjunto diagnóstico de prova foi usado para a adaptação e as avaliações foram feitas de acordo com uma metodologia padronizada. O conforto subjetivo, a acuidade visual, a espessura central da córnea, a contagem de células endoteliais e a pressão intraocular compensada da córnea foram avaliados. O período de acompanhamento foi de um ano. Resultados: O uso de lentes de contato foi descontinuado em 3 pacientes, deixando 24 olhos de 8 mulheres e 7 homens para análise. As características de adaptação foram ótimas em termos de posição e movimento da lente. Melhorias estatisticamente significativas foram encontradas na melhoria da visão corrigida por óculos antes de se ajustar a acuidade visual após a adaptação (p<0,001). Além disso, os pacientes relataram altos índices subjetivos de conforto e tempo de uso (12,98 ± 2,3 horas/dia). Após um ano de uso, a acuidade visual, o conforto subjetivo e o tempo de uso foram mantidos. Não houve alterações adversas estatisti­camente significativas nas córneas ao longo deste período. Conclusão: As lentes de contato corneoesclerais com projeto geométrico multiasférico proporcionam acuidade visual ideal, maior conforto e tempo de uso prolongado em pacientes com córneas irregulares após o LASIK.


Subject(s)
Humans , Adult , Contact Lenses, Hydrophilic , Keratomileusis, Laser In Situ/adverse effects , Corneal Wavefront Aberration/etiology , Myopia/surgery , Visual Acuity , Retrospective Studies , Follow-Up Studies , Corneal Topography , Corneal Wavefront Aberration/rehabilitation , Corneal Pachymetry
SELECTION OF CITATIONS
SEARCH DETAIL