Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Rev. bras. oftalmol ; 82: e0016, 2023. graf
Article in Portuguese | LILACS | ID: biblio-1431669

ABSTRACT

RESUMO Objetivo: Analisar retrospectivamente as alterações na ceratometria e no astigmatismo corneano obtidas após cirurgia de implante de anel intraestromal, comparando o uso de um segmento de arco longo versus o implante de dois segmentos de comprimento de arco tradicional. Métodos: A partir de um estudo transversal, obtivemos os dados de 94 olhos de pacientes diagnosticados com ceratocone, que foram submetidos ao implante de anel corneano. Eles foram divididos em dois grupos, dependendo do tipo de implante recebido: Grupo A, um segmento de arco longo; Grupo B, dois segmentos tradicionais. Todos os segmentos implantados possuíam 250µ de espessura. Os dados do pré-operatório dos dois grupos foram comparados, para garantir que as amostras eram similares (as diferenças encontradas entre os dois grupos não eram estatisticamente significativas). As variáveis analisadas no pré e no pós-operatório foram acuidade visual com correção, ceratometria, astigmatismo corneano e refração. Resultados: A amostra que recebeu apenas um segmento de arco longo (Grupo A) obteve redução da ceratometria média de 4,42D (8,7%) e do astigmatismo corneano de 2,43D (40,4%). Já na amostra dos olhos que receberam dois segmentos de arco tradicional (Grupo B), houve redução média de 2,66D (5,1%) em relação à ceratometria média e redução média de 2,11D (34,8%) em relação ao astigmatismo corneano. A redução obtida na ceratometria média no Grupo A foi maior que a obtida no Grupo B (diferença estatisticamente significativa). A redução obtida no astigmatismo do Grupo A não foi estatisticamente significante, se comparada com o resultado obtido no Grupo B (considerando p≤0,05). Conclusão: Foi demonstrado que o uso de um segmento de arco longo possui maior capacidade de aplanação corneana, se comparado com o uso de dois segmentos com comprimento de arco tradicional. Em relação à redução do astigmatismo, os dois grupos mostraram resultados equivalentes.


ABSTRACT Purpose: To retrospectively analyze the changes in corneal keratometry and astigmatism after intrastromal ring surgery, comparing the use of one long arch segment versus two traditional arc length segments. Methods: A cross-sectional study obtained data from 94 eyes of patients diagnosed with keratoconus that underwent surgical treatment with corneal ring implant. They were divided into two groups according to the type of implant received: one long-arch segment (Group A) or two traditional segments (Group B), both 250 microns thick. Preoperative data from the two groups were compared to ensure that the samples were similar (the differences between the two groups were not statistically significant). The variables (pre and post-operatively) analyzed were: best corrected visual acuity, keratometry, corneal astigmatism and refraction. Results: Group A, which received one long arch segment, showed a Km decrease of 4.42D (8.7%) and a corneal astigmatism reduction of 2.43D (40.4%). Group B, where the eyes acquired two traditional arch segments, showed an average Km decrease of 2.66D (5.1%) and corneal astigmatism reduction of 2.11D (34.8%). The mean keratometry (Km) reduction obtained was statistically significant (p≤0.05) when comparing both groups (A and B). The mean corneal astigmatism reduction was not statistically significant (p≤0.05) when comparing both groups (A and B). Conclusions: One long-arch segment has been demonstrated to have a greater capacity to reduce corneal curvature when compared to the use of two traditional-sized arch segments. No significant differences were found regarding the reduction of corneal astigmatism after comparing the results obtained in both groups.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Prostheses and Implants , Corneal Stroma/surgery , Prosthesis Implantation/methods , Keratoconus/surgery , Refraction, Ocular , Astigmatism , Visual Acuity , Cross-Sectional Studies , Treatment Outcome , Corneal Topography , Corneal Pachymetry
2.
Prensa méd. argent ; 106(7): 451-456, 20200000. graf
Article in English | LILACS, BINACIS | ID: biblio-1366974

ABSTRACT

Aim of the Study: Compare the corneal demarcation line (DL) depth after corneal collagen cross-linking (CXL) with subtotal versus customized corneal epithelium debridement using anterior segment optical coherence tomography (AS-OCT). Design: Prospective case-control study. Materials and Methods: The study enrolled 18 patients with bilateral progressive keratoconus. Both eyes treated by CXL using 3 mW/cm2 / 30 minutes setting. One eye with subtotal epithelial debridement (about 9 mm diameter) and the contralateral eye with customized debridement (approximately 1 mm single horizontal central scratch). One month postoperatively, patients had AS-OCT imaging to detect and measure the depth ofDL. Results: Patients' age mean was 25.17 years +/- 4.81 SD. Epithelial healing completed with in 3-7 days in conventional treatment group and demarcation line was evident in 16 eyes (89%) with a mean depth of 290.31 µm while in customized debridement group, the epithelial healing lasted less than 24 hours and DL was detectable in 10 patients (55.5 %) with a mean DL depth of 221 µm with a statistically significant difference (p < 0.05). Subjective postoperative pain graded as "moderate to severe" in about 77% of eyes underwent 9 mm epi-off CXL compared with 55% of those with customized debridement group. Conclusions: Although the DL if found in majority cases, but the shallow location in customized corneal debridement cases questioned the efficacy of this technique despite the quick re-epithelialization and less postoperative pain that accompanied it


Subject(s)
Humans , Adult , Middle Aged , Collagen , Epithelium, Corneal , Corneal Stroma/surgery , Debridement , Tomography, Optical Coherence , Keratoconus/pathology
3.
Arq. bras. oftalmol ; 82(6): 488-494, Nov.-Dec. 2019. tab, graf
Article in English | LILACS | ID: biblio-1038692

ABSTRACT

ABSTRACT Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes.


RESUMO Objetivos: Este estudo aborda os resultados refrativos, topográficos, acuidade visual e tomografia de coerência óptica, 12 meses após a inserção do segmento de Anel de Ferrara em túnel corneano a 60% de profundidade com o laser de femtosegundo, em pacientes com ceratocone. Métodos: Série de casos não comparativos, prospectivos e intervencionistas. Realizamos a inserção do Anel de Ferrara através de incisão com o laser de femtosegundo em 15 olhos ceratocônicos. Foram incluídos pacientes com ceratocone documentado que voluntariamente assinaram consentimentos informados que tivessem melhor acuidade visual corrigida ≥0.30 tabela logMAR, espessura corneana ≥400µm. Foram excluídos pacientes com cirurgia ocular prévia ou curvatura corneana > 65 dioptrias (D). As principais variáveis medidas foram acuidade visual corrigida e os parâmetros topográficos da córnea (ceratometria mais plana (K1), mais curva (K2) e ceratometria média (K médio), avaliadas no pré-operatório e com 1, 3, 6 e 12 meses de seguimento. Resultados: A média ± desvio padrão da acuidade visual sem correção e acuidade visual corrigida foi 1.03 ± 0.46 e 0.42 ± 0.13, respectivamente; o desvio padrão médio de 12 meses, a acuidade visual sem correção e acuidade visual corrigida foram de 0.72 ± 0.37 e 0.31 ± 0.16, respectivamente, sem diferenças significativas (p=0,05 para ambos). A melhora da acuidade visual corrigida foi estatisticamente significante após 3 meses (p=0,02), e após 6 meses (p=0,02). Os valores médios da linha de base K1, K2, e média (K médio) foram 48,35 ± 3,65D, 53,67 ± 3,38D, e 50,84 ± 3,36D, respectivamente. A média de 12 meses ± desvio padrão para K1, K2, e K médio foi 46,53 ± 3,70D, 49,83 ± 3,50 D, e 48,12 ± 3,49D respectivamente, com diferença estatisticamente significativas para todos os 3 parâmetros topográficos (p=0,01). Conclusões: A inserção do Anel de Ferrara a uma profundidade de 60% no estroma corneano produz resultados visuais, refracionais e ceratométricos satisfatórios em olhos com ceratocone.


Subject(s)
Humans , Male , Female , Adult , Refraction, Ocular/physiology , Visual Acuity/physiology , Corneal Stroma/surgery , Prosthesis Implantation/methods , Keratoconus/surgery , Keratoconus/physiopathology , Reference Values , Time Factors , Tonometry, Ocular/methods , Prospective Studies , Treatment Outcome , Statistics, Nonparametric , Corneal Topography/methods , Tomography, Optical Coherence , Corneal Surgery, Laser/methods , Corneal Pachymetry/methods
4.
Rev. bras. oftalmol ; 77(3): 159-164, May-June 2018. graf
Article in English | LILACS | ID: biblio-959083

ABSTRACT

Abstract We present a case of a 12-year-old patient with advanced keratoconus in both eyes who received a two-staged treatment in the right eye (OD) to decrease keratoconus progression rate and rehabilitate patient's vision. At the initial clinical examination, visual acuity without correction in OD was count fingers; cycloplegic refraction was -22.00 - 7,50 x 100° = 20/400; corneal topography demonstrated a curvature of 64.28 x 105° / 55.38 x 15°; and tomography (WaveLight - Allegro Oculyzer) demonstrated a curvature of 68.1 x 114° / 63.3 x 163° Q = -2.67. Initially, the patient received an intrastromal ring segment (210 mm / 200 µm) slightly off center to avoid the thinnest part of the cornea. Six months later a phakic lens was implanted in the anterior chamber. At the follow-up visit 13 months after phakic lens implantation (19 months after ring implantation), visual acuity in OD was 20/20 without correction; cycloplegic refraction was -0.50 -0.75 x 180o = 20/20; and corneal topography showed keratometry of 63.22 x 44o / 61.10 x 134o. The results demonstrated that the associated procedures were successful in decreasing irregular astigmatism and markedly improving patient's uncorrected visual acuity in OD, postponing the need for corneal transplantation to a more suitable age, if required.


Resumo Apresentamos o caso de um paciente de 12 anos de idade com ceratocone avançado em ambos os olhos, que recebeu um tratamento em dois estágios no olho direito (OD) de modo a diminuir a taxa de progressão do ceratocone e reabilitar a visão do paciente. No exame clínico inicial, a acuidade visual sem correção no OD era contar dedos; refração sob cicloplegia era -22.00 - 7,50 x 100° = 20/400; a topografia demonstrou uma curvatura de 64,28 x 105° / 55,38 x 15°; e a tomografia (WaveLight - Allegro Oculyzer) demonstrou uma curvatura de 68,1 x 114° / 63,3 x 163° Q = -2,67. Inicialmente, o paciente recebeu um segmento de anel intraestromal (210 mm /200 µm) ligeiramente fora de centro de modo a evitar a porção mais fina da córnea. Seis meses mais tarde, uma lente fácica foi implantada na câmara anterior. No acompanhamento de 13 meses após a implantação da lente fácica (19 meses após a implantação do anel), OD apresentava uma acuidade visual de 20/20 sem correção; uma refração sob cicloplegia de -0,50 -0,75 x 180o = 20/20; e a topografia da córnea demonstrou ceratometria de 63,22 x 44° / 61,10 x 134°. Os resultados demonstraram que a associação de procedimentos foi bem sucedida na diminuição do astigmatismo irregular, com uma melhora significativa da acuidade visual sem correção no OD, adiando a necessidade de transplante de córnea para uma idade mais adequada, caso necessário.


Subject(s)
Humans , Male , Child , Prostheses and Implants , Corneal Stroma/surgery , Lens Implantation, Intraocular/methods , Prosthesis Implantation/methods , Phakic Intraocular Lenses , Keratoconus/surgery , Anterior Chamber/surgery , Refraction, Ocular , Astigmatism/surgery , Visual Acuity , Biometry , Corneal Topography , Tomography, Optical Coherence , Corneal Pachymetry , Keratoconus/diagnosis , Microscopy
5.
Arq. bras. oftalmol ; 81(1): 66-69, Jan.-Feb. 2018. graf
Article in English | LILACS | ID: biblio-888176

ABSTRACT

ABSTRACT We report intraoperative finding of Granular Corneal Dystrophy Type-1 (GCD1) deposits after stromal pneumodissection in deep anterior lamellar keratoplasty (DALK) in a 61-year-old female. Pneumodissection was performed from the center to the periphery of the cornea, characterizing a big bubble type 1 technique which dissects the deep stroma from the predescemetic layer. After stromal removal, persistence of whitish deposits inside the predescemetic layer was noted. During post-operative evaluation, anterior biomicroscopy and anterior segment optical coherence tomography showed granular opacities between the patient's Descemet's membrane and the donor cornea, suggesting possible involvement of the predescemetic layer in GCD1. This may require the surgeon's attention to choose between DALK keratoplasty or penetrating keratoplasty.


RESUMO Relatamos o achado intraoperatório de persistência dos depósitos de Distrofia Granular Tipo 1 (GCD1) após pneumodissecção estromal no transplante de córnea lamelar anterior profundo (DALK) em uma mulher de 61 anos. A pneumodissecção começou a partir do centro para a periferia da córnea, caracterizando uma big bubble tipo 1, que disseca o estroma profundo da camada pré-Descemet. Após a remoção do estroma, notamos a persistência de depósitos esbranquiçados no interior da camada pré-Descemet. Na avaliação pós-operatória, a biomicroscopia anterior e a tomografia de coerência óptica do segmento anterior evidenciaram opacidades granulares entre a membrana de Descemet e a córnea doadora, sugerindo o possível envolvimento da camada pré-Descemet na GCD1, o que pode chamar atenção do cirurgião para decidir entre manter o DALK ou converter para transplante penetrante.


Subject(s)
Humans , Female , Middle Aged , Corneal Dystrophies, Hereditary/surgery , Corneal Transplantation/methods , Descemet Membrane/surgery , Corneal Dystrophies, Hereditary/pathology , Corneal Dystrophies, Hereditary/diagnostic imaging , Treatment Outcome , Corneal Stroma/surgery , Corneal Stroma/pathology , Corneal Stroma/diagnostic imaging , Tomography, Optical Coherence , Descemet Membrane/pathology , Descemet Membrane/diagnostic imaging , Slit Lamp Microscopy
6.
Clinics ; 72(6): 370-377, June 2017. tab
Article in English | LILACS | ID: biblio-840083

ABSTRACT

OBJECTIVES: To describe the indications for and visual outcomes of intrastromal corneal ring segment implantation. METHODS: A large retrospective case-series chart-review study was conducted using Sorocaba Ophthalmological Hospital medical records. This study included 1222 eyes (1196 patients) that were surgically treated between November 2009 and December 2012. The following preoperative data were collected: age, gender, type of medical care and funding source, surgical technique, best-corrected visual acuity, manifest sphere and cylinder refractive error, maximum and minimum central keratometry, and pachymetry measurements of the cornea at the thinnest point and at the ring channel. The postoperative best-corrected visual acuity and patient satisfaction were also determined. The cases were classified into six groups: four keratoconus groups (severe, advanced, moderate and mild), a pellucid marginal degeneration group and a post-graft irregular astigmatism group. This study was approved by the Brazilian Registry of Clinical Trials (UTN number 1111-1182-6181, TRIAL RBR-6S72RF). RESULTS: The age (mean±standard deviation) of the patients was 31.0±10.0 years. The most prevalent pathology was keratoconus (1147 eyes, 93.8%). A correlation was found between ectasia severity and medical assistance (p<0.001), and the most serious cases was treated by the Brazilian public health system. No complications were found in a total of 1155 surgeries, and after surgery, 959 patients were satisfied. Among the 164 dissatisfied patients, the majority failed to show improved best-corrected visual acuity. CONCLUSION: Patients in the public health system underwent surgical intervention for keratoconus later than those with private sources of funding. In the vast majority of operated cases, the patients reported improvements in vision.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Astigmatism/surgery , Corneal Edema/surgery , Corneal Stroma/surgery , Keratoconus/surgery , Prostheses and Implants , Prosthesis Implantation , Corneal Stroma/pathology , Retrospective Studies , Severity of Illness Index , Treatment Outcome , Visual Acuity
7.
Arq. bras. oftalmol ; 80(1): 52-56, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-838776

ABSTRACT

ABSTRACT We describe a case of late-onset remarkable depigmentation of a small aperture corneal inlay implanted for presbyopia compensation. The patient was a participant in a clinical trial designed to evaluate the safety and efficacy of the AcuFocusTM ACU-10R160, which is a 10 µm-thick polyimide film tinted with an organic dye. Inlay implantation occurred under mechanical microkeratome Lasik flaps set for a depth of 120 µm. The patient returned to the clinic 11 years after surgery and reported loss of near-vision acuity. Clinical examination showed the complete absence of pigments in the device and the total loss of the initial effect on near vision, despite normal distance vision. Manifest refraction remained stable during the follow-up period. Scheimpflug images characterized the loss of the small aperture effect on incoming light. Confocal analysis revealed small hyper-reflective round images on the endothelium and no signs of inflammation.


RESUMO Descrevemos um caso de importante despigmentação de início tardio de implante corneano de pequena abertura implantada para compensação de presbiopia. O paciente foi um dos participantes de ensaio clínico destinado a avaliar a segurança e eficácia do AcuFocusTM ACU-10R160, uma película de poliimida de 10 microns de espessura, tingida com um corante orgânico. A implantação ocorreu sob um flap de Lasik criado por microcerátomo mecânico ajustado para profundidade de 120 µm. O caso aqui descrito foi avaliado 11 anos após a cirurgia, relatando diminuição de acuidade de visão para perto. O exame clínico mostrou ausência total de pigmentos no dispositivo e perda total do efeito inicial na visão de perto, apesar da visão normal para distância. A refração manifesta permaneceu estável durante o período de seguimento. As imagens de Scheimpflug caracterizaram a perda do efeito da abertura pequena na luz entrante. A análise de microscopia confocal revelou pequenas imagens hiper-reflexivas redondas sobre o endotélio, sem sinais de inflamação.


Subject(s)
Humans , Female , Aged , Presbyopia/surgery , Prostheses and Implants , Corneal Stroma/surgery , Prosthesis Implantation/instrumentation , Keratomileusis, Laser In Situ/instrumentation , Refraction, Ocular , Surgical Flaps , Visual Acuity , Prosthesis Implantation/methods , Keratomileusis, Laser In Situ/methods
8.
Arq. bras. oftalmol ; 79(1): 30-32, Jan.-Feb. 2016. tab, graf
Article in English | LILACS | ID: lil-771897

ABSTRACT

ABSTRACT Purpose: To assess the impact of intrastromal corneal ring segments (ICRS) as a surgical alternative to corneal grafting in patients with keratoconus who were scheduled for a corneal transplant. Methods: This single-surgeon, single-center, retrospective, observational case series study included 19 eyes of 18 patients (mean age, 23.36 ± 6.22 years) with a confirmed diagnosis of keratoconus. These patients were enrolled from the State of Goiás, Brazil corneal graft waiting list. Following extensive pre-operative testing, including the measurement of best-corrected visual acuity (BCVA), applanation tonometry, biomicroscopy, funduscopy, pachymetry, and corneal topography, patients were implanted with Keraring® ICRS. Patients underwent clinical examination at postoperative days 1, 7, 30, 90, and 180 and were examined again 2 years following surgery. Results: At the 2-year cut-off following ICRS implantation (mean follow-up, 28.72 ± 4.71 months), there was a statistically significant improvement in BCVA (logMAR) from 0.59 ± 0.35 preoperatively to 0.35 ± 0.45 postoperatively ( p <0.01). Three of 19 eyes (15.8%) still required keratoplasty. In the remaining patients (84.2%), BCVA was managed with spectacles (52.6%) or contact lenses (31.6%). One patient developed infectious keratitis, requiring removal of ICR at the first postoperative visit. Conclusion: ICRS implantation may be a surgical alternative to keratoplasty in patients with keratoconus. This procedure may delay or even eliminate the need for keratoplasty in such patients.


RESUMO Objetivo: Avaliar o impacto do implante de anéis corneanos intraestromais como alternativa cirúrgica à ceratoplastia, em pacientes com ceratocone previamente inscritos na fila de espera para transplante de córnea. Métodos: Este estudo unicêntrico, retrospectivo, observacional analisou prontuários de 19 olhos de 18 pacientes (idade média de 23,36 ± 6,22) com diagnóstico de ceratocone, incluídos na lista de espera para transplante de córnea do estado de Goiás, Brasil. Após realização de exame oftalmológico completo pré-operatório, incluindo acuidade visual (AV) corrigida, tonometria de aplanação, biomicroscopia, fundoscopia, paquimetria e topografia corneana, os pacientes foram submetidos a cirurgia para implante de anel intracorneano Keraring®. Os mesmos foram submetidos a exame oftalmológico no 1o, 7o, 30o, 90o, 180o dias de pós-operatório, e também após 2 anos da cirurgia. Resultado: Após a visita final de 2 anos de acompanhamento (média de seguimento de 28,72 ± 4,71 meses), houve melhora estatisticamente significativa da AV corrigida (logMAR): 0,59 ± 0,35 no pré-operatório para 0,35 ± 0,45 do pós-operatório ( p <0,01). Três dos 19 olhos (15,8%) permaneceram com a indicação de ceratoplastia. A conduta para os demais (84,2%) foi correção óptica com óculos (52,6%) ou lente de contato (31,6%). Um paciente evoluiu com ceratite infecciosa no pós-operatório, tendo seus anéis removidos. Conclusão: O implante de anéis intraestromais mostrou ser uma alternativa eficaz ao transplante de córnea nesta série de casos. Esse procedimento pode ajudar a retardar ou eliminar a necessidade de indicação de ceratoplastia em pacientes com ceratocone.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Young Adult , Corneal Transplantation , Corneal Stroma/surgery , Keratoconus/surgery , Prostheses and Implants , Prosthesis Implantation , Corneal Topography , Postoperative Period , Reproducibility of Results , Retrospective Studies , Time Factors , Treatment Outcome , Visual Acuity , Waiting Lists
9.
Arq. bras. oftalmol ; 78(4): 212-215, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-759267

ABSTRACT

ABSTRACTPurpose:To evaluate the clinical outcomes of intrastromal corneal ring segment (ICRS) implantation to correct ectasia in eyes with prior refractive surgery.Methods:Forty-one eyes of 25 patients (13 men, 12 women; mean age, 28.66 years) with ectasia after refractive surgery [photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK)] were included in a nonrandomized, retrospective, observational case series. Corneal tunnels were created by mechanical dissection in all eyes. Main outcome measures included uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BCVA), refraction, keratometry, and computerized analysis of corneal topography. Patients were divided into two groups by the type of refractive surgery (Group A: PRK, Group B: LASIK).Results:The mean preoperative manifest astigmatism decreased from -1.88 to -0.84 D in Group A (p=0.096) and -3.18 to -1.77 D in Group B (p=0.000). The mean keratometric astigmatism decreased from -2.58 to -1.66 D in Group A (p=0.010) and -4.80 to -2.78 D in Group B (p=0.000). The mean spherical equivalent decreased from -2.97 to -2.05 D in Group A (p=0.065) and -3.31 to -2.42 D in Group B (p=0.014). No significant between-group differences were noted on the comparison of preoperative and postoperative results. No intraoperative or postoperative complications were observed.Conclusion:ICRS implantation is a useful treatment option for ectasia following refractive surgery, and it has significantly reduced the refractive cylinder and increased best spectacle-corrected visual acuity.


RESUMOObjetivo:Avaliar os resultados do implante de anel intraestromal de córnea para correção de ectasia pós-cirurgia refrativa.Métodos:Quarenta e um olhos de 25 pacientes, 13 homens e 12 mulheres, com ectasia pós-cirurgia refrativa (PRK ou LASIK) foram incluídos em um estudo não randomizado, retrospectivo e observacional. A média de idade no momento do implante do anel é de 28,66 anos. Em todos os olhos, o túnel corneano foi criado através da dissecção mecânica da córnea. Os resultados avaliaram acuidade visual sem correção (AVSC) e acuidade visual com correção (AVCC), refração, ceratometria e topografia corneana computadorizada. Os pacientes foram divididos em dois grupos de acordo com a cirurgia refrativa. Grupo A: PRK, Grupo B: LASIK.Resultados:A média do astigmatismo pré-operatório foi reduzida de -1,88 D para -0,84 D no grupo A (P=0,096) e de -3,18 D para -1,77 D no grupo B (P=0,000). A média do astigmatismo ceratométrico foi reduzida de -2,58 D para -1,66 D no grupo A (P=0,010) e de -4,80 para -2,78 D no grupo B (P=0,000). A média do componente esférico foi reduzida de -2,97 D para -2,05 D no grupo A (P=0,065) e de -3,31 D para -2,42 D no grupo B (P=0,014). Nenhuma diferença estatisticamente significativa foi observada entre os grupos, quando se comparou os resultados do pré e pós-operatório. Não ocorreram complicações intra ou pós-operatórias.Conclusão:O implante de anel intraestromal de córnea é uma boa opção para o tratamento de ectasia pós-cirurgia refrativa, tendo resultado na redução significativa do astigmatismo refracional e melhora da acuidade visual com correção.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Corneal Diseases/surgery , Keratoconus/etiology , Keratoconus/surgery , Keratomileusis, Laser In Situ/adverse effects , Prosthesis Implantation , Photorefractive Keratectomy/adverse effects , Corneal Topography , Corneal Diseases/etiology , Corneal Diseases/physiopathology , Corneal Stroma/surgery , Prostheses and Implants , Retrospective Studies , Refraction, Ocular/physiology , Treatment Outcome , Visual Acuity/physiology
10.
Arq. bras. oftalmol ; 77(6): 382-387, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-735805

ABSTRACT

Purpose: To describe quantitative and qualitative features of eyes with advanced bullous keratopathy assessed using ultrasound biomicroscopy, before and after anterior stromal puncture (ASP) or amniotic membrane transplantation (AMT) procedures to relieve chronic pain. Methods: The present descriptive comparative study included 40 eyes of 40 patients with chronic intermittent pain due to bullous keratopathy who were randomly assigned to one of the two treatments (AMT or ASP). Ultrasound biomicroscopy (Humphrey, UBM 840, 50 MHz transducer, immersion technique) was used, and a questionnaire about pain intensity was completed preoperatively and postoperatively at days 90 and 180, respectively. Exclusion criteria were age<18 years, presence of concurrent infection, ocular hypertension, and absence of pain. Results: In a 180-day follow-up, the AMT group exhibited mean central corneal thickness (CCT), 899.4 µm preoperatively and 1122.5 µm postoperatively (p<0.001); mean epithelial thickness (ET), 156.4 µm preoperatively and 247.8 µm postoperatively (p<0.001); and mean stromal thickness (ST), 742.9 µm preoperatively and 826.3 µm postoperatively (p=0.005). The ASP group exhibited mean CCT, 756.7 µm preoperatively and 914.8 µm postoperatively (p<0.001); mean ET, 102.1 µm preoperatively and 245.2 µm postoperatively (p<0.001); and mean ST, 654.6 µm preoperatively and 681.5 µm postoperatively (p<0.999). Correlations between CCT and pain intensity in the AMT group (p=0.209 pre- and postoperatively) and the ASP group (p=0.157 preoperatively and p=0.426 at the 180-day follow-up) were not statistically significant. Epithelial and stromal edema, Descemet’s membrane folds, epithelial bullae, and the presence of interface fluid were frequently observed qualitative features. Conclusion: CCT increased over time in both groups. The magnitude of CCT did not correlate with pain intensity in the sample studied. The presence of interface ...


Objetivo: Descrever as características quantitativas e qualitativas da biomicroscopia ultrassônica (UBM) em olhos com ceratopatia bolhosa avançada, antes e após os procedimentos de punção estromal anterior (ASP) ou transplante de membrana amniótica (AMT) para alívio de dor crônica. Métodos: Estudo comparativo descritivo incluindo 40 olhos de 40 pacientes com dor crônica intermitente devido a ceratopatia bolhosa, randomizados em duas modalidades de tratamento (AMT e ASP). Biomicroscopia ultrassônica (Humphrey, UBM 840, transdutor de 50 MHz, técnica de imersão) foi utilizada, e um questionário de avaliação da intensidade da dor foi aplicado no pré-operatório, e após 90 e 180 dias de pós-operatório. Critérios de exclusão foram: idade abaixo de 18 anos, presença de infecção, hipertensão ocular, e ausência de dor. Resultados: No seguimento de 180 dias, o grupo Transplante de membrana amniótica apresentou: média da espessura corneana central (CCT): 899,4 µm (pré), 1.122,5 µm (pós-operatório) (p<0,001); média da espessura epitelial (ET): 156,4 µm (pré), 247,8 µm (pós-operatório) (p<0,001); média da espessura estromal (ST): 742,9 µm (pré), 826,3 µm (pós-operatório) (p=0,005), e, grupo ASP apresentou: CCT média: 756.7 µm (pré), 914,8µm (pós-operatório) (p<0,001); ET média: 102,1 µm (pré), 245,2 µm (pós-operatório) (p<0,001); ST média: 654,6 µm (pré), 681.5 µm (pós-operatório) (p<0,999). A correlação entre intensidade da dor e espessura corneana central no grupo AMT (p=0,209 pré e pós-operatórios) e no grupo ASP (p=0,157 pré-operatório e p=0,426 aos 180 dias de seguimento) não foi significativa. Edema epitelial e estromal, dobras na membrana de Descemet, bolhas epiteliais, e presença de fluido na interface foram características qualitativas frequentemente observadas. Conclusão: A espessura corneana central aumentou ao longo do tempo em ambos os grupos. A magnitude da espessura corneana central não interfere na intensidade da dor ...


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Corneal Diseases/surgery , Corneal Diseases , Amnion/transplantation , Blister/surgery , Corneal Pachymetry , Corneal Stroma/pathology , Corneal Stroma/surgery , Corneal Stroma , Endothelium, Corneal/pathology , Endothelium, Corneal/surgery , Endothelium, Corneal , Eye Pain/surgery , Microscopy, Acoustic/methods , Pain Measurement , Postoperative Period , Preoperative Period , Punctures , Pain Management/methods , Palliative Care/methods , Statistics, Nonparametric , Surveys and Questionnaires , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL