Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 223
Filter
3.
ABC., imagem cardiovasc ; 34(3)2021. ilus
Article in Portuguese | LILACS | ID: biblio-1292756

ABSTRACT

O sinal RAC (retroaortic anomalous coronary ou artéria coronária anômala retroaórtica) é um achado desconhecido, descrito ao ecocardiograma transtorácico como uma estrutura tubular ecogênica, localizada na face atrial do sulco atrioventricular. Apresentamos um caso onde o sinal RAC se apresenta na ecocardiografia transesofágica (ETE). O conhecimento do sinal RAC e a avaliação com ETE aumentam a sensibilidade e a especificidade e conferem a oportunidade de avaliar características anatômicas de alto risco, importantes na avaliação do risco de morte súbita.(AU)


Subject(s)
Humans , Middle Aged , Myocardial Ischemia/etiology , Coronary Vessel Anomalies/genetics , Stroke/diagnosis , Death, Sudden/etiology , Heart Defects, Congenital , Sinus of Valsalva/abnormalities , Echocardiography/methods , Echocardiography, Transesophageal/methods
7.
ABC., imagem cardiovasc ; 33(3): [rev01], 2020.
Article in Portuguese | LILACS | ID: biblio-1117806

ABSTRACT

Nas últimas décadas, o aumento das indicações para dispositivos cardíacos eletrônicos implantáveis tem sido acompanhado pela elevação dos casos de complicações relacionadas ao seu uso, dentre elas a endocardite infecciosa. Apesar dos avanços diagnósticos e terapêuticos da doença, esta mantém elevada morbimortalidade. Os casos relacionados aos dispositivos apresentam importantes limitações referentes aos critérios e aos métodos diagnósticos que implicam na tomada de decisão terapêutica sobre retirada do dispositivo, com risco de morte e outras complicações. Ainda assim, o ecocardiograma mantém um grande valor no diagnóstico da endocardite infecciosa relacionada a dispositivos cardíacos e de suas complicações. O entendimento das limitações e dos desafios acerca do diagnóstico reforça a necessidade de mais estudos sobre do tema. O presente artigo visa descrever a epidemiologia, a microbiologia, os fatores de risco, a patogenia, o diagnóstico e o tratamento da endocardite infecciosa associada aos dispositivos cardíacos eletrônicos implantáveis, visando demonstrar, principalmente, o valor dos exames de imagem na abordagem dessa condição clínica, com ênfase nos achados ao ecocardiograma.


In recent decades, the increase in indications for implantable electronic cardiac devices has been accompanied by an increase in cases of complications related to their use, including infectious endocarditis. Despite the diagnostic and therapeutic advances of the disease, it maintains high morbidity and mortality. The cases related to the devices have important limitations regarding the criteria and diagnostic methods that imply in making a therapeutic decision about removing the device, with risk of death and other complications. Still, echocardiography remains of great value in the diagnosis of infective endocarditis related to cardiac devices and their complications. Understanding the limitations and challenges regarding diagnosis reinforces the need for further studies on the topic. This article aims to describe the epidemiology, microbiology, risk factors, pathogenesis, diagnosis and treatment of infective endocarditis associated with implantable electronic cardiac devices, aiming to demonstrate, mainly, the value of imaging tests in addressing this clinical condition , with emphasis on echocardiogram findings.


Subject(s)
Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/microbiology , Endocarditis, Bacterial/epidemiology , Heart Failure/drug therapy , Infections/therapy , Pacemaker, Artificial , Staphylococcus aureus/pathogenicity , Magnetic Resonance Imaging/methods , Vancomycin/administration & dosage , Comorbidity , Risk Factors , Defibrillators, Implantable , Echocardiography, Transesophageal/methods , Cardiac Resynchronization Therapy Devices , Floxacillin/administration & dosage , Positron Emission Tomography Computed Tomography/methods
8.
Arq. bras. cardiol ; 113(5): 915-922, Nov. 2019. tab, graf
Article in English | LILACS | ID: biblio-1055038

ABSTRACT

Abstract Background: Hepatopulmonary syndrome (HPS), found in cirrhotic patients, has been little studied in hepatosplenic schistosomiasis (HSS) and includes the occurrence of intrapulmonary vascular dilatations (IPVD). Contrast transesophageal echocardiography (cTEE) with microbubbles is more sensitive than contrast transthoracic echocardiography (cTTE) with microbubbles in the detection of IPVD in cirrhosis. Objective: To assess the performance of the cTEE, compared with that of cTTE, in detecting IPVD for the diagnosis of HPS in patients with HSS. Methods: cTEE and cTTE for investigation of IPVD and laboratory tests were performed in 22 patients with HSS. Agitated saline solution was injected in peripheral vein during the cTEE and cTTE procedures. Late appearance of the microbubbles in the left chambers indicated the presence of IPVD. Results of the two methods were compared by the Student's t-test and the chi-square test (p < 0.05). Results: cTEE was performed in all patients without complications. Three patients were excluded due to the presence of patent foramen ovale (PFO). The presence of IPVD was confirmed in 13 (68%) of 19 patients according to the cTEE and in only six (32%, p < 0.01) according to the cTTE. No significant differences in clinical or laboratory data were found between the groups with and without IPVD, including the alveolar-arterial gradient. The diagnosis of HPS (presence of IPVD with changes in the arterial blood gas analysis) was made in five patients by the cTEE and in only one by the cTTE (p = 0.09). Conclusion: In HSS patients, cTEE was safe and superior to cTTE in detecting IPVD and allowed the exclusion of PFO.


Resumo Fundamento: A síndrome hepatopulmonar (SHP), presente em pacientes cirróticos, é pouco estudada na esquistossomose hepatoesplênica (EHE) e inclui a ocorrência de dilatações vasculares intrapulmonares (DVP). O ecocardiograma transesofágico com contraste (ETEc) de microbolhas é mais sensível que o ecocardiograma transtorácico com contraste (ETTc) de microbolhas na identificação de DVP na cirrose. Objetivo: Avaliar o desempenho do ETEc comparado ao ETTc na identificação de DVP para diagnóstico de SHP em pacientes com EHE. Métodos: Incluímos 22 pacientes com EHE submetidos a ETEc e ETTc para pesquisa de DVP, além de exames laboratoriais. Os ETEc e ETTc foram realizados empregando-se solução salina agitada, injetada em veia periférica. A visualização tardia das microbolhas em câmaras esquerdas indicava presença de DVP. Os resultados foram comparados entre os dois métodos pelos testes t de Stu dent e qui-quadrado (significância p < 0,05). Resultados: Todos os 22 pacientes realizaram ETEc sem intercorrências. Foram excluídos três pela presença de forame oval patente (FOP), e a análise final foi realizada nos outros 19. A DVP esteve presente ao ETEc em 13 pacientes (68%) e em apenas seis ao ETTc (32%, p < 0,01). Não houve diferenças significativas nos dados clínicos e laboratoriais entre os grupos com e sem DVP, incluindo a diferença alveoloarterial de oxigênio. O diagnóstico de SHP (presença de DVP com alterações gasométricas) ocorreu em cinco pacientes pelo ETEc e em apenas um pelo ETTc (p = 0,09). Conclusão: Em pacientes com EHE, o ETEc foi seguro e superior ao ETTc na detecção de DVP não identificada ao ETTc, o que possibilitou adicionalmente excluir FOP.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Schistosomiasis/diagnostic imaging , Splenic Diseases/diagnostic imaging , Echocardiography/methods , Echocardiography, Transesophageal/methods , Dilatation, Pathologic/diagnostic imaging , Liver Diseases, Parasitic/diagnostic imaging , Sensitivity and Specificity , Contrast Media , Hepatopulmonary Syndrome/diagnosis , Hepatopulmonary Syndrome/diagnostic imaging , Microbubbles , Foramen Ovale, Patent/diagnosis
9.
Int. j. cardiovasc. sci. (Impr.) ; 32(5): 460-470, Sept-Oct. 2019. tab, graf, graf
Article in English | SES-SP, LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1040110

ABSTRACT

In atrial fibrillation (AF), the CHA2DS2-VASc score calculates the risk for stroke. Di Biase classified the left atrial appendage (LAA), using magnetic resonance imaging, into 4 morphological types and correlated it with cerebrovascular events. Transesophageal echocardiography (TEE) also evaluates LAA and is a more widespread technique. Objective: To evaluate, using TEE, the possibility of characterizing LAA and to analyze its morphological aspects using the CHA2DS2VASc score. Methodology: A total of 247 patients were divided into three groups considering the CHA2DS2-VASc score: Group 1: 0 and 1; Group 2: 2 and 3 and, Group 3: ≥ 4 points. TEE produced the echocardiographic data. LAA was classified into thrombogenic and non-thrombogenic morphologies. In the analysis of statistical tests, a significance level of 5% was adopted. Results: The average age was 50 and 16.2% presented AF. In Group 1, we observed normal variables with a lower prevalence of AF (8.7%, p < 0.001). In group 2, spontaneous contrast was detected in 26.7%, (p < 0.001), thrombus in 6.7% (p = 0.079) and flow velocity in LAA < 0.4 m/s in 22.7% (p < 0.001) of the cases. Group 3 presented the highest percentages of AF (31.8%, p < 0.001), stroke/TIA (77.3%, p < 0.001), EF < 55% (18.2%, p = 0.010) and higher prevalence of thrombogenic type LAA (72.7%, p = 0.014). A higher occurrence of stroke/TIA was observed in patients with thrombogenic LAA (25.2%) compared to the non-thrombogenic group (11.2%), (p = 0.005). Conclusions: The thrombogenic morphology of LAA identified in TEE presented a higher risk of stroke regardless of the CHA2DS2VASc score. Patients with higher scores had greater abnormalities in echocardiographic variables


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Atrial Fibrillation , Thrombosis , Echocardiography, Transesophageal/methods , Stroke/mortality , Stroke Volume , Magnetic Resonance Spectroscopy/methods , Tomography/methods , Statistical Analysis , Retrospective Studies , Risk Factors , Atrial Appendage , Diabetes Mellitus , Heart Failure , Hypertension
14.
Med. infant ; 26(2): 139-141, Junio 2019. ilus
Article in Spanish | LILACS | ID: biblio-1015939

ABSTRACT

El control ecocardiográfico al momento de la reparación de las cardiopatías congénitas es una estrategia cardiológica para mejorar los resultados quirúrgicos de nuestros pacientes. En este artículo les contamos cómo es el método, qué información nos brinda y cómo influye en la toma de decisiones en el quirófano y en el manejo posoperatorio (AU)


Echocardiographic monitoring at the time of congenital heart defects repair is a strategy to improve the surgical outcomes of our patients. In this article we discuss the method, what information it provides, and how it influences decision-making in the operating room and postoperative management (AU)


Subject(s)
Humans , Infant, Newborn , Infant , Child, Preschool , Child , Monitoring, Intraoperative/methods , Echocardiography, Transesophageal/adverse effects , Echocardiography, Transesophageal/methods , Heart Defects, Congenital/surgery , Heart Defects, Congenital/diagnostic imaging , Extracorporeal Circulation , Intraoperative Care
15.
Rev. bras. cir. cardiovasc ; 34(2): 229-232, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-990581

ABSTRACT

Abstract Advanced renal cell carcinoma accompanied by tumor thrombus in the venous system is present in up to 10% of cases. Extension of tumor thrombus above the diaphragm or into the right atrium represents level IV disease. Level IV tumors are typically treated with sterno-laparotomy approach with or without deep hypothermic circulatory arrest and veno-venous bypass. In this case report, the surgical technique for the resection of advanced RCC were described, with the concomitant use of transesophageal echocardiography for thrombus extraction without the veno-venous or cardiopulmonary bypass.


Subject(s)
Humans , Male , Female , Middle Aged , Carcinoma, Renal Cell/surgery , Thrombectomy/methods , Echocardiography, Transesophageal/methods , Venous Thrombosis/surgery , Kidney Neoplasms/surgery , Vena Cava, Inferior/surgery , Carcinoma, Renal Cell/diagnostic imaging , Tomography, X-Ray Computed , Reproducibility of Results , Treatment Outcome , Ultrasonography, Interventional , Venous Thrombosis/pathology , Kidney Neoplasms/diagnostic imaging
16.
ABC., imagem cardiovasc ; 32(2): 103-108, abr.-junh. 2019.
Article in Portuguese | LILACS | ID: biblio-994677

ABSTRACT

Introdução: O ecocardiograma transesofágico é um exame amplamente utilizado na prática clínica para investigação e diagnóstico de doenças cardíacas e não cardíacas. Apesar de seguro, trata-se de exame semi-invasivo e não isento de ris-cos. Casos de infecção associados ao ecocardiograma tran-sesofágico foram descritos e, devido ao potencial risco de transmissão de infecção durante sua realização, o objetivo deste trabalho foi revisar dados da literatura referentes à transmissão de infecção durante a realização do exame, bem como os métodos de prevenção. Métodos: Revisão de literatura sobre o tema realizada entre dezembro de 2017 e janeiro de 2018, por meio de pesquisa em portais científicos de domínio público, nas diferentes bases de dados de ciências da saúde, que incluíram artigos originais, diretrizes, revisões simples e sistemática, e relatos de casos, publicados em periódicos indexados nos últimos 20 anos. Resultados: Preencheram os critérios estabelecidos 13 artigos: uma re-visão sistemática sobre complicações associadas ao ecocar-diograma transesofágico, seis artigos que descreveram surtos bacterianos relacionados ao ecocardiograma transesofágico, a diretriz britânica sobre limpeza e desinfecção para sondas de ecocardiografia transesofágica, quatro artigos sobre reações adversas a resíduos de ortoftaldeído em sondas de ecocardiograma transesofágico e um artigo referente ao uso de capas protetoras para as sondas. Conclusão: O risco de infecção associado ao ecocardiograma transesofágico existe, apesar de pouco descrito na literatura. É recomendado o es-tabelecimento de protocolos específicos de desinfecção das sondas de ecocardiograma transesofágico e inspeção rotinei-ra das sondas. O fortalecimento das equipes de controle de infecção também é essencial para a detecção e a resolução de surtos relacionados ao ecocardiograma transesofágico


Subject(s)
Humans , Male , Female , Disinfection/methods , Echocardiography, Transesophageal/drug effects , Echocardiography, Transesophageal/methods , Infections , Environmental Pollution/prevention & control , Risk Factors , Review , Guidelines as Topic/standards , Probe , Diagnosis
19.
Rev. bras. anestesiol ; 69(2): 211-213, Mar.-Apr. 2019. graf
Article in English | LILACS | ID: biblio-1003395

ABSTRACT

Abstract We presented a 39-year-old female patient with life-threatening hypoxemia after tricuspid valve replacement because of Ebstein's anomaly. And the severe cyanosis is due to bioprosthetic valve stenosis and atrial septal defect. Anesthetic management of a patient with severe obstructive prosthetic valve dysfunction can be challenging. Similar considerations should be given to patients with Ebstein's anomaly to maintain the pressure equalized between the right and left atrial. Transesophageal echocardiography and cerebral oxygen saturation provided real time information in perioperative care.


Resumo Apresentamos o caso de uma paciente de 39 anos, com hipoxemia em risco de vida após a substituição da valva tricúspide devido à anomalia de Ebstein e cianose grave devido à estenose de valva bioprotética e comunicação interatrial. O manejo anestésico de um paciente com disfunção obstrutiva grave de prótese valvar pode ser um desafio. Os pacientes com anomalia de Ebstein também precisam de atenção especial para manter a pressão equalizada entre o átrio direito e o esquerdo. A ecocardiografia transesofágica e a saturação cerebral de oxigênio forneceram informações em tempo real nos cuidados perioperatórios.


Subject(s)
Humans , Female , Adult , Tricuspid Valve Stenosis/surgery , Cyanosis/etiology , Ebstein Anomaly/surgery , Anesthetics/administration & dosage , Bioprosthesis/adverse effects , Severity of Illness Index , Heart Valve Prosthesis/adverse effects , Echocardiography, Transesophageal/methods , Perioperative Care/methods , Heart Valve Prosthesis Implantation/methods , Heart Septal Defects, Atrial/surgery , Hypoxia/etiology
20.
Rev. bras. anestesiol ; 69(2): 197-199, Mar.-Apr. 2019. tab, graf
Article in English | LILACS | ID: biblio-1003409

ABSTRACT

Abstract According to the most recent guidelines, the use of intraoperative transesophageal echocardiography in valvular surgeries is well established, as well as its use in the diagnosis, management, and rescue of perioperative complications. The aim of this case report is to illustrate a condition in which its intraoperative use had a positive influence on the outcome.


Resumo O uso da ecocardiografia transesofágica no intraoperatório em cirurgias valvulares é bem estabelecido de acordo com os guidelines mais recentes, assim como o seu uso no diagnóstico, manuseio e resgate de complicações perioperatórias. O objetivo deste relato de caso é ilustrar uma situação em que o seu uso no intraoperatório influenciou de maneira positiva o seu desfecho.


Subject(s)
Humans , Male , Aged , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis Implantation/methods , Aneurysm, Dissecting/diagnostic imaging , Intraoperative Care/methods , Intraoperative Complications/diagnostic imaging , Aneurysm, Dissecting/etiology , Mitral Valve/surgery
SELECTION OF CITATIONS
SEARCH DETAIL