ABSTRACT
Objective:This study aims to analyze the threshold changes in distortion product otoacoustic emissions(DPOAE) and auditory brainstem response(ABR) in adult Otof-/- mice before and after gene therapy, evaluating its effectiveness and exploring methods for assessing hearing recovery post-treatment. Methods:At the age of 4 weeks, adult Otof-/- mice received an inner ear injection of a therapeutic agent containing intein-mediated recombination of the OTOF gene, delivered via dual AAV vectors through the round window membrane(RWM). Immunofluorescence staining assessed the proportion of inner ear hair cells with restored otoferlin expression and the number of synapses.Statistical analysis was performed to compare the DPOAE and ABR thresholds before and after the treatment. Results:AAV-PHP. eB demonstrates high transduction efficiency in inner ear hair cells. The therapeutic regimen corrected hearing loss in adult Otof-/- mice without impacting auditory function in wild-type mice. The changes in DPOAE and ABR thresholds after gene therapy are significantly correlated at 16 kHz. Post-treatment,a slight increase in DPOAE was observeds,followed by a recovery trend at 2 months post-treatment. Conclusion:Gene therapy significantly restored hearing in adult Otof-/- mice, though the surgical delivery may cause transient hearing damage. Precise and gentle surgical techniques are essential to maximize gene therapy's efficacy.
Subject(s)
Mice , Animals , Otoacoustic Emissions, Spontaneous/physiology , Hearing/physiology , Ear, Inner , Hearing Loss/therapy , Genetic Therapy , Auditory Threshold/physiology , Evoked Potentials, Auditory, Brain Stem/physiology , Membrane ProteinsABSTRACT
RESUMO Objetivo Verificar se o tratamento com os antivirais de ação direta para a hepatite C provocam efeitos adversos na audição. Métodos A casuística foi composta por 16 indivíduos portadores do vírus da hepatite C, de ambos os gêneros, com média de idade de 51 anos. Foram excluídos do grupo indivíduos com perda auditiva do tipo condutiva ou mista e que apresentassem fatores de risco para perda auditiva. A avaliação foi realizada em dois momentos: antes do uso dos antivirais de ação direta e após o término do tratamento de três meses. Incluiu os seguintes procedimentos: anamnese, inspeção do meato acústico externo, audiometria tonal liminar, limiar de recepção de fala, índice de reconhecimento de fala, medidas de imitância acústica e emissões otoacústicas evocadas por estímulo transiente e produto de distorção. Resultados: Houve baixa ocorrência de zumbido e vertigem. Não houve diferença estatisticamente significativa entre os resultados da avaliação pré-tratamento e pós-tratamento. Conclusão O tratamento com antivirais de ação direta contra o vírus da hepatite C não provocou efeitos adversos na função auditiva.
ABSTRACT Purpose To verify whether treatment with hepatitis C direct-acting antivirals has adverse effects on hearing. Methods The sample consisted of 16 individuals with hepatitis C virus, of both sexes, with an average age of 51 years. Individuals with conductive or mixed hearing loss who presented risk factors for hearing loss were excluded from the group. The evaluation was carried out in two moments: before the use of direct-acting antivirals and after the three-month treatment. It included the following procedures: anamnesis, external auditory canal inspection, pure tone audiometry, speech reception threshold, speech recognition index, acoustic immittance measures and transient and distortion product otoacoustic emissions. Results There was a low incidence of tinnitus and vertigo. There was no statistically significant difference between the results of the pre- and post-treatment assessment. Conclusion The treatment with direct-acting antivirals against the hepatitis C virus did not cause any adverse effects on hearing function.
Subject(s)
Humans , Male , Female , Middle Aged , Antiviral Agents/adverse effects , Hepatitis C/drug therapy , Risk Adjustment , Hearing Loss , Brazil , Longitudinal Studies , Otoacoustic Emissions, SpontaneousABSTRACT
RESUMO Objetivo avaliar o efeito da variação da intensidade de estimulação sobre as respostas das emissões otoacústicas produto de distorção em indivíduos com perda auditiva neurossensorial, utilizando um protocolo de gradiente de fase das emissões. Métodos estudo observacional transversal. Participaram 38 indivíduos com diagnóstico de perda auditiva neurossensorial de grau leve, moderado ou severo. Foram realizadas anamnese, meatoscopia, audiometria tonal liminar, logoaudiometria, imitanciometria, emissões otoacústicas produto de distorção e emissões otoacústicas residuais. As emissões otoacústicas residuais foram coletadas com o equipamento Echodia, modelo Elios®. O protocolo utilizado permite a variação dos parâmetros frequência e intensidade e as respostas são analisadas por meio do teste do Gradiente de Fase. As respostas registradas nas emissões residuais foram consideradas como "presente", "ausente" e "artefato", considerando a variação da fase em função de f1. Resultados Foram incluídas 72 orelhas. Houve diferença estatisticamente significativa nas frequências de 1300 Hz e 2000 Hz, ao comparar os resultados das emissões residuais. Ao correlacionar o resultado da audiometria e a intensidade de estimulação que evocou a emissão residual, houve correlação positiva para as frequências de 1000 Hz e 4000Hz. O "artefato" foi registrado, principalmente, nas frequências mais agudas: 56,2% em 3000 Hz e 58,2% em 4000 Hz. A emissão otoacústica residual presente foi registrada em 18,6% em 1000 Hz, 13,4% em 2000 Hz, 6,3% em 3000 Hz e 7,5% em 4000 Hz. Conclusão o aumento da intensidade de estimulação no exame de emissões pode auxiliar no estudo das células ciliadas residuais, desde que seja utilizado um protocolo capaz de diferenciar respostas fisiológicas de artefatos.
ABSTRACT Purpose To study the effect of stimulation intensity variation on the responses of distortion products in subjects with sensorineural hearing loss using a new protocol to register the otoacoustic emissions. Methods This is a cross-sectional observational study. The following procedures were performed: anamnesis, otoscopy, pure tone audiometry, speech audiometry, tympanometry, distortion product and residual otoacoustic emissions. The residual DPOAE were collected with the Echodia equipment, Elios®. The protocol that was developed allows the variation of frequency and intensity parameters and the responses are analyzed by phase gradient test. Responses recorded in residual otoacoustic emissions were considered "present", "absent" or "artifact". Results The total included ears was 72. On residual otoacoustic emissions test, at a frequency of 1300Hz and 2000Hz, there was statistically significant difference. By analyzing the average found in the audiometry and the results of residual emissions, only the frequency of 1300Hz showed a statistically significant association in all groups. By correlating the results of the audiometry and the stimulation intensity used to evoke the residual emission, there was positive correlation for the frequencies of 1000Hz and 4000Hz. The "artifact" was mostly recorded in the higher frequencies: 56.2% in 3000Hz and 58.2% in 4000 Hz. Residual EOAPD present was recorded as 18.6% at 1000Hz, 13.4% at 2000Hz, 6.3% at 3000Hz and 7.5% at 4000Hz. Conclusion The increased stimulation intensity in the otoacoustic emissions test can aid in the study of residual outer hair cells, as long as a protocol is used to check the correctness of the responses.
Subject(s)
Humans , Auditory Threshold , Otoacoustic Emissions, Spontaneous/physiology , Hair Cells, Auditory , Hearing Loss, Sensorineural/diagnosis , Cross-Sectional StudiesABSTRACT
RESUMO Objetivo Verificar as respostas das emissões otoacústicas (EOA) evocadas por estímulo transiente e produto de distorção em indivíduos com doença de Ménière. Métodos Estudo transversal com casuística composta por 60 indivíduos de 19 a 75 anos de idade, distribuídos em dois grupos: grupo estudo, com 32 indivíduos com diagnóstico médico de doença de Ménière, sem outros riscos, e grupo controle formado por 28 indivíduos com perda coclear, sem doença de Ménière, pareado por idade e gênero ao grupo estudo. Critério de elegibilidade: curva tipo A, sem perda condutiva ou mista ou suspeita de alteração retrococlear. A avaliação audiológica foi composta por anamnese, inspeção do meato acústico externo, audiometria tonal limiar, logoaudiometria, medidas de imitância acústica e emissões otoacústicas evocadas por estímulo transiente e produto de distorção. Resultados Os indivíduos com Ménière apresentaram maior ocorrência de perda unilateral, zumbido pitch grave, vertigem e plenitude auricular em relação ao controle. Nesses indivíduos, houve maior incompatibilidade entre os resultados das EOA e da audiometria tonal: nas perdas unilaterais, observaram-se alterações nas EOA nas orelhas com limiares auditivos normais do lado contralateral, caracterizando disfunções cocleares. Nas orelhas com perda coclear, houve presença de EOAT (por estímulo transiente) e ausência de EOAPD (produto de distorção), contrapondo-se ao grupo controle, que apresentou ausência de EOAT e de EOAPD, como o esperado em perdas cocleares de outras etiologias. Conclusão A pesquisa das emissões na doença de Ménière identificou disfunção coclear na orelha contralateral nos casos unilaterais e presença de EOAT com ausência de EOAPD nas orelhas com perda auditiva, diferenciando-se das perdas cocleares de outras etiologias.
ABSTRACT Purpose To verify the responses of Evoked Otoacoustic Emissions by transient stimulus and distortion product in individuals with Ménière's Disease. Methods Cross-sectional study with a sample composed of 60 individuals, aged 19 to 75 years, divided into two groups: study group, with 32 individuals with a medical diagnosis of Ménière's disease, without other risks and a control group formed by 28 individuals with cochlear loss without Meniere's disease, age and sex matched to the study group. Eligibility criteria: type A curve, without conductive or mixed loss or suspected retrocochlear alteration. The audiological evaluation consisted of anamnesis, inspection of the external acoustic meatus, pure tone audiometry, logoaudiometry, measures of acoustic immittance and transient evoked otoacoustic emissions and distortion product. Results Individuals with Ménière's disease had a higher occurrence of unilateral hearing loss, low pitch tinnitus, vertigo and ear fullness in relation to the control. In these individuals, there was greater incompatibility between the results of OAE and pure tone audiometry: in unilateral hearing loss, alterations in OAE were observed in ears with normal hearing thresholds on the contralateral side, characterizing cochlear dysfunctions. In the ears with cochlear loss, there was the presence of TEOAE and absence of DPOAE, in contrast to the control group, which showed the absence of TEOAE and DPOAE, as expected in cochlear losses of other etiologies. Conclusion The investigation of emissions in Ménière's disease identified cochlear dysfunction in the contralateral ear in unilateral cases and the presence of TOAE with absence of DPOAE in ears with hearing loss, differentiating from cochlear losses of other etiologies.
Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Audiometry, Pure-Tone , Auditory Threshold/physiology , Otoacoustic Emissions, Spontaneous/physiology , Meniere Disease/physiopathology , Case-Control Studies , Endolymphatic Hydrops/physiopathology , Hearing Loss, Sensorineural/etiologyABSTRACT
RESUMO Objetivo Investigar se há diferenças nos achados audiológicos periféricos e centrais entre indivíduos com limiares auditivos normais com e sem zumbido crônico e, com isso, entender quais exames auditivos são importantes nessa população. Métodos A amostra foi composta por conveniência, incluindo indivíduos de 18 a 59 anos, divididos em dois grupos: grupo 1 (G1), formado por sujeitos sem queixa de zumbido crônico e grupo 2 (G2), por indivíduos com zumbido crônico. A avaliação consistiu nos seguintes procedimentos: anamnese, audiometria de altas frequências (AAF), emissões otoacústicas transientes (EOAT), potencial evocado auditivo de tronco encefálico (PEATE)-clique, frequency following response (FFR) e o potencial evocado auditivo de longa latência (PEALL)-fala. Resultados O G2 apresentou valores aumentados para a AFF, com diferenças significativas. Para ambos os grupos, a EOAT mostrou predominância de presença de respostas. No PEATE, não houve diferenças estatisticamente significativas. No FFR, o G1 obteve maior amplitude de onda V e houve maior ocorrência de ausências no PEALL dos potenciais P1, N2 e P300, no G2. Conclusão A AAF, a análise da relação da onda V/I do PEATE, o FFR e o PEALL identificaram alterações nos indivíduos com zumbido crônico, demonstrando que tais procedimentos são promissores na avaliação dessa população.
ABSTRACT Purpose To investigate whether there are differences in peripheral and central audiological findings between individuals with normal hearing thresholds with and without chronic tinnitus, and thereby understand which hearing tests are most important in this population. Methods The sample was composed of convenience, including individuals from 18 to 59 years old, divided into two groups: Group 1 (G1) composed of subjects without complaints of chronic tinnitus, and Group 2 (G2) composed of individuals with chronic tinnitus. The evaluation consisted of the following procedures: Anamnesis, High-frequency audiometry (HFA), Transient Otoacoustic emissions (TOAEs), Auditory Brainstem Response (ABR)-click, Frequency Following Response (FFR), and Long Latency Auditory Evoked Potential (LLAEP)-speak. Results G2 showed increased values for HFA, with significant differences. For both groups, TOAEs showed a predominance of responses. In ABR there were no statistically significant differences. In FFR, G1 obtained a greater amplitude of wave V and there was a greater absence in LLAEP of P1, N2, and P300 in G2. Conclusion The HFA, the analysis of the wave V/I ratio in ABR, the FFR, and the LLAEP identified alterations in individuals with chronic tinnitus, demonstrating that such procedures are promising in the evaluation of this population.
Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Auditory Threshold/physiology , Tinnitus/diagnosis , Tinnitus/therapy , Evoked Potentials, Auditory, Brain Stem/physiology , Otoacoustic Emissions, Spontaneous/physiology , Case-Control StudiesABSTRACT
RESUMO Objetivos Buscar na literatura informações quanto aos aspectos que guiam o monitoramento audiológico infantil, descrevendo os procedimentos utilizados, a idade em que são realizados, qual a população monitorada e os países que mais estudam sobre o assunto. Além de discutir a importância dessa etapa e a eficácia desses aspectos. Estratégia de pesquisa A revisão foi conduzida com base nas recomendações PRISMA e registrada na plataforma PROSPERO. Os estudos foram pesquisados nas bases de dados eletrônicas Medline (Pubmed), Web of Science e SciELO, com os descritores hearing, neonatal screening e follow up. Critérios de seleção Foram incluídos estudos que descrevessem o monitoramento audiológico. Não foram empregados filtros do ano de publicação, tampouco para os idiomas dos mesmos. Resultados Foram encontrados 432 artigos e 21 foram incluídos nesse estudo, sendo que a maioria foi produzida em países desenvolvidos. O Potencial Evocado Auditivo de Tronco Encefálico e a Avaliação Comportamental foram os procedimentos mais utilizados. Quanto a idade e população, a maioria realiza o monitoramento até os três anos e em crianças com Indicadores para a Deficiência Auditiva. Conclusão Os estudos demonstraram que não há padrão entre os protocolos para a realização do monitoramento audiológico, porém foi possível identificar que as pesquisas apresentam uma maior concordância quanto a idade em que tal monitoramento acontece e qual a população que deve ser monitorada. Entretanto, embora haja discordâncias, os métodos de avaliação utilizados pelos estudos são eficazes para a detecção de perdas auditiva de caráter leve, progressivo e/ou tardio, além dos casos de falso negativo.
ABSTRACT Purpose To search the literature for guidelines on infant's audiological monitoring, most commonly used procedures, the age at which they are performed, which population should be monitored and the countries that study the subject the most. Besides, the importance and effectiveness of these measures will be discussed. Research strategy The review was conducted based on the PRISMA recommendations, registered on the PROSPERO platform. The studies were searched for in the electronic databases Medline (Pubmed), Web of Science and SciELO, using the descriptors hearing, neonatal screening and follow up. Selection criteria studies reporting the audiological monitoring were included. No filters on year and language of publication were used. Results A total of 432 articles were found and 21 were included in this study, mostly produced in developed countries. The Auditory Brainstem Response and the Behavioral Assessment were the most frequently used procedures. As to age and population, most infants are subjected to audiological monitoring up to three years of age and have Risk Factors for Hearing Loss in their clinical history. Conclusion The studies pointed that there is no standard among the protocols for performing audiological monitoring, but it was possible to identify agreement as to the age at which such monitoring takes place and which population should be monitored. However, although there is some disagreement, the assessment methods used in the studies are effective in detecting mild, progressive and/or late hearing loss, in addition to false negative cases.
Subject(s)
Humans , Infant, Newborn , Infant , Evoked Potentials, Auditory, Brain Stem , Audiology , Neonatal Screening , Hearing Loss/prevention & control , Otoacoustic Emissions, Spontaneous , Risk IndexABSTRACT
Resumo Introdução: As substâncias tóxicas presentes na fumaça do cigarro podem danificar as células ciliadas da cóclea. Esse efeito foi investigado pela mensuração das emissões otoacústicas. Objetivo: Investigar o impacto de estímulos nas emissões otoacústicas, comparar neonatos com e sem exposição à fumaça de cigarro durante a gestação. Método: Testes de emissões otoacústicas evocadas transientes, evocadas por estímulo tipo clique e emissões otoacústicas por produto de distorção, evocadas por dois tons, foram feitos em ambas as orelhas, com um aparelho Interacoustic TITAN. O estudo incluiu 105 neonatos divididos em dois grupos: um grupo de estudo, que compreendeu 47 neonatos expostos à fumaça durante a gravidez; e um grupo controle constituído por 58 neonatos que não foram expostos. Todos os participantes apresentaram triagem auditiva neonatal normal. Resultados: Não foram encontradas diferenças estatísticas nos níveis de resposta das emissões otoacústicas por produto de distorção entre os grupos. Nos testes de emissões otoacústicas evocadas transientes, foram observados menores níveis de resposta no grupo de estudo do que no grupo controle na análise de bandas de frequências da orelha direita, com diferenças estatisticamente significantes nos sinais e relação sinal-ruído (exceto a 1 kHz). Conclusão: O impacto da exposição ao fumo pôde ser analisado por meio das emissões otoacústicas evocadas transientes em neonatos. O efeito da exposição à fumaça durante a gravidez foi evidenciado por uma redução nos níveis das emissões otoacústicas evocadas transientes no grupo exposto. Esse mesmo efeito não foi observado para as análises feitas nos níveis das emissões otoacústicas por produto de distorção.
Subject(s)
Female , Humans , Infant, Newborn , Pregnancy , Smoke , Otoacoustic Emissions, Spontaneous , Neonatal Screening , Hearing Tests , NoiseABSTRACT
Abstract Introduction: Studies have demonstrated the ototoxic effects of antimalarial drugs in individuals who receive these drugs, but little is known regarding the toxicity of these drugs in the newborn auditory system when administered to the mother receive the drug during pregnancy. Objective: To verify the incidence of hearing loss in neonates who have no other associated risk indicators, born to mothers treated for malaria during pregnancy. Methods: A retrospective, quantitative cohort study was developed at Hospital de Base Dr. Ary Pinheiro and Clínica Limiar, both located in the municipality of Porto Velho (Rondônia). The sample consisted of 527 newborns divided into two groups: exposed to antimalarials drugs during pregnancy group (n = 32) and non-exposed group (n = 495). Data collection took place from September 2014 to December 2015, through an interview with the mothers and/or guardians of the newborn, through the newborns' and the mothers' records, and the neonatal hearing screening database of the above-mentioned institutions. Results: All the neonates in the exposed group, assessed through the recording of transient otoacoustic emissions associated with the automated brainstem auditory evoked potential test, underwent neonatal hearing screening in the first examination. Among the newborns in the non-exposed group, 30 showed failure and were retested. Of these, one continued to fail and was referred for diagnosis, in whom the results showed to be within the normal range. Among the neonates of the exposed group, infection with Plasmodium vivax was the most frequent, and was similarly distributed among the gestational trimesters, and chloroquine was the most commonly used antimalarial drug treatment more often given during the third trimester; these findings did not show any influence on the audiological findings of the studied neonates. Conclusion: The present study did not identify any cases of hearing loss in neonates born to mothers who used antimalarial drugs during gestation.
Resumo Introdução: Estudos comprovam os efeitos ototóxicos dos antimaláricos em pessoas que fazem uso destes medicamentos, porém pouco se sabe sobre a toxicidade destes fármacos no sistema auditivo de neonatos quando ingeridos pelas mães no período gestacional. Objetivo: Verificar a incidência de perda auditiva em neonatos de mães tratadas para malária durante a gestação sem outros indicadores de risco associados. Método: Estudo quantitativo, de coorte retrospectivo, desenvolvido no Hospital de Base Dr. Ary Pinheiro e na Clínica Limiar, ambos em Porto Velho (Rondônia). Compuseram a amostra 527 recém-nascidos divididos em dois grupos: grupo exposto (n = 32) e grupo não exposto (n = 495). A coleta de dados ocorreu de setembro de 2014 a dezembro de 2015, através de entrevista com as genitoras e/ou responsáveis pelo recém-nascido, investigação nos prontuários dos neonatos e das genitoras e no banco de dados da triagem auditiva neonatal das instituições supracitadas. Resultados: Todos os neonatos do grupo exposto, avaliados através do registro das emissões otoacústicas transientes associado a realização do potencial evocado auditivo de tronco encefálico automático passaram na triagem auditiva neonatal no primeiro exame. Já, entre os recém-nascidos do grupo não exposto, 30 apresentaram falha e foram retestados. Destes, um continuou falhando e foi encaminhado para diagnóstico, no qual foram evidenciados resultados dentro da normalidade. Nos neonatos do grupo exposto, a infecção pelo Plasmodium vivax foi a mais frequente, mostrando distribuição semelhante entre os trimestres gestacionais, sendo a cloroquina o antimalárico mais utilizado e o tratamento medicamentoso realizado mais frequentemente no terceiro trimestre, porém tais achados não mostraram influência sobre os achados audiológicos dos neonatos estudados. Conclusão: O presente estudo não identificou casos de perda auditiva nos neonatos de mães que utilizaram antimaláricos na gestação.
Subject(s)
Humans , Female , Pregnancy , Hearing Loss/diagnosis , Hearing Loss/chemically induced , Hearing Loss/epidemiology , Antimalarials/adverse effects , Brazil , Retrospective Studies , Cohort Studies , Evoked Potentials, Auditory, Brain Stem , Neonatal Screening , Otoacoustic Emissions, Spontaneous , Hearing TestsABSTRACT
RESUMO Objetivo Verificar a cobertura da triagem auditiva neonatal e sua associação com a quantidade de Fonoaudiólogos no SUS e de equipamentos disponíveis nas unidades federativas do Brasil nos anos de 2012 e 2018. Método O estudo é do tipo ecológico descritivo de séries temporais tendo como unidade de análise as Unidades de Federação do Brasil e os nascidos-vivos. Foi realizada a análise exploratória da cobertura da triagem auditiva neonatal e análise descritiva dos dados. O coeficiente de correlação do ranking de Spearman foi usado para medir a força e direção de associação entre duas variáveis ranqueadas. Resultados A COB no Brasil apresentou evolução de 24,1% para 67,6%. Observaram-se melhores coberturas estão nas Regiões Sul e Sudeste em 2012 e no ano de 2018 destacando-se a Região Sul e o estado do MS. A média do índice de fonoaudiólogos foi de 4,79 e 8,9/100.000 habitantes, respectivamente para os anos de 2012 e 2018. O índice da oferta de equipamentos de "Emissões Otoacústicas Evocadas Transientes" se manteve abaixo de 1/100.000 habitantes nos dois anos e em todas as unidades federativas do país. Conclusão A cobertura da triagem apresentou um aumento no Brasil, porém ainda abaixo do recomendado e está relacionada com o aumento da inserção de fonoaudiólogos no SUS. A distribuição espacial se apresenta heterogênea em todo seu território.
ABSTRACT Purpose To determine the coverage of newborn hearing screening (NHS) and its association with the availability of speech therapists in the National Health System (SUS) and equipment in the states of Brazil in 2012 and 2018. Methods This is a descriptive ecological time series study with the Brazilian states and live births as units of analysis. An exploratory analysis of newborn hearing screening coverage and descriptive data analysis were performed. Spearman's correlation coefficient was used to measure the strength and direction of the association between two ranked variables. Results Coverage in Brazil increased from 24.1% to 67.6%. Better coverage was observed in the South and Southeast regions in 2012, and in the former and Mato Grosso state (MS) in 2018. The average number of speech therapists was 4.79 and 8.9 / 100,000 inhabitants in 2012 and 2018, respectively. The index of "transient evoked otoacoustic emission" equipment was below 1 / 100,000 inhabitants in the two years in all the states of the country. Conclusion Screening coverage increased in Brazil, albeit below the recommended level, and is related to rising number of speech therapists in the SUS. Spatial distribution is heterogeneous throughout the country.
Subject(s)
Humans , Infant, Newborn , Speech , Otoacoustic Emissions, Spontaneous , Brazil , Mass Screening , Neonatal Screening , Allied Health PersonnelABSTRACT
RESUMO Objetivo Avaliar a função coclear de trabalhadores marítimos Offshore e Onshore de uma empresa naval da cidade do Rio de Janeiro e estimar a magnitude de associação entre a exposição ocupacional ao ruído e/ou substâncias químicas e alterações na função coclear. Método Neste estudo, foram avaliados trabalhadores marítimos entre 20-49 anos, de ambos os gêneros, sem queixas auditivas, distribuídos em dois grupos: o Grupo Offshore, que operam em alto mar com exposição ocupacional; e o Grupo Onshore, que operam em escritórios sem exposição ocupacional. Para avaliação da função coclear, foram realizados os exames de emissões otoacústicas evocadas por estímulo transiente (EOAT) e por produto de distorção (EOAPD). Resultados As respostas das EOAT e EOAPD foram, em média, menores no Grupo Offshore, para todas as frequências analisadas. A proporção de falhas observadas também foi maior no grupo de exposição (Offshore), tanto no critério geral quanto por frequência específica, principalmente para as frequências mais agudas de cada teste, 4 kHz para EOAT e 6 kHz para EOAPD. Conclusão Os resultados sugerem que a exposição a ruído e/ou a substâncias químicas pode contribuir significativamente para alterações da função coclear de trabalhadores marítimos, mesmo antes de manifestarem queixas auditivas.
ABSTRACT Purpose To evaluate the cochlear function of offshore and onshore seafaring workers of a naval company in the city of Rio de Janeiro and to estimate the degree of association between occupational exposure to noise and/or chemical substances and alteration in cochlear function. Methods This study evaluated seafaring workers aged 20 to 49, of both genders, without auditory symptoms, divided into two groups: the Offshore Group, operating in the high seas with occupational exposure; and the Onshore Group, operating in offices without occupational exposure. Exams were performed to evaluate cochlear function, including transient evoked otoacoustic emissions (TEOAE) and distortion product otoacoustic emissions (DPOAE). Results The TEOAE and DPOAE responses were on average lower in the Offshore Group, for all frequencies analyzed. The proportion of failures observed was also higher in the exposure group (Offshore), for general response and specific frequency, mainly for the frequencies of 4 kHz for TEOAE and 6 kHz for DPOAE. Conclusion The results suggest that exposure to noise and/or chemical substances can contribute to alterations in cochlear function in seafarers even without manifesting auditory symptoms.
Subject(s)
Humans , Male , Female , Adult , Young Adult , Otoacoustic Emissions, Spontaneous , Noise , Auditory Threshold , Brazil , Middle AgedABSTRACT
ABSTRACT Purpose: to describe the results of a neonatal hearing health program and verify whether there is an association between the presence of risk indicators for hearing loss and failure in the tests and diagnosis. Methods: a one-cohort, observational, retrospective study with secondary data contained in a spreadsheet concerning the family's sociodemographic condition, clinical history, and examination results of 7,800 participants who were submitted to hearing screening between 2010 and 2016. Absolute frequency and percentages were used in the description of the first and second stages. In the association between risk indicators and failures in the otoacoustic emissions, the odds ratio, confidence interval, and significance level at 0.5% were used. Results: the risk indicators in 8 out of the 12 infants presented with hearing loss were ototoxic medication and intensive care unit (ICU) stay, whereas the likelihood of failure in the otoacoustic emissions occurred along with 11 indicators. The likelihood of a diagnosis of hearing loss was 13 times greater when there was a risk indicator, 18 times greater when an ototoxic medication had been used, and 16.62 times greater when they stayed in ICUs. Conclusion: the results show that knowing the indicators leads to considering the actions the team in charge should take.
RESUMO Objetivo: descrever os resultados de um programa de saúde auditiva neonatal e verificar se há associação entre presença de indicador de risco para perda auditiva e falhas nos testes e no diagnóstico. Métodos: trata-se do estudo de uma coorte, observacional e retrospectiva, com dados secundários contidos em planilha eletrônica sobre condições sociodemográficas da família, história clínica e resultados dos exames de 7.800 participantes que realizaram a Triagem Auditiva, de 2010 a 2016. Na descrição da primeira e segunda etapa, utilizou-se frequência absoluta e valores percentuais. Na associação entre indicador de risco com falhas nas EOA, utilizaram-se Odds Ratio, Intervalo de Confiança e nível de significância 0,5%. Resultados: dos 12 lactentes com perda auditiva, oito apresentaram como indicador de risco, a medicação ototóxica e permanência em UTI, sendo que a chance de falhar nas EOA ocorreu com onze indicadores. A chance do diagnóstico de perda auditiva foi 13 vezes maior quando há indicador de risco, 18 vezes maior quando usou medicação ototóxica e 16,62 vezes maior com permanência em UTI. Conclusão: os resultados mostram que conhecer os indicadores levará à reflexão de ações a serem adotadas pela equipe responsável.
Subject(s)
Humans , Infant, Newborn , Neonatal Screening/methods , Otoacoustic Emissions, Spontaneous , Hearing Loss/diagnosis , Hearing Tests , Retrospective Studies , Risk Factors , Hearing Loss/etiologyABSTRACT
RESUMO Objetivo verificar e comparar a ocorrência e magnitude do efeito inibitório da via auditiva eferente em crianças e adolescentes com processamento auditivo normal e alterado, identificando um valor de corte para uso na prática clínica. Métodos estudo prospectivo, com amostra composta por 30 crianças de 7 a 14 anos, sendo 15 com avaliação de processamento auditivo normal (grupo controle) e 15 com processamento auditivo alterado (grupo estudo). Ambos os grupos foram submetidos à anamnese e avaliados por meio dos testes de emissões otoacústicas evocadas por estímulos transientes na ausência e presença de ruído contralateral, avaliação audiológica básica e de processamento auditivo. Resultados houve menor ocorrência do efeito inibitório da via eferente no grupo estudo (p-valor=0,038). Os valores médios obtidos no grupo controle foram 0,71 na orelha direita e 0,87 na orelha esquerda e no grupo estudo, 0,55 na orelha direita e 0,41 na orelha esquerda. Os grupos controle e estudo diferiram de modo significativo na orelha esquerda. Conclusão houve redução do efeito inibitório da via eferente em crianças e adolescentes com transtorno de processamento auditivo, sugerindo alteração funcional do sistema eferente olivococlear medial. O valor que separou as crianças com e sem alteração do sistema eferente foi de 0,55 dB na prática clínica, com 70% de sensibilidade e 66,7% de especificidade.
ABSTRACT Purpose Verify and compare the occurrence and magnitude of the inhibitory effect of the efferent auditory pathway in children and adolescents with normal and auditory processing disorder, identifying a cutoff value to use in clinical settings. Methods A prospective study, with a total sample of 30 children aged 7 to 14 years, half with normal auditory processing assessment (Control Group) and the other half with auditory processing disorder (Study Group). Both groups were submitted to anamnesis and evaluated using the otoacoustic emissions tests evoked by transient stimuli in the absence and presence of contralateral noise, basic audiological evaluation and auditory processing. Results The study group presented a lower occurrence of the inhibitory effect of the efferent pathway when compared to the control group (p value=0.038). The mean values obtained for the control group were 0.71 in the right ear and 0.87 in the left ear and for the study group, 0.55 in the right ear and 0.41 in the left ear. The two groups showed a statistically significant difference for the left ear. Conclusion There was a reduction in the inhibitory effect of the efferent pathway in children and adolescents with auditory processing disorder, suggesting a functional change in the medial olivocochlear efferent system. In this study, the cutoff value of 0.55 dB separated children with and without alteration of the efferent system with 70% sensitivity and 66.7% specificity.
Subject(s)
Humans , Child , Adolescent , Auditory Pathways , Auditory Perceptual Disorders/diagnosis , Otoacoustic Emissions, Spontaneous/physiology , Cross-Sectional Studies , Efferent PathwaysABSTRACT
The mixture of ketamine and xylazine is widely used for the auditory brainstem response (ABR) measurement. Esketamine is twice as potent as ketamine. Our objective was to assess the influence of esketamine in mice undergoing cochlear function measurement including ABR and distortion product otoacoustic emission (DPOAE) measurement. C57Bl/6J mice were treated with an equivalent dose of analgesia and received either a single intraperitoneal (ip) injection of 100 mg/kg ketamine and 25 mg/kg xylazine or 50 mg/kg esketamine and 25 mg/kg xylazine. Hearing thresholds, peak latencies of waves I and V, and DPOAE thresholds were recorded. Time to loss of righting and time to regain righting were also assessed. We found that hearing thresholds, the peak latencies of waves I and V, and DPOAE thresholds were similar between the two groups (all P>0.05). Time to regain righting was significantly shorter in the esketamine group (P<0.001) than in the ketamine group. We concluded that when using equivalent doses of analgesia, esketamine may be an ideal substitute for ketamine during cochlear function test.
Subject(s)
Animals , Rabbits , Ketamine , Xylazine , Evoked Potentials, Auditory, Brain Stem , Otoacoustic Emissions, SpontaneousABSTRACT
ABSTRACT Purpose: to determine the auditory effects of noise exposure from recreational and occupational sources among dentistry students. Methods: forty-two dentistry students, routinely exposed to occupational noise, and 72 students from other health science schools were recruited (control group). Audiometric testing, otoacoustic emissions and questionnaires to assess recreational and occupational noise were applied to the sample. The presence of a notch was determined for each participant audiometry´s test based on the criteria proposed by Coles et al. Differences in notch prevalence were analyzed by applying univariate regression models as well as a multivariate model adjusted by covariates. Results: non-significant differences in auditory thresholds between groups were found. The controls exhibited a significantly higher prevalence of a notch at 4 kHz than the group exposed to noise. However, the differences were not statistically significant in the multivariate model adjusted by recreational noise exposure. Conclusions: the occupational noise exposure was not significantly associated to auditory system dysfunction. In addition, the differences in notch prevalence could be related to recreational noise exposure.
RESUMEN Objetivo: determinar los efectos auditivos producto de la exposición a ruido recreacional y ocupacional en estudiantes de Odontología. Métodos: se reclutó a 42 estudiantes de odontología expuestos rutinariamente a ruido ocupacional, y a 72 estudiantes de otras carreras del área de la salud (grupo control). Se evaluó mediante audiometría, emisiones otoacústicas, junto con aplicar cuestionarios para determinar la exposición a ruido ocupacional y recreacional. A partir de los umbrales audiométricos e determinó la presencia de escotoma usando el criterio de Coles et al. Se analizaron las diferencias en prevalencia de escotomas entre los grupos mediante regresiones logísticas, ajustando por otras variables. Resultados: no existieron diferencias significativas en los umbrales audiométricos entre los grupos estudiados. El grupo control mostró mayor prevalencia de escotoma en 4 kHz al ajustar por sexo y edad, sin embargo, dejó de ser significativa al ajustar adicionalmente por exposición a ruido recreacional. Conclusiones: la exposición a ruido ocupacional no se asoció a alteraciones auditivas. Además, las diferencias en prevalencia de escotomas estarían relacionadas a exposición a ruido recreacional.
Subject(s)
Humans , Male , Female , Adult , Young Adult , Students, Dental/statistics & numerical data , Hearing Loss, Noise-Induced/diagnosis , Noise, Occupational/statistics & numerical data , Audiometry , Case-Control Studies , Cross-Sectional Studies , Otoacoustic Emissions, SpontaneousABSTRACT
La hipoacusia tiene una incidencia notable entre los recién nacidos. Una intervención temprana durante el período de maduración auditiva permite minimizar los efectos en el desarrollo intelectual del infante. Se propone el desarrollo de un Registrador de Emisiones Otoacústicas Transientes como parte de un sistema de cribado neonatal basado en microcontroladores de alto rendimiento. La prueba consiste en aplicar periódicamente un estímulo tipo chasquido para obtener la respuesta coclear. Se promedian las señales adquiridas y se aplica la Transformada Rápida de Fourier. El espectro obtenido es dividido en bandas de media octava para analizar la correlación y la relación señal-ruido. Si estos parámetros son mayores que los umbrales de referencia en la mayoría de las bandas, se considera al paciente apto para el desarrollo normal. El firmware fue implementado sobre el procesador STM32F405 y evaluado con el simulador Baby Isao; obteniéndose una sensibilidad del 87.5 por ciento y una especificidad del 93.75 por ciento(AU)
Hearing loss is highly incident among newborns. Early intervention during the period of auditory maturation allows adequate levels of intellectual development to be achieved. The development of a Transient Otoacoustic Emissions Recorder is proposed as part of a neonatal screening system based on high-performance microcontrollers. The test consists of periodically applying a click stimulus to obtain the cochlear response. The acquired signals are averaged and the Fast Fourier Transform is applied. The spectrum obtained is divided into half-octave bands to assess the correlation as well as the signal-noise ratio. If these parameters are greater than the reference thresholds in most of the bands, the patient is considered suitable for normal cognitive development. The firmware was implemented on the STM32F405 processor and evaluated with the Baby Isao simulator; obtaining a sensitivity of 87.5 percent and a specificity of 93.75 percent(AU)
Subject(s)
Humans , Male , Female , Infant , Neonatal Screening , Otoacoustic Emissions, Spontaneous , Fourier Analysis , Hearing Loss/epidemiologyABSTRACT
Introdução: a triagem auditiva neonatal (TAN) está disposta na Lei nº 12.303/2010, a qual, obriga a realização do teste da orelhinha em todos os hospitais e maternidades do Brasil. Porém, vários estados brasileiros ainda não atingiram o nível de cobertura satisfatória desse programa conforme preconizado. Objetivo: analisar a cobertura da triagem auditiva neonatal no período entre 2011 a 2018 nas macrorregiões do Estado da Bahia. Metodologia: estudo ecológico, quase-experimental, realizado por meio do tabulador genérico de domínio público desenvolvido pelo DATASUS. Resultados: a produção ambulatorial dos procedimentos da TAN no Estado da Bahia obteve crescimento considerável ao longo do período do estudo, porém os achados apontaram que as taxas de crescimentos anuais apresentaram um comportamento irregular no seu crescimento. Observou-se que a média das taxas de cobertura na Bahia é inferior à média nacional e muito discrepante quando comparada a média universal. Conclusão: os achados demonstraram que o Estado da Bahia segue com taxas de cobertura da TAN inferior ao preconizado pelo COMUSA (Comitê Multiprofissional de Saúde Auditiva), apresentando distribuição irregular na realização dos procedimentos, ausência de recursos tecnológicos em algumas macrorregiões, o que compromete o princípio da universalidade da TAN no Estado.
Introduction: the newborn hearing screening (NHS) is set out in Law Nº 12.303/2010, which requires the ear test to be performed in all hospitals and maternity hospitals in Brazil. However, several Brazilian states have not yet reached the level of satisfactory coverage of this program as recommended. Objective: to analyze the coverage of newborn hearing screening, between 2011 and 2018, in the macro-regions of the State of Bahia. Methodology: ecological, quasi-experimental study, carried out using the generic public domain tab developed by DATASUS. Results: the NHS procedures in the State of Bahia achieved considerable growth over the period of the study, however the findings pointed out that the annual growth rates showed an unstable behavior in their growth. It was observed that the average coverage rates in Bahia are lower than the national average and very different when compared to the universal average. Conclusion: the findings showed that the State of Bahia continues to have NHS coverage rates lower than recommended by COMUSA (Multiprofessional Hearing Health Committee), unstable distribution in the performance of procedures, there are no technological resources in some macro-regions, which compromises the principle of universality of NHS in the state.
Subject(s)
Health Services Coverage , Infant, Newborn , Neonatal Screening , Health Care Quality, Access, and Evaluation , Otoacoustic Emissions, Spontaneous , Evoked Potentials, Auditory , Database , Ecological StudiesABSTRACT
Abstract Introduction: Previous research has suggested that individuals with different blood groups show varied incidences of noise-induced hearing loss. The reduced otoacoustic emissions amplitudes indicate the higher possibilities of outer hair cell damage for noise exposure. Objective: The objective is to analyze the characteristics of otoacoustic emissions, including the occurrence of spontaneous otoacoustic emission and the amplitudes of distortion product otoacoustic emission at certain frequencies in full term neonates with different ABO blood groups. Methods: A total of 80 selected full-term female neonates who passed the initial newborn hearing screen were enrolled into the study, with equal number of participants in four ABO blood groups (Blood Group A, Blood Group B, Blood Group AB, Blood Group O). Measurements of spontaneous otoacoustic emission and distortion product otoacoustic emission were performed in both ears for all participants. Results: (1) The blood group O participants showed significantly fewer spontaneous otoacoustic emission occurrences than the other three blood groups (A = 70%, B = 80%, AB = 67%, O = 25%, p < 0.05). (2) The blood group O participants showed lower DPOAE amplitudes at 1257 Hz (M = 4.55 dB, SD = 8.36), 1587 Hz (M = 11.60 dB, SD = 6.57), 3174 Hz (M = 7.25 dB, SD = 5.99), 5042 Hz (M = 13.60, SD = 6.70) than participants with the other three blood groups in left ears (p < 0.05). In right ears, the blood group O participants showed reduced amplitudes at 1257 Hz (M = 6.55 dB, SD = 8.36), 1587 Hz (M = 13.60 dB, SD = 6.57), 3174 Hz (M = 7.65 dB, SD = 6.43), 5042 Hz (M = 13.65 dB, SD = 6.50) than participants from non-O blood groups (p < 0.05). Conclusion: Female individuals with blood group O have lower otoacoustic emissions values than individuals with the other three blood groups. We need to further investigate the possible relationships between ABO blood group and cochlear function, including the potential influences of noise damage on cochlear outer hair cells.
Resumo Introdução: Pesquisas anteriores sugeriram que indivíduos de diferentes grupos sanguíneos apresentam incidências distintas de perda auditiva induzida por ruído. As amplitudes reduzidas das emissões otoacústicas indicaram maiores ou menores possibilidades de danos às células ciliadas por exposição a ruídos. Objetivo: Analisar as características das emissões otoacústicas, inclusive a ocorrência de emissões otoacústicas espontâneas e as amplitudes de emissões otoacústicas por produto de distorção em determinadas frequências em neonatos a termo de diferentes grupos sanguíneos do sistema ABO. Método: Foram incluídos 80 neonatos a termo selecionados na triagem auditiva neonatal inicial para participar do estudo, com número igual de participantes de grupos sanguíneos do sistema ABO (grupo sanguíneo A, grupo sanguíneo B, grupo sanguíneo AB e grupo sanguíneo O). As emissões otoacústicas espontâneas e emissões otoacústicas por produto de distorção foram medidas em ambas as orelhas de todos os participantes. Resultados: (1) Os participantes do grupo sanguíneo O apresentaram ocorrências de emissões otoacústicas espontâneas significantemente menores do que os dos outros três grupos sanguíneos (A = 70%, B = 80%, AB = 67%, O = 25%, p < 0,05). (2) Os participantes do grupo sanguíneo O apresentaram amplitudes de emissões otoacústicas por produto de distorção mais baixas a 1257 Hz (M = 4,55 dB, DP = 8,36), 1587 Hz (M = 11,60 dB, DP = 6,57), 3174 Hz (M = 7,25 dB, DP = 5,99), 5042 Hz (M = 13,0, DP = 6,70) do que os participantes dos outros três grupos sanguíneos nas orelhas esquerdas (p < 0,05). Nas orelhas direitas, os participantes do grupo sanguíneo O apresentaram amplitudes reduzidas em 1257 Hz (M = 6,55 dB, DP = 8,36), 1587 Hz (M = 13,60 dB, DP = 6,57), 3174 Hz (M = 7,65 dB, DP = 6,43), 5042 Hz (M = 13,65 dB, DP = 6,50) em comparação aos participantes de grupos sanguíneos não O (p < 0,05). Conclusão: Os indivíduos do sexo feminino do grupo sanguíneo O apresentaram valores menores de emissões otoacústicas do que os indivíduos dos outros três grupos sanguíneos. É necessário continuar a investigar as possíveis relações entre o grupo sanguíneo ABO e a função coclear, inclusive as possíveis influências do dano por ruídos às células ciliadas externas da cóclea.
Subject(s)
Humans , Female , Infant, Newborn , Otoacoustic Emissions, Spontaneous , Blood Group Antigens , Hair Cells, Auditory, Outer , Term Birth , Hearing Loss, Noise-Induced , NoiseABSTRACT
Abstract Introduction: This study presents the effect of cypermethrin on the cochlear function in Wistar rats post-subchronic inhalation exposure. Worldwide several pesticides are described as causing health disorders. Cypermethrin is currently one of the most commonly used, however, little is known about its harmful effects, especially related to hearing. Human studies have associated pesticides with hearing disorders, but they present limited conclusions due to the multiple factors to which the population is exposed, such as noise. Objective: Mimic human exposure to cypermethrin and to verify the effects on cochlear function. Methods: It is a subchronic inhalation animal study (6 weeks, 4 hours/day), using 36 male Wistar aged 60 day. Rats were randomly assigned into three groups: Control (12 rats exposed to inhalation of water); Positive Control for auditory lesion (12 rats administrated with 24 mg/kg intraperitoneal cisplatin); Experimental (12 rats exposed to inhalation of cypermethrin - 0.25 mg/L). Animals were evaluated by distortion product otoacoustic emissions pre- and post-exposure. Results: The frequencies of 8, 10 and 12 kHz in both ears (right p = 0.003; 0.004; 0.008 and left 0.003; 0.016; 0.005 respectively) and at frequencies 4 and 6 in the right ear (p = 0.007 and 0.015, respectively) in the animals exposed to cypermethrin resulted in reduction. Conclusion: Subchronic inhalation exposure to cypermethrin provided ototoxicity in rats.
Resumo Introdução: Este estudo apresenta o efeito da cipermetrina sobre a função coclear em ratos Wistar após exposição por inalação subcrônica. Em todo o mundo, vários pesticidas são descritos como causadores de distúrbios de saúde. A cipermetrina é atualmente um dos mais utilizados, porém pouco se conhece sobre seus efeitos deletérios, principalmente relacionados à audição. Estudos em humanos associaram pesticidas a alterações auditivas, mas apresentaram conclusões limitadas devido aos múltiplos fatores aos quais a população está exposta, como, por exemplo, o ruído. Objetivo: Mimetizar a exposição humana à cipermetrina e verificar os seus efeitos na função coclear. Método: Estudo de inalação subcrônica em animais (6 semanas, 4 horas/dia), 36 ratos machos Wistar com 60 dias. Os ratos foram distribuídos aleatoriamente em três grupos: controle (12 ratos expostos à inalação de água); controle positivo para lesão auditiva (12 ratos com administração de 24 mg/kg de cisplatina intraperitoneal); e experimental (12 ratos expostos a inalação de cipermetrina - 0,25 mg/L). Os animais foram avaliados por emissões otoacústicas por produto de distorção, pré e pós-exposição. Resultados: As frequências de 8, 10 e 12 kHz em ambas as orelhas (direita p = 0,003; 0,004; 0,008 e esquerda 0,003; 0,016; 0,005 respectivamente) e frequências 4 e 6 na orelha direita (p = 0,007 e 0,015, respectivamente) apresentaram redução nos animais expostos à cipermetrina. Conclusão: A exposição subcrônica por inalação à cipermetrina resultou em ototoxicidade em ratos.
Subject(s)
Animals , Male , Rats , Pyrethrins/toxicity , Otoacoustic Emissions, Spontaneous , Cisplatin , Rats, Wistar , Ototoxicity , Antineoplastic AgentsABSTRACT
Abstract Introduction: Deficient auditory processing can cause problems with speech perception and affect the development and evolution of reading skills. The efferent auditory pathway has an important role in normal auditory system functions like speech-in-noise perception, but there is still no general agreement on this. Objective: To study the performance of the efferent auditory system in a group of children with reading impairment in comparison with normal reading and evaluation of its relationship with speech-in-noise perception. Methods: A total of 53 children between the ages of 8-12 years were selected for the study of which 27 were with reading impairment and 26 were normal reading children. Transient evoked otoacoustic emissions suppression and auditory recognition of words-in-noise test were performed for all the children. Results: The average amplitude of transient evoked otoacoustic emissions suppression showed a significant difference between the two groups in the right (p = 0.004) and in the left ear (p = 0.028). Assessment of the relationship between transient evoked otoacoustic emissions suppression and monaural auditory recognition of words-in-noise scores showed a significant moderate negative relationship only in the right ear (p = 0.034, r = −0.41) of the normal reading children. Binaural auditory recognition of words-in-noise scores were significantly correlated with the amplitude of transient evoked otoacoustic emissions suppression in the right ear (p < 0.001, r = −0.75) and in the left ear (p < 0.001, r = −0.64) of normal reading children. In the reading impaired group, ?a weaker correlation was observed between binaural auditory recognition of words-in-noise scores and transient evoked otoacoustic emissions suppression in the right (p = 0.003, r = −0.55) and in the left ear (p = 0.012, r = −0.47). Conclusions: Transient evoked otoacoustic emissions suppression pattern in the reading impaired group was different compared with normal reading children, and this difference could be related to efferent system performance. Words-in-noise scores in children with impaired reading were lower than in normal reading children. In addition, a relationship was found between transient evoked otoacoustic emissions suppression and words-in-noise scores in both normal and impaired reading children.
Resumo Introdução: O processamento auditivo deficiente pode causar problemas na percepção da fala e afetar o desenvolvimento e a evolução das habilidades de leitura. A via auditiva eferente tem um papel importante nas funções do sistema auditivo normal, como a percepção da fala no ruído, mas ainda não há um consenso sobre isso. Objetivo: Estudar o desempenho do sistema auditivo eferente em um grupo de crianças com dificuldade de leitura em comparação às com leitura normal e avaliação de sua relação com a percepção da fala no ruído. Método: Foram selecionadas para o estudo 53 crianças entre oito e 12 anos, das quais 27 tinham dificuldade de leitura e 26 apresentavam leitura normal. A avaliação por emissões otoacústicas evocadas transientes e o teste auditory recognition of words-in-noise foram feitos em todas as crianças. Resultados: A amplitude média da supressão das emissões otoacústicas evocadas transientes mostrou diferença significante entre os dois grupos na orelha direita (p = 0,004) e esquerda (p = 0,028). A avaliação da relação entre a supressão das emissões otoacústicas evocadas transientes e os escores monoaurais do teste auditory recognition of words-in-noise mostrou uma relação negativa moderadamente significante apenas na orelha direita (p = 0,034, r = -0,41) das crianças com leitura normal. Os escores binaurais do auditory recognition of words-in-noise foram significantemente correlacionados com a amplitude de supressão das emissões otoacústicas evocadas transientes na orelha direita (p < 0,001, r = -0,75) e na orelha esquerda (p < 0,001, r = -0,64) das crianças com leitura normal. No grupo com dificuldade de leitura, uma correlação mais fraca foi observada entre os escores binaurais do auditory recognition of words-in-noise e supressão das emissões otoacústicas evocadas transientes, na orelha direita (p = 0,003, r = -0,55) e na esquerda (p = 0,012, r = -0,47). Conclusões: O padrão de supressão das emissões otoacústicas evocadas transientes no grupo com dificuldade de leitura foi diferente em comparação com as crianças com leitura normal e essa diferença pode estar relacionada ao desempenho do sistema eferente. Os escores de palavras no ruído em crianças com dificuldade de leitura foram menores do que nas crianças com leitura normal. Além disso, foi encontrada uma relação entre a supressão das emissões otoacústicas evocadas transientes e os escores de palavras no ruído tanto em crianças com leitura normal quanto nas com dificuldade de leitura.
Subject(s)
Humans , Male , Female , Child , Auditory Pathways/physiology , Speech Perception/physiology , Evoked Potentials, Auditory, Brain Stem/physiology , Otoacoustic Emissions, Spontaneous/physiology , Dyslexia/physiopathology , Efferent Pathways/physiology , Acoustic Stimulation , Case-Control Studies , NoiseABSTRACT
Abstract Objective: Investigate the auditory pathway in the brainstem of children with acute lymphoblastic leukemia submitted to chemotherapy (by intravenous or intrathecal infusion). Methods: Fourteen children aged between 2 and 12 years with diagnosis of acute lymphoid leukemia were evaluated. The following procedures were used: meatoscopy, acoustic immitance measurements, tonal audiometry, vocal audiometry, transient otoacoustic emissions, and auditory brainstem response. Results: From the 14 children with normal auditory thresholds, 35.71% showed an alteration in auditory brainstem response, with a predominance of hearing impairment in the lower brainstem. It was found that 80% of the children with alteration had used intrathecal methotrexate less than 30 days and that 40% had the highest cumulative intravenous methotrexate doses. Conclusion: Children with acute lymphoblastic leukemia submitted to chemotherapy, present auditory pathway impairment in the brainstem, with a predominance of a low brainstem.
Resumo Objetivo: Investigar a via auditiva em tronco encefálico de crianças com leucemia linfoide aguda submetidas à quimioterapia (por infusão intravenosa ou por via intratecal). Métodos: Foram avaliadas 14 crianças com idade entre 2 e 12 anos, com diagnóstico de leucemia linfoide aguda. Foram utilizados os seguintes procedimentos: meatoscopia, medidas de imitância acústica, audiometria tonal, audiometria vocal, emissões otoacústicas transientes e potencial evocado auditivo de tronco encefálico. Resultados: Das 14 crianças com limiares auditivos normais, 35,71% demonstraram alteração no Potencial Evocado Auditivo de Tronco Encefálico, com predomínio de comprometimento de via auditiva em tronco encefálico baixo. Verificou-se que 80% das crianças com alteração haviam feito uso do metotrexato via intratecal a menos de 30 dias e que 40% tinham as maiores doses acumulativas de metotrexato por via endovenosa. Conclusão: Crianças com leucemia linfoide aguda submetidas à quimioterapia apresentam comprometimento na via auditiva em tronco encefálico, com predomínio em tronco encefálico baixo.