ABSTRACT
La rotura traumática, simultánea y bilateral del tendón cuadricipital es una lesión infrecuente, generalmente asociada a otras enfermedades sistémicas tales como insuficiencia renal o trastornos endocrinos. Presentamos el caso de un varón sano y atleta de 38 años que sufrió esta lesión mientras realizaba una sentadilla en el gimnasio. (AU)
The traumatic bilateral and simultaneous quadriceps tendon rupture is a rare injury, usually associated with other systemic diseases such as renal insufficiency or endocrine disorders. We present the case of a 38-year-old healthy male athlete who sustained this injury while performing a squat at the gym. (AU)
Subject(s)
Humans , Male , Adult , Rupture/diagnostic imaging , Tendon Injuries/diagnostic imaging , Quadriceps Muscle/injuries , Quadriceps Muscle/diagnostic imaging , Rupture/surgery , Tendon Injuries/surgery , Magnetic Resonance Spectroscopy , Radiography , Ultrasonography , Quadriceps Muscle/surgery , Knee/surgery , Knee/diagnostic imagingABSTRACT
OBJECTIVE@#To analyze the causes, management and prevention of complications after micro-incision percutaneous repair of acute Achilles tendon rupture.@*METHODS@#A retrospective study indentyfied 279 patients with acute Achilles tendon rupture who underwent a mini-invasive procedure using the micro-incision percutaneous Achilles tendon suture system(MIPAS) from August 2008 to November 2019, including 269 males and 10 female;96 cases on the right side and 183 cases on the left side;aged from 18 to 64 years old with an average of (36.9±11.4 )years old. Surgery was performed 0.5 to 7 days with an average of(2.7±0.9 )days after injury. The incision-related complications, re-rupture, sural nerve injury, deep vein thrombosis, Achilles tendon adhesion, local pain, and ankle stiffness within 18 months after surgery were recorded, as well as the corresponding management and outcome, the causes and prevention measures were analyzed.@*RESULTS@#No superficial or deep infection was found in all patients, symptomatic Achilles tendon adhesion and ankle stiffness were not observed, delayed suture foreign-body reactions occurred in 2 cases (0.7%), re-rupture in 5 cases (1.8%), sural nerve injury in 3 cases (1.1%), 21 cases(7.5%) with skin invagination at puncture site, 2 cases (0.7%) with symptomatic vein thrombosis, and 45 cases (16.1%) of transient posterior medial malleolus pain. After individualized treatment, the function was good. American Orthopeadic Foot & Ankle Sciety(AOFAS) score was 93 to 100 with an average of(98.9±5.4) scores.@*CONCLUSION@#Despite the occurrence of unique complications with MIPAS, it shows low functionally-related complications rates, such as incision-related complications, re-rupture, sural nerve injury, deep vein thrombosis and ankle stiffness.
Subject(s)
Male , Humans , Female , Adolescent , Young Adult , Adult , Middle Aged , Achilles Tendon/injuries , Retrospective Studies , Treatment Outcome , Tendon Injuries/surgery , Rupture/surgery , Sutures , Acute Disease , Suture TechniquesABSTRACT
OBJECTIVE@#To evaluate the effectiveness of tendon insertion medialized repair in treatment of large-to-massive rotator cuff tears (L/MRCT).@*METHODS@#The clinical and imaging data of 46 L/MRCT patients who underwent arthroscopic insertion medialized repair between October 2015 and June 2019 were retrospectively analyzed. There were 26 males and 20 females with an average age of 57.7 years (range, 40-75 years). There were 20 cases of large rotator cuff tears and 26 cases of massive rotator cuff tears. Preoperative imaging evaluation included fatty infiltration (Goutallier grade), tendon retraction (modified Patte grade), supraspinatus tangent sign, acromiohumeral distance (AHD), and postoperative medializaiton length and tendon integrity. The clinical outcome was evaluated by visual analogue scale (VAS) score, American Society for Shoulder and Elbow Surgery (ASES) score, shoulder range of motion (including anteflexion and elevation, lateral external, and internal rotation) and anteflexion and elevation muscle strength before and after operation. The patients were divided into two groups (the intact tendon group and the re-teared group) according to the integrity of the tendon after operation. According to the medializaiton length, the patients were divided into group A (medialization length ≤10 mm) and group B (medialization length >10 mm). The clinical function and imaging indexes of the patients were compared.@*RESULTS@#All patients were followed up 24-56 months, with an average of 31.8 months. At 1 year after operation, MRI showed that the medializaiton length of supraspinatus tendon was 5-15 mm, with an average of 10.26 mm, 33 cases in group A and 13 cases in group B. Eleven cases (23.91%) had re-teared, including 5 cases (45.45%) of Sugaya type Ⅳ and 6 cases (54.55%) of Sugaya type Ⅴ. At last follow-up, the VAS score, ASES score, shoulder anteflexion and elevation range of motion, lateral external rotation range of motion, and anteflexion and elevation muscle strength significantly improved when compared with those before operation ( P<0.05); there was no significant difference in internal rotation range of motion between pre- and post-operation ( P>0.05). The Goutallier grade and modified Patte grade of supraspinatus muscle in the re-teared group were significantly higher than those in the intact tendon group, and the AHD was significantly lower than that in the intact tendon group ( P<0.05). There was no significant difference in other baseline data between the two groups ( P>0.05). Except that the ASES score of the intact tendon group was significantly higher than that of the re-teared group ( P<0.05), there was no significant difference in the other postoperative clinical functional indicators between the two groups ( P>0.05). There was no significant difference in the incidence of re-tear, VAS score, ASES score, range of motion of shoulder joint, and anteflexion and elevation muscle strength between group A and group B ( P>0.05).@*CONCLUSION@#Tendon insertion medialized repair may be useful in cases with L/MRCT, and shows good postoperative shoulder function. Neither tendon integrity nor medialization length shows apparent correlations with postoperative shoulder function.
Subject(s)
Male , Female , Humans , Middle Aged , Rotator Cuff Injuries/surgery , Retrospective Studies , Treatment Outcome , Rotator Cuff/surgery , Tendons , Rupture/surgery , Shoulder Joint/surgery , Arthroscopy/methods , Range of Motion, ArticularABSTRACT
PURPOSE@#Previous studies have confirmed that Achilles tendon occurs Achilles thickening after repair surgery of the rupture. Although this mechanism has been elucidated in the laboratory, there are few reports on its impact on clinical function. We designed a retrospective study to investigate the Achilles thickening after Achilles tendon rupture repair and its correlation between the elasticity and postoperative function.@*METHODS@#In this retrospective analysis, patients who underwent surgical treatment for acute Achilles tendon rupture from April 2016 to April 2020 were included. All the patients were regularly followed up at 3 months, 1 year, and 2 years after surgery. American Orthopaedic Foot Ankle Surgeon (AOFAS) scale and Leppilahti score were used to evaluate functional outcomes. Achilles elasticity was measured by ultrasound shear wave of elasticity. Achilles thickening was calculated as maximal transverse and longitudinal diameter in cross-sectional plane of magnetic resonance scan. Sample t-tests was used for different follow-up periods. Correlation between Achilles thickening and other factors were analyzed using Pearson's method. p < 0.05 indicates a statistically significant difference.@*RESULTS@#AOFAS scale and Leppilahti score at 1 year were significantly higher than at 3 months postoperatively (both p < 0.001). These functional scales were also improved at 2-year follow-up significantly (both p < 0.001). The dorsiflexion difference showed gradually recovery in each follow-up period (t = -17.907, p < 0.001). The elasticity of the Achilles appeared to continuously decreases during the postoperative follow-up period in all position sets (p < 0.001). In thickening evaluation, the cross-sectional area of the thickest plane of Achilles was significantly higher at 1 year postoperatively (310.5 ± 25.2) mm2 than that at 3 months postoperatively ((278.0 ± 26.2) mm2, t = -8.219, p < 0.001) and became thinner in 2-year magnetic resonance scan ((256.1 ± 15.1) mm2, t = 16.769, p < 0.001). The correlations between Achilles thickening, elasticity, and functional outcome did not show statistical significance (p > 0.05) in every follow-up period.@*CONCLUSION@#Achilles tendon thickens after surgery in the 1st year, but begins to gradually return to thinning about 2 years after surgery. There was no significant correlation between the increase and decrease of thickening and the patients' clinical function scores, Achilles elasticity, and bilateral ankle dorsiflexion difference.
Subject(s)
Humans , Achilles Tendon/surgery , Retrospective Studies , Treatment Outcome , Elasticity , Tendon Injuries/surgery , Rupture/surgeryABSTRACT
OBJECTIVE@#To investigate the morphological, histological and ultrastructural changes of acute closed rupture of Achilles tendon, in order to clarify the pathological basis of the injury and to explore the significance.@*METHODS@#From January 2015 to January 2019, 35 patients with acute Achilles tendon rupture who underwent the minimally invasive Achilles tendon suture technique were retrospectively analyzed. Among these patients, 12 cases in acute open Achilles tendon rupture group included 10 males and 2 females, with an average age of (35.1±9.7) years old ranging from 19 to 50, and the time from injury to operation was 2 to 8 hours with an average of(5.6±1.8);23 cases in acute closed Achilles tendon rupture group included 21 males and 2 females, with an average age of (35.5±6.6) years old ranging from 18 to 50, and the time from injury to operation was 3 to 15 hours with an average of (7.5±3.1). The gross appearance and imaging findings of the broken end of Achilles tendon tissue in the two groups were compared by naked eye observation and foot and ankle MRI at 4 to 6 hours before operation. HE staining, scanning and fluoroscopic electron microscopy, immunohistochemistry(Sirius red staining) were performed on the intraoperative Achilles tendon tissue specimens at 1 to 2 days after operation, the collagen fiber degeneration and local fat infiltration, collagen fiber shape, cell morphology and function, and the distribution of typeⅠand type Ⅲ collagen fibers in Achilles tendon were compared between the two groups.@*RESULTS@#Compared with the acute open Achilles tendon rupture group, the acute closed Achilles tendon rupture group had poor elasticity, hard texture, moderate edema, irregular shape of Achilles tendon broken end, horsetail shape, and more calcification around the broken end. HE staining results:the collagen fibers in the Achilles tendon of the acute open Achilles tendon rupture group were arranged irregularly, with hyaline degeneration and fat infiltration;The results of electron microscopy showed that collagen arranged disorderly and fibroblasts atrophied in the acute closed Achilles tendon rupture group. Immunohistochemical(Sirius staining) results:the proportion of collagenⅠin the acute open Achilles tendon rupture group and the acute closed Achilles tendon rupture group was(91.12±4.34)% and(54.71±17.78)% respectively, and the proportion of collagen Ⅲ was (8.88±4.34)% and (45.29±17.78)% respectively. The content of collagenⅠin the acute closed Achilles tendon rupture group was lower than that in the acute open Achilles tendon rupture group, and the content of collagen Ⅲ in the acute closed Achilles tendon rupture group was higher than that in the acute open Achilles tendon rupture group(P<0.05).@*CONCLUSION@#The morphology, histology and ultrastructure of the acute closed ruptured Achilles tendon are significantly altered compared with the normal Achilles tendon. The original fine and orderly spatial structure cannot be maintained, part of collagen Ⅰ is replaced by collagen Ⅲ, and the toughness and strength of the tendon tissue decreased, which may be the feature of degeneration of the Achilles tendon and an important pathological basis for closed Achilles tendon rupture.
Subject(s)
Adult , Female , Humans , Male , Achilles Tendon/surgery , Retrospective Studies , Rupture/surgery , Suture Techniques , Tendon Injuries/surgery , Treatment OutcomeABSTRACT
OBJECTIVE@#To investigate the clinical effect of scar tissue suture at the broken end of Achilles tendon after gastrocnemius aponeurosis release in the treatment of chronic Achilles tendon rupture.@*METHODS@#The clinical data of 17 patients with old achilles tendon rupture treated from January 2017 to December 2019 were analyzed retrospectively, including 15 males and 2 females, aged 26 to 53 years with an average of (35.2±11.6) years old, and the time from injury to operation was 37 to 92 days with an average of (49.3±13.3) days. Myerson's classification included 6 cases of typeⅡ and 11 cases of typeⅢ. The defect of the broken end of Achilles tendon was 2 to 5 cm with an average of(4.1±1.5) cm after partial scar tissue was removed. All patients were treated with gastrocnemius aponeurosis, appropriate excision of scar tissue at the broken end of Achilles tendon and direct suture. The continuity and healing of Achilles tendon were evaluated by color Doppler ultrasound 3 months after operation. The ankle plantar flexor strength was measured by ankle plantar flexor strength tester before operation and 1 year after operation. American Orthopaedic Foot and Ankle Society ankle hindfoot score (AOFAS) and Achilles tendon rupture score were used before operation and 1 year after operation Achilles tendon total fracture score (ATRS) was used to evaluate the clinical rehabilitation of Achilles tendon rupture.@*RESULTS@#All patients were followed up for 12 to 18 months with an average of(13.6±1.8) months. The surgical incision healed in stageⅠ. Color Doppler ultrasound showed good continuity of Achilles tendon, local Achilles tendon slightly thickened and irregular fiber direction. The ankle plantar flexor force (92.2±3.9) N at 1 year after operation was significantly higher than that before operation (29.5±4.2) N (P<0.05);One year after operation, the AOFAS(91.20±3.30) was significantly higher than that before operation (42.20±4.40)(P<0.05);the ATRS (90.70±3.00) was significantly higher than that before operation(40.00±2.90)(P<0.05).@*CONCLUSION@#The gastrocnemius aponeurosis release combined with scar suture of Achilles tendon end is an effective technique for the treatment of chronic Achilles tendon rupture, avoid injury to hallux flexor longus or flexor digitorum longus, with the plantar flexor muscle strength of the ankle was recovered well, is an effective method to treat chronic Achilles tendon rupture.
Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Achilles Tendon/surgery , Aponeurosis , Cicatrix , Retrospective Studies , Rupture/surgery , Sutures , Treatment OutcomeABSTRACT
Relata-se o caso de uma felina, sem raça definida, de oito meses de idade e 3,6 kg, com queixa de impotência funcional completa do membro pélvico esquerdo após trauma. A paciente apresentava aumento de volume em região do joelho, dor à palpação e instabilidade patelar. O diagnóstico de ruptura do ligamento patelar foi realizado com base nos resultados do exame ortopédico, juntamente com exame radiográfico e ultrassonográfico do joelho. O método utilizado para reparo da lesão foi a sutura em oito com fio de tetrafluorcabono associado à sutura interrompida simples para aproximação das bordas do ligamento. Durante a reavaliação de trinta dias pós-operatório, a paciente já apresentava melhora significativa, com atividade funcional completa do membro e ausência de dor.
We report the case of an eight-month-old, 3.6 kg, crossbred feline, complaining of complete functional impotence of the left pelvic limb after trauma. The patient presented swelling in the knee region, pain on palpation and patellar instability. The diagnosis of patellar ligament rupture was based on the results of the orthopedic examination, together with radiographic and ultrasound examinations of the knee. The method used to repair the lesion was eight-point suture with tetrafluorocabono thread associated with simple interrupted suture for approximation of the ligament edges. During the thirty-day postoperative reassessment, the patient already presented significant improvement, with complete functional activity of the limb. and absence of pain.
Subject(s)
Animals , Cats , Cats/injuries , Patellar Ligament/surgery , Rupture/surgery , Rupture/veterinaryABSTRACT
ABSTRACT Purpose: To describe penile fracture (PF) findings with non-sexual etiology in a referral emergency hospital, with emphasis on demographic data, clinical and intraoperative findings and long-term outcomes. Materials and Methods: Patients with PF of non-sexual cause operated at our institution from January 2014 to January 2019 were submitted to surgical treatment and monitored for at least three months after surgery. Etiology of trauma, epidemiological and clinical presentation data, time to intervention and operative findings were reviewed retrospectively. The evaluation of postoperative erectile function was carried out by filling out the International Index of Erection Function - 5 (IIEF-5). The tool used to assess urinary function was the International Prostate Symptom Score (IPSS) questionnaire. Results: Of a total of 149 patients submitted to surgical treatment for PF, 18 (12%) reported non-sexual etiology. Twelve (66.6%) cases were due to penile manipulation through the act of bending the penis during morning erection, three (16.6%) when rolling over in bed with erect penis, one (5.5%) when embracing the wife during erection, one (5.5%) to laying on the partner with erect penis and the other (5.5%) when sitting on the toilet with an erection. Operative findings were unilateral corpus cavernosum injury in all cases. Only one (5.5%) patient had a partial urethral lesion. Follow-up time varied from 3 to 18 months (mean, 10.1 months). Three (16.6%) patients developed erectile dysfunction six months after surgery. However, all of them responded to treatment with IPDE-5 and reported improvement of erection, with no need for medication, on reevaluation after 18 months. One (5.5%) patient developed penile curvature < 30 degrees. Thirteen (72.2%) patients developed penile nodules. No patient presented voiding complaints during follow-up. Conclusions: PF is a rare urologic emergency, especially with the non-sexual etiology. However, PF should always be considered when the clinical presentation is suggestive, regardless of the etiology. Penile manipulation and roll over in bed were the most common non-sexual causes. These cases are related to low-energy traumas, usually leading to unilateral rupture of corpus cavernosum. Urethral involvement is uncommon but may be present. Early treatment has good long-term clinical outcome, especially when performed in specialized centers with extensive experience in FP.
Subject(s)
Humans , Male , Penile Diseases , Penis/surgery , Referral and Consultation , Rupture/surgery , Penile Erection , Retrospective Studies , Treatment Outcome , HospitalsABSTRACT
OBJECTIVE@#To compare biomechanical characteristic of different high-strength sutures and suture sites for repairing posterior root tear of the medial meniscus with modified Mason-Allen technique.@*METHODS@#Forty-eight specimen of medial meniscus of knee joint from fresh porcine (female, aged from 5 to 9 months with an average of 7 months) were chosen and established experimental model. The samples were divided into red zone fixation group and red-white zone fixation group according to suture sites, 24 in each group; and then were randomly divided into 3 subgroups which 8 in each group, and fixed with Ethibond suture, Ultrabraid suture and FiberWire suture, respectively. Biomechanical tests were performedon universal electromagnetic and mechanical testing machine. Each specimen was underwent 1 000 cyclic tests on the first time, then pull out test until failure. The maximum failure load, yield load, stiffness and displacement were analyzed.@*RESULTS@#All specimen were successfully completed biomechanical tests. The failure mode of Ethibond group was caused by suture fracture; 6 cases of Ultrabraid suture group was caused by suture fracture which belong to red zone fixation group, 10 cases were caused by suture pull out, which 2 cases belong to red zone fixation group, 8 cases belong to red-white zone fixation group;8 cases of FiberWire group was caused by suture pull-out. Biomechanical test showed that:(1)In terms of suture strength, comparison of the maximum failure load, yield load and stiffness showed that Ethibond suture group Subject(s)
Animals
, Female
, Biomechanical Phenomena
, Menisci, Tibial/surgery
, Rupture/surgery
, Suture Techniques
, Sutures
, Swine
ABSTRACT
Resumen: Introducción: En la ruptura del manguito de los rotadores, el tendón del supraespinoso ocupa el primer lugar en frecuencia. La resonancia magnética es el estudio de elección para el diagnóstico y planificación preoperatoria. El objetivo de este estudio fue evaluar la concordancia entre los hallazgos observados con la IRM y los hallazgos transoperatorios en pacientes con ruptura del tendón del supraespinoso. Material y métodos: Se realizó un análisis retrospectivo de Enero de 2014 a Enero de 2020. Se incluyeron pacientes mayores de 18 años, con IRM y reporte de ruptura del tendón del supraespinoso. Se realizó un análisis de χ2 para la sensibilidad, especificidad, valores predictivos y certeza diagnóstica utilizando los hallazgos quirúrgicos como referencia. Se utilizó el índice de Kappa para mostrar la concordancia entre IRM y hallazgos transoperatorios. Resultados: Un total de 79 pacientes se incluyeron en el estudio, 45 masculinos y 34 femeninos. La edad promedio fue de 52.14 años. La IRM diagnosticó correctamente 60.76% de las rupturas del supraespinoso, mostró una sensibilidad de 74% y especificidad de 96% para rupturas completas. Para rupturas parciales mostró una sensibilidad de 96% y una especificidad de 33%. El índice de Kappa mostró una concordancia de 0.90 para rupturas totales y de 0.53 para rupturas parciales. Conclusiones: La resonancia magnética demostró una buena sensibilidad y especificidad para el diagnóstico de rupturas completas, con una buena concordancia con los hallazgos quirúrgicos. La IRM demostró ser un estudio poco específico para la identificación de rupturas parciales, lo cual genera que estas lesiones estén sobrediagnosticadas.
Abstract: Introduction: In rotator cuff rupture, the supraspinatus tendon ranks first in frequency. MRI is the study of choice for preoperative diagnosis and planning. The objective of this study was to assess the concordance between findings observed with MRI and transoperative in patients with supraspinatus tendon rupture. Material and methods: A retrospective analysis was conducted from January 2014 to January 2020. Including patients over the age of 18, with MRI and supraspinatus tendon rupture report. A χ2 analysis was performed for sensitivity, specificity, predictive values and diagnostic certainty using surgical findings as a reference. The kappa index was used to show the concordance between MRI and transoperative findings. Results: A total of 79 patients were included in the study, 45 male and 34 female. The average age was 52.14 years. MRI correctly diagnosed 60.76% of supraspinatus ruptures, showing 74% sensitivity and 96% specificity for complete ruptures. For partial ruptures I show a sensitivity of 96%, a specificity of 33%. The kappa index showed a match of 0.90 for total ruptures and 0.53 for partial. Conclusions: MRI demonstrated good sensitivity and specificity for diagnosing complete ruptures, with good match to surgical findings. MRI proved to be a non-specific study for the identification of partial ruptures, which causes these lesions to be overdiagnosed.